Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC C 488 SC PLOT NO 10 EKTA NAGAR NEAR ANANT LEWIS PUBLIC SCHOOL BANAR ROAD NANDRI PO SARAN NAGAR JODHPUR 342015 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹39.4 L+₹2.5 L (6.75%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹44.4 L+₹7.4 L (20.1%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹91,000
Closing Date
26 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
CONSTRUCTION OF STORE ROOM FOR HQ JODHPUR SUB AREA AND OTHER SANCTIONED WORK IN THE AREA OF AGE B/R-II UNDER GE (A) NO. 1 JODHPUR.
2024_MES_675112_1
GE/JODH (A) NO 1- OF 2024-25 (9258/E8)
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE ARMY NO. 1
₹91,000
Yes
7 Dec 2024
18 Sept 2024
2 Nov 2024
18 Sept 2024
26 Oct 2024
3 Oct 2024
Amount
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in any type of soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all type of soil, complete all as specified and directed.
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed.
M&L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
M & L for Cement concrete in foundations, filling and mass concrete 1:4:8 D2 (40mm graded aggregate) foundation, wall, complete all as specified and directed.
M&L for ATT treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and directed.
M&L for ATT treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface, complete all as specified and directed.
M&L for ATT treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall, complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter of flate and fair finish surface, complete all as specified and directed.
M & L for RCC M-25 design mix in Foundations, including rafts, footings, foundation, plinth beams; bases for columns, etc. complete all as specified and as directed by Emgr-in-charge.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions of rectangular fair finish surface complete all as specified and as directed by Engr-in-charge.
M &L for RCC M-25 design mix in Columns, pillars, piers, posts and struts complete all as specified and as directed by Emgr-in-charge.
Formwork to sides and soffits of floor or roof beams, beam haunch?ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed by Emgr-in-charge.
M&L for M-25 design mix of Beams, cantilevers, bressummers, lintels over 1.5m spain complete all as specified and as directed by Engr-in-charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed by Emgr-in-charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail?ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon?tal or sloping and similar work exc 10cm but n exc 20cm wid (120mm thick of roof slab) complete all as specified and as directed by Engr-in-charge.
M&L for M -25 design mix for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like (120mm thick roof slabe thick) complete all as specified and as directed.
M&L for neat cement slurry @ 3.00 kg/Sqm and screeding / bedding layer of 10 mm thick in CM 1:3 mixed with water proofing compound as per manufacturer instructions over the RCC roof slab for laying of water proofing treatment including providing the following as roof treatment complete all as specified and as directed : - (a) FIRST COURSE: Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces. (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 100mm micron HMHDPE, outer film 20 micron each, thickness 3.00mm having weight not less than 3.00 Kg/Sqm using torch application method with minimum 10cm side lap and 15cm end lap complete . (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen conforming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. (e) FIFTH COURSE : 40 mm thick plain cement concrete 1:2:4 (using 20 mm stone crushed aggregate) as in roof padding, including WPC as per manufacturer instruction. NOTE :- 1. A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause, in plaster engraving in and painted as directed by GE 2.WPC shall be measured and paid separately under respective item.
M & L for HYSD TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips for column,beams, Roof, complete all as specified and directed.
M & L for HYSD TMT bars 5mm dia and over upto andincluding 10mm dia in stirrups, spacers and binders to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Supply and fabrication of Mild steel soft drawn binding or tying wire 1 mm dia, annealed, complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks type of 1:2:4 C1 (20mm graded aggregate), exc. 10 cm in width and setting in mortar, completeset in CM 1:4, complete all as specified and directed.
M&L for squarred rubble walling Jodhpur type regular coursed well bonded, bedded and solidly hearted built in cement mortar 1:6, complete all as specified and directed.
Extra over squared rubble stone walling Jodhpur type regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing, complete all as specified and directed.
M&L for Rendering 15 mm thick on other then fair faces of stone masonary or solid PCC block surface or concrete surfaces of CM 1:6 be finished even and smooth (without using cement) complete all as specidied and directed.
M&L for Rendering 10 mm thick on other then fair faces of solid PCC block surface or concrete surfaces of CM 1:4 be finished even and smooth mixed with WPC (without using cement) complete all as specidied and directed.
M&L for Rendering 5mm thick on fair faces of cilling of CM 1:4 to be finished even and smooth (without using extra lime or cement, complete all as specified and directed.
M&L for Earth filling under floor, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering 100mm thick, complete all as specified and directed.
M & L for Hardcore of gauge n exc. 63 mm, broken stone and boulders to deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L for Cement concrete type B-1,1:2:4 (20mm graded stone aggregate) as sub base of flooring of 100 mm thick, complete all as specified and directed.
M&L of 18-20mm thick machine cut kota stone slab as in floor (size not less than 580mm x 580mm) , treads, steps etc(Single piece for steps), machine cut, laid over cement and jointed with grey cement slurry with pigment to match the shade of the slab, incl rubbing and Mirror polishing all as specified as in floors over and including 15mm thick in screed bed in CM (1:6), complete all as specified and directed.
M&L of 18-20mm thick machine cut kota stone slab riser of step , skirting, dado etc(Single piece for steps), machine cut, laid over cement and jointed with grey cement slurry with pigment to match the shade of the slab, incl rubbing and Mirror polishing all as specified including backing coat of 10mm thick in CM (1:4), complete all as specified and directed.
M&L for applying single coat chalk whiting on wall surfaces including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper paint on wall surfaces as per manufacturer’s instruction, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. ii)- Paint shall be in one or more colours/ shades all as approved by GE.
M&L for three coats of white wash including preparation of new surfaces as on ceilings all as specified and as directed.
M&L for preparation of new plastered or un-plastered surfaces of walls and applying two coats of cement base paint over & including M&L one coat of alkali resitant primer, complete all as specified and as directed.
M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
S&F factory made box type windows (steel) (BWM) with side hung shutter as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete with glazing bars, dovetailed or welded. Note.:Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same.
M & L for pressed steel door frames (105X60 mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates, PCC etc, complete all as specified and directed
M&L for Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded, complete all as specified and direceted.
Supply and fabrication of Mild steel guard bars, grills, grating, and similar work and welded to window frames, door frames (made up of angle), balcony railing confirming to FE 290, gde E-165 etc, complete all as specified and direceted.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18 mm, complete all as specified and direceted.
S&F 3mm thick sheet glass Pin headed and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed
Surface of any description, over 10 cm in width or girth, not otherwise described of two coats of synthetic enamel paint and a coat of red oxide, zinc chrome and new or previously untreated steel surfaces, complete all as specified and direceted.
M&L of 20-25mm thick machine cut KOTA stone slab as in shelves (Single piece) fixed in walls, self, selves, partation, slab etc. machine cut, laid over cement and jointed with grey cement slurry with pigment to match the shade of the slab, incl rubbing and Mirror polishing, complete all as specified and direceted.
M&L for PCC 1:3:6 type C-I using 20mm graded crushed stone aggregate as in plinth protection 75mm thick/flooring laid in alternate pannels finished even and smooth without using extra cement, complete all as specified and direceted.
S&F 100mm long butt hinges, extruded alluminium alloy with galvanized mild steel hinge pin, anodized and fixed, type B-21 complete all as specified and directed.
S&F 200mm long aluminium anodized barrel tower bolt of extruded section and fixed complete all as specified and directed.
S&F 150mm long alluminium handles, cast type, anodized and fixed complete all as specified and directed.
S&F of aluminium alloy anodised sliding door bolt woth hasp and stalpe (bolt type and fixings clips of sheet cast or extruded sections and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 300mm long, complete all as specified and directed.
Supply only integral water proofing compound complete all as specified.
S&F decorative type curtain rod stainless steel finish of pipe 22 to 25 mm dia with best quality knob metal with double fitting type including stainless steel brackets fixed to walls complete with two nos decorative stainless steel knobs at each end (As approved by Engr -in-charge).
S & F Iron plates, any size, of galvanised iron sheet 1mm thick, fixed with galvanised screws in iron gate, complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D2 (using graded stone aggregate) as in sub base,complete all as specified and directed.
M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
M&L for two coat of synthetic enamel paint on new concrete surface including preparation of surface, complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete etc., complete all as specified and directed.
Demolition of stone / boulder masonry walling, built in cement mortar including all quoins, arches, pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and directed.
M&L for keyed pointing in CM 1:3 to Squared rubble regular coursed Jodhpur type masonry, complete all as specified and directed.
M&L for 20 to 22 mm thick (telephone black shade) granite stone, as in WHB counter top, machine cut, (table rubbed and polished) best quality as per sample, over & including 20 mm thick screeding in CM1:3 including rounding & double mouldlng with jointless finish of the edges, including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed
M&L for dark shade/double charged vitrified ceramic tiles, 10 mm thick (square/ rectagular) polished, area of each tiles exceeding 0.18 sqm exceeding 0.36 sqm, (size & shape, shade and pattern as approved by GE), as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles, over & including M&L 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
M&L for joint free glazed colour ceramic tiles (premium quality) of size area of each tile exc. 0.11 Sqm but not exc 0.18 Sqm, 6-7 mm thick, as in vertical surface such as i.e. dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over & including M&L 10mm thick backing coat in CM (1:3) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete
S&F rotational moulded polythene water storage tanks of 1000 ltrs capacity, white three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I with PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms, complete all as specified and directed.
Supplying and laying of CPVC pipes 20 mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings in wall/floor etc complete all as specified and directed.
Supplying and laying of CPVC pipes 25 mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings in wall/floor etc complete all as specified and directed.
Demoltion of cement concrete padding of water proofing treatment from roof pading taking down bituminous polythene sheets plaster etc overall thickness n.exc 200mm , cleaning of concete surfaces by wire brushres scrubbing down water and removing the dust debris etc. to a distance 50 mtre but n.exc 250 mtr from the site,complete all as directed.
M&L for Plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as over roof for making good depression/ undulation to make the existing as filling in depression of roof slab,complete all as specified and as directed.
M&L for Preparation of new/old plastered surfaces & applying two coat of wall care putty to remove all depressions etc incl sandpapering the surfaces & obtain a smooth surfaces and applying two coat of plastic emulsion paint complete all as specified & directed.
M&L for Preparation of new/old surfces of plastered /pointed & applying two coats of exterior weather coat paint over a coat of suitable primer,complete all as specified and as directed.
M&L for 4-5 cm thick machine cut sand stone slab in sun shades, chajjas, shelves, cills, landings, cover stones, templates, etc., n. exc. 2 m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4, complete and all as specified and directed.
Taking down carefully cement conc /spalled out concrete from RCC roof projections, cilinigs ,sunsheds, beams, etc upto cover depth by chipping out lightly including necessary scafolding etc ,complete all as specified and as directed.
M&L for 10-15 mm thick rendering in CM 1:3 over the bond coat applied surfaces with cement mixed with SIKA PLASTOCRETE SUPER admixture @ 100 gm /50kg of cement & finishing the surface even & smooth complete all as directed at site
M&L for 15mm bore CP brass angular stop cock screwed for iron pipe or ferrule and fixed complete all as specified and directed
M&L for Fabrication of powder coated aluminium frame work as in frames for aluminium windows with or without rebate or for sliding windows(two track/three track ) , ventilators etc with louvers having suitable mechanism for tilting , U shaped fillets for securing Jallies etc & the likes complete all as per sample kept in GE Office & fixed in position complete all as specified and directed Note : Glass panes in louvers & stainless steel wire cloth shall be measured & paid for seperately,
M&L for Pre powder coated aluminium decogrill all as per sample fixed to aluminium framework of windows & ventilators, complete all as specified and directed
M&L for Pre powder coated aluminium window shutters prepared for sliding or hanging etc including handles, tower bolt and hinges complete using section weighing 0.55 kg/RM including necessary joinng cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as directed & specified
M&L for Pre powder coated aluminium door shutters using section weighing 0.55 kg/RM including necessary joinng cleats, glazing clips, rubber packing, handle 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc complete all as directed & specified
M&L for 4.80 mm thick plain Sheet glass/ tinted or coloured film as required, ordinary quality and glazing withsecured in wooden beads or snap fit glazinng clips square exc 0.5 sq. m in each pane, complete all as specified and directed
M&L for Stainless steel wire cloth 0.36 mm nominal dia of wire & avg width of appertuer 1.40 mm fixed to Anodised aliminium framework of windows / vents & door shutters etc., complete all as specified and directed
S&F 12 mm thick toughened glass as in door/window or partition complete including design etching work /sun control film as directed and all necessary stainless steel fittings arrangement like hinges, clips, handle etc., complete all as specified and directed
S& F stainless steel body bottom floor spring machine screwed suitable for glass door complete all as specified and as directed
S&F 18 mm thick solid PVC sheet of two different colours( with wood grain printed pattern /ivory clour finish) as in kitchen cabinet shutters ,all round body of cabinets , shelves ,drawers etc cut to required size jointed with solvent cement & steel screws etc complete all as specified & directed .
M&L for 0 degree clip type self closing hinges for cabinets fized with cadimum coated screws all as per sample.
M&L for 100mm size bright finished cromium plated steel handle of approved shape & design fixed with cadmium coated screws on the kitchen cabint shutters
M&L for stainless steel tray as per trade pattern of various sizes for drawer to keep the kitchen utensil incl Drawer runners folding type with guide channels & sliding channel with approipiate ball bearing/ rollers etc complete to obtain smooth movement of the drawers.as directed by Engineer-in-charge
S&F machine made precast cement concrete blocks (interlocking paves) Rubberised finish coloured (lacquer Coated) of 60mm thick with 6mm top layers of anti abrasive material , M-35 Grade all as as per sample approved laid over 25 mm thick sand filling layer & spreading fine sand over the tiles to fill in the joints & cleaning the same after filling of joints all as directed at site (Shape and size shall be approved by Engr-in-Charge) .
M&L for preparation of new/old surfces of existing paver tile and applying two coats of exterior paver tile paint complete all as directed
M&L for Stainless steel sink with draining board,made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm complete all as directed incl taking out & removal of old sink arrangement, complete all as specified and directed.
M&L for 15 mm bore CP cast copper alloy body mixer sink cock with hot & cold mixing valves & casted central spout all as per sample, complete all as specified and directed.
M & L for providing 40-50 mm thick pre-cast cement concrete 1:3:6 type C-0 using 12.5 mm graded stone aggregate as in louvers & jallies (measured solid) including all mouldings and including pre-cast frames set in cement mortar 1:6 complete all as specified and as directed.
M & L for providing precast concrete Posts 100x100mm size & 75-100 cm height 1:3:6 type C0 using 12.50 mm graded stone aggregate as in RCC jali post setting in mortar 1:6 complete all as specified and as directed.
M&L for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches/floors/walls complete all as specified and as directed.
M&L for 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
M&L for 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches/floors/walls as directed
M&L for 75 mm bore PVC (SWR) bends any radius all as directed
M&L for PVC (SWR) floor trap, plain with CP grating with/without hole as directed including jointing with solvent cement for 75 mm bore pipes, complete all as specified and as directed.
M&L for Excavating in post holes (of similar holes) each n. Exc. 0.50 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering and removing surplus soil to a distance n. Exc. 50m and making good surface complete all as specified and directed.
M&L for Angle iron section with swain neck as in fencing posts struts including notching drilling holes for wire mesh etc and flat iron fillets for securing wire mesh etc including all necessary drilling, bolting or riveting and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for Framed work as in door or gates of angle ,MS hollow pipes, solid SQ sections Flat iron etc or other section with gusset plates, rails, braces etc complete with steel sheetingas required to br prepared for hanging or sliding with and including MS Channel as posts & hold fasts & suitable arrangements for locking etc complete all as specified & directed conforming to Fe 290.Gde E165.
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and scrfewed the other, each screwed end to be fitted with washeres and one haxagonal or square nut not exceeding 5cm long with daia of neck 5 to 11 mm complete all as specified and directed.
Supply only chain link MS galvanised fencing of any description, complete all as specified and directed. Note : Weight of chain link fencing will be ascertained BOO.
Fixing only mild steel galvanised chain link fencing including line wires, any mesh size and type to any type of standards, rails, straining bolts etc including provn of binding wire if reqd complete all as specified.
M&L for Mild steel round bars 10mm dia cut to length bent to shape required including cranking bending and binding etc of Gde Fe 410W (Gde E-250) quality A or Fe 290 (Gde E-165) complete all as specified and directed.
M&L for Two coats of synthetic enamel paint on new steel surfaces including preparation over a coat of red oxide Zinc chrome primer ,complete all as specied and as directed.
M&L Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
S&F Prepainted coloured Galvalume aluminium zinc coating GI based corrugated steel Sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
M & L chequered cement concrete tiles(lacquer coated) 30cm x 30cm x 25 mm thick, anti abarasive material with grey cement and pigments, set, jointed and pointed in neat cement slurry as in floors/ path etc over and including screed bed or bedding layer of 15mm thick in CM 1:4 complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4) on stone masonary surfaces , finished even and smooth without using extra cement complete all as specified.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in copings, bed plates, plinth courses, parapets and the like including weathering, slightly rounded or chamfered angles and throating including use and waste of necessary form work etc complete all as specified
S&F in repairs 25-30 mm thick precast cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in Kangaoros width 30 cm with intricate design on one side all as per sample, incl applying 2 coats of cement base paint on exposed surfaces, complete all as specified & directed.
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
Taking down carefully UNSV submain wiring of any size and all as directed.
M&L for modular point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, fan regulators, suitable for One light point controlled by one, one way switch complete all as specified and directed.
All as per srl item no. 115.00 here-in-before but One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch, complete all as specified and directed.
All as per srl item no. 115.00 here-in-before but One socket outlet 3 pin 5 amps on the ind board controlled by one no 5 Amp switch, complete all as specified and directed.
All as per srl item no.115.00 here-in-before but with 2.5 sq mm FRLSH copper wire with 2.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point, complete all as specified and directed.
All as per srl item no. 115.00 here-in-before but with 4 sq mm FRLS copper wire with 4 Sqmm FRLS copper earth wire for indpendent 15 Amp point, complete all as specified and directed.
S&F Modular switch flush type single pole one way 6 Amp ISI Marked, complete all as specified and directed.
S&F Modular switch flush type single pole one way 16 Amp ISI Marked, complete all as specified and directed.
S&F Modular socket outlet 2 in 1, 5 pin, 6 Amp, 230 Volts flush type, complete all as specified and directed.
S&F Modular socket outlet 2 in 1, 6 pin, 5 and 16 amp flush type, 230 Volts ISI Marked, complete all as specified and directed.
S&F Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Cool White LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including AC decorative box type with driver, holder including,copper conductor cable of suitable size from ceiling rose complete complete, 4 ft long, complete all as specified and directed.
Supply and install fixing of Exhaust Hood with Filtres, Lights & Fresh Air Vent for Chapati Range (size 42x48x21 inch), complete all as specified and directed.
Supply and fixing LED Cool White light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete and directed
Supply and fixing LED Warm White light fitting Aesthetically designed, decorative recess mounted 5 W LED (Round) spot light for low ceiling height applications including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
S&F MCB, B Curve type, 10 kA, TPN/FP 40 to 100 AMP, TPN with over load and short circuit protection, complete all as directed and directed
S&F MCB, B Curve type, 10 kA, 40 Amp to 63 Amp, SPN with over load and short circuit protection, complete all as directed and directed.
S&F MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as specif and directed
Supply and fixing as MCB DB TPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed
Supply and fixing as MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed
Supply & Install Storage Type Geyser 25 Ltr Capacity with Copper inner tank including all fitting accessories, Hot water connection pipe, etc required complete all as specified and as directed
M&L for sub main wiring with 2 runs of 4 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 15 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note:- Two runs of 4 Sq.mm. and one run of 4 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
M&L for sub main wiring with 2 runs of 10 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 10 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 25 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note:- Two runs of 10 Sq.mm. and one run of 10 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
M&L for in repairs earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply, laying testing in trenches LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 35 sqmm 3.5 core all as diredted Note : Earth work and brick work measured and paid separately
Supply and laying Un reinforced Precast concrete cable cover, flat size 300 mm x 180 mm x 40mm all as and all as specified and direceted by Engr-in-Charge. .
Supply and lay sand for sand cushioning for cable protection in trenches all as directed and specified in SSR Part - 1. Note:. for the purpose of payment punned thickness will be measured and all as specified and direceted by Engr-in-Charge. .
Supply and fix GI tubing medium grade of 40 mm dia for cable protection.
M&L for Point wiring complete with 1.5 sqmm, single core, multi stranded, copper conductor, PVC (FRLSH), insulated, unsheathed cable, confirming to IS-694, 1100 volts grade, ISI marked (class V conductor), in and including PVC concealed conduit (MMS), ISI marked not less than 20mm, with accessories fixed on surface of wall/roof/ceiling etc and including sunken pressed steel terminal boxes in wall but including 3mm thick plastic laminated sheet top cover (ISI marked hylem sheet and 1.50 sqmm PVC insulated unsheathed stranded copper conductor for common earth and connecting to earth dolly material and labour for :- (a) One light point controlled by one, one way switch
All as per item No. 143.00 here-in-above, but One socket outlet 5 pin 6 Amps on same board
All as per item No. 143.00 here-in-above, but One socket outlet 5 pin 6 Amp on independent board
All as per item No. 143.00 here-in-above, but with 2.5 Sq mm single core multistanded copper conductor cable for 3 pin 16 Amp socket outlet on independent board .
S&F switch flush type single pole one way 6 Amp, 230 Volts, ISI Marked.
S&F switch flush type single pole one way 16 Amp 230 Volts ,ISI Marked.
S&F socket out let , 5 pin , 6 Amp 230 Volts ISI Marked.
S&F socket out let , 5/6 pin ,16 Amp Flush type 230 V, ISI Marked
S&F connecting, and commissioning of street light fitting 25/35 watt LED , IP-65 protection, single peice pressure dia cast aluminium alloy housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and contror gear compartment with high voltage surge protection device upto 4.5 KV, Prewired including 1.60 mtr long 40mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts , nuts & washers and conductor to fitting with 3 core 1.5 sqmm pvc insulated cable complete all as specified
Supply, laying testing in trenches LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 16 sqmm 2 core all as diredted by Engr - in - charge. Note : Earth work and brick work measured and paid separately
M&L for Two coats of synthetic enamel paint on new steel surfaces including preparation over a coat of red oxide Zinc chrome primer ,complete all as specied and as directed.
NOTE:- (i)- Quantities are clubbed in BOQ for different Jobs. For which ref. Annexure-I on Sl. page. No. 48 to 50 of tender document. (ii)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
M/S KAUTILYA GARG (BID ID -3150975)
Nikhat nirman (BID ID -3145283)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .