Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | L1 | Accepted-AOC AWARDED | |
| 2 | L2₹10.4 L+₹18,264.80 (1.78%)Rejected-AOC | L2 | Rejected-AOC SECOND | |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC | |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance PAKKAVEEDU MARAMVAZHIPATH MURATHUM P O 679331 | MALAPPURAM | KERALA | 679331 | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC | |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹12.8 L
EMD Value
₹32,040
Closing Date
7 Nov 2019, 5:00 pmClosed
RAZIF M
OFFICE OF THE ASSISTANT ENGINEER, LSGD SECTION, MOOTHEDAM GP
63/20 - COMPOUND WALL, GATE IN PHC
2019_LSGD_314789_3
3A/AE/LSGD/MTDM/2019-20
Open Tender
Civil Works - Buildings
Item Rate
120 days
MOOTHEDAM
63/20 - COMPOUND WALL, GATE IN PHC
4 documents required · 4 mandatory
₹2,500
Yes
online
₹32,040
Yes
9 Jan 2020
31 Oct 2019
11 Nov 2019
31 Oct 2019
7 Nov 2019
31 Oct 2019
Amount
Compound wall and gate
15.7.1 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar
15.9.1 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In Lime Mortor
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
od347524/2019_2020 : Random rubble masonry with hard stone in foundation and plinth using department materials up to plinth level with:<br>Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
50.6.1.8 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
od347528/2019_2020 : Brick work / Solid block masonry using department materials of size 40x20x15cm or nearest available size for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
od347534/2019_2020 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with<br>Aluminium Composite Panel Cladding, with open grooves for linear as well as<br>curvilinear portions of the building , for all heights and all levels etc. including:<br>a) Structural analysis & design and preparation of shop drawings for pressure<br>equalisation or rain screen principle as required, proper drainage of water to make<br>it watertight including checking of all the structural and functional design.<br>b) Providing, fabricating and supplying and fixing panels of aluminium composite<br>panel cladding in pan shape in metalic colour of approved shades made out of<br>4mm thick aluminium composite panel material consisting of 3mm thick FR grade<br>mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The<br>aluminium composite panel cladding sheet shall be coil coated, with Kynar<br>500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour<br>and shade on face # 1 and polymer (Service) coating on face # 2 as specified using<br>stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer<br>rods etc.<br>c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised<br>with serrations and serrated washers to arrest the wind load movement, fasteners,<br>SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to<br>prevent bi-metallic contacts all complete required to perform as per specification<br>and drawing The item includes cost of all material & labour component, the cost of<br>all mock ups at site, cost of all samples of the individual components for testing in<br>an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall<br>with aluminium composite panel cladding till the handing over of the building for<br>occupation. Base frame work for ACP cladding is payable under the relevant<br>aluminium item.s The Contractor shall provide curtain wall with aluminium<br>composite panel cladding, having all the performance characteristics all complete<br>, as per the Architectural drawings, as per item description, as specified, as per the<br>approved shop drawings and as directed by the Engineer-in-Charge.<br>However, for the purpose of payment, only the actual area on the external face of<br>the curtain wall with Aluminum Composite Panel Cladding (including width of<br>groove) shall be measured in sqm. up to two decimal places.
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Concrete Protection wall
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
FAISAL P
Bidder Name
FAISAL P
VASU MALAMKUTH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_433510.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .