Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC III 246 MANIYATTU BUILDING KURUPPAMPADY P O RAYAMANGALAM ERNAKULAM KERALA 683545 INDIA | ERNAKULAM | KERALA | 683545 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹32.6 L+₹1.4 L (4.35%)Rejected-AOC | L2 | Rejected-AOC Second Lowest bidder | |
| 3 | L3₹33.5 L+₹2.2 L (6.99%)Rejected-AOC | L3 | Rejected-AOC Third Lowest bidder |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
11 Oct 2022, 5:00 pmClosed
Executive Engineer
PWD Electrical Division Thrissur
GENERAL-Budget work 2020-21- Improvements with Thoppumpady jn by providing hand rails, Drainage and footpathProviding Street Light fittings from Thoppumpady junction to TR road. -General Electrical Work
2022_PWD_511979_1
PWD/BLDG/8626/2022-2023
Open Tender
Electrical Works
Item Rate
120 days
Ernakulam
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,760
₹50,000
28 Mar 2023
30 Sept 2022
14 Oct 2022
30 Sept 2022
11 Oct 2022
30 Sept 2022
Amount
STREET LIGHT
OD156085/2021-2022:Supply installation testing and commissioning of Pole made of K lite fittings of Circular 89 serie of KP-44 mounting having pole size of dia. 88.9 of P7 pole type with ID KP – 4269/equivalent including foundation bolt fixed in existing RCC foundation etc. complete 3.66 Meter height.
OD156087/2021-2022:Supply Conveyance, installation, testing and commissioning of 50 W LED K Lite fitting ( Ring fort Arc 5194)/equivalent of spun aluminium body of non- yellowing UV stablised, clear acrylic V diffuser/ clear acrylic convex diffuser, clear plycarbonate v diffuser, with asymmetric distribution suitable for mounting to internally threaded pipe of designation M30. Cable entries for through – wiring of mains supply cable, earth connection, safety class I protection class IP 65 prewired with LED driver and suitable for operation on 240V, 50Hz single phase a.c supply.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD156091/2021-2022:Steel reinforcement for RCC work including straightening , cutting , bending and placing in position and binding all complete.
14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
90.12.5.38:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm
90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
90.12.5.42:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm
7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
OD156093/2021-2022:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 6 sq. mm (22mm)
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.16:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
90.16.2.4:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class)
OD156147/2021-2022:Supply and fixing the following accessories in the existing meter board and giving connections etc.(32 A, 2 Way neutral links mounted on DMC/SMC base)
OD156148/2021-2022:Supply and fixing the following accessories in the existing meter board and giving connections etc.(32, HRC Fuse Base with HRC Fuse link)
OD156149/2021-2022:Supply and installation of thermoplastic hinged meter board IP65 of size600X300X214 with meter fixing railsusing required bolts nuts etc. as required
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD156154/2021-2022:S & F 4 pole power contactors AC1 rating up to 25A 4 pole
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.5:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
OD42/2022-2023:Supplying and fixing timer switch, 24hr programmable with IP 53 cover (Legrand MaxiRex 4QTB or equivalant)
OD43/2022-2023:Provision for horizontal direction drilling for UG service cable for laying protection pipe and obtaining permission from PWD/KWA/BSNL and other related authority as required.
OD45/2022-2023:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade weather proof 4 core copper conductor including giving necessary connections of the following sizes. 6 sq mm
OD50/2022-2023:Providing and fixing Danger notice board 250x200mm enamelled in existing panel and giving connection complete
OD51/2022-2023:Painting letters or figuresof the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm height
OD52/2022-2023:Demolishing the existing 1:4:8 cement concrete manually / by mechanical means including disposal of material within 50 meters lead as per direction of Engineer - in - charge.
CK Engineering Contractors
Kittu Electricals private limited
Bidder Name
Kittu Electricals private limited
CK Engineering Contractors
candelaengineering corporation
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_733469.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .