| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹44.8 L+₹4.4 L (10.9%)Admitted-Finance RZ GM 24 GALI NO 9 RAJ NAGAR II PALAM COLONY RAJ NAGAR PALAM COLONY SOUTH WEST DELHI DELHI 110077 | SOUTH WEST DELHI | DELHI | 110077 | L2 | Admitted-Finance | |
| 3 | L3₹45.1 L+₹4.6 L (11.4%)Admitted-Finance 475 1ST FLOOR NEHRU ROAD RAJARAJESHWARI NAGAR BANGALORE KARNATAKA 560098 | BENGALURU URBAN | KARNATAKA | 560098 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Thar Interiors L3 | Design unit interiors L1 | Vnext Works Pvt Ltd L2 |
|---|---|---|---|---|---|---|
| 1.00Civil Work | ||||||
| 1.01 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. | 99 | Sqm | 20,295 ₹23,948.1 | 14,850 ₹17,523 | 7,425 ₹8,761.5 Lowest |
| 1.02 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete | 150 | Sqm | 9,000 ₹10,620 | 3,900 ₹4,602 | 3,750 ₹4,425 Lowest |
| 1.03 | Removal of all types of false ceiling with frame work including stacking of servicable materials and disposal of unserviceable materials with all lead and lift work completed as per the instruction of EIC.Work complete including all type of tools, tackles, scaffolding etc complete as per instruction of Architect/EIC. | 99 | Sqm | 29,700 ₹35,046 | 12,969 ₹15,303.42 Lowest | 19,800 ₹23,364 |
| 1.04 | Removal of doors, windows with grill, ventilators, glazing, louvers, fix glass, window with top louves etc. (wood of steel) shutters , fabricated grill , including chowkhats, architraves, holdfasts and other attachments etc complete and stacking them within all lead and lift. work completed as per the instruction of EIC. | 5 | No. | 5,000 ₹5,900 | 3,000 ₹3,540 | 2,875 ₹3,392.5 Lowest |
| 1.05 | RCC Core cut : Drilling with core cutting machine in RCC beams,slabs,floorsetc.,for laying pipes and rendering the same in RCC 1:2:4 finishing the same to the satisifaction of the owner or his authorised representative etc.,including nominal reinforcement wherever required,complete,at all levels The quote shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes upto any depth at all heights & levels. Work complete including all type of tools, tackles, scaffolding etc complete as per instruction of Architect/EIC.a)100 mm dia | 3 | No. | 5,400 ₹6,372 | 3,600 ₹4,248 Lowest | 6,000 ₹7,080 |
| 1.06 | RCC Core Cut : b)150mm dia. | 2 | No. | 4,000 ₹4,720 | 3,600 ₹4,248 Lowest | 5,000 ₹5,900 |
| 1.07 | RCC Core Cut : b)200mm dia. | 1 | No. | 3,000 ₹3,540 | 2,500 ₹2,950 Lowest | 3,000 ₹3,540 |
| 1.08 | Flooring Work : Providing and laying Lapato/ Matt /Glossy/ Non skid,/Rustic finish/sugar finish Vitrified tiles in dado using minimum 10 mm thick tiles as per approved make list by architect /client (size 600 mm X600mm) fixed in dado on 10 mm th. Cement plaster 1:3 (1 cement: 3 coarse sand) All surfaces must be dimensionally stable according to IS 1443-1972, level, cured, undamaged, compact,rigid,resistant, dry and free from any debonding agents tiles fixed by approved tile adhesive and all application shall be done under instruction of manufacturer guideline and specification , and jointed with 3mm thick epoxy grouting as per approved make of approved shade and colour in proper line and level as per detailed drawing / instruction all complete as per approved sample by Architect, drawings and instruction of EIC. at all floors / all levels / all heights and all shapes. | 100 | Sqm | 1,80,000 ₹2,12,400 | 1,57,500 ₹1,85,850 | 1,47,500 ₹1,74,050 Lowest |
| 1.09 | Applying general insecticide pest control treatment to floors, cupboards etc including labour material etc. complete. Using Heptachloride 20 EC. As Per 6113_pests Consentration Weight 0.50 percent is recommended one litre chemical emulsion dillute with 39 liter of water will give. Total dillute concrentration will be 40 litre inclusive of one litre chemical emulsion appication 0.5 Litre chemical / Sqm of surface is recommended as per I.S. | 179 | Sqm | 72,495 ₹85,544.1 | 25,597 ₹30,204.46 Lowest | 44,750 ₹52,805 |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
3 Mar 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director NIFT Gandhinagar
NIFT Gandhinagar
Tender for Upgradation of Classroom at NIFT- Gandhinagar
2025_NIFT_848323_1
NIFT-GNR/Building/ Upgradation of Classroom /2025-26
Open Tender
Civil Works
Works
180 days
NIFT Gandhinagar
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹2 L
Yes
29 Apr 2025
10 Feb 2025
4 Mar 2025
10 Feb 2025
3 Mar 2025
10 Feb 2025
Civil Work
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Removal of all types of false ceiling with frame work including stacking of servicable materials and disposal of unserviceable materials with all lead and lift work completed as per the instruction of EIC.Work complete including all type of tools, tackles, scaffolding etc complete as per instruction of Architect/EIC.
Removal of doors, windows with grill, ventilators, glazing, louvers, fix glass, window with top louves etc. (wood of steel) shutters , fabricated grill , including chowkhats, architraves, holdfasts and other attachments etc complete and stacking them within all lead and lift. work completed as per the instruction of EIC.
RCC Core cut : Drilling with core cutting machine in RCC beams,slabs,floorsetc.,for laying pipes and rendering the same in RCC 1:2:4 finishing the same to the satisifaction of the owner or his authorised representative etc.,including nominal reinforcement wherever required,complete,at all levels The quote shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes upto any depth at all heights & levels. Work complete including all type of tools, tackles, scaffolding etc complete as per instruction of Architect/EIC.a)100 mm dia
RCC Core Cut : b)150mm dia.
RCC Core Cut : b)200mm dia.
Flooring Work : Providing and laying Lapato/ Matt /Glossy/ Non skid,/Rustic finish/sugar finish Vitrified tiles in dado using minimum 10 mm thick tiles as per approved make list by architect /client (size 600 mm X600mm) fixed in dado on 10 mm th. Cement plaster 1:3 (1 cement: 3 coarse sand) All surfaces must be dimensionally stable according to IS 1443-1972, level, cured, undamaged, compact,rigid,resistant, dry and free from any debonding agents tiles fixed by approved tile adhesive and all application shall be done under instruction of manufacturer guideline and specification , and jointed with 3mm thick epoxy grouting as per approved make of approved shade and colour in proper line and level as per detailed drawing / instruction all complete as per approved sample by Architect, drawings and instruction of EIC. at all floors / all levels / all heights and all shapes.
Applying general insecticide pest control treatment to floors, cupboards etc including labour material etc. complete. Using Heptachloride 20 EC. As Per 6113_pests Consentration Weight 0.50 percent is recommended one litre chemical emulsion dillute with 39 liter of water will give. Total dillute concrentration will be 40 litre inclusive of one litre chemical emulsion appication 0.5 Litre chemical / Sqm of surface is recommended as per I.S.
Gypsum FR/MR Ceiling : 30 Min. M/F Suspended 30min Fire Resistance ceiling includes Gypserra™ Perimeter Channel {Material-GI(IS513),YS-260Mpa,Finish- Galvanised 150GSM(IS27 )} is fixed along the perimeter of existing wall/ partition with the help of HILTI HPS - 1 (6x40) impact anchor, at 600mm centres. Gypserra™ Ceiling Angle {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is suspended by fixing it to the Gyproc® soffit cleat {GI(IS513)YS-260Mpa,Finish-Galvanised 150GSM(IS277) }. Soffit Cleat and Gyproc® Rawl Plug- Ø8x45mm {Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1220mm x 1220mm grid. Gypserra™ Intermediate channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277) } is fixed to the Gypserra™ Ceiling Angle with M6 x 12mm Hex Bolt & Hex Nut arrangement {Material–As per EN 10083 Finish – Zinc Plating} or with 2 Nos of Ø4.2x13 Gyproc® metal to metal screw {Material-Carbon steel EN-ISO 7049/50 Finish- Zinc Coating Thickness- 4.14micron.} The Gypserra™ Ceiling Section {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is then fixed to the Gypserra™ Intermediate Channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} with the help of Gyproc® Connecting Clip {Material-High carbon spring steel wire(BS970Gr.En42)-46-48HRC,Finish- Zinc plating 4-6 micron} and in direction perpendicular to the Intermediate channel at 457mm c/c. Use 50mm thick rockwool above celing for fire insulation, then Single layer of 15mm tapered edge Gyproc FRMR Board as per (EN 520:2004, Type F & H1.ASTM C1396, Type X) is then screw fixed to ceiling section with 25mm drywall screws {Material-Carbon steel EN-ISO 7049/50,Finish-Case hardened Grey Phosphating} at 230mm centres on ceiling section & 150mm at periphery of ceiling. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc® Easy-fill 90 Jointing compound (Conforms to ASTM C475), Gyproc® Joint Paper tape. Serrated section has effective thickness of 2T ( 2xdepth), better load carrying capacity. The item includes providing and fixing trap door of size 600 X 1200 mm as per approved sample of Ceiling panels comprise of a powder-coated beaded steel frame with gypsum / plywood board door. Each panel features a push- latch closing mechanism with door retaining safety cable & hook.Suspenders from ceiling to support the frame and trap door firmly along with necessary hilti fastner, cleats, screws, angles, packing, etc. complete work. Necessary cutting / providing openings in the ceiling for AC fixtures, grills, electrical fittings, or other utility services, hatch openings etc. shall be provided by the Contractor and cost of making such modifications shall be included in the price.
Grid Ceiling : Providimg & Fixing of Eco- Friendly Light weight Calcium Silicate Ceiling .Providing and Fixing False ceiling at all heights 100% Eco Friendly , Non Cementitious light weight calcium silicate false ceiling tiles having having 15 mm thick integral densified edges (for extra Strength ) reinforced with Eco-friendly fibres and natural filler with a eco-friendly recycled content of more than 50% ( For Green Building Leed Accreditation) . False ceiling tiles of Size 595x595 mm of approved texture, design and patterns Viz Spintone/ Cosmos/ Spectra /Globe/Hexa/Quadra having NRC (Noise Reduction coefficient) 0.50 to 0.75 (for semi perforated and fully perforated range of tiles), Light reflectance of 85% (minimum) . Non-combustible as per BS: 476 (part-4), fire performance as per BS: 476 (part 6 &7 (High Fire resistivity for very high fire safety), humidity resistance of 100% RH ( Suitable for any weather conditions) , Thermal conductivity of 0.050 W/m°KC to 0.050 W/m°KC as per IS 3346/1980 (High Thermal Insulation). 100% Antifungal , Antibacterial, Anti termite.The ceiling Tiles should be free from Chemicals, asbestos having Zero VOC Property for better indoor Air quality The tiles shall have average body density of 370 kg/m³ as per ECBC code 2007 and average edge density of 450 Kg/m3. The tile shall be primer coated on both sides and the fair surface shall be having a factory finish in two coats of white dispersion type solvent free paint.The framework shall be suspended from ceiling by slotted cleats of size 25X35X1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre The tile shall be laid on 24x38mm wide T section flanges colour white having rotary stitching on all T sections, i.e., the main runner, 1200 mm & 600 mm cross tees with a web height of 38mm & load carrying capacity of 11-13kgs/Sqm. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge/Manufacturers Specification.Necessary cutting / providing openings in the ceiling for AC fixtures, grills, electrical fittings, or other utility services, hatch openings etc. shall be provided by the Contractor and cost of making such modifications shall be included in the price. No separate charges for cutting / providing opening will be paid. Trap doors with necessary ply frame workto be provided as required at no extra cost. Work complete as per the detailed drawing and instruction of Architect/EIC.
Wall Punning : Providing and applying Plasto XP Gypsum plaster ( USG Boral or superfine) minimum 12 mm thick in Wall and minimum 6 mm thick in ceiling , including all labors, tools, tackles, scaffolding, surface preparation, mixing of material, transportation (lead & lift) applying in position, Levelling, finishing, cleaning etc. complete to satisfaction of EIC. The rate also include making of grooves above skirting, dado tiles and around window and door jambs etc. (cost of Bonding agent to the ceiling or RCC surfaces is to be included in the item).item shall be used as per instruction of Architect .
Metal ceiling : Galvanize Steel Sheet 600X600mm Panel (Galvanized Steel): Metalium make Galvanize Steel Sheet 600X600mm are made from 0.6 mm TCT Galvanized Steel as per IS-513 coil / powder coated on a continuous paint line easily removed without the aid of special tools. Paint Detail: Coil coated / Powder Coated Sheet shall be chromatized for maximum bond between metal and paint, enamelled twice under high temperature, one side with full primer and finish coat, the other side (Inner side) with a primer coating and skin coat on continuous paint line or Powder coated panel shall be 50 microns thick on exposed surface. Perforation Details: 3 inch dia, 150mm Centre to Centre in Regular Pattern. Installation: To comprise, 1.2 mm. thick Aluminum Section spaced at 600mm Center to Center Horizontal line sheet length direction fixed to the slab / truss by main support not more the 1 ft. at 1200mm center to center. Then installed GI Sheet in fixed with screw in to the aluminum section. Rate shall inclusive cost of making of all cutouts for light fixtures, gadgets, gizmo, pelmets, grooves, beads and also provide support/template where ever required.The rate shall be in sq.mt for all floors and at all heights including all costs . ( considering all levels with require all Framing work and fitiing from RCC slab to false ceiling level).
Interior paint : Providing & laying of three coats with Royale luxury Emulsion paint of Asian Paint or equivalent approved brand in shades and colour as directed on wall surfaces to give an even shade incl. scaffolding to at any height with all labour and material after thoroughly brushing the surface & making free from mortar dropings and other foreign matter including surface preparation etc.complete. Including cost of all type of tools, tackles, all labour, materials, transportation, cleaning , at all floor, all level, all depth, all Height, all lead and lift , performance waranty certificate etc. work complete as per the detailed drawing, approved sample, specifications and instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC. The substrate must be sound, clean, dry, free from dust, oil, grease and laitance etc. All traces of release agents must be removed. On chalky and dusty surfaces, all loose material must be removed by stiff bristle brushing. The primer / paint application is to be done with the rollers. rate shall be including crack filling and levelling as per manufacturers specfication.
Single Leaf Flush Door with ply frame and finish with laminate : Providing and fixing in position 40 mm thick solid core wooden single leaf flush doors of approved make having fire retardant ply facing on both sides and finished with laminate as approved , frame size - 100 X 50 MM , polishing work , Hardware system of Geze/Dorma like . work complete including all type of hardware, fittings , fixtures, ply frame covering with finish & polish etc complete as per detailed drawings and specifications. Basic Rate for material only laminate -50/Sqft.
Single Leaf Glass Door: Providing and fixing in position full height 10mm thick toughened glass STL45 Door System with 6063-T6 grade duly Anodized Aluminium Sections having sizes of 45x55x1.5mm thick, 10 mm Toughened Glass including Assa Abloy Door Closure, Hinges, SS Handle (H Type 450mm), SS Bottom Lock, Thermoplastic Gaskets & Screw Caps all necessary hardware of as per approved make by Architect. 10mm thick Saint Gobain make customized clear toughened glass.Work complete including all type of material, fittings , fixtures,Finish, loading , unloading , transporation, all leads ,accessories, sample mockup, all floor , all levels, all heights , necessary frame work,Scafffolding etc complete as per detailed drawings ,specifications & instruction of Client/EIC.
Frosted sparkling glass film : Providing and fixing frosted glass film of approved make Translucent, cast PVC, self-adhesive vinyl, special CRYSTAL-effect film to reproduce Sand-blasting effect on glass with customised designs. MCS warranty of 3 (if exposed to direct sunlight) to 10yrs (indoors) must be endorsed by manufacturer. Rate shall be inclusive plotter cutting design as per Architect/Client suggestion. Contractor shall provide shop drawing for approval of Architect/Client.work complete incuding all type of tools, tackles, scaffolding etc complete as per suggestion of Architect/Client. If in case any application finishing will not as per satisfaction contractor shall remove all film at their cost. Contractor shall do a sample mock of 5 Sqm minimum of glass film) ,shall be approved from Architect/Client.
Accoustic Panelling : Providing and fixing Accoustic Panel board 9 mm thick Artois /Aerolite/ Ecotech as per approved make & Sample by Architect/ Client. Supplying Marco Polyester Fiber acoustic wall paneling.Thickness:- 9 MM Density:- 200 kg/m3 , NRC: - 0.75 @ 125-4000 Hz Noise. Fire performance:- Class A , Accoustic board fixing on wall directly with SR 505 Adhesive or otherwise fix on 6 mm thick base ply & framing work . Work Inclusive of Cutting as per detailed drawing and instruction of Architect. Including surface preparation, Including cost of all type of tools, tackles, all labour, scaffolding, transportation, cleaning, at all floor, all level, all depth, all Height, all lead and lift etc. etc.work complete as per the detailed drawing, approved sample, specifications and instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC.Only the clear elevation area shall be measured and paid.
Accoustic Panelling : Providing and fixing Accoustic Panel board 12 mm thick Artois /Aerolite/ Ecotech as per approved make & Sample by Architect/ Client. Supplying Marco Polyester Fiber acoustic wall paneling.Thickness:- 12 MM Density:- 200 kg/m3 , NRC: - 0.75 @ 125-4000 Hz Noise. Fire performance:- Class A , Accoustic board fixing on wall directly with SR 505 Adhesive or otherwise fix on 6 mm thick base ply & framing work . Work Inclusive of Cutting as per detailed drawing and instruction of Architect. Including surface preparation, Including cost of all type of tools, tackles, all labour, scaffolding, transportation, cleaning, at all floor, all level, all depth, all Height, all lead and lift etc. etc.work complete as per the detailed drawing, approved sample, specifications and instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC.Only the clear elevation area shall be measured and paid.
Soft Board : Providing and fixing on wall 12mm thick approved quality soft board with cotton cloth/fabric of approved make and shade on 12mm thick IS 710 ply 50 mm th approved Glass wool sheet with PVC grip , as approved sample and as directed by EIC. The work shall be measured & paid in Sqm. for all floors, all level and at all heights including all costs .Only the clear elevation area of the cloth/fabric shall be measured and paid. All the work complete as per the detailed drawing , mockup sample and instruction of Architect/EIC.Basic rate of cotton cloth /fabric for 54" wide shall be Rs. 200/Rmt.
Blinds : Providing and fixing as per approved make manual roller blinds with Soltis fabric & spring drive system with steel ball chain/onetouch with speed control action roller blind with end brackets with head ail, components, bottom bar.Color-Alu with manual operation and warranty etc as per manufacturer’s specifications. Fabric to be as per approved sample. All the work complete as per the detailed drawing and instruction of Architect/EIC. Soltis-99-Color-Alu fabric: 39% Polyester/61% PVC with Aluminium Backing. Weight:290 g/sqm, Thickness:0.32 mm, Openess Factor:3%, Visible Light Transmission (N-N): 2%-4%, Solar reflection (white) 65%, Internal Solar Factor (gtot): 0.35 - 0.48, Tensile Strength (Warp/Weft):160/170daN/5cm,Tearing Strength(Warp/Weft):11/13daN, Fungistatic Treatment:Degree 0, Excellent (EN ISO 846-A) Fire Retardancy:B-s2,d0/EN 13501-1. All complete as per approval of designer & instruction of Project Manager. (The mode of Measurement: The size of the blind will be measured from end to end bracket (Left to Right bracket) & height will be measured from top of the pelmet till the bottom of the bottom bar
Blackout curtain : Providing and fixing Fabrics to be as per approved sample.- Soltis-B99 or equivalent approved make - Soltis-B99 blackout: Solar, Light & UV transmission: 0%, Solar reflection (white) 69%, Weight:540g/sqm, Thickness:0.47 mm, Tensile Strength (Warp/Weft): 160/170daN/5cm, Tearing Strength(Warp/Weft):11/13daN, Fire Retardancy: B1/DIN 4102-1, Euro class B-s2,d0 . All complete as per approval of designer & instruction of Project Manager. Work completed as per the detailed drawing and instruction of Architect/EIC. (Contractor shall provide treated wooden pelmet complete as per seperate item in all respects on which all blinds shall be fixed and should also take load of the motor) Providing & installation of Electrical Motors for movement roller blinds with specification of Somfy, France, Power supply (VAC/HZ) : 220/50, Absorbed power (W): 170, Torque (NM): 5 Speed Rpm: 29, Rated running time: 4 min. current - 0.77 (A) with Hardware for Motorized blinds with end brackets, bottom rail, aluminum pipe, Insert tape, endcap & 2 sided tape with remote of Somfy make with RF frequency to opeatre 6 blinds with one remote & RF receiver of Somfy make for communicating.
Staging with V board with metal framing: The framework shall be prepared from RHS metal section of size 50 mm x 25 mm x 2.0 mm fixed approximately at spacing not more than @ 450 mm c/c both ways. At the joint of cladding material, two back to back metal members of size as specified above shall be provided and shall be supported by filling required size wedges / washers / MS wall connectors or packings of washers to ensure right angles and plumb level. The framing shall be fixed with the walls and/or floors (for floors, the framing shall be fixed to the concrete surface and not flooring mortar) by nylon grip screws of approved make and sample. The frame work shall be measured in sqm of elevation and/or floor area. The face of the panelling shall be finished with 18 mm thick Fiber cement board (V-board). Rates shall be inclusive of cost of making cut outs / openings for electrical fixtures, tube lights etc. & providing additional sections for strengthening the openings / cut-outs, as per drawing or instruction of EIC. Area of cut-outs shall not be deducted and no extra payment shall be considered for additional sections provided.
PVC FLOORING - 3 MM Providing and laying PVC/Vinyl flooring of 3 mm thickness, using Wonderfloor vinyl flooring, Indag vinyl floor tiles, LG vinyl tiles, Classic vinyl flooring or equivalent, as approved by the Architect, in desired pattern and design, in required shade and finish, with proper rubber based adhesive solution, such as Dunlop S-758 , pidilite SR or equivalent. The rate includes making seamless joints and cleaning the flooring etc. complete, as directed.
Full Height Storage: Providing, making, polishing and fixing full-height storage of size 450 mm depth as per reference drawing. Material of Construction: 1) Top: 19 mm thick BWR ply finished with 1 mm thick laminate sheet of approved shade, finish and make. Ply shall confirm to IS 303. 2) Storage Base: The table legs shall be made by 19 mm thick BWR ply confirming to IS 303 to be finished with 1 mm thick laminate of approved make, shade and texture as per reference drawing. 3) Sides: The sides shall be made by 19 mm thick BWR ply confirming to IS 303 to be finished with 1 mm thick laminate of approved make, shade and texture as per reference drawing. 4) Partitions: Horizontal and vertical partition shall be made of 19 mm thick BWR ply and shall be finished with 0.8 mm thick laminate of approved make, shade and finish. 5) Lipping: 6 mm thick lipping of ghana teak wood shall be applied on all exposed edges of veneer and ply as per reference drawing. 6) Polish: Monocoat polish shall be done on all exposed faces of wood and veneer. 8) 0.8 mm thick balancing laminate of approved make, shade and finish to be applied on all inner faces of top, bottom, sides, shutters, drawers, shelves and partitions as per the instruction of Architect. 9) Hardware: Hinges: L Hinges of size 75 mm x 18 mm shall be used in requisite quantity as approved by the engineer-in-charge; Magnet Lock: 2 Nos. per active shutter; Shutter stop chain: 1 no. per shutter; Handles: G - profile handles of approved. The work shall be done as per the approved shop drawing (to be prepared by contractor), specifications, sample approved and as directed by the Architect and Engineer-in-charge. The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools & tackles,adhesives, consumable hardwares & required SS 304 grade hardware/accessories of approved make (if applicable) for all floors, all heights, all levels and all places within campus. Contractor shall do all the needful and shall fulfill Architect''s design intent. No additional claims will be entertained for this. The unit shall be manufactured in parts and these parts shall be assembled at site.
Wepaint Whightbord Marker Paint
Dressing Mirror with 3k/4k Lighting Bulb:Providing, making, fixing mirror 4 mm thick beveled edge finish mirror fixed on BWR IS 303 ply by approved adhesive with necessary solid wood frame work with polish , Light Bulb with nesesary fitting as approved by architect with all nesesary work.c complete as per attached ref image and drawing. The work shall be done as per the specifications, sample approved and as directed by the Architect and Engineer-in-charge. .Rate shall inclusive of providing mock up sample for approval of architect.
Puffy : Structure made from flexiply with necessary teak wooden framework, and finished with 40density with PUFoam with fabric finish. The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools & tackles, approved make for all floors, all heights, all levels and all places within campus. Basic rate of fabric Rs. 500/Rmt Work complete including all type of material, fittings , fixtures,Finish, loading , unloading , transporation, all leads ,sample mockup, all floor , all levels, all heights etc complete as per detailed drawings ,specifications & instruction of Client/EIC.
Signages : Providing and fixing signages comprising form ss plate with Vinyl film letter , MDf finish or SS plate with 12 mm thick coloured glass as per instruction of Archiect/EIC. Contractor shall submit mock up sample.(Size-450x150mm)
Carpet Flooring Work: Providing & laying Tile base carpet flooring as per approved make & Sample approved by Architect. Fixing : fixed with SR 505 Pidilite or equivalent tile adhesive and underlay foam as per approved sample. Surface Preparation : The floor which receives the carpet to be thourougly cleaned as per manufacturer''s. specifications. Before laying of the carpet, the executing agency will level the surface with plaster of paris wherever required. The carpet is to be laid over a bed of manufacturer''s approved adhesive spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a location as directed. The laid carpet to be vacuumed after the removal of protective cover/on commissioning. If after the protective layer is removed and stains observed in the carpet because of in adequate protection, the same shall be shampooed and made good to the satisfaction of the Architect / Client. The measurements of carpet will be the actual laid area. Work including where ever required SS 304 grade End profile/Edge profile/ Skirting .Contractor will take care for level matching with other area flooring. Work complete for at all floor, all level, all depth, all Height, all lead and lift etc. work complete as per the detailed drawing, approved sample, specifications and instruction of Architect/EIC.Sample mock shall be approved from Architect/EIC. Basic rate of carpet is 250/Sqft
Dismentaling,Shifting And Re.Instalation of eixsting furniture,Electrical,ELV ( Any item) : furniture , fixtures ,Electrical,ELV all items / all type of equipments , of existing after wrapping the same in bubble wrap, thermo coal etc to the NIFT Classroom Building as directed by Eng. (NIFT). Work complete inclusive of all loading , unloading , material, labour, necessary tools & tackles,transporation , all floors, all heights, all levels and all places with necessary skilled manpower. If required Contractor shall visit the site for existing Area.
Full Height Partition Gypsum Partition :Providing & Fixing 120mins (as per BS 476 Part 22) Fire Rated Partition System of 75 mm thick GypSerra™ C-STUD partition which includes double layer of tapered edge 12.5mm thick Gyproc® Fireline Board (conforming to IS 2095 Part 1:2011) of size 1219 x 2438mm is screw fixed to Galvonium C-stud. 48x0.5mm Gypserra™ C-STUD {Material-IS 513, Y/S-300Mpa, Finish - Al-Zn coating 150gsm (IS 15961)} placed at 610mm c/c in 50x0.5mm Gypserra™ {Material-IS 513,Y/S-300Mpa, Finish - Al-Zn coating 150gsm (IS 15961)} floor and ceiling channel. Floor & Ceiling channel is anchored to the floor & True ceiling using Gyproc® Rawl plug Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-6.8kN for M30 concrete grade} /Hilti X-GN20MX anchor fasteners at 600mm c/c in center line. 12.5mm thick Gyproc® fireline board strip of 100 mm width is placed between ceiling channel and RCC ceiling slab to improve fire performance of the system. A Gypserra™ noggin channel {Material-IS 513,Y/S-300 Mpa, Finish - Al-Zn coating 150gsm (IS 15961)} of 48x0.5mm width has to be provided at the horizontal joints of the two boards. First layer of Gyproc® boards to be screw fixed with Gyproc® drywall screws of 25mm at minimum spacing of 600mm at centre and 600mm at periphery. Second layer to be screw fixed Gyproc® drywall screws of 35mm at minimum spacing of 300mm at centre and 300mm at periphery. 25mm Glass wool slab of density 24kg/m³ shall be placed in metal framework. Glass wool/ Rock wool holding clip should be used to hold Glass wool slab in its position. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc® Pro-Fill Jointing compound (Conforms to ASTM C475), Gyproc® Joint Paper tape. The junction of the partition with masonry & all penetration through the partition has to be treated with Hilti/Pyroplex/equivalent fire and acoustic sealant. The framework has to be done from finished floor up to soffit. All other detailing and specifications to be followed as per approved drawing of Gyproc. Contractor has to submit system 2 hr fire rated partition certificate from Gyproc.Rate shall include cost of making of all cut-outs for light fixtures, switchboards gadgets, gizmo, pelmets, grooves, beads and also provide support/template where ever required & For door frame fixing and storages ,shelves,paneling Wooden members to be used shall be of CP teak wood only. Including skirting /MDF board/wooden skirting cut out as per EIC instruction at siteThe rate shall be in sq.mt for all floors and at all heights including all costs. The rates are also inclusive of necessary scaffolding, tools, tackles, Internal partial support (between two sturd) at 7'' height.The shop drawing (or a sample mock of 5 Sqm minimum of the frame work and partition) shall be approved from EIC and Architect. All exposed corner shall be covered with perforated angle as per manufacturer''s specifications or as directed by EIC.Fire rating - 120 min-Acoustic Rating In (Rw dB)-49 .
Gypsum panelling :The M/F wall lining includes 12.5mm Gyproc® Quattro Gypsum Board, screw fixed with drywall screws of 25mm at 300mm centers to one side of 45X18X0.5mm Gypliner ceiling channel (0.5mm thick having 18mm flange each made of GI Steel) placed at 600mm center to center in 195X29.5X0.9mm fixing bracket at 900mm c/c with 25X25X0.5mm Gypliner angle at bottom and top of the channel such a manner that joints staggered to avoid leakage through joints. Fixing strip of 75X0.5mm should be installed at horizontal joint of boarding. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound and Joint Paper tape. 50mm Glasswool of density 20kg/m3 should be placed in metal frame.Necessary fabrication with anticorrosive paint work , scaffolding, anchor fasting , bolting HILTI or equivalent make with testing certified in scope of contractor)Rate shall include cost of making of all cut-outs for light fixtures, switchboards gadgets, gizmo, pelmets, grooves, beads cut out as per EIC instruction at siteThe rate shall be in sq.mt for all floors and at all heights including all costs. The shop drawing (or a sample mock of 5 Sqm minimum of the frame work and partition) shall be approved from EIC and Architect.Panelling item including openable shutter wherever required area and finish with the same material. Only the clear elevation area shall be measured and paid.
Providing and fixing screen Curtain: Providing & fixing screen comprising fromMS/Aluminium Chanel with Fabric and requred ply framing and alluminium frame work finish with combination Acoustic etc as per detail drawing and screen instalation including fixing from slab level & floor level also with necesory framework and groutingwork etc. Rate to be inclusive of cutting, wastages, necessary fixtures, nails, adhesives, necessary scaffolding, fixing at all heights and for all floors as per drawing and approved sample etc.
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete,Cat. III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires erected in below type of pipe with 6A Modular type switches and following type of accessories erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete, Cat. III
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling complete with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted and accessories with earth continuity of following type erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete,,Cat. III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories.[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete, erected flushed on wall/ceiling completeCat. III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete, erected flushed on wall/ceiling completeCat. III
Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling with following type accessories,Cat. III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge.(7) Blank Plate Single ,Cat.III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge.(9) 16 Amp. SP one way switch ,Cat.III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge.(10) 6/16Amp. Universal socket ,Cat.III
Providing & erecting Switch board for Computer or electric apparatus consisting of following modular type accessories mounted with PVC / Metallic concealed/open box with single mounting base frame covered with textured/metallic /white front plate,modules erected with necessary connections as directed 1 no. 6A/16A universal plug-switch combined. 3 nos. 6A Switch 3 nos. 6A 5 pin Plug ,For Modular Type Accessories, Cat. III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge.(11) 6 Amps. Bell PushCat. III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge.(3) Two Pin/RJ-11 Telephone Socket,[A] For One Gang,Cat.III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge.(8) Computer RJ-45 socket ,Cat.III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge.(4) TV Co-axial Socket outlet ,Cat.III
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed ,(a)20 mm
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed ,(b)25 mm
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed ,(c)32 mm
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid material with ignition free and flame proof confirming BS with necessary end caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following sizes,(2) 100 mm x 50 mm trunking
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl, chloride rigid material with ignition free and flame proof confirming BS with necessary end caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and measuring of following sizes,(3) 50 mm x 50 mm trunking
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes.(1) 20 mm
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes.(2) 25 mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size ,(A) With medium class Rigid PVC pipe and accessories,(a) 2 wire 1.5 sq. mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size ,(A) With medium class Rigid PVC pipe and accessories,(b) 2 wire 2.5 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size(A) with medium class Rigid PVC pipe and accessories,(a) 2 wire 4 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size(A) with medium class Rigid PVC pipe and accessories,((h) 4 wire 6 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size(A) with medium class Rigid PVC pipe and accessories,(i) 4 wire 10 sq. mm (use earth wire of 4 sq.mm )
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required.(e) One wire 6.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required.(f) One wire 10.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required.(g) One wire 16.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required.(h) One wire 25.00 sq. mm
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction,[C] CAT - 6
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation.(b) RG-6
Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI marked copper wires of following size to be erected as directed.(e) 1.50 Sq.mm 3 core round PVC sheathed
Supplying & erecting Approved make call bell indicator with buzzing sound and Red light indicating lamp with Red light button to attend the call suitable for 240 v 50 c/s supply to be erected.
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for(A) single phase incoming and horizontal single phase outgoing(b) sheet steel double door (IP-43)(iv)12 way
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed, (ii) 40Amps. DP , Cat. III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity(b)40 Amp. Cat.III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity,(c)63 Amp.,Cat.III
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity ,(A) 6 to 32 Amp. Cat.III
Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB.
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark , Cat.III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only Cat III
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(B) 4 core 16 Sq. mm
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable A)50 mm outer dia
Providine and erectg window Software supproting as per interactive Disply for windows operating .
Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover.(approved make OEM has to submit test certificate including value of earth resistane of installation.[A] For electrical installation up to 440 V Length of Pipe - 1 Mtr Back filling compound - 1 Nos. of Bag of 15 Kgs.
Providing and erecting Annealed bare Copper wire 8 to 16 SWG.
Supplying and erecting led lamps with following wattage capacity of 220 to 240 voltage, minimum 15000 burning hours life, 500 V in built-surge protection,Polycarbonate diffuser, mounting suitable for E14 / E27 / B22 lamp holders, pf >= 0.5,(ii) 5 to 8 watts,Cat-III
Supply, Installation, Testing & Commissiong of 1/2.8” Dome 2 Megapixel progres sive CMOS, NUMBER OF PIXELS (H × V) 1920 x 1080, MINIMUM ILLUMINATION 0.05lux/F1.4(color, 30IRE) 0Lux/F1.4(IR on), S/N RATIO More than 45dB ELECTRONIC SHUTTER SPEED 1/3~1/100000s, IR DISTANCE Distance up to 30m(98ft) IR LIGHT CONTROL Manual/SmartIR/OFF, IR LIGHT NUMBER 2 DAY/NIGHT Auto(ICR) / Color / B&W BACKLIGHT COMPENSATION BLC / HLC / WDR WHITE BALANCE Auto/Natural/Street Lamp/Outdoor/Manual/Customized Region GAIN CONTROL 0~100 WIDE DYNAMIC RANGE 120 dB, NOISE REDUCTION 3D DNR MAKE: Honeywell/Bosch
Providing and erecting Outdoor unit for Split A.C. Machine unit consisting following component (1) Air Cooled Condenser unit having minimum face area of 0.235 Sq.Mtr. made out of 27 / 30 gauge copper tube and cover with Aluminium fins of12-13FPI with 3/4 Row deep (2) Approved make new power saver rotary sealed type compressor suitable for operation on 220/23OV. 50 c/s. A.C. supply for Split type A.C Machine (3) Suitable Size of condensor motor for operation on 220/23OV. 50 c/s. A.C. supply with fan blade and require running and starting capacitor (4) Suitable Size of Copper capillary tube of 0.055''/0.060''/0.064'' bored for Split A.C.Machine(B) For 5 star Rating(b) For 1.5 TR A.C. Machine
Providing and erecting Outdoor unit for Split A.C. Machine unit consisting following component (1) Air Cooled Condenser unit having minimum face area of 0.235 Sq.Mtr. made out of 27 / 30 gauge copper tube and cover with Aluminium fins of12-13FPI with 3/4 Row deep (2) Approved make new power saver rotary sealed type compressor suitable for operation on 220/23OV. 50 c/s. A.C. supply for Split type A.C Machine (3) Suitable Size of condensor motor for operation on 220/23OV. 50 c/s. A.C. supply with fan blade and require running and starting capacitor (4) Suitable Size of Copper capillary tube of 0.055''/0.060''/0.064'' bored for Split A.C.Machine(B) For 5 star Rating(a) for 1.0 TR A.C. Machine
Supplying and erecting insulated pair of soft copper tubing open or concealed including power and control cable,necessary PVC drain pipes for Split AC machine up to 2 TR capacity
Dismental and reinstalltion of exisiting casste ac unit with dry/wet service as per instruction engineer incharge,
Supply and Installation of Networking through Cat6 Cable from Switch including PVC Pipe
Providing and Fixing I/O Box
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .