Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹38.8 L+₹6.0 L (18.1%)Rejected-AOC SHOP NO 10 ASHRAM MANDIR NAKATIA P O P A C SHAHJAHANPUR ROAD BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-AOC L2 BIDDER | |
| 3 | L3₹41.3 L+₹8.4 L (25.6%)Rejected-AOC 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | L3 | Rejected-AOC L3 BIDDER |
Tender Value
₹37.6 L
EMD Value
₹75,200
Closing Date
20 Dec 2023, 6:00 pmClosed
GE 871 EWS
GE 871 EWS PIN 913871 C/o 56 APO
PROVISION OF SECURITY LIGHTS AT CERTAIN PLACES AND PROVISION OF RETROFITTING OF EMISSION IN CERTAIN GENERATOR SETS AT JOSHIMATH
2023_MES_628793_1
8772/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Joshimath
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹75,200
Yes
4 Mar 2024
18 Nov 2023
27 Dec 2023
18 Nov 2023
20 Dec 2023
6 Dec 2023
Amount
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable pipe and getting out in soft disintegrated rock and making good the disturbed surface by filling PCC 1:2:4 type B-1 using 20 mm graded stone aggregate to match with existing surfaces all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exc 1.5 m and not exceeding 3.0 mtr in depth for foundation. (Laying of under ground cables) in hard/dense soil and getting out all as directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
M & L Foundation for steel tubular poles of concrete 15 cm Depth in bottom of Pit for bed concrete (1:4:8) Type D-2 using 40 mm graded stone aggregate including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
M & L Foundation for steel tubular poles of PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
M&L PCC (1:2:4) type B-1 using 20 mm graded stone aggregate for coping of poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
Supply, laying, jointing & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 16 sqmm 4 core all as specified & directed. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule).
Supply, laying, jointing & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 10 sqmm 2 core all as specified & directed. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule).
Supply and fix of light grade Galvanised mild steel pipe 40 mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable protection. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule).
Supply and fix, errecting of steel tubular swaged poles with cast iron base plate of size 300 mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & white paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in white paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Supply, fix and commissioning of street light fitting 60 Watt LED, energy saving and environmental friendly long life led street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 including connected wire for street light to pole box complete all as specified. Make :- Bajaj Cat Part No. ZELA P 72L WH PO TG SD or equivalent of Havells /Surya/CG
M & L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge. NOTE :- 1. GI earth wire and protection pipe beyond 7.5 mtr will be measured and paid separately. 2. If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost paid by Dept.
Supply and fix of bracket made out of GI tubing single piece bended type (not welded) at proper angle of size 40 mm dia, light grade 120 cm long including painting with aluminium paint over one coat of red oxide to the bracket ,MS clamps 02 Nos with 04 Nos nuts bolts and washer etc complete. including 4sqmm 2.0 core flexible Copper cable PVC insulation 6.5 mtr long in PVC conduit with clamp U type from junction box to connecter of street light fitting.
Supply and fix of pole box of size 450 x 300 x 200 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 10 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp 02 Nos with nuts, bolts and washers complete all as specified and directed. Make : HPL/ C&S/ Gaurav/ Shalabh india ltd
Supply and fix, “Lithium based Energy Efficient Integrated Solar Street Light of 50Watt” in Single FRP body with duly Polyurethane coating, encases with Monocrystalline Solar PV Panel of 90/95Wp , Lithium Battery 11.1/12.8V, 43.5AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution, CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function (first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 18-20kg including medium grade Galvanised Iron pipe 80 mm bore 7 mtr long swaged type including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30 cm wide circular bands with black & white paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in white paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide with MS base plate of size 30cm x 30cm x 06mm thick fixed to poles, with finial taper plug , suitable adjustable MS clamp , bolts , nuts and washers suitable for pole mounting etc complete as required and all as specified and directed. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and the fitting shall be made in India with CE & ROHS compliant. Make:- Axxon Cart Part No: Axxon (AXN-50W) or equivalent of Bajaj / Philips.
Material and labour for laying DWC (Double wall corrugated ) pipe conforming or IS 16205 (electric cable use) of nominal outer dia 40mm and inner dia 32mm for laying electrical cables under trenches / under road/ wall complete all as specified and directed. Make : Universal /Rax or equivalent
Material and labour for laying DWC (Double wall corrugated ) pipe conforming or IS 16205 (electric cable use) of nominal outer dia 50 mm and inner dia 38mm for laying electrical cables under trenches / under road/ wall complete all as specified and directed. Make : Universal /Rax or equivalent
Supply , fixing and installation of street light automatic timer switch panel digital type timer switch of 3 phase of capacity 65A contactor / 63A TP including all connection to be fixed on LT pole / Wall complete with electrical connection with existing electric supply with suitable size of cable and testing after installation all as specified and directed. Make : Indoasian cat part No TL 065DB0 or equivalent of Havells/ C&S
Supply, installation, testing & commissioning of Retrofit Emission Control Device (RECD) automatic type for reducing DG Emission, Stainless Steel as per latest CPCB guidelines suitable for DG set of capacity 125 KVA with following components:-
(a) DG range - 125 KVA (b) technology - ESP (Electrostatic precipitation) (c) Filter less system (d) No noise level (e) Particulate matter capturing efficiency - Min 70% (f) By product disposal cope - Should in vendor scope (g) Particular size captured - PM 2.5 (h) Actuation Type - Electrostatic (j) Cleaning system - Automatic (k) Material of construction (outer body ) - Powder coated mild steel (l) Material of construction inner cell - SS-304 (m) Insulation on emission device - Glass wool (n) Back pressure on engine - No back pressure ( Should be less than 10 Kpa ) and static pressure less than 1 Kpa (o) Testing requirements post installation at site (p) There should not be any Bypass arrangement in RECD to let the pollutants bypass the RECD on any account (q ) AMC for one year after installation
Note : (a) Retrofit Emission Control Device (RECD) shall be any of the make:- M/s P I Green Innovations Pvt Ltd, M/s Platino Automative Pvt Ltd, M/s Chakr Innovation Pvt Ltd (b) All the aux materials required for installation at site including field piping fabrication & erection , civil foundation design & execution (if required),painting etc shall be provided by the contractor and included in quoted rate. (c) the device must be tested by one of the five currently CPCB recognized / Approved laboratories:- (i) Automatic research association of India , Pune ( Maharashtra ) (ii) International centre for automotive technology , Manser (Haryana) (iii) Indian Oil corporation , Research and development centre Faridabad (Haryana) (iv) Indian institute of Petroleum , Dehradun (Uttrakhand) (v) Vehicle Research Development Establishment , Amednagar (Maharashtra )
Supply, installation, testing & commissioning of Retrofit Emission Control Device (RECD) automatic type for reducing DG Emission, Stainless Steel as per latest CPCB guidelines suitable for DG set of capacity 200 KVA with following components:-
(a) DG range - 200 KVA (b) technology - ESP (Electrostatic precipitation) © Filter less system (d) Noise level - No noise (e) Particulate matter capturing efficiency - Min 70% (f) By product disposal cope - Should in vendor scope (g) Particular size captured - PM 2.5 (h) Actuation Type - Electrostatic (j) Cleaning system - Automatic (k) Material of construction (outer body ) - Powder coated mild steel (l) Material of construction inner cell - SS-304 (m) Insulation on emission device - Glass wool (n) Back pressure on engine - No back pressure ( Should be less than 100mm of Hg (o) Testing requirements post installation at site (p) There should not be any Bypass arrangement in RECD to let the pollutants bypass the RECD on any account (q) AMC for one year after installation
Note : (a) Retrofit Emission Control Device (RECD) shall be any of the make:- M/s P I Green Innovations Pvt Ltd, M/s Platino Automative Pvt Ltd, M/s Chakr Innovation Pvt Ltd. (b) All the aux materials required for installation at site including field piping fabrication & erection , civil foundation design & execution (if required),painting etc shall be provided by the contractor and included in quoted rate. (c) the device must be tested by one of the five currently CPCB recognized / Approved laboratories:- (i) Automatic research association of India , Pune ( Maharashtra ) (ii) International centre for automotive technology , Manser (Haryana) (iii) Indian Oil corporation , Research and development centre Faridabad (Haryana) (iv) Indian institute of Petroleum , Dehradun (Uttrakhand) (v) Vehicle Research Development Establishment , Amednagar (Maharashtra )
NOORI ELECTRIC ENGINEERING WORKS
Alpha Engineers and Builders
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .