Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC 45 38 15 JAGANNADHAPURAM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹20.7 L+₹31,607.02 (1.55%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹22.8 L+₹2.4 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹23.5 L+₹3.1 L (15.2%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹23.9 L+₹3.5 L (17.0%)Rejected-Finance D NO 71 31 252 DURGANAGAR MALKAPURAM VISAKHAPATNAM 530011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹24.2 L
EMD Value
₹48,400
Closing Date
11 Mar 2023, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
SPECIAL REPAIRS TO NAI (BPM) ADMIN CUM TECHNICAL BLDG. (P-90) UNDER SPECIAL REPAIRS B/R AT NAVAL STATION BHEEMUNIPATNAM UNDER GE (P) NAVY KALINGA VISAKHAPATNAM
2023_MES_579687_1
GE (P)/N/K/8980 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class E, Category a(i)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹48,400
Yes
1 Apr 2023
8 Feb 2023
13 Mar 2023
8 Feb 2023
11 Mar 2023
25 Feb 2023
Amount
Dismantling floor hearth wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles portions ordered to be dismantled complete all as specified and as directed by the Engineer-in-Charge.
M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built modular sized brick in cement mortar 1:6 complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 complete
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 in two layers of 10 mm and 5 mm thick and finished fair and even without using extra cement and including using the water proofing compound for second layer of external plastering complete all as specified and as directed. Note: WPC will be measured and paid separately under relevant item as supply only
Supply only Integral Water Proofing Compound (ISI marked) of approved make.
M&L for rendering 5 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:3 and finished fair and even without using extra cement.
M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection , pavement surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over Screed bed or bedding layer of mortar 15mm of thick CM 1:4 for laying floor finishes
M & L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surface(skirting)/dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing of 10 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces complete.
M & L for 20 mm thick Granite (of any type) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of granite over a screed bed of 20 mm thick in cement mortar (1:6) incl rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified.
M & L for 20mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over a backing coat of 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4
S&F non skid ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over and incl 15mm thick screed bed of CM 1:6 complete of item all as directed.
M & L for glazed ceramic coloured tiles 300 x 450 of 6-7 mm thick (Ist quality) as in vertical surface such as skirting/dado set in neat cement slurry and pointed in coloured cement to match the surface, including 10mm thick rendering to receive tiles in CM (1:3) finished even and rough complete all as specified and as directed.
M&L for post construction ant termite treatment at points of contact of wood work by chemical emulsion(water based solution)@ 0.5 Ltr/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same with Chlorpyrifos or Lindane Emulsifiable Concentrate conforming to IS 8944 or IS 632 respectively
M&L for Treatment of soil under existing floor using emulsion @ 1 ltr per hole 300mm centre to centre including drilling and plugging 12mm dia holes with CM 1:2 to match existing floor.
M & L for Post construction Anti Termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed.
S & F Anodised aluminium snap grid frame work for false ceiling of size 605 x 605mm all as specified
M&L 4mm thick non-asbestos fibre cement plain building boards fixed to timber/GI/aluminium framework with screws in false ceiling complete all as specified and directed by the Engineer-in-Charge.
S & F for hangers 6 mm dia G.I Upto (1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of G.I Flat 40 x 3 mm size 600 mm long and expansion hold fasteners 12.5 mm dia . 40mm long complete all as specified
S&F UPVC window,(unplastisized poly-Vinyl Chloride) sliding windows multi-chambered and stiffened framed windows using 88mm x 52mm size sections all-round as main frames and shutters made with profile sections of size 57mm x 42mm, including the cost and fixing of 5mm thick clear float glass in shutters and stainless steel wire mesh shutters shall have well defined welded corner joints without any gaps, fixed the window unit to the existing masonry with anchor fasteners as required. The shutters shall have necessary handles and other associated fittings to facilitate smooth operation. Both the frames and the shutters shall be reinforced with GI profiles of thickness 1.25mm the entire window is covered with MS powder coated tube of size 40mm x 20mm all-round the frame the frame section, 10mm square bars horizontally placed at 120mm C/C and suitably placed vertically to avoid buckling and providing structural strength, Minimum weight shall be 10kg/Sqm and fixed to UPVC frames with suitable fasteners. The gaps between the window frames and masonry walls shall be filled with silicon or with any other suitable filler materials complete all as specified and directed. Make : Rajshri Plastiwood/Veka/Sintex/Duroplast Extrusion Pvt. Ltd
M&L Complete removal of existing treatment on wall and applying Texture painting over a coat of primer over three coats of 3mm thick wall care putty all as per manufacturers instructions complete all as directed by Eng-in-charge.
M&L for fixed in repair 12mm thick Medium density fibre board, exterior grade, fixed to timber frame of bent or curved surfaces work fixed in flat or sloping with screws complete all as specified and as directed.
Taking down chowkats or frame with shutter, (without taking off shutter from the frame) exc 1.5 Sqm but n.exc 4sqm each and removing from site complete all as specified and as directed.
Taking down door chowkat or frame with shutter area n. exc 1.5 Sqm each (without taking off shutters from the frame) and removing to store complete all as specified and directed.
Taking down PVC Chowkhats or frames exc. 1.5 sq. m but n exc 4.0 Sqm each with shutters (without taking off shutters from the frames)
S & F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints incl MS hold fast & PCC for hold fast fixing with wall complete all as directed.
S&F 40mm thick Flush shutters solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 0.9 mm Decorative laminate type I of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturers instructions
S&F fancy type brass handles of size 200 mm long complete all as specified and directed
S & F 125 mm long cast brass with mild steel hinge pin, braight polished Butt hinges.
S & F 100 mm long aluminium Butt hinges complete all as specified .
S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section
S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised.
S&F of Brass 4 levers Mortice lock, vertical type, size 100 mm complete
S&F of aluminium extruded section Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S tubes of 19 gauge thickness and size of 20mm x 40mm for stiles as well as top, bottom & lock rail. M.S. frame shall have a coat of metal primer of approved make/ manufacturer. The inside panel shall consist of 20mm thick multichamber hollow PVC section of 1mm wall thickness, bonded using solvent cement / cyanoacrylate adhesive with 5mm (+0.25) thick moulded PVC sheet of density 600kg/Cbm manufactured by an ISO-9001-2015 certified company with 2,4,6 raised panel design in plain / prelam colours after routing the moulded design on one side of the inside panel. 5mm (+ 0.25) plain/ prelam PVC sheet to be pasted using solvent cement/cyanoacrylate adhesive on other side of the Hollow PVC section. All the edge of the panel to be sealed with lipping of 10mm thick & 20mm wide PVC sheet baton (made by sticking 2 Nos. foam PVC sheets of 5mm (+ 0.25) thickness using PVC solvent cement adhesive. Door edge lipping to be painted with PVC ink of matching colour of plain/ prelam moulded PVC sheet of door 20mm thick (5mm × 4 nos.) thick PVC sheet to be given for lock provision at lock height. Door to be fixed with frame with 3 nos. stainless steel butt hinges of size 100 mm x 2mm x 2mm and 50mm long steel screws drilled suitable to pass through both the walls of the M.S tube, other hardwares should be fixed with 25mm x 8mm size steel screws etc. complete all as per direction of engineer-in-charge.
S & F Solid PVC Door Frame of size 100mm x 60mm made out of 5mm WOOD GRAIN printed PVC sheet used instead of plain colour PVC sheet and edges will be painted to match with printed sheet, reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing
S&F Floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, fixed in floor complete
S&F 300mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed.
Fixing only 5.5 mm thick sheet glass in wooden frame area n exc 0.5 Sqm in stair case room.
S & F PVC connection 450 mm long and 15 mm dia., to flushing Cistern/ sanitary fittings with PTMT nuts connections at the ends complete.
S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule Complete all as specified.
S&F in repairs pillar taps of long shank fancy type chromium plated for 15mm bore pipes complete.
S & F 10 litres Capacity white coloured PVC flushing cistern low level with all accessories including taking down old flushing cistern complete all as specified.
S & F in repairs fancy type chromium plated 15 mm bore Stop valves, angle valves , cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F in repairs, Vitreous China wash down water closet pan (pedestal pattern), white (including fixing bolts and seat cover) etc. complete all as specified as directed by the Engineer-in-Charge.
S&F in repairs, vitreous China urinals, Half Stall type, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe, (excluding of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair chromium plated health faucet with 8mm dia and 1.2 m long flexible tubes and wall hook suitable for EWC including nut/washer complete.
Supply only 40 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed.
S&F in repairs stainless steel gratings for fixing 100mm dia outlet nahani including fixing with white/colour cement.
S&F in repair of liquid soap container complete.
S&F in repair chromium plated toilet paper holder with flap complete.
S & F in repair wash hand basin vitreous china white flat back of size 550x400 mm excluding taps,waste,chain and plug but including brackets incl cutting and for pinning in ends of brackets.
S&F CP Bottle trap for wash hand basin with complete fittings complete all as specified
S&F in repairs of Towel ring fixed on wall complete.
Taking down PVC (SWR) pipes (of any radius) including joints etc. complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 15 mm bore steel tubing and connections complete
Taking up or down 20 mm bore steel tubing and connections complete
Taking up or down 25 mm bore steel tubing and connections complete
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends of edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good , cutting not exc 10 cm girth
S&F of 15mm dia 3 Layer PP-R pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial welded having thermal stability for hot & colt water supply including all PP-R plain & brass threaded fittings complete all as specified and as directed.
S&F of 20mm dia 3 Layer PP-R pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial welded having thermal stability for hot & colt water supply including all PP-R plain & brass threaded fittings complete all as specified and as directed.
S&F of 25mm dia 3 Layer PP-R pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial welded having thermal stability for hot & colt water supply including all PP-R plain & brass threaded fittings complete all as specified and as directed.
Taking down rain water/soil waste/vent pipes including all fittings any size and pattern.
S & F 110 mm bore PVC (SWR) , waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches.
S & F 110 mm bore PVC (SWR) door bends of any radius.
S & F in repairs of PVC Rain water Pipes of Dia 110mm single socketed in any length with rubber ring joints fixed to walls including necessary fittings complete all as specified.
M&L Preparation of new or previously untreated steel Surfaces of any description, over 10cm in width or girth, not otherwise described, priming with red oxide, zinc chrome and applying two coats of synthetic enamel paint
S & F PVC (SWR) vent cowl 110mm complete all as specified and as directed by the Engineer-in-charge.
S & F 75mm PVC (SWR) multiple floor trap with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-charge.
S & F of 75mm dia PVC (SWR) bends any radius provided with access door complete all as specified and as directed by Engineer In Charge.
S & F in repairs PVC (SWR) gully trap 110 mm, setting and jointing with solvent cement complete all as specified and as directed by the Engineer-in-charge.
S & F PVC (SWR) Floor trap of 110 mm outlet plain with grating including jointing with solvent cement.
S & F 75 mm bore PVC (SWR) , waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches.
S & F Rotational moulded Polyethylene water storage tanks (Cylindrical vertical with closed top) 1000 litres capacity including all fittings like tank nipple, float valve etc and taking down of old one complete
S & F of PVC shoe for rain water pipe of 110mm dia complete all as specified and as directed
M&L for preparing old surfaces of ceilings by brooming down or by steel wire brushing and applying one coat of white wash.
M & L for complete removal of existing treatment on internal walls and applying two coats of Oil bound distemper over a coat of primer over wall care putty of 2mm thick all as specified and directed
M&L for complete removal of existing treatment on walls and applying two coats of Weather Proof Paint over a coat of primer complete all as specified and as directed.
M&L for repairs to ends of chajjas/ parapets by removing old concrete, loose material ,& cleaning of the reinforcement and finishing the surface fair & even in cement mortar 1:3 and making good with existing finishes all as directed by Engr-in charge.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat synthetic enamel paint all as directed.
M&L for preparation of new plastered wall surfaces and applying two coats of oil bound distemper paint over one coat of priming paint primer on internal surfaces of walls etc complete all as specified and directed.
M&L for preparation of old painted steel surfaces and applying two coats of synthetic enamel paint over one coat of red oxide primer.
M & L for preparation of new surface of walls and applying two coats of Exterior emulsion over a coat of primer for external surface on walls complete all as specified and as directed by the Engineer-in-Charge.
M & L for preparation of new plastered Ceiling surfaces and applying three coat of white wash complete all as specified and as directed by the Engineer-in-Charge.
S & F of Stainless steel Letters (Marine environment resistant grade) exc 15mm and not exc 30 mm height and of suitable thickness including SS fixing Screws Complete all as specified and as directed by the Engineer-in-charge.
S & F in repairs stainless steel pipe 25mm dia Curtain rod for Windows, doors opening etc
S & F in repairs Fancy type CP Knobs for fixing curtain rod all as directed and specified
Dismantling asbestos cement( corrugated, semi-corrugated etc) sheets in roof covering
S&F Pre- painted galvalume aluminium zinc coating GI based Mangalore Tile profile steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering for flat or arched roof cladding to wall, fixed with self tapping screws as specified
Taking down carefully existing aluminium conductor point wiring (light / fan / socket or power point) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc and removing materials from site and making good the disturbed surfaces of walls roof and floor etc as per existing specification complete all as specified and as directed.
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and fan regulators etc. for reuse at site complete all as specified and as directed. Note : To be measured only when found serviceable in all respects complete for reuse
Material and labour for point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing/New concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including new pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion complete including making good disturbed surface all as specified and as directed.
All as per Item no 99 here-in-before but for one light point controlled by two 2 way switch all as specified and as directed.
All as per Item no 99 here-in-before but for one E/Fan point controlled by 1 one way switch and regulator all as specified and as directed.
All as per Item no 99 above but for one 3 pin switch socket outlet, 5 Amp on independent board all as specified and as directed.
All as per Item no 99 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed
All as per Item no 99 here-in-before but for one 16 Amp 3 & 5 pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
All as per Item no 99 here-in-before but for one bell point controlled by one bell push on the same board with other switches or independent all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated un-sheathed cable with multi-stranded copper conductor of 6 sq mm size and drawing into and including concealed PVC conduit with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 6 sqmm, single core, as earth continuity wire all as specified and as directed.
Supply and fixing socket combination 2 in 1 3 pin 5 and 15 amp flush type universal all as specified and as directed.
Supply and fixing switch piano flush button single pole one way 5 amps all as specified and as directed.
Fixing only switch flush button single pole one way 5 amp all as specified and as directed. (Note : Material obtained from item No 98 here in before shall be used)
S&F switch flush type, single pole Two way 5 Amps 230 volts all as specified and as directed.
Supply and fixing socket combination 2 in 1 3 pin 5 amp flush type universal all as specified and as directed.
Supply and fixing Metal Clad plug & socket combination 2 in 1 3 pin 20 Amps universal all as specified and as directed.
Fixing only switch socket outlet 5 amp flush type all as specified and as directed. (Note : Material obtained from item No 98 here in before shall be used)
Supply and fixing ceiling rose surface bakelite three terminals all as specified and as directed.
Fixing only ceiling rose surface bakelite three terminals all as specified and as directed. (Note : Material obtained from item No 98 here in before shall be used)
Supply and fixing fan regulator electronic deluxe rotary step type all as specified and as directed.
Fixing only fan regulator any type all as specified and as directed. (Note : Material obtained from item No 98 here in before shall be used)
Material and labour for bell ding dong AC 230 volt single pole all as specified and as directed
Supply and fixing bell push, flush type 6 amps all as specified and as directed.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 6 way, Double door 415 Volts all as specified and as directed.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 4 way with dim rail earth and neutral bar all as specified and as directed.
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 100 amps, 415 Volts in proper position all as specified and as directed.
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position all as specified and as directed.
S&F in proper position MCB Double Pole of capacity up to 40 amps, 240 Volts C-series with 10kA breaking capacity all as specified and as directed.
Supply and fixing indoor luminaire decorative batten for wall/ceiling mounting box type energy efficient saving LED BATTEN LIGHT 10 W, 230 V, 50 HZ, slim integrated design easy install including twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed.
Supply and fixing indoor luminaire decorative batten for wall/ceiling mounting box type Extruded aluminium housing , PC Diffuser, energy efficient saving LED BATTEN LIGHT 20W, 230 V, 50 HZ, slim integrated design easy install incl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed.
Supply and fixing LED mirror light fittings 07 W, 230 V, 50 HZ suitable for indoor and outdoor applications complete all as specified and as directed.
Supply and fixing LED bulk head fittings 10 W, 230 V, 50 HZ suitable for indoor and outdoor applications complete all as specified and as directed.
Supply and fixing on wall security LED light luminaire fitting 1X25 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut,washer,clamp etc all as specified and as directed by the Engineer-in-charge.
Supply and fixing LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete
Taking down carefully ceiling fan any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades for safe custody for reuse and re-assembling the fan complete and refixing the fan in same position including all electrical connection all as specified and as directed.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for 1200mm sweep fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Supply only bearing No.6201/6202 for ceiling /Exhaust fan.
Supply only fan condensor upto 2.5 mfd.
Material and labour for painting of ceiling fans complete of any sweep/make with one coat of first quality synthetic enamel paint of approved tint by spray including preparation of old painted surface and removing all dust, oil mark etc and filling cavities with filler materials, and writing serial / MES number as specified (with paint of black colour with each letters/figures in Block of height n.exc2 cm ) complete all as specified and as directed.
S&F Exhaust fan wall mount type 300 mm sweep metal body , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
S&F Exhaust fan wall mount type 250 mm sweep PVC body , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for trench of FRLS cable etc and getting out in Soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed
Material and labour for sand cushioning for protection of underground FRLS cable consolidated and compacted with clean dry sand all as specified and as directed (Compacted thickness shall only be measured and paid)
Material and labour for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 35 Sqmm 3.5 core laid in trench /poles/on wall all as specified and as directed .
Supply and lay bricks common burnt clay building bricks sub-class B of size 230x113x75 complete all as directed by Engr-in-Charge.
Material and labour for galvanized iron tubing 50 mm bore light grade with all fitting for protection of FRLS cable, laid in trenches/wall/floor incl necessary clamp, bolt/nut if any all as specified and as directed. Note: Excavation ,earth work shall be measured and paid separately
Supply and Fix Rotational moulded polyethylene water storage tanks 500 ltrs capacity cylindrical vertical with closed top hoisted and fixed in position over roof top including foundation for water tank, complete all as specified and directed by the Engineer- in- charge
Supply and lay over wall or Surface medium class grade 20 mm dia GI pipes with all fittings laid in trenches complete all as specified and directed by the Engineer- in- charge .
Supply and lay over wall or Surface medium class grade 25 mm dia GI pipes with all fittings laid in trenches complete all as specified and directed by the Engineer- in- charge.
Drilling of hole horizontally 80/40 mm dia bellow the road for providing casing pipe of cable protection by using mechanical/hand drill
M & L for Earthing complete with galvanised steel earth plate electrode 600 mm × 60 mm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
VASANTHA NAIDU ASSOCIATES
SSV CONSTRUCTIONS
SWATHI CONSTRUCTIONS
SRI VENKATA SAI MANIKANTA CONSTRUCTIONS
SRI RAJA RAJESWARI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .