Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | ₹9.5 L | L1 | Accepted-AOC DUE TO L1 |
| 2 | L2₹10.3 L+₹75,880 (7.98%)Rejected-AOC | ₹10.3 L+₹75,880 (7.98%) | L2 | Rejected-AOC DUE TO L2 |
| 3 | L3₹11.8 L+₹2.2 L (23.6%)Rejected-AOC | ₹11.8 L+₹2.2 L (23.6%) | L3 | Rejected-AOC DUE TO L3 |
| 4 | L4₹12.2 L+₹2.7 L (28.5%)Rejected-AOC | ₹12.2 L+₹2.7 L (28.5%) | L4 | Rejected-AOC DUE TO L4 |
| 5 | L5₹12.5 L+₹3.0 L (31.6%)Rejected-AOC | ₹12.5 L+₹3.0 L (31.6%) | L5 | Rejected-AOC DUE TO L5 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
15 Mar 2021, 6:00 pmClosed
CWE YOL CANTT
HQ CWE YOL CANTT
PROVN OF HT VCB AT MAIN POWER HOUSE AT YOL
2021_MES_415237_2
CWE/Y-123/2020-21
Open Tender
Civil Works
Works
180 days
YOL Cantt
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE (KH) Yol
₹29,000
Yes
20 Apr 2021
1 Mar 2021
16 Mar 2021
1 Mar 2021
15 Mar 2021
1 Mar 2021
Amount
p) 1 No 3 way breaker control switch with positions TRIP- NEUTRAL -CLOSE q) Manual charging /operating arrangement. r) Fuses for metering and protection system. s) (i) Auto trip (ii) Motor /manual charged spring operating /closing mechanism. (iii) Fault alarm (iv) Manual tripping t) Complete control panel wiring with suitable size copper wire. u) Test Terminal Block (TTB) to test meters and relays with sealing arrangement. v) Civil work for foundation complete Note :- (i) The HT panel comprising of VCB to be manufactured by OEM and not from their feeder supplier / vender and contractor has to arrange factory inspection for routine test as per IS at OEM factory in presence of rep nominated by accepting officer before despatch from OEM's factory. (ii) Contractor shall produce manufacturers test certificate for all routine and type test of VCB's. (iii) Civil work for foundation as per manual of manufacturer.
Excavation in trenches n exc 1.5 metre wide & n exc 1.5 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n exc 1.5 metre in depth and getting out in hard/ dense soil, complete all as specified.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed.
Removal of excavated material to be distance n.exc 50 metres and depositing where directed at a level n.exc 1.5 metres high from the starting point, all as specified.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed), grade cross sectional area 240 sqmm 3 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing complete all as specified and directed. Note:- Excavation & Earth work, brick cable cover and sand cushioning shall be measured and paid separetly.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm, complete all as specified.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 32mm x 6mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
M/S MALHI CONSTRUCTIONS
M/s Raj Construction
Dn construction and co
M/s Parv Enterprises
surinder kumar jindal & bros.
B S Ranbir and Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .