Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
10 May 2022, 2:00 pmClosed
EXECUTIVE EINGINEER MECHANICAL DIVISION KARGIL
Office of Executive Engineer Mech Div Kargil
Supply, Installation, Testing and Commissioning of HSD fired Boiler based Central Heating System along with allied equipments to office of Ladakh Academy of Arts Culture and Language Centre Kargil
2022_PWD_6296_1
MDK/e-NIT/01 of 2022-23
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
60 days
Ladakh Academy of Arts Culture and Language
Please refer Tender documents.
12 documents required · 12 mandatory
₹1,000
EXECUTIVE ENGINEER MECHANICAL DIVISION KARGIL
₹50,000
Office of Executive Engineer Mech Div Kargil
3 Jun 2022
27 Apr 2022
11 May 2022
27 Apr 2022
10 May 2022
27 Apr 2022
30 Apr 2022
Amount
Supply Installation, testing and Commissioning of:
Hot Water Boiler: HSD Fired, Horizontal Fire Tube , Hot Water Generator fitted with combustion equipments, all boiler mountings- control panel, control valves, accessories and mono block pump set, including chimney of recommended dia, externally mounted at 8mtr above ground level. or as recommended by OEM along with PCC, foundation block.
Capacity each 1 Lac- Kcal/ Hr (1+1 stand by)
Hot water Circulation Pumps: Hot Water Circulation Mono-block Pump complete with electric motor of Single-Phase along-with common base frame duly grouted in cement concrete foundation alongwith NRVs as required.. Suction 80 mm Delivery 65 mm
Discharge: 6 LPS at 25 m Head Rating= 3HP (aprox)
Oil Transfer Pumps: Gear Oil Transfer Pump with electric motor single phase rating along-with common base frame duly grouted in cement concrete foundation
Capacity 2 LPS(min) @ 12 mtr Head
Soft water / Glycol Pumps: Soft Water Pump complete with electric motor of 1-ɸ, 230 V, 50 Hz, 1 HP rating along with common base frame duly grouted in cement concrete foundation.
Capacity 2 LPS (min) at 12 m Head
Day Oil Tank
SITC of Day oil tank 500 ltr capacity HDPE triple layer insulated with 25mm thick nitrile foam with 26 Gauge aluminum cladding and mounted on a suitable iron stand
Expansion Tank
SITC of Expansion tank 200 ltr capacity HDPE triple layer insulated with 25mm thick nitrile foam with 26 Gauge aluminium cladding and mounted on a suitable iron stand.
Soft Water Tank/ Glycol Water Tank
Soft water tank of HDPE (tripple layer) with necessary connections Capacity 500 Ltrs.
Hot Water Radiators: Steel panel heating radiators conforming to EN442 with working pressure ranging from 10-13 bar having working temperature at 110°C ,complete with Top grilles and side covers as standard along-with inlet valve, outlet valve, air purge valve and threaded plug as per OEM. Inlet Water Temp: 75oC Outlet Water Temp: 65oC Room Temp: 22oC
2000 Kcal/Hr (Double Panel Double Convector)
3000 Kcal/Hr (Double Panel Double Convector)
4000 Kcal/Hr (Tripple Panel Tripple Convector)
Piping: Heavy Duty MS class C pipe (external building) insulated with 25mm nitrile foam with26SWG aluminium cladding for external pipes and with heat proof enamel paint for interior pipes along with all fittings like bends, TEE supports etc.
65 mm DIA (50 mm thick insulation)
50 mm DIA (50 mm thick insulation)
40 mm DIA (25 mm thick insulation)
32 mm DIA (25 mm thick insulation)
20 mm DIA (25 mm thick insulation)
Heavy Duty PPR pipe (internal building), PN10/SDR-11, insulated with 25mm nitrile foam with26SWG aluminum cladding for external pipes and with heat proof enamel paint for interior pipes along with all fittings like bends, TEE supports etc.
40 mm DIA (25 mm thick insulation)
32 mm DIA (25 mm thick insulation)
20 mm DIA (25 mm thick insulation)
Control Valves: Butterfly valves (CI/GM) 65mm = 06 Nos. Ball valves (PPR) 50 mm = 2 Nos. 40 mm= 3 Nos. 32mm = 2 Nos. 25m = 2 Nos. 20 mm = 26 Nos. Y-strainer 65 mm DIA (C.I. Flanged) = 02 Nos. Non-Return Valves 65mm DIA (C.I. Flanged) = 02 Nos.
Electrical :
Main Panel: Main Control Panel having separate cubicals for each equipment viz. isolation for Hot Water Generator 2 No's (3hp each), DOL Starter for Hot Water Circulation Pumps 2No's , Soft Water Pumps 2 No's (1 hp each), DOL starter Softener pump 1 No (1 hp) and for HSD Transfer Pump 2 No's (1 hp) and three empty), and On-Load Change Over Switch (100 A), MCCB (100A). The control panel shall be provided with the copper bus bars dully insulated of required ratings and 3 in 1 digital Voltmeter / Ammeter / Frequency meter, indicators etc .
Cable Try: Perforated cable tray of 2 mm thickness and supported from ceiling the wall duly painted as per site condition
150 mm wide
Electrical cable: Providing and fixing PVC insulated un-armoured copper conductor cables from main panel board to various equipments to be laid over cable trays with appropriate clamps and fixing arrangements.
3 Core - 6 sq.mm
3 Core - 2.5 sq.mm
2 Core - 1.5 sq.mm
3.5 core 16 Sq. mm armored service cable
Servo Voltage Stabilizer: 3-phase, Oil cooled Servo Stabilizer micro processor controlled with high and low voltage cut off, single phase preventer, short circuit and over load protection having digital display.220 – 460 volts Phase to phase with panel as per specifications duly filled with recommended transformer oil upto full capacity
Capacity: 15 kVA with input of 220-460 Volts Phase to phase and output of 415 volts ±1% phase to phase
Earthing
Earthing Pit: Earthing for various equipments inside boiler house using copper plate electrode of size 500 x 500x 3 mm placed in 1000 x 1000x 1800 mm pit filled with charcoal & salt by copper strip of size 20 x 3 mm alongwith perforated G.I pipe.
Earthing Strip: Copper strip of size 15x3 mm from earthing electrode to the Electric Panel, Stabilizer, boiler and pumps using proper fasteners concealed under floor.
Coolant
Providing and filling of Nontoxic antifreeze (the right antifreeze product intended for use in heating boiler) of propylene glycol solution and water mixture. The ratio of antifreeze solution to the water shall be the optimum to achieve desired freeze protection of –400C.
THERMOTECH ENTERPRISES
NATIONAL ENGINEERING
ECO HVAC SOLUTIONS
M/S GRK ENGINEERING
M/S MOHD MOHMAD KHAN
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .