| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹45.0 L+₹58,285 (1.31%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L2 | Rejected-Finance Rejected being L2 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
19 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (ARMY) CENTRAL JODHPUR
GE ARMY CENTRAL MULTAN LINES ARMY AREA JODHPUR
PROVN OF CERTAIN SANCTION WORKS UNDER GE A CENTRAL JODHPUR
2022_MES_545746_1
GE/J/A OF 2022-23 (9126/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (ARMY) CENTRAL JODHPUR
₹1 L
4 Oct 2022
17 Aug 2022
22 Sept 2022
17 Aug 2022
19 Sept 2022
31 Aug 2022
Amount
Excavation over areas not exceeding 1.5m in deep and getting out in any type of soil complete all as specified and as directed.
Removing excavated soil to a distance exceeding 250 mtr and not exceeding 500 mtr and depositing where directed at a level not exc. 1.50 m complete all as specified and as directed.
Returning, filling in, excavated material, including spreading , leveling , watering and well ramming in layer n. exc 25 cm complete all as specified and as directed.
M&L for 100mm thick (spread thickness ) soling with crushed or broken boulders or quarried stone of grading 2 ( 63 to 90 mm size ) spread and leveled interstice filled, surface formed and rolled and consolidated to required gradient and camber with 8 to 12 tone power roller, complete all as specified and directed by Engr-in-Charge.
M&L for 150 mm thick ( compacted thickness) WBM in 2 layers of 75 mm thick (each layer to be rolled and consolidated separately with coarse aggregate of grading 2 ( 63 to 40 mm size) of sand stone, flint or quartzite spread, and rolled, consolidated to required gradient and camber with power roller of 8 to 12 tonne capacity, complete all as specified and directed by Engineer-in-charge.
M&L for 200 mm thick ready mix cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less, complete all as specified and directed by Engineer-in-charge.
M&L for stone sett flooring with granite (Jallore stone ) stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush, complete all as specified and directed by Engineer-in-charge.
M&L for edge stones to flooring with stone setts of size 250 to 300mm long x 150 to 200mm wide, and 500mm deep and and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush, complete all as specified and directed by Engineer-in-charge.
Supply, fixing, testing & commissioning of advanced ESE lightening protection system including OPR lightning conductor, lightning stroke counter, surge protective device, protecting flat, test point, stainless steel clips, coupling accessories, hooks, duck foot connector, equipotential box, protecting flat, extension mast, conductor supporting stud etc for building, as per site requirement and directed by Engr In Charge
Earthing complete with galvanised earth plate electrode 600cmx600Cmx6.0mm thick, buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected with galvanised iron earth strip 32x6mm by means of bolts, nuts, check nuts and washer of galvanised iron or steel complete with 40 mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test piont etc. in and including light grade GI protection pipe 40mm bore up to 5m lenght for drawing in earth lead wire , all as shown in electrical plate No.3 of SSR Part-1 complete with necessary earth work in any type of soil, removal to a distance not exc. 50m, testing on completion complete all as specified & directed.
Supply, fixing, testing & commissioning of air termination aluminium rod 12mm dia and 300mm long, single pointed, fitted on the roof top and jointing with the aluminuim strip, including PCC work 1:2:4, complete all as specified and as directed by Engg-in-charge.
Test point terminal block made of gun metal or phosphorous bronge 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point completed all as specified.
M & L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and connected to earthing sys, complete in all respect and entire satisfication of Engr-In- Charge.
Supply and fixing of GI strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe, complete all as specified and as directed by Engg-in-charge.
M & L for GI Tubing, light grade, 20 mm bore with fitting & fixing along wall with suitable size clamps complete all as specified including PCC work 1:2:4, complete all as specified and as directed by Engg-in-charge.
Supply, Installation, testing & commissioning of 1.50 Ton split AC, 5 Star rating, with cordless remote control unit, inclding air ionizer and plasma filter for better indoor air quality with energy efficient with 2.0 KVAR stablizers copper wound voltage range from 170 V to 280 V, complete all as per specified & directed by Engg.-in-charge. Make: O'General/ Hitachi /Daikin as approved by GE.
Supply, Installation, testing & commissioning of sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but sheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including PVC casing & caping surface mounting, etc fixed in wall or ceiling etc., complete all as specified and as directed by Engr-in-Charge. NOTE: Two runs of 4.00 Sqmm cable with one run of 4.00 Sqmm earth wire and PVC casing & caping shall be measured & paid for as one length.
M&L writing letters in black colour paint following details in letters 40 mm width, complete all as specifed & directed by Engg.-in-charge. (a) Manufacturer Sl. No.________________ (b) CA No.______________________________ © Actual date of completion:___________________ (d) Intial Cost____________________________ (e) PRB Page No.___________________________ (f) Location:- __________________________________ (g) MES Sl. No._____________________________
M&L for metal clad box complete with MCB single pole 230 volts rating from 20 amps, with rupturing capacity 10 KA, 'C' curve type, with over load and short circuit protection, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
Supply, installation, testing and commissioning in existing location and position refrigerator, digital panel, electric driven, single phase having approx storae and nominal cooling capacity 310 ltrs, frost free inverter, AG clean technology, using eco friendly gas , minimum BEE 5 star rated and above complete with all acessories as per manufacturer. Make : -Bluestar/ Bosch/ Samsung
Supply, installation and testing in existing location and position, metal top deep freezer, chest freezer, double door, size 1180mm x 665mm x 830mm, CFC free insulation, sunken handle, electric driven, single phase, having approx storage and nominal cooling capacity 320 ltrs, BEE Star Rating - 3 Star and above rated. Make :- Bluestar/ Bosch/ Samsung.
Supply, installation and testing in existing location and position, metal top deep freezer, chest freezer, double door, CFC free insulation, sunken handle, electric driven, single phase, having approx storage and nominal cooling capacity 405/425 ltrs. BEE Star Rating - 3 Star and above rated, complete all as specified and as directed. Make :- Bluestar/ Bosch/ Samsung.
Supply and fixing ceiling fans with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) connecting up with and including three core flexible PVC insulated multi stranded copper condutor of size 1.0 sqmm from ceiling rose/ conector to fan (earth wire to connected to fan hook), ISI marked, complete all as per directed and specifed Make :- Havells/Orient/Usha.
Supply, installation, testing and commissioning of window type air conditioner electric driven (single phase), cooling capacity 4500 K Cal per hour ( 1.5 Ton) complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum BEE 5 star rating or above energy efficient complete with 3.0 KVA stabilizer copper wound with voltage range from 170V to 280 Volt complete all as specified and as directed. Make: Mitsubishi/ O'General/Daikin
M&L for point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, fan regulators complete for the following, complete all as specified and as directed :- (a) One light/fan/bell point controlled by one, one way switch.
S&F modular switch 1 way 6 Amp, 1 module, single pole complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body, complete all as specified and as directed by Engineer-in-Charge. Make : Anchor/ Legrand/ Havells
S&F exhaust fan, heavy duty steel body, AC single phase 300 mm sweep complete with louvers including cutting / making holes in wall fixing/grouting of frame & connecting with & including 3 core PVC insulated copper conductor flexible cable of size 23/0.0076 (or eq. Size in mm) from ceiling rose to fan, complete all as specified and as directed by Engg.-in-charge. Make : Havells/ Bajaj/ USHA
NOTE:- 10 Nos sanction job's quantities are clubbed in this BOQ, which is detailed in the Annexure-I on Sl. Page No. 23 of Tender Document. Therefore, the work and its measurement should be completed keeping in view the Annexure-I.
MOHIT ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .