Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹16.4 LAccepted-AOC | L-1 | Accepted-AOC Lowest | |
| 2 | L-2₹17.6 L+₹92,904 (5.57%)Rejected-AOC | L-2 | Rejected-AOC Other than Lowest | |
| 3 | L-3₹17.9 L+₹1.2 L (7.01%)Rejected-AOC R O ABI GUZAR THE BUND SRINAGAR 190001 J K | SRINAGAR | JAMMU AND KASHMIR | 190001 | L-3 | Rejected-AOC Other than Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
24 Sept 2022, 6:00 pmClosed
GE 969 EWS
GE 969 EWS C/O 56 APO
SPL REPAIR TO INTERNAL WIRING WITH FITTINGS AND FIXTURES IN BLDG NO T-36A (HI CH/DH) T-38A (STUDENT NCOs CH/DH) P-73 (DEMO COY 80 OR OTM ACCN) PROVN OF TRAILER MOUNTED STANDBY DG SET OF CAPACITY OF 62.5 KVA AT HAWS GULMARG UNDER GE 969 EWS
2022_MES_548430_1
CANO 969/WS- /2022-23
Open Tender
Civil Works
Item Rate
180 days
GULMARG
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE 969 EWS
₹40,000
Yes
17 Oct 2022
29 Aug 2022
27 Sept 2022
29 Aug 2022
24 Sept 2022
12 Sept 2022
Amount
Taking down carefully any type point wiring (light, fan, socket or power) complete including conduits/casing- capping with fittings such as light fittings, sockets, switches ceiling roses, board outlets etc and removing the materials/ debris and making good the disturbed surfaces of walls, floor etc to match with the existing surface.
M&L Point wiring complete with FRLS 1100 Volts grade, 1.5 Sqmm PVC insulated and unsheathed copper conductor single core cable drawn through and including 25 mm medium grade ISI marked PVC casing caping with all accessonies such as bends, elbow, reducers . junction boxes /MS boxes duly painted /PVC box factory made ractangular in shape as required with top cover 3 mm thick plastic laminated sheets of required size, fixed with screws. for housing switches, sockets, regulators etc, including 1.5 sqmm PVC insulated and unsheathed copper conductor cable as earth continuity wire connected to common earth dolly all as Specified and as directed, for the following :-
(a) One light point/fan point/exhaust fan point controlled by one 5 Amps switch one way
(b) One 3 pin 5 Amp switch socket outlet on independent board
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor.
S&F switch piano Flush type. single pole, one way 6 amp 240 volts, complete all as specified and as directed.
Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and as directed.
S&F Socket outlet 2 in 1. 3 pin, 5 Amps, flush type complete all as specified and as directed.
Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed.
Supply and fix ceiling rose 3 terminal /PVC/ Polycarbonate, isolated body.
S&F Distribution Board SPN 12 Way. Single door Complete all as specified and as directed.
S&F Distribution Board SPN 4 Way. Single door complete all as specified and as directed.
S&F Distribution Board SPN 8 Way. Single door complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.SPN 32 Amp.
Supply and fixing amp rating 240V, 10KA C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. SPN 40 to 63 Amp.
Supply and fixing 240v, 10 KA 'B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED Lamp 15W Complete all as specified and as directed.
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed.
S&F LED ight fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.Complete all as specified and as directed.
S &F in repair Sub main wiring using two runs of single core PVC insulated cable with multistranded 1100 volts copper conductor of sizes 6.0 Sqmm through existing/ new non metalic PVC casing capping including Copper earth wire in green colour of size 6.0 Sqmm connection to DB with thimbling complete as specified and directed. (Note Two runs of sub main wire including earth wire and rigid non metalic PVC casing capping shall be measured as one unit per RM make of cable.
S& F Exhaust fan made steel body complete with louvers shutter, voltage 230V, 50 Hz RPM 1200, Copper winding of sweep 450 mm complete all as specified and as directed.
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.5 of SSR 2020 part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 6 mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia Gl pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note: The rate is ilnclusive of necessary earth work, RFR and removal etc
S&F of accessories in Panel (a) MCCB Incoming 63A 4 pole 415V 25KA (1 No) (b) MCCB Outgoing 32A 3 pole 415V 16KA (1 No) (c) MCCB Outgoing 32A 3 pole 415V 16KA (1 No) (d) MCCB Outgoing 32A 3 pole 415V 16KA (1 No)
Supply,Installation Testing & Commisioning of ECO friendly Diesel Engine driven generating set of 62.5 KVA CPCB-II nearest higher side 400/440 Volts,AC 3 phase 50HZ 4 wire,0.8 PF directly coupled alternator and engine watercold with AMF pannel common steel base fixed on cement concrete in foundation filling and mass concrete Type C2 1:3:6(40mm graded aggregate for DG Set of 62.5 KVA platform with floor mounted AMF pannel as directed by manufacture and other accessories comprising of following: a) Engine ECO friendly for emmision and noise (PCB Norm Compliance) 4 Stroke diesel Engine confirming to BS std developing 100 HP@1500 RPM turbocharged aircooled/water cold complete with a provision for 10% overload for one hour on 62.5 KVA.
TECHNICAL SPECIFICATION: i) Dry type Air filter ii) Lub oil Cooler assembly with accesories. iv)Exhaust Air Manifold v) Exhaust Silencer vi) Expansion Bellow vii) Exhaust gas turbocharger vii) Fuel Filter (pree micro) ix) Lubrication oil filter x) 12V electric system with starting motor & battery charging alternator with self starter and other auto electric accessories as recommended by manufacturer xi) Centrifugal by pass filter xi) in line Monoblock fuel pump with mechanical governer and fuel pump xii) Front & Rear engine mounting supports xiv) Engine Control Panel consisting of OFF/ON/Start keys lub oil pressure gauge Ammeter,electronic Hour meter,Speedometer. xv) Safety against low lub oil pressure xvi) Engine operation/Maintenance, Spare parts Manual. xvii) Engine test Certificate xviii) Cold starting kit.
Powder coated control panel manufactured with CRCA sheet provides. Controller which displays voltage current, KW,PF,Frequency KWh, Indicating lamps for "Load ON" and "set running", Current Transformers of suitable Rating. Silent Features: Approved by ARAI, the nodal agency of CPCB,Compact, Modular construction and sleek design with low noise level 75 dBA,at a distance of 1 Mtr from canopy in free field conditions, Soundproof,Weather-Proof and environment friendly silent Set.,Ready to use Silent DG set,Which eliminates need of foundation or grouting, Single bearing generator with Anti vibration mounting ensures minimal Vibration Residential type exhaust silencer is mounted on the enclosure, illumination arrangement inside the canopy.
Designing, fabricating, supplying including all fabrication material for complete trolley suitable for 62.5 KVA DG Set made of rolled mild steel sections. Trolley size not less than 10 feet (length) x 7 feet (width ) x 7 feet (height) (excluding roof height) and interconnected by 'C channels of appropriate sizes 6"x3", 4'"x2"3x1.5" respectively. Square pipe of size not less than 2.5"x2.5" for side wall for support, side wall of MS sheet of thickness not less than 2.5mm (openable with hinges arrangement and welded with side wall),floor sheet of MS chequred plate not less than 5mm thickness mounted on four wheel drum including tyre of size 8.25x16 make of tyre CEAT/MRF complete with inner tube including towing arrangements. Provision of left and right movements of all wheels, provision of covered roof with prelaminated sheets, roof angle not less than 80 degree. provision of tool box and other related minor works as required complete all as specifed and directed by Engr-in-charge. It is also includes the following accessories:
(a) Wheel Axle suitable to accommodate load of trolley and 62.5 KVA DG Set (b) Leaf spring of suitable size - 4 sets (c) Wheel rotation arrangement (d) Mud Guard on all four wheels with reflectors (e) Four Nos 2 ton (each) capacity vertical jacks fixed on trolley of suitable trawer to hove 80mm clearance for tyres from ground level for idle period for lifting. (f) Earth lead 35 Sqmm copper cable fixed with copper thimble 30 RM Each - 04 Nos Note:- (i) The sizes of MS sections are indicative only all other MS sections required for the fabrication of trolley are deemed to be included in rate quoted. (ii) Weight of Raw material should not be less than 1500 Kg
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3.5 core complete all as specified and as directed.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps (with Standby changeover) complete all as specified and as directed.
Note:- Schedule of credit Rs. 23,969.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
M/S KULWANT SINGH RAINA AND CO
M/S GASSI CONSTRUCTION AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .