Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | ₹3.5 Cr Quoted ₹3.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.9 Cr+₹23.1 L (6.31%)Rejected-Finance | ₹3.9 Cr+₹23.1 L (6.31%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹3.9 Cr+₹23.9 L (6.53%)Rejected-Finance | ₹3.9 Cr+₹23.9 L (6.53%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹4.2 Cr+₹57.5 L (15.7%)Rejected-Finance RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | ₹4.2 Cr+₹57.5 L (15.7%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹4.3 Cr+₹60.8 L (16.6%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | ₹4.3 Cr+₹60.8 L (16.6%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹4.7 Cr
EMD Value
₹5.4 L
Closing Date
9 Mar 2023, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune PIN- 411001
ADDN/ALTN AND SPECIAL REPAIRS TO OFFRs, JCOs AND ORs MD ACCN AT ASHOK NAGAR, GARDEN CITY AND SARVATRA NAGAR UNDER GE DEHU ROAD
2022_MES_571673_1
CA NO CEPZ/MUM/T-19 OF 2022-23
Open Tender
Civil Works
Item Rate
730 days
Dehu Road
Class A
Category a(i)
Also refer NIT
8 documents required · 8 mandatory
₹2,000
GE Dehu Road
₹5.4 L
Yes
30 Mar 2023
28 Dec 2022
11 Mar 2023
28 Dec 2022
9 Mar 2023
23 Feb 2023
29 Dec 2022 - 10 Jan 2023
Amount
Dismantling of single layer Mangalore pattern or similar tiles in roofing laid dry or set in cement mortar all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.
Dismantling timber scantling 40 Sq cm or over in section, unframed work as in rails, post, rafters, purlins etc, in any position all as specified and directed..
Dismantling battens for tiles, shingles etc of any size including tilting fillets spaced exc. 15 cm all as specified and directed.
Dismantling timber scantling, unframed in post, rafters, purlins etc under 40 sq.cm in section.
Dismantling wrought or mild steel work of any description not otherwise provided for.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets.
Demolition of brick of any type built in cement mortar etc complete all as directed.
Dismantling floor hearth or wall tiling in cement mortar bedding (but not backing) removing serviceable tile & rubbish off the premises.
Dismantling stone slab/tiles of any description or thickness, laid, bedded & pointed in cement mortar in floors, hard standing, Apron etc
Taking down plastering on lathing (other than wire netting), without removing lathing, in lime or cement mortar or brick/ block/stone walling including raking out joints, hacking for key, scrubbing down with water etc complete.
Taking down chowkhats or frames (wooden /steel) with shutters (without taking off shutters from the frame) not exceeding 1.5 Sq.m each complete all as specified and directed including making good disturbed wall surfaces/jambs with cement plaster in 1:4 of thickness as required at site or disturbed masonry, if any, in PCC 1:3:6 type C-1 using 20 mm graded stone aggregates finished even & smooth using extra cement all as specified and directed.
Taking down chowkhats or frames (wooden/steel) with shutters (without taking off shutters from the frame) exceeding 1.5 Sq.m but not exceeding 4 Sq.m each complete all as specified and directed including making good disturbed wall surfaces/jambs with cement plaster in 1:4 of thickness as required at site or disturbed masonry, if any, in PCC 1:3:6 type C-1 using 20 mm graded stone aggregates finished even & smooth using extra cement all as specified and directed.
Taking down shutters of any description exc 1 Sq.m and not exc 2 Sq.m each.
Taking down steel window / ventilator of any size.
Dismantling of boarding of any description, fixed in any position with nails.
Dismantling of PVC water tanks of capacity upto 500 litre & removing to store complete.
Disconnecting existing tank 500 litre capacity, setting aside (or lowering if required) for repair, cleaning etc and hoisting if required, reconnecting & refixing in position (cleaning, repairing etc measured separately).
Dismantling of PVC water tanks of capacity exc 500 litre & n.exc 1000 litre and removing to store complete.
Taking up or down carefully steel tubing and connections including cleaning for refixing of size 15mm bore.
Taking up or down carefully steel tubing and connections including cleaning for refixing of size 20mm bore.
Demolition and breaking up AC, RCC, SWG drain pipes 100mm bore set in cement mortar.
Taking down rain water pipe and eaves gutter (any size & pattern), including all fittings, heads, shoes, bends, sawn-necks, etc including cleaning or refixing or removal to store (Measured overall as fixed along the centre line over fittings & accessories).
Demolition of cement concrete in ground floors and paving not exc 15cm thick (below or above ground level) un-reinforced.
Demolition of cement concrete (unreinforced) & in any position not otherwise specifically provided for.
S&F for rolled mild steel sections conforming to grade E-250 (Fe-410W, quality A) as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee angle channel or flat sections) or as in main and cross beams, hip and jack rafters, purlins, where connected to common rafters and running rails and guides for sliding doors, fixed with angle clips or other connecting plates. including distance pieces, nuts & bolts, etc. complete as specified and directed.
S&F MS angle iron in hand rail, half round or other steel section or core for wooden hand rail straight portion, wind ties for roof including securing bolts,, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, bolting etc and similar works confirming to Fe-290 Gde E-165.
Supply and fixing Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified and directed.
Supply and fixing Prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering, cladding to wall, ridge or Valley gutters fixed with self tapping screws as specified and directed.
Material and labour Aluminium powder coated snap grid false ceiling using standard aluminium sections of size 38mm x 25mm x 1.5mm as in wall angle, 25mm x 25mm x 1.5mm as in Main/ Cross Tees and grid of size 605 x 605mm suspended with 6mm dia. GI wire at intervals n.exc. 600mm centre to centre and fixed to roof truss with suitable size MS hooks and fastening bolts etc. including 9mm thick gypsum tiles for insulation & acoustic purposes ceiling boards of size 600mm x 600mm fixed with staples/clips to aluminium snap grid all as specified and as directed.
Material and labour Brickwork using old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified & directed.
M&L full body Vitrified coloured Ceramic tiles of light colour shade of 10mm thick of size 600mm x 600mm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 20 mm thick screed bed or bedding layer of cement mortar 1:6, complete all as specified and directed.
M&L full body Vitrified coloured Ceramic tiles of light/dark colour shade 10 mm thick of size 600mm x 600mm as in vertical surfaces/skirting etc. to match the vitrified ceramic coloured light shade floor tiles, set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 10 mm thick backing/rendering coat in cement mortar 1:4, complete all as specified and directed.
M&L Non skid ceramic coloured tiles of size 300mm x 300mm and 7 mm thick in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
M&L Matt finish joint free ceramic coloured tiles of size 600mm x 600mm and 9 to 10mm thick in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, over and including 15mm thick screed bed in cement mortar (1:6), complete all as specified and directed.
M&L Matt finish joint free ceramic coloured tiles as in skirting using Matt finish ceramic tiles of size 600mm x 600mm and 9 to 10mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match complete over & including 10mm thick backing coat of cement mortar 1:4 including triangular filleting in cement mortar 1:4 on top of skirting all as specified.
M&L Glazed ceramic coloured tiles of size 300x450x7mm thick of approved colour as in dado etc, set and jointed in neat cement slurry and pointed in coloured cement to match complete over & including 10mm thick backing coat in cement mrotar 1:4 including triangular filleting in cement mortar 1:4 on top of dado all as specified and directed.
M & L for Machine cut Cuddappa stone slab 20-25mm thick as in kitchen platform laid over & including 20mm thick cement screed base in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L 18 to 20mm thick green marble (Udaipur green or Baroda green) work (table rubbed & polished ) in window door cills/jambs ,steps, pillars, cooking platform like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed with granite over & including 15 mm thick screed bed in CM 1:6 complete all as directed by Engr-in-charge.
M&L 20mm thick granite(of any type) work (table rubbed & polished ) in window door cills/jambs ,steps, pillars, cooking platform like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed with granite over & including 15 mm thick screed bed in CM 1:6 complete all as directed by Engr-in-charge.
M&L Rendering 20mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing in CM 1:6 using WPC @ 3% by weight of cement finished even & smooth without using extra cement
M&L Rendering 15mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing in CM 1:4 using WPC @ 3% by weight of cement finished even & smooth without using extra cement
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even & fair.
M&L for rendering 5mm thick in cement mortar in 1:3 on ceiling finishing the surface even & smooth without using extra cement.
Preparation of new plastered Internal wall surfaces complete all as specified and M&L for the following :- (a) Applying not less than 1.5mm thick wall care putty in two coats (Total thickness in two coats shall not be less than 1.5mm) on wall surface and smoothening the surface using Mechanised sanding etc preparatory to paint as directed complete all as specified. (b) two coats of acrylic emulsion distemper over a coat of acrylic primer by using Airless spray over prepared surface as (a) above.
M&L Preparation of new plastered surfaces of walls & applied one coat of primer/ primer cum sealer having alkali resistance property diluted with water and mixed with bio block in ratio 5:4:1 followed by application applying two coats of weather proof exterior acrylic emulsion paint complete, which shall give 5 years warrenty. (Make : As per Appendix 'C').
M&L for preparing old treated plastered surfaces of wall by filling cracks by crack filler, removing nails/loose paint etc & making good surface by applying white wall care putty, smoothen surface by sand paper and applying two coats of acrylic emulsion distemper all as directed.
Preparation of new plastered surfaces of wall and applying three coats of white wash on ceiling all as specified
Complete removal of existing treatment on Old Internal wall surfaces of any description , preparation of surface by Mechanised sander having suction vacuum Bag using Smart periodical methodology , complete all as specified and M&L for the following : :- (a) Applying not less than 1.5mm thick wall care putty in two coats (Total thickness in two coats shall not be less than 1.5mm) on wall surface and smoothening the surface with sand papers / Mechanised sanding etc preparatory to paint as directed complete all as specified (b) applying two coat of acrylic emulsion distemper of approved tint over a coat of acrylic primer on prepared surface as (a) above by using Airless spray / Roller over complete all as specified complete all as specified Note : Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-charge in case of using of Mechanical equipment are not possible
Complete removal of existing treatment and applying two coats of cement base paint white or tinted, on walls, all as specified and directed.
Preparation of old decorated surfaces by brooming down and scrapping wherever necessary and applying one coat of white wash on ceiling all as specified and directed.
Preparation of new wooden surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
Preparation of old painted wooden surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint all as directed.
Preparing new surfaces of steel exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.
Preparation of old painted steel surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint all as directed.
Resecuring or easing & adjusting, without taking down shutter of any description exc 1 Sq.m and n exc 2Sqm each complete all as specified and as directed.
S&F pressed steel frames for doors with one or more rebates including necessary hold fasts, hinges, lock strike plate etc complete as specified size of frame 125 x 60mm filled with PCC 1:3:6 type C-0 all as specified.
S & F pressed steel frames for doors with one or more rebates including necessary hold fasts, hinges, lock strike plate etc complete as specified size of frame 105 x 60mm filled with PCC 1:3:6 type C-0 all as specified.
S & F pressed steel frames for doors with one or more rebates including necessary hold fasts, hinges, lock strike plate etc complete as specified size of frame 165 x 60mm filled with PCC 1:3:6 type C-0 all as specified.
S & F IInd class hard wood 35mm thick factory made, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneer particle board with commercial veneering on both faces. The size of the rail as per IS 1003 (Part-I) Kiln seasoned and chemically pressure treated.
S & F IInd class hard wood 35mm thick factory made, glazed and skeleton shutter open rebated and prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc; The size of the rail and stile as per IS 1003 (Part-I), Kiln seasoned and chemically pressure treated.
S & F 30mm thick flush shutters, factory made, solid core construction, with block board core and plywood face panels commercial type on both faces including 6mm thick Ist class HW (Teakwood) beading all around on edges.
S&F medium density particle board, 18/19mm thick, flat pressed three layer or multilayer and graded (grade I or grade II) bonded with BWP adhesive , fixed with screws to timber frame work/steel frame work for kitchen cabinet etc complete all as specified
S&F medium density particle board, 25mm thick, flat pressed three layer or multilayer and graded (grade I or grade II) bonded with BWP adhesive , fixed with screws to timber frame work/steel frame work for kitchen cabinet etc complete all as specified
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.18 mm & fixed with stainless steel wire staples all as specified.
S&F sheet glass ordinary quality, 3 mm thick and glazing with oil putty in square n.exc. 0.50 Sq.m in each pane.
S&F sheet glass ordinary quality, 4.8 mm thick and glazing with oil putty in square n.exc. 0.50 Sq.m in each pane.
S&F aluminium anodised barrel tower bolts of extruded section 200 mm long.
S&F aluminium anodised barrel tower bolts of extruded section 150 mm long.
S&F aluminium anodised barrel tower bolts of extruded section 100 mm long.
S&F aluminium handles, anodised, cast type, of size 100 mm.
S&F aluminium handles, anodised, cast type, of size 150 mm.
S & F butt hinges 75mm size stainless steel medium weight all as specified.
S&F aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section etc length of bolt 250 mm.
S&F aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section etc length of bolt 300 mm.
S & F in repair Sink made out of stainless steel 1mm thick for kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe for over all size 495mm x 420mm, bowl size 410mm x 330mm x 160mm etc complete all as specified and directed.
S&F in repairs stainless steel plate racks of size 31" x 36" x 10" (or nearest size) conforming to cat part No. SSKPR-315 of Silver Shine or of equivalent model in other makes specified in Appendix 'C' complete all as specified & directed.
S&F in repairs stainless steel plate racks of size 36" x 36" x 10" (or nearest size) conforming to cat part No. SSKPR-317 of Silver Shine or of equivalent model in other makes specified in Appendix 'C' complete all as specified & directed.
S & F 300mm, Mild Steel ordinary rat tail rod pattern spring including roller and roller plate complete.
S&F in repairs chromium plated two way bib cock with wall flange 15mm dia conforming to cat No. DLX-512ANKN of Jaquar or of equivalent model in other makes specified in appendix 'C' complete all as specified & directed.
S&F in repairs chromium plated single towel rail 600mm long including built in side brackets conforming to cat No. AEC-1111N of Jaquar or of equivalent model in other makes specified in appendix 'C' complete all as specified & directed.
S&F in repairs chromium plated soap dish , conforming to cat No. AEC-1131N of Jaquar or of equivalent model in other makes specified in appendix 'C' complete all as specified & directed.
S&F in repairs chromium plated towel ring round, conforming to cat No. AEC-1121N of Jaquar or of equivalent model in other makes specified in appendix 'C' complete all as specified & directed.
S&F in repairs chromium plated wall mixer 3-in-1 system with provision for both hand shower and overhead shower complete with wall flange with 115mm long bend pipe, connecting legs ,conforming to cat No. APR-101281 of Jaquar or of equivalent model in other makes specified in appendix 'C' complete all as specified & directed.
S&F in repairs chromium plated towel rack, 600mm long with lower hangers, conforming to cat No. AEC-1181N of Jaquar or of equivalent model in other makes specified in appendix 'C' complete all as specified & directed.
S&F in repairs 25 mm dia Aluminium powder coated decorative type curtain rods.
S&F Aluminium powder coated curtain rod side brackets of approved quality & design.
S & F in repair fancy type Stainless Steel curtain rod 25mm dia complete all as specified & directed.
S & F stainless steel brackets suitable for 25mm dia curtain rod complete all as specified and directed.
S&F External teak wood liping 6 mm thick for 18/19 mm thick particles board, block board or veneered particle board fixed with nails. (for Kitchen cabinets)
S&F in repairs pre-laminated particle board 25mm thick exterior grade prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including 6mm thick teak wood liping Patti complete.
Supply and fix for brass locks, cupboard, grade 1, 75mm size, 4 levers with duplicate keys with brass key hole complete all as specified and as directed.
S&F, 100mm size Hasp and staple, safety type aluminium anodized stove enamelled black with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed (for Kitchen cabinets)
S & F of 100 mm size stainless steel hasp and staple safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F continuous (piano) hinges, mild steel, bright finish or electro galvanised 30mm width of flaps (for Kitchen cabinets)
S&F 40 mm dia, mild steel bright finished cup board knobs fixed with nut, screw and washer complete all as specified and directed. (For Kitchen cabinets)
S&F, Ball catches with 8 mm dia steel ball, and brass body and striking plate including letting in complete all as specified and as directed. (for Kitchen cabinets)
Supply and fixing three track sliding window including frame with two shutters with 4mm thick tinted glass and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18 mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc; fabricated using following aluminium anodised sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engineer-in-Charge. (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352. (Note:- Cost of Tinted glass & wire cloth shall be included in the quoted rate of the item).
S & F fixed louvered aluminium ventilators including frame with adjustable louvers fixed with and including 4mm thick frosted glass louvers and shall be fly proof with stainless steel wire gauge of 0.36mm dia and 1.18mm aperture fixed to frame with aluminium beading and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading etc all as directed :- (a) SP 20048 (b) Glazing clips 19352 (Note:- Cost of glass louvers & wire cloth shall be included in the quoted rate of the item).
M&L for MS framed work conforming to grade E-165 (Fe-290) or Fe-310-O of MS angle or other sections, such as grills, gratings with ends of bar shouldered and / or riveted or forged into spikes; framed guard bars; railings and like completed all as directed by Engineer-in-charge.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube, all as mentioned in Item No. 8095 of SSR Part-II.
S&F factory made solid panel PVC door shutter 30mm thick (stiles) consisting of frame made out of M.S tubes for top & bottom rails; M.S frame shall be covered with heat moulded plain colour PVC ‘C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification and drawing.
S & F rolled mild steel section conforming to grade E-165 (Fe-290) framed work as in door or gates of angle or other section with gusset plates rails, braces, etc complete drilled for fixing of steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging, fastening, etc complete all as directed by Engr-in-Charge.
Cutting holes in stone walls built in cement mortar for inserting hold fasts, depth of embedded portion exc. half brick but n.exc one brick and making good in CM (1:3) or PCC (1:2:4) type B-1.
S&F 500 litres capacity Rotational moulded polyethylene in white coloured three layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as per specified and directed.
S&F 1000 litres capacity Rotational moulded polyethylene in white coloured three layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as per specified and directed.
S&F in repairs 20mm nominal size brass float valve, high pressure, with polythene float and fly nut, screwed for iron pipe and fixed complete all as specified
S&F GI tubing 15 mm bore medium grade galvanised with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified.
S&F GI tubing 20 mm bore medium grade galvanised with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified.
Refixing only 15 mm dia old steel tubing and connections in new or old position (wall, ceiling and floors etc)
Refixing 20 mm dia old steel tubing and connections in new or old position (wall, ceiling and floors etc)
S & F in repairs ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore and fixed (minimum weight 210 gms ) complete all as specified and as directed.
S&F 15mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipes all as specified fixed in repairs.
S&F 15mm bore bib taps, brass chromium plated, cast copper alloy fancy type handle, screwed down, screwed for iron pipes all as specified fixed in repairs.
S & F in repair stop valve 15mm bore brass chromium plated fancy type, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge.
S&F brass chromium plated shower rose with or without swivel joints, any size including fixing to a steel pipe or union of size 125mm size.
S&F Grating doom 140 mm dia with waste hole of PTMT. (Minimum weight 50 gms)
S&F in repairs Grating doom 100 mm dia with waste hole of PTMT. (Minimum weight 25 gms)
S&F in repair wash hand basin of size 515 x 410x195 mm vitreous China white flat back conforming to cat part No. S2040121 of CERA or of equivalent models in makes specified in Appx 'C', including brackets, waste coupling & PVC waste pipe of 32 mm dia etc. complete all as specified and directed.
S&F in repairs, pillar taps brass chromium plated 15mm dia cast copper alloy with capstan heads, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe.
S & F in repair double Angular stop cock with wall flange cast copper alloy, chromium plated fancy type with long shank and cup screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed to 15mm bore GI pipe. Complete all as specified and directed.
S & F PVC connections 15mm size with PTMT nuts of length 450mm.
S&F in repairs 12 " size, corner glass, 8mm thick ,fancy type fixing to wall with chromium plated screw all as specified and directed.
S & F in repairs 32 mm dia PVC waste pipe for low level flushing cistern.
S & F in repairs glass shelf 12" long x 6" wide and 8mm thick of glass, fixed with chromium plated screw to walls.
S&F for mirror cabinet PTMT (bathroom cabinet) of 55.5 x 45 x 12.4 cm with magnetic locking arrangements fixed with and including chromium plated brass screws and PVC rawl plugs complete all as specified & directed. Makes: Prayag / Neelkamal / Cello
S&F looking mirror of size 600 x 450mm approved quality and make , mounted on 6 mm thick plywood commercial as backing and aluminium powder coated frame all around on edges complete as directed.
Supply and fix in repair for hand shower, chromium plated (health faucet) with 8mm dia, 1.0 metres long flexible tube and wall hook as approved by GE with chromium plated angular cock 15mm bore with stud complete all as specified and as directed.
S&F PVC (SWR) floor/Nahani trap, plain with grating including jointing with solvent cement, 75mm diameter of outlet, all as specified.
S & F PVC low level cistern of 10 litres capacity cat part No. S1010110 of CERA or of equivalent model in makes as specified in Appx 'C' inclusive of brackets and PVC bend long type and connecting to flush pipe of any size and pattern with inlet ball valve float and handle complete of approved make
S&F PVC (SWR) pipes of size 110mm bore, single socketed in any length with rubber ring joints laid in trenches or fixed to wall complete all as specified & directed
S&F PVC (SWR) pipes of size 75mm bore, single socketed in any length with rubber ring joints laid in trenches or fixed to wall complete all as specified & directed
S&F PVC (SWR) bends any radius 110 mm bore provided with access door.
S&F PVC (SWR) bends any radius 75 mm bore provided with access door.
S&F rolled MS sections conforming to E-165 (Fe-290) as in bands, straps, supports, hooks, heavy, for large gates, clamps, hold fast, hooks for hanging fans, etc.
S&F PVC SWR branch piece , (Double 'Y') equal or unequal of 75 mm bore provided with access door.
S&F PVC (SWR) vent cowl 110 mm bore
S&F PVC (SWR) vent cowl of 75mm bore
M&L for SGSW gully trap 150x150mm, square or round mouthed setting and jointing to drains with CM 1:1.
S&F in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.18 mm & fixed with stainless steel wire staples all as specified.
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified
Material and labour for water proofing treatment to sunken slab, walls, etc, and shall be carried out as specified below and as directed.
(a) Clean the sunken portion of toilet / Baths/ WCs/ Kitchen thoroughly to remove laitance, dirt, dust etc.
(b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar (“ Dr fixit” Pidicrete URP” or equivalent).
(c) Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bath seal Tape” and the gaps to be grouted with non-shrink cementitous grout “Dr Fixit Bath seal Grout” or equivalent. Nahani traps etc to be fitted securely and the gaps around it to be grouted in the same manner.
(d) Apply one coat of a Bitumen-modified polymer coating “Dr Fixit Bath seal Plus” or equivalent on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.
(e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproofing waterproof coating “Dr Fixit Pidifin 2 K” or equivalent can be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely.
(f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed 1:3:6 type B0 mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40 mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2.
(g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready to make tile grouts of approved makes such as Dr Fixit, FOSROC SIKA, MC BUCHEMIE, ROFF, etc.
M & L for plastering 15mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in CM 1:4 finished even and fair complete
M & L 50 mm thick Cement concrete type C-1, 1:3:6 (20 mm graded stone aggregates) as in plinth protection finished even and fair .
M & L for cement concrete Type C2 1:3:6 (using 40mm graded aggregates) as in plinth protection 75 mm thick finished top surface even and smooth without using extra cement complete all as specified and as directed.
M & L for 100 mm thick Cement concrete type D-2 1:4:8 (40 mm graded aggregate) as in hard standing complete all as specified and as directed.
M&L for 40mm dia GI pipe heavy class fixed out from sunken portion for spout all specified and directed
S & F in repairs vitreous China squatting pan of Orissa pattern cat part No. CALINA S3010102 of CERA or of equivalent model in makes as specified in Appx 'C' with P or S trap of size 580 mm X 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe including lime concrete bedding and connection to antisyphonage pipe etc including making good to floor.
S & F in repairs Wash down water closet (Pedestal pattern) cat part No. S1053101 of CERA or of equivalent model in makes as specified in Appx 'C' with P or S trap , white in colour complete including PVC white seat cover Cat part No B1510123 of CERA or of equivalent model in makes as specified in Appx 'C' (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe and connection to antisyphonage pipe etc complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete
Complete removal of existing treatment and applying three coats of white wash on ceiling all as specified and directed
Taking down carefully existing bituminous felt including plastered lime or cement concrete of any thickness and cleaning of the surface of roof trenches including flushing and junction parapets kerb walls PCC fillets benching etc with wire brushes and removing of the rubbish to a distance not exc 500mtrs and depositing where directed at a level not exc 1.5 meters above the starting point complete all as specified.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight)
M&L Water proofing treatment to RCC roof slab and shall be carried out as specified below all as specified and directed :-
(a) M&L laying 25mm thick PCC type B-0,(1:2:4) using 12.5mm graded stone aggregate finished even & smooth without using extra cement to cover negative slope into prop with WPC as per manufacturers instructions. (Water proofing compound shall be measured & paid separately).
(b) The roof surface shall be thoroughly wire brushed, cleaned to eliminate all sharp projection washed dried up and cleaned of all foreign matter and dust to receive primer.
(c) M&L Applying bituminous primer on cleaned surface @ 0.40 Lit/Sq.m.
(d) M&L Providing APP polymer modified approved membrane 3mm thick, non woven, polyster, weighing not less than 3.6 Kg/Sq.m and laying on roof surface and parapets with laps, overlaps and sealing joints as specified and applied completely by torch application method, the overlap of membrane while torching shall be kept 100mm on length wise and 100 mm width wise; all as specified & directed.
(e) M&L Carrying out test by flooding water for 24 hrs for leakages & seepages and rectifying the leakages / seepages / defects, if any, to the entire satisfaction of GE.
(f) M&L Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 litre/Sq.m on the top of membrane surfaces complete all as specified & directed.
(g) The treatment shall be carried out as per manufacturers instructions and through authorised applicator of manufacturer.
(h) Notes:- The contractor shall furnish the following before and during progress of water proofing work:- (i) Quality confirmation from the manufacturer of the product alongwith quantity supplied. (ii) Manufacturer test certificate. (iii) The result, if tested in any of the independent laboratory or testing if ordered by GE, the testing charges shall however shall be borne by the contractor.
M&L for precast coloured, chequered cement concrete tiles, glossy finish of size 305 x 305 x 25 mm thick, conforming to IS-1237 (2006) set jointed and pointed in neat cement slurry in floor laid over and including 15mm thick screed bed in CM (1:6).
Excavation in trenches n.exc 1.5mtr wide and n.exc. 1.5m in depth for foundation and getting out in soft/loose soil.
M&L RCC pipes class NP-2 with socketed ends laid and jointed complete of 150mm bore.
M&L RCC pipes class NP-2 with socketed ends laid and jointed complete of 200mm bore.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate as in bed to drain pipes including forming cradles for 150mm RCC Hume pipe.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate as in bed to drain pipes including forming cradles for 200mm RCC Hume pipe.
Returning filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm
Removing the excavated surplus soils exc 1.5KM n.exc 5 KM and depositing where directed at a level n.exc 1.5 mtr above the starting point (Note : Site of disposal of soil is to located by Contractor himself. If any extra lead for disposal of soil behind 5km will be bear by the Contractor)
M & L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregates as in surface channels.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, for the following internal dia of pipe 150mm.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, for the following internal dia of pipe 200mm.
Supply and fix for 50 mm thick, 900X650mm, heavy duty, factory made precast cover RCC (1:2:4) type B1 (using 20 mm graded broken stone aggregate) including MS TMT bars 6mm dia @ 150mm C/C both way and set in CM (1:4) finished the surface even and fair complete all as specified and as directed.
Supply and fix for 50 mm thick, 600X450mm, heavy duty, factory made precast cover as in manhole covers without additional frame for fixing RCC (1:2:4) type B1 (using 20 mm graded broken stone aggregate) including MS TMT bars 6mm dia @ 150mm C/C both way and set in CM (1:4) finished the surface even and fair including demolition of existing reinforced cement concrete complete all as specified and as directed.
Supply and fix for 50 mm thick, 600X600mm, heavy duty, factory made precast cover as in manhole covers with additional frame for fixing RCC (1:2:4) type B1 (using 20 mm graded broken stone aggregate) including MS TMT bars 6mm dia @ 150mm C/C both way and set in CM (1:4) finished the surface even and fair complete all as specified and as directed.
M&L for gunniting concrete as in chajjas by applying one layer of concrete 25 mm thick comprising composition of 50 Kg of cement, 3 to 6 mm stone chips 100 Kg and sand 50 Kg mixed with spray set SL 2 to 2.5% by weight of cement and 12.5 to 16.5 litre of water, mixed with admixtures including bonding agent by spray jetting, over cleaning loose concrete from reinforcing bars, cleaning reinforcement of total rust using alkaline rust remover with paint brush and removing loose particles after 24 hours of its application with wire brush. Supply and applying two coats of epoxy base passivating, protecting and bond coats of zinc rich system (Nitco zinc primer of FOSROC or equivalent in SIKA/ DR FIXIT PIDILITE) complete all as specified and as directed.
Supply only liquid water proofing compound
Material and labour scrapping and removing old paint, lease material and algae fungus then cleaning of surface with water using pressure washer machine, then crack filling with acrylic based textured crack filler and then applied with one coat of primer/ primer cum sealer having alkali resistance property diluted with water and mixed with bio block in ratio 5:4:1 followed by application of two coats of Weather proof exterior acrylic emulsion paint of approved shade having silicon additives in paint which shall give 5 year of performance warranty (Makes as per Appendix 'C') complete all as specified & directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down carefully copper/aluminium sub main wiring complete and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed
Material & Labour for Point wiring with 1.5 sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade, ,single core, multi-stranded copper conductor, and continuous earth wire unsheathed (FRLSH) ,single core multi-stranded copper conductor cable of size 1.5 sq mm earth continuity conductor Conforming, to IS :694-2010, connected to common earth dolly, color coding of wire shall be Red wires for phases, black wire for neutral and green wire for earth ,drawn in and in and including PVC casing & capping (ISI mark) of suitable size including with all fittings and accessories including concealed MS / pressed steel sunken box not less than 1.2 mm thick painted with black bituminous paint from outside and two coat of aluminium paint inside for housing switches ,sockets ,fan regulator etc covered with 3.0 thick white plastic laminated/hylam sheet / bakelite sheet (ISI marked), and making good to the disturbed surfaces to match the existing surfaces etc complete all as specified & directed for the following:-
(a) One light point controlled by one switch
(b) One light point controlled by two 2 way switches.
(c) One bell point controlled by one bell switch.
(d) One fan/exhaust fan point controlled by one switch & regulators
(e) One socket outlet 5 pin 5 Amps flush type on independent board
(f) One socket outlet 5 pin 5 Amps flush type on same board
All as per srl item No 174 here-in-before but for one socket point 15 Amp with 2.5 sq mm PVC insulated unsheathed (FRLSH), 1100 volts grade, ,single core, multi-stranded copper conductor, and continuous earth wire unsheathed (FRLSH) ,single core multi-stranded copper conductor cable of size 2.5 sq mm earth continuity conductor Confirming, to IS :694-2010, connected to common earth dolly complete all as specified & directed by Engr-in-charge.
S&F Switch piano, flush type single pole, one way 6 Amp ,230 V AC ,50Hz ,ISI Marked all as specified and directed
S&F Switch piano, flush type single pole, one way 16 Amp ,230 V AC ,50Hz ,ISI Marked all as specified and directed
S & F Switch piano, flush type single pole, two way 6 Amp. ,230 V AC, 50Hz ,ISI Marked all as specified and directed
S&F bell push type 6 Amp. ,230 V AC , 50Hz,ISI Marked all as specified and directed
Supply & Fixing ding dong electric calling bell 240V, 50Hz, ISI Marked AC complete all as specified.
S & F socket outlet 2-in-1, 3 pin , 6 amps ,240V, 50Hz, shuttered , flush type complete all as specified.
S & F socket out let 2 in 1 , 3 pin 6 and 16 amps flush type 240V, 50Hz, complete all as specified.
S&F ceiling rose surface type 65 X 50mm, with 3 terminals ISI Marked complete all as specified.
M & L lamp holder Angular PVC /Poly carbonate , with back plate for batten fitting complete.
S&F regulator electronic step type 100 W for ceiling fans 1200 / 1400mm sweep suitable for AC 230 volts 50 Hz ISI Marked complete all as specified.
Supply & fixing in replacement LED bulb 7 watts high power low heating super flux LEDs, 100 lumen/ watt, 120-270 V AC inbuilt electronic driver, complete all as specified
Material and labour for sub main wiring with two single core 4 sq mm nominal area with 1100 Volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 4 Sq mm multi stranded copper conductor cable (FRLSH) ISI Marked for continuous earth wire drawn in and including surface rigid non-metallic PVC conduit (ISI mark) of size 19/ 20 mm dia medium grade with fitting (ISI) marked and making good of walls etc complete all as specified and as directed Note : (i) Two runs of cable and one run of earth cable & one RM of PVC conduit shall be measured as one length (ii) Cable for earth wire shall run inside the conduit (iii)Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
Material and labour for sub main wiring with two single core 2.5 sq mm nominal area with 1100 Volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 2.5Sq mm multi stranded copper conductor cable (FRLSH) ISI Marked for continuous earth wire drawn in and including surface rigid non-metallic PVC conduit (ISI mark) of size 19/ 20 mm dia medium grade with fitting (ISI) marked and making good of walls etc complete all as specified and as directed Note : Two runs of cable and one run of earth cable & one RM of PVC conduit shall be measured as one length (ii) Cable for earth wire shall run inside the conduit (iii)Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
Material and labour for sub main wiring with two single core 6.0 sq mm nominal area with 1100 Volt grade confirming to IS 694 (2010) PVC insulated unsheathed with one run of 6.0 Sq mm multi stranded copper conductor cable (FRLSH) ISI Marked for continuous earth wire drawn in and including surface rigid non-metallic PVC conduit (ISI mark) of size 19/ 20 mm dia medium grade with fitting (ISI) marked and making good of walls etc complete all as specified and as directed Note : Two runs of cable and one run of earth cable & one RM of PVC conduit shall be measured as one length (ii) Cable for earth wire shall run inside the conduit (iii)Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
Supply and Fix 20 watt LED tube light fitting 4 feet long, with extruded polycarbonate housing and robust construction LED lighting fixture with high lumen output, environmental friendly, energy efficient CRI-6500K, P.F 0.95 fixed on PVC square for mounting the fittings and electrically connecting with three core 23/0.0076. PVC insulated multi stranded copper flexible cable from ceiling rose to light fitting ((connector of lamp fitting ) and one for earthing complete all as specified and directed. Make: Wipro Cat No LL20-221-XXX-65 NE3 **6500K/ HAVELLS Model LHEXBLP7PN1W020 / HALONIX Cat NO HLB-08-20-CW-IP.
S&F decorative wall mounting fitting, in opal glass with nickel finish suitable for 6W/7 W/9W LED lamp working on AC 240 volts, 50 Hz including led bulb complete all as specified and directed. Make : Jaquar Cat Part No JNL-CHR-WL SL55004E27/ Philips Cat No 34143 / Havells Cat Part No LHFOAJE1TZ1I060.
Supply and fixing LED street light fitting 35/36 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connection three core 23/0.0076. PVC insulated multi stranded copper flexible cable from ceiling rose to light fitting complete Make: Philips Cat No BRP030 LED35 CW MR PSU GR DX / Bajaj Cat No ENXT P35L WH PO PC SD / Crompton Cat No TRP-400-35-57-SL-LM-NSR.
Material and labour street light bracket made of GI pipe light grade 40 mm dia duly bend to shape , 1.20 mtr in length including two pairs of MS flat iron strip of 40 mm X 6 mm clamp of suitable size with necessary GI nuts, bolts 75 mm long 12 mm dia-04 nos with flat washers 3 mm thick-04 nos including painting with aluminium paint over one coat of red oxide primer to the MS Clamps and bracket etc. complete and fixing on wall/ poles complete all as specified and directed.
Supply & fix in replacement Metal clad sheet metal encloser with two pin & earth plug & socket complete with single pole MCB of 20 Amps, 240 V, AC, 50 Hz (for AC) all as specified.
S & F of 8 way SPN DB made of CRCA sheet, RAL 9003, powder coated for IK-09 double door, IP-43 metal door, confirms to IS-8623-1&3, IEC 61439-1&3, 240 V, ready to use provided with 100A insulated phase bus bar, neutral bar's with shroud's, earth bar, sticking saddles, cement spill protector, colour coded interconnecting wire set, cable ties, blanking plates & circuit identification label with suitable for DP, MCB/ Isolator/RCCB/RCBO as incomer & SP MCB's as outgoing copper lugs/thimbles duly crimped for connection complete all as specified and directed. including taking down of old unserviceable DB.
S & F of 12 way SPN DB made of CRCA sheet, RAL 9003, powder coated for IK-09 double door, IP-43 metal door, confirms to IS-8623-1&3, IEC 61439-1&3, 240 V, ready to use provided with 100A insulated phase bus bar, neutral bar's with shroud's, earth bar, sticking saddles, cement spill protector, colour coded interconnecting wire set, cable ties, blanking plates & circuit identification label with suitable for DP, MCB/ Isolator/RCCB/RCBO as incomer & SP MCB's as outgoing copper lugs/thimbles duly crimped for connection complete all as specified and directed, including taking down of old unserviceable DB.
S & F MCB DB VTPN 4 way in repair, metal double door load line powder coated IP 43 Protection With provision for 4 Pole MCCB as incomer and SP/TP MCBs as outgoings complete Provided with insulated vertical phase bus-bars neutral bars with shrouds, earth bars , sticking saddles, cement spill protector, colour-coded interconnecting wire set , cable ties, blanking plates and circuit identification labels, fixed on wall duly in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed. including taking down of old unserviceable DB. Note: (i) MCCB shall be measured & paid separately
Notes for item Nos 195 to 197 :- (i) MCBs shall be measured & paid for separately under respective items. (ii) MCB DB & MCBs shall be of same make.
S& F in replacement MCB SP 6 to 32 amps, AC, 240V, 50 Hz, having 'B' curve breaking capacity 10 KA ,240 Volts with ISI marked including copper lugs/thimbles of size as per wire/cable including crimping for connection complete all as specified and directed.
S&F in replacement MCB Double Pole(DP) 25 Amps, AC, 240V, 50 Hz, having 'B' curve breaking capacity 10 KA ,240 Volts with ISI marked including copper lugs/thimbles of size as per wire/cable including crimping for connection complete all as specified and directed.
S&F in replacement MCB Double Pole(DP) 25 to 40 Amps, AC, 240V, 50 Hz, having 'B' curve breaking capacity 10 KA ,240 Volts with ISI marked including copper lugs/thimbles of size as per wire/cable including crimping for connection complete all as specified and directed.
S&F in replacement MCCB 4 pole 63 Amps, AC, 415V, 50 Hz 50 Hz, breaking capacity 16 KA with ISI marked with cable connection including copper lugs/thimbles of size as per wire/cable including crimping for connection complete all as specified and directed.
S&F in replacement MCCB 4 pole 40 Amps, AC, 415V, 50 Hz 50 Hz, breaking capacity 16 KA with ISI marked including copper lugs/thimbles of size as per wire/cable including crimping for connection complete all as specified and directed.
S&F in replacement of Meter box made out of 2.00 mm thick MS sheet ,powder coated of size1mtr x 1mtr X 0.25mtr split in two parts 0.4 X 1 mtr on top for 04 meters and 0.6X 1 mtr for fixing of MCB DB (TPN/SPN).The top portion shall be provided with glass of size 10 cm x 10 cm in front of each meter to facilitate recording of meter reading and door with locking arrangement and box to be fabricated such as the MCBs can be operated from out side including Removing and refixing of meters (4 Nos) . Note: Rate quoted also includes fixing of the DB completely on angle frame with necessary cable for internal wiring in the DB, lugs , insulators Etc and making good the disturbed surface to match with the existing.
Taking down ceiling fan of any size/sweep after disconnecting the wire from existing ceiling rose including refixing the same after rewiring work over hauling, painting with two coats synthetic enamel paints and writing MES No. all as directed by Engr-in-Charge.
Taking down exhaust fan of any size/sweep after disconnecting the wire from existing ceiling rose including refixing the same after rewiring work over hauling, painting with two coats synthetic enamel paints and writing MES No. all as directed by Engr-in-Charge.
Supply and fix Exhaust fan metal body exhaust fan 300mm sweep, 1400 RPM single phase light, one number of speed set, fixing by means of rugged bolts, nuts and washers etc on round hole cut in wall, including three core copper conductor flexible cord of 1.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of exhaust fan suitable on working AC,SP 230 v electric supply complete all as specified and directed.. Makes as listed in Appendix 'C.
M&L for dismantling existing geysers horizontal/ vertical type of capacity 25/50 litres from site and should keep at safe place to reuse again all as specified and directed by Engr in change.
Fixing only of Geyser of capacity 25/50 ltrs, Vertical/horizontal including necessary fittings for fixing on wall all as specified and directed by Engr in charge.
Material & labour earthing, complete with galvanised steel earth plate electrode 600 x 600 x 6.00 mm thick vertically in ground (earth pit not less than 2.25m deep below the ground level and top edge of the plate not less than 1.5 m below ground level ) connected with and including galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers etc . GI pipe of size 15 mm dia medium grade for protection of G.I. earth lead wire ,both to be provided to the extent of 7.5 meters ,all as shown in electrical plate No. 3 of MES SSR Part I (2009)Part -I, other end connected to electrical main switch (inside the bldg) GI protection pipe buried in ground, laid under floors, plinths or fixed on wall or concealed in wall etc. with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, including in PCC (1:3:6) type C1, earth pit chamber with M.S. angle iron frame ,re-cast reinforced 1:2:4 type B1 cover with locking arrangement, with 20 mm dia GI pipe light grade pipe & M.S. funnel with wire mesh for watering arrangement ,including necessary excavation and earthwork in any type of strata & testing on completion, complete all as specified and as directed (Note: GI earth wire &GI pipe 15 mm bore medium grade for encasing GI wire beyond 7.50 m length per earthing if so required at site shall be measured & paid separately.
M&L for fixing of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.0 mm dia galvanised iron or steel wire
Supply, laying, connecting, testing & commissioning XLPE Insulated PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25sq mm 3.5/4 core. confirmingtoIS-7098(Part-I) laid in cable trenches /Duct /Wall /surfaces /Pipe including compression gland , lugs as required at site complete all as specified and as directed.
Supply, laying, connecting, testing & commissioning XLPE Insulated PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core. confirmingtoIS-7098(Part-I) laid in cable trenches /Duct /Wall /surfaces /Pipe including compression gland , lugs as required at site complete all as specified and as directed
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point for soil
M&L for river sand cushioning (dry) in trenches for protection of UG cable (below, above and around the UG cable laid in trenches) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the cable) and consolidated (punned) up to 18 cm thickness complete all as specified and directed Note: Punned thickness of sand shall be considered for measurement purpose.
Supply and fixing bricks sub class B designation 75 old size laid breadth-wise along the length of cable laid in trenches over sand cushion laid for protection of cable all as specified and directed
S&F or laying GI tubing light grade 40 mm dia ,ISI Marked ,confirming to IS-1239 for encasing L.T. cables for mechanical protection ,laid under Plinths/Floors/ roads/ paths/ culverts or fixed on walls or concealed in wall or along the steel poles including bends/ clamps and including all fittings & accessories complete all as specified and directed.
L.K.R.TIWARI CONSTRUCTION
SLB Enterprises
Shri Sai Electricals
VIRENDRA FABRICATORS
S G Enterprises
DEEPARTH INFRASTRUCTURE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .