Infrastructural Improvement of Parcel Offices at Ambala Cantt,Rupnagar,Una Himachal,Nangal Dam ,Kalka,Yamuna nagar Jagadhari,Patiala, Dhuri & Abohar Station over ambala division.
OT-108-UMB-2026-27~NR
OT-108-UMB-2026-27
Open
Works - General
8 Months
Yamunanagar, Haryana
₹0
₹2.4 L
17 Jul 2026
25 Jun 2026
3 Jul 2026
01-Part "A" for DSR-2021 Items (Infrastructural Improvement of Parcel
02-Part "B" for IRUSSOR-2021 items (Infrastructural Improvement of
03-Part "C" for DSR-2021 Items (Infrastructural Improvement of Parcel
04-Part "D" for DSR-2021 items (Infrastructural Improvement of Parcel
05-Part "E" for IRUSSOR-2021 items (Infrastructural Improvement of
06-Part "F" for NS items (Infrastructural Improvement of Parcel Offices
Providing and fixing of wall panelling on grid made of PVC profile section of size 1 21mm x 17mm x 1.5 mm filled with UPVC profile section of size 150mm x 10mm x 1.0mm. The edge and periphery covered by extruded PVC beeding of section 28mm x 12mm x 1.0mm complete job including fixing with screws, dash fasteners and other accessories as required Above/
07-Part "G" for DSR-2021 items (Infrastructural Improvement of Parcel
08-Part "H" for IRUSSOR-2021 items (Infrastructural Improvement of
09-Part "I" for NS items (Infrastructural Improvement of Parcel Offices at
Providing and fixing of wall paneling on grid made of PVC profile section of size 1 21mm x 17mm x 1.5 mm filled with UPVC profile section of size 150mm x 10mm x 1.0mm. The edge and periphery covered by extruded PVC beeding of section 28mm x 12mm x 1.0mm complete job including fixing with screws, dash fasteners and other accessories as required.
Supplying printing and fixing banner made of Flex Fibre Cloth with digital printing as per Railways approved matter, colour, pattern etc. complete job Above/
10-Part "J" for DSR-2021 items (Infrastructural Improvement of Parcel
Cantt Station under ADEN/UMB.)
AMBALA DIVISION-ENGG/NORTHERN RLY
Item- 1 %age above , at par or below on all Chapter of DSR 2021 Edition.
S No. Item No Description of Item Unit Qty Rate Amount
2.0 EARTH WORK
Earth work in excavation by mechanical
means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m
2.6 in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth
lead upto 50 m and lift upto 1.5 m, as directed
by Engineer-in-charge.
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
derived from natural sources : 8 graded stone
aggregate 40 mm nominal size derived from
natural sources)
5.0 REINFORCED CEMENT CONCRETE
5.1S CAST IN SITU
Providing and laying in position specified
grade of reinforced cement concrete,
5.1 excluding the cost of centering, shuttering,
finishing and reinforcement - All work up to
derived from natural sources: 3 graded stone
aggregate 20 mm nominal size derived from
natural sources)
5.9S FORM WORK
Centering and shuttering including strutting,
propping etc. and removal of form for
5.9.1 Foundations, footings, bases of columns, etc. Sqm 50 307.95 15397.5
for mass concrete
5.9.5 Lintels, beams, plinth beams, girders, Sqm 50 608.35 30417.5
bressumers and cantilevers
5.22S STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete upto plinth
5.22.6 Thermo-Mechanically Treated bars of grade Kg 3000 89.65 268950
Fe-500D or more.
6.0 MASONRY WORK
Brick work with common burnt clay F.P.S. (non
6.1 modular) bricks of class designation 7.5 in
foundation and plinth in:
Brick work with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V
level in all shapes and sizes in :
8.0 CLADDING WORK
8.20S STONE WORK DRY CLADDING
AMBALA DIVISION-ENGG/NORTHERN RLY
8.31 Providing and fixing Ist quality ceramic glazed Sqm 120 1063.45 127614
wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of
approved make, in all colours, shades except
burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting,
risers of steps and dados, over 12 mm thick
bed of cement mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white
cement mixed with pigment of matching
shade complete.
8.32 Designing, fabricating, testing, installing and Sqm 148 4474.2 662181.6
fixing in position Curtain Wall with Aluminium
Composite Panel Cladding, with open grooves
for linear as well as curvilinear portions of the
building , for all heights and all levels etc.
including: (a) Structural analysis & design and
preparation of shop drawings for pressure
equalisation or rain screen principle as
required, proper drainage of water to make it
watertight including checking of all the
structural and functional design. (b) Providing,
fabricating and supplying and fixing panels of
aluminium composite panel cladding in pan
shape in metalic colour of approved shades
made out of 4mm thick aluminium composite
panel material consisting of 3mm thick FR
grade mineral core sandwiched between two
Aluminium sheets (each 0.5mm thick). The
aluminium composite panel cladding sheet
shall be coil coated, with Kynar 500 based
PVDF / Lumiflon based fluoropolymer resin
coating of approved colour and shade on face
# 1 and polymer (Service) coating on face # 2
as specified using stainless steel screws, nuts,
bolts, washers, cleats, weather silicone
sealant, backer rods etc. (c) The fastening
brackets of Aluminium alloy 6005 T5 / MS with
Hot Dip Galvanised with serrations and
11 serrated washers to arrest the wind load
movement, fasteners, SS 316 Pins and anchor
bolts of approved make in SS 316, Nylon
separators to prevent bi-metallic contacts all
complete required to perform as per
specification and drawing The item includes
cost of all material & labour component, the
cost of all mock ups at site, cost of all samples
of the individual components for testing in an
approved laboratory, field tests on the
assembled working curtain wall with
aluminium composite panel cladding, cleaning
and protection of the curtain wall with
aluminium composite panel cladding till the
handing over of the building for occupation.
Base frame work for ACP cladding is payable
under the relevant aluminium item.s The
Contractor shall provide curtain wall with
aluminium composite panel cladding, having
all the performance characteristics all
complete , as per the Architectural drawings,
as per item description, as specified, as per
the approved shop drawings and as directed
by the Engineer-in-Charge. However, for the
purpose of payment, only the actual area on
the external face of the curtain wall with
Aluminum Composite Panel Cladding
(including width of groove) shall be measured
in sqm. up to two decimal places.
10.0 STEEL WORK
AMBALA DIVISION-ENGG/NORTHERN RLY
10.1 Structural steel work in single section, fixed Kg 3000 93.05 279150
with or without connecting plate, including
12 cutting, hoisting, fixing in position and
applying a priming coat of approved steel
primer all complete.
10.2 Structural steel work riveted, bolted or welded Kg 2500 111.95 279875
in built up sections, trusses and framed work,
13 including cutting, hoisting, fixing in position
and applying a priming coat of approved steel
primer all complete.
Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position
and applying a priming coat of approved steel
primer, including welding and bolted with
special shaped washers etc. complete.
10.16.3 Electric resistance or induction butt welded Kg 3000 140.85 422550
11.0 FLOORING
11.41S VITRIFIED FLOOR TILES
Providing and laying Vitrified tiles in floor in
different sizes (thickness to be specified by
the manufacturer) with water absorption less
than 0.08% and conforming to IS:15622, of
approved brand & manufacturer, in all colours
and shade, laid on 20 mm thick cement mortar
1:4 (1 cement: 4 coarse sand) jointing with
11.41A grey cement slurry @3.3 kg/sqm including
grouting the joints with white cement and
matching pigments etc. The tiles must be cut
with the zero chipping diamond cutter only .
Laying of tiles will be done with the notch
trowel, plier, wedge, clips of required
thickness, leveling system and rubber mallet
for placing the tiles gently and easily.
Glazed vitrified floor tiles polished finish of
11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
12.0 ROOFING
Providing, fixing and embedding sand cast iron
accessories for rain water pipes in the
12.40 masonry surrounded with 12 mm thick cement
mortar of the same mix, as that of masonry
(lead caulking will be paid for separately):
Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes conforming to IS :
13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap
for thermal expansion, (i) Single socketed
Providing and fixing on wall face unplasticised
- PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.5 Bend 87.5 degrees
13.0 FINISHING
13.11S CEMENT PLASTER IN TWO COATS
AMBALA DIVISION-ENGG/NORTHERN RLY
13.44S EXTERIOR FINISHING
Finishing with Deluxe Multi surface paint
13.48 system for interiors and exteriors using Primer
as per manufacturers specifications :
13.48.1 Two or more coats applied on walls @ 1.25 Sqm 1502.68 158.95 238850.99
20 ltr/10 sqm over and including one coat of
Special primer applied @ 0.75 ltr /10 sqm
17.0 SANITARY INSTALLATIONS
Providing and fixing water closet squatting
pan (Indian type W.C. pan ) with 100 mm sand
cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe,
17.1 with manually controlled device (handle lever)
conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and
making good the walls and floors wherever
17.1.1 White Vitreous china Orissa pattern W.C. pan Each 2 5781.35 11562.7
21 of size 580x440 mm with integral type foot
Providing and fixing white vitreous china
pedestal type water closet (European type
W.C. pan) with seat and lid, 10 litre low level
white P.V.C. flushing cistern, including flush
17.2 pipe, with manually controlled device (handle
lever), conforming to IS : 7231, with all fittings
and fixtures complete, including cutting and
making good the walls and floors wherever
17.2.1 W.C. pan with ISI marked white solid plastic Each 2 5540.55 11081.1
Providing and fixing wash basin with C.I.
brackets, 15 mm C.P. brass pillar taps, 32 mm
17.7 C.P. brass waste of standard pattern, including
painting of fittings and brackets, cutting and
making good the walls wherever require:
17.7.3 White Vitreous China Wash basin size 550x400 Each 2 2040.85 4081.7
mm with a pair of 15 mm C.P. brass pillar taps
17.8 Providing and fixing white vitreous china Each 2 1500.05 3000.1
pedestal for wash basin completely recessed
at the back for the reception of pipes and
17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet Each 2 299.35 598.7
with flexible tube upto 1 metre long with S.S.
25 triangular plate to Eureopean type W.C. of
quality and make as approved by Engineer - in
Providing and fixing mirror of superior glass (of
approved quality) and of required shape and
17.32 size with plastic moulded frame of approved
make and shade with 6 mm thick hard board
17.34 Providing and fixing toilet paper holder :
18.0 WATER SUPPLY
18.4S PP-R PIPES
AMBALA DIVISION-ENGG/NORTHERN RLY
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes
confirming to IS 15801, UV stabilized & anti -
microbial fusion welded, having thermal
stability for hot & cold water supply, including
all PP - R plain & brass threaded polypropylene
random fittings, i/c fixing the pipe with clamps
at 1.00 m spacing. This includes testing of
joints complete as per direction of Engineer-in-
Charge. -Internal Exposed on walls
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes
confirming to IS:15801 UV stabilized & anti -
microbial fusion welded, having thermal
18.6 stability for hot & cold water supply, including
all PP - R plain & brass threaded polypropylene
random fittings, including trenching, refilling &
testing of joints complete as per direction of
Engineer-in-Charge. -External work
18.15S BRASS FITTINGS
Providing and fixing gun metal gate valve with
C.I. wheel of approved quality (screwed end) :
Providing and fixing ball valve (brass) of
18.18 approved quality, High or low pressure, with
plastic floats complete :
Providing and fixing uplasticised PVC
connection pipe with brass unions :
18.21.2 45 cm length
C.I. SLUICE VALVES/ FIRE HYDRANTS &
18.48 Providing and placing on terrace (at all floor Litre 1000 9.7 9700
levels) polyethylene water storage tank, IS :
12701 marked, with cover and suitable locking
arrangement and making necessary holes for
inlet, outlet and overflow pipes but without
fittings and the base support for tank.
18.49S C.P. BRASS FITTINGS
Providing and fixing C.P. brass angle valve for
18.53 basin mixer and geyser points of approved
quality conforming to IS:8931
18.54S PTMT FITTINGS
Providing and fixing PTMT bib cock of
approved quality and colour.
18.54.1 15mm nominal bore, 86 mm long, weighing Each 12 109.85 1318.2
not less than 88 gms
Providing and fixing PTMT pillar cock of
approved quality and colour.
not less than 110 gms
Providing and fixing PTMT, push cock of
approved quality and colour.
not less than 75 gms
18.59S AIR VALVE & WATER METER (BULK TYPE)
AMBALA DIVISION-ENGG/NORTHERN RLY
18.65 Providing and fixing PTMT soap Dish Holder Each 4 96.75 387
having length of 138mm, breadth 102mm,
38 height of 75mm with concealed fitting
arrangements, weighing not less than 106
19.0 DRAINAGE
Providing and fixing square-mouth S.W. gully
trap class SP-1 complete with C.I. grating brick
masonry chamber with water tight C.I. cover
19.4 with frame of 300 x300 mm size (inside) the
weight of cover to be not less than 4.50 kg and
frame to be not less than 2.70 kg as per
standard design:
Providing and laying non-pressure NP2 class
(light duty) R.C.C. pipes with collars jointed
19.6 with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement : 2 fine sand)
including testing of joints etc. complete :
21.0 ALUMINIUM WORK
Providing and fixing aluminium work for doors,
windows, ventilators and partitions with
extruded built up standard tubular sections/
appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS:
1285, fixing with dash fasteners of required
dia and size, including necessary filling up the
gaps at junctions, i.e. at top, bottom and sides
with required EPDM rubber/ neoprene gasket
etc. Aluminium sections shall be smooth, rust
free, straight, mitred and jointed mechanically
wherever required including cleat angle,
Aluminium snap beading for glazing /
paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and
the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for
21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness Kg 200 466.3 93260
of powder coating 50 micron)
For shutters of doors, windows & ventilators
including providing and fixing hinges/ pivots
and making provision for fixing of fittings
wherever required including the cost of EPDM
rubber / neoprene gasket required (Fittings
shall be paid for separately)
21.1.2.2 Powder coated aluminium (minimum thickness Kg 180 564.8 101664
of powder coating 50 micron)
Providing and fixing glazing in aluminium door,
window, ventilator shutters and partitions etc.
with EPDM rubber / neoprene gasket etc.
21.3 complete as per the architectural drawings
and the directions of engineer-in-charge .
(Cost of aluminium snap beading shall be paid
in basic item):
21.3.2 With float glass panes of 5 mm thickness Sqm 30 1325.55 39766.5
(weight not less than 12.50 kg/sqm)
Schedule 02-Part "B" for IRUSSOR-2021 items (Infrastructural Improvement of Parcel Offices at
Ambala Cantt Station under ADEN/UMB.)
Item- 1 %age above , at par or below on all items of all chapter of SOR 2021 edition.
S No. Item No Description of Item Unit Qty Rate Amount
AMBALA DIVISION-ENGG/NORTHERN RLY
Hiring of machinery for minor miscellaneous
works for short duration including
operator/driver, fuel, lubricants and
consumable. The contractor shall arrange all
statutory permits as required by rules and
regulations prevailing in the area of work.
Payment shall be made for actual working
1 211201 JCB Backhoe Loaders 3DX Plus or similar with Hour 30.00 858.69 25760.70
minimum 1.10 cum bucket capacity
Schedule 03-Part "C" for DSR-2021 Items (Infrastructural Improvement of Parcel Offices at
Rupnagar, Una Himachal & Nangal dam Station under ADEN/SIR.)
Item- 1 %age above , at par or below on all Chapter of DSR 2021 Edition.
S No. Item No Description of Item Unit Qty Rate Amount
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
derived from natural sources : 8 graded stone
aggregate 40 mm nominal size derived from
natural sources)
Providing and laying cement concrete in
retaining walls, return walls, walls (any
thickness) including attached pilasters,
columns, piers, abutments, pillars, posts,
4.2 struts, buttresses, string or lacing courses,
parapets, coping, bed blocks, anchor blocks,
plain window sills, fillets, sunken floor etc., up
to floor five level, excluding the cost of
centering, shuttering and finishing:
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources).
Centering and shuttering including strutting,
propping etc. and removal of form work for :
3 4.3.1 Foundations, footings, bases for columns Sqm 40 307.95 12318
6.0 MASONRY WORK
Brick work with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V
level in all shapes and sizes in :
10.0 STEEL WORK
10.2 Structural steel work riveted, bolted or welded Kg 10000 111.95 1119500
in built up sections, trusses and framed work,
5 including cutting, hoisting, fixing in position
and applying a priming coat of approved steel
primer all complete.
Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position
and applying a priming coat of approved steel
primer, including welding and bolted with
special shaped washers etc. complete.
10.16.3 Electric resistance or induction butt welded Kg 3250 140.85 457762.5
11.0 FLOORING
AMBALA DIVISION-ENGG/NORTHERN RLY
11.5 62 mm thick cement concrete flooring with Sqm 450 928.65 417892.5
concrete hardener topping, under layer 50 mm
thick cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20mm
nominal size) and top layer 12mm thick
cement hardener consisting of mix 1:2 (1
7 cement hardener mix : 2 graded stone
aggregate, 6mm nominal size) by volume,
hardening compound mixed @ 2 litre per 50
kg of cement or as per manufacture's
specifications. This includes cost of cement
slurry, but excluding the cost of nosing of
steps etc. complete.
12.0 ROOFING
Providing and fixing on wall face unplasticised
- PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.50 Providing and fixing precoated galvanised iron Sqm 400 671.55 268620
profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-
charge) 0.50 mm (+ 0.05 %) total coated
thickness with zinc coating 120 grams per sqm
as per IS: 277, in 240 mpa steel grade, 5-7
microns epoxy primer on both side of the
sheet and polyester top coat 15-18 microns.
Sheet should have protective guard film of 25
8 microns minimum to avoid scratches during
transportation and should be supplied in
single length upto 12 metre or as desired by
Engineer-in-charge. The sheet shall be fixed
using self drilling /self tapping screws of size
(5.5x 55 mm) with EPDM seal, complete upto
any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters
and trusses and including cutting to size and
shape wherever required.
13.0 FINISHING
13.1S CEMENT PLASTER (IN FINE SAND)
13.1 12 mm cement plaster of mix :
Painting with synthetic enamel paint of
13.61 approved brand and manufacture to give an
Schedule 04-Part "D" for DSR-2021 items (Infrastructural Improvement of Parcel Offices at Kalka
Station under ADEN/SML.)
Item- 1 %age above , at par or below on all Chapter of DSR 2021 Edition.
S No. Item No Description of Item Unit Qty Rate Amount
1.0 CARRIAGE OF MATERIALS
By Mechanical Transport including
loading,unloading and stacking
1.1.18 Disposal of moorum/building rubbish/ malba/ cum 5 411.3 2056.5
similar unserviceable, dismantled or waste
material by mechanical transport including
1 loading, transporting, unloading to approved
municipal dumping ground for lead upto 10 km
for all lifts, complete as per directions of
Engineer-in-charge.
2.0 EARTH WORK
AMBALA DIVISION-ENGG/NORTHERN RLY
Earth work in excavation by mechanical
means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m
2.6 in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth
lead upto 50 m and lift upto 1.5 m, as directed
by Engineer-in-charge.
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
derived from natural sources : 4 graded stone
aggregate 20 mm nominal size derived from
natural sources)
derived from natural sources : 8 graded stone
aggregate 40 mm nominal size derived from
natural sources)
5.0 REINFORCED CEMENT CONCRETE
5.1S CAST IN SITU
Providing and laying in position specified
grade of reinforced cement concrete,
5.1 excluding the cost of centering, shuttering,
finishing and reinforcement - All work up to
derived from natural sources: 3 graded stone
aggregate 20 mm nominal size derived from
natural sources)
5.3 Reinforced cement concrete work in beams, cum 2 10719.3 21438.6
suspended floors, roofs having slope up to 15
degree landings, balconies, shelves, chajjas,
lintels, bands, plain window sills, staircases
and spiral stair cases above plinth level up to
6 floor five level, excluding the cost of centering,
shuttering, finishing and reinforcement with
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources).
5.9S FORM WORK
Centering and shuttering including strutting,
propping etc. and removal of form for
5.9.3 Suspended floors, roofs, landings, balconies Sqm 10 766.55 7665.5
and access platform
5.22S STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete above plinth
5.22A.6 Thermo-Mechanically Treated bars of grade Kg 400 89.65 35860
Fe-500D or more.
6.0 MASONRY WORK
Brick work with common burnt clay F.P.S. (non
6.1 modular) bricks of class designation 7.5 in
foundation and plinth in:
Brick work with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V
level in all shapes and sizes in :
AMBALA DIVISION-ENGG/NORTHERN RLY
8.0 CLADDING WORK
8.20S STONE WORK DRY CLADDING
8.31 Providing and fixing Ist quality ceramic glazed Sqm 20 1063.45 21269
wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of
approved make, in all colours, shades except
burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting,
risers of steps and dados, over 12 mm thick
bed of cement mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white
cement mixed with pigment of matching
shade complete.
9.0 WOOD AND P.V.C. WORK
ANODISED ALUMINIUM FITTINGS (ALL FITTINGS
SHALL BE ISI MARKED)
Providing and fixing aluminium tower bolts, ISI
marked, anodised (anodic coating not less
9.97 than grade AC 10 as per IS : 1868 )
transparent or dyed to required colour or
shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor
door stopper, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour
and shade, with necessary screws etc.
10.0 STEEL WORK
10.2 Structural steel work riveted, bolted or welded Kg 50 111.95 5597.5
in built up sections, trusses and framed work,
14 including cutting, hoisting, fixing in position
and applying a priming coat of approved steel
primer all complete.
Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position
and applying a priming coat of approved steel
primer, including welding and bolted with
special shaped washers etc. complete.
10.22 Welding by gas or electric plant including cm 50 3.4 170
transportation of plant at site etc. complete.
Steel work welded in built up sections/ framed
work, including cutting, hoisting, fixing in
10.25 position and applying a priming coat of
approved steel primer using structural steel
etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, Kg 50 142.3 7115
brackets, gates and similar works
11.0 FLOORING
Cement concrete flooring 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate)
11.3 finished with a floating coat of neat cement,
including cement slurry, but excluding the cost
of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone Sqm 20 545 10900
11.41S VITRIFIED FLOOR TILES
AMBALA DIVISION-ENGG/NORTHERN RLY
Providing and laying vitrified floor tiles in
different sizes (thickness to be specified by
the manufacturer) with water absorption less
than 0.08% and conforming to IS: 15622, of
approved make, in all colours and shades, laid
on 20mm thick cement mortar 1:4 (1 cement :
4 coarse sand), jointing with grey cement
slurry @ 3.3 kg/ sqm including grouting the
joints with white cement and matching
pigments etc., complete.
12.0 ROOFING
Providing, fixing and embedding sand cast iron
accessories for rain water pipes in the
12.40 masonry surrounded with 12 mm thick cement
mortar of the same mix, as that of masonry
(lead caulking will be paid for separately):
Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes conforming to IS :
13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap
for thermal expansion, (i) Single socketed
Providing and fixing on wall face unplasticised
- PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.5 Bend 87.5 degrees
13.0 FINISHING
13.1S CEMENT PLASTER (IN FINE SAND)
13.1 12 mm cement plaster of mix :
13.80 Providing and applying white cement based Sqm 30 123.85 3715.5
putty of average thickness 1 mm, of approved
23 brand and manufacturer, over the plastered
wall surface to prepare the surface even and
smooth complete.
Applying priming coats with primer of
13.85 approved brand and manufacture, having low
VOC (Volatile Organic Compound ) content.
Distempering with 1st quality acrylic
distember (Ready mix) having VOC content
less than 50 grams/ litre of approved brand
and manufacture to give an even shade :
13.91 Removing dry or oil bound distemper, water Sqm 70 20.85 1459.5
proofing cement paint and the like by
25 scrapping, sand papering and preparing the
surface smooth including necessary repairs to
scratches etc. complete.
Painting with synthetic enamel paint of
13.99 approved brand and manufacture of required
colour to give an even shade :
14.0 REPAIRS TO BUILDING
14.72S FINISHING
AMBALA DIVISION-ENGG/NORTHERN RLY
14.75 Repair to plaster of thickness 12mm to 20 mm Sqm 8 540.35 4322.8
in patches of area 2.5 sqm and under,
including cutting the patch in proper shape,
raking out joints and preparing plastering the
wall surface with white cement based polymer
modified self curing mortar, including disposal
of rubbish, all complete as per the direction of
Engineer-In-Charge.
15.0 DISMANTLING AND DEMOLISHING
Demolishing cement concrete manually/ by
mechanical means including disposal of
material within 50 metres lead as per direction
of Engineer - in - charge.
15.2.1 Nominal concrete 1:3:6 or richer mix (i/c cum 2 2007.1 4014.2
equivalent design mix)
15.3 Demolishing R.C.C. work manually/ by cum 1 2928.1 2928.1
mechanical means including stacking of steel
29 bars and disposal of unserviceable material
within 50 metres lead as per direction of
Engineer - in- charge.
Demolishing brick work manually/ by
mechanical means including stacking of
15.7 serviceable material and disposal of
unserviceable material within 50 metres lead
as per direction of Engineer-in-charge.
Dismantling doors, windows and clerestory
windows (steel or wood) shutter including
chowkhats, architrave, holdfasts etc. complete
and stacking within 50 metres lead :
Taking out doors, windows and clerestory
15.13 window shutters (steel or wood) including
stacking within 50 metres lead :
Dismantling tile work in floors and roofs laid in
15.23 cement mortar including stacking material
within 50 metres lead.
17.0 SANITARY INSTALLATIONS
Providing and fixing water closet squatting
pan (Indian type W.C. pan ) with 100 mm sand
cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe,
17.1 with manually controlled device (handle lever)
conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and
making good the walls and floors wherever
17.1.1 White Vitreous china Orissa pattern W.C. pan Each 1 5781.35 5781.35
36 of size 580x440 mm with integral type foot
Providing and fixing white vitreous china
pedestal type water closet (European type
W.C. pan) with seat and lid, 10 litre low level
white P.V.C. flushing cistern, including flush
17.2 pipe, with manually controlled device (handle
lever), conforming to IS : 7231, with all fittings
and fixtures complete, including cutting and
making good the walls and floors wherever
17.2.1 W.C. pan with ISI marked white solid plastic Each 1 5540.55 5540.55
AMBALA DIVISION-ENGG/NORTHERN RLY
Providing and fixing white vitreous china flat
back half stall urinal of size 580x380x350 mm
with white PVC automatic flushing cistern, with
fittings, standard size C.P. brass flush pipe,
spreaders with unions and clamps (all in C.P.
brass) with waste fitting as per IS : 2556, C.I.
trap with outlet grating and other couplings in
C.P. brass, including painting of fittings and
cutting and making good the walls and floors
wherever required :
17.5.1 Single half stall urinal with 5 litre P.V.C. Each 1 10128.3 10128.3
automatic flushing cistern
Providing and fixing wash basin with C.I.
brackets, 15 mm C.P. brass pillar taps, 32 mm
17.7 C.P. brass waste of standard pattern, including
painting of fittings and brackets, cutting and
making good the walls wherever require:
17.7.2 White Vitreous China Wash basin size 630x450 Each 1 1913.75 1913.75
mm with a single 15 mm C.P. brass pillar tap
17.31 Providing and fixing 600x450 mm beveled Each 1 1411.15 1411.15
edge mirror of superior glass (of approved
40 quality) complete with 6 mm thick hard board
ground fixed to wooden cleats with C.P. brass
screws and washers complete.
17.33 Providing and fixing 600x120x5 mm glass Each 1 942.15 942.15
shelf with edges round off, supported on
anodised aluminium angle frame with C.P.
brass brackets and guard rail complete fixed
with 40 mm long screws, rawl plugs etc.,
18.0 WATER SUPPLY
18.4S PP-R PIPES
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes
confirming to IS 15801, UV stabilized & anti -
microbial fusion welded, having thermal
stability for hot & cold water supply, including
all PP - R plain & brass threaded polypropylene
random fittings, i/c fixing the pipe with clamps
at 1.00 m spacing. This includes testing of
joints complete as per direction of Engineer-in-
Charge. -Internal Exposed on walls
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes
confirming to IS:15801, UV stabilized & anti -
microbial fusion welded, having thermal
stability for hot & cold water supply, including
all PP - R plain & brass threaded polypropylene
18.5 random fittings, i/c fixing the pipe with clamps
at 1.00 m spacing. This includes the cost of
cutting chases and making good the same
including testing of joints complete as per
direction of Engineer-in-Charge. -Concealed
work,including cutting chases and making
good the wall etc.
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes
confirming to IS:15801 UV stabilized & anti -
microbial fusion welded, having thermal
18.6 stability for hot & cold water supply, including
all PP - R plain & brass threaded polypropylene
random fittings, including trenching, refilling &
testing of joints complete as per direction of
Engineer-in-Charge. -External work
AMBALA DIVISION-ENGG/NORTHERN RLY
18.49S C.P. BRASS FITTINGS
Providing and fixing C.P. brass bib cock of
approved quality conforming to IS:8931 :
Providing and fixing C.P. brass long nose bib
cock of approved quality conforming to IS
standards and weighing not less than 810
Providing and fixing C.P. brass long body bib
cock of approved quality conforming to IS
standards and weighing not less than 690
Providing and fixing C.P. brass angle valve for
18.53 basin mixer and geyser points of approved
quality conforming to IS:8931
18.53A Providing and fixing C.P. Brass extension Each 1 61.7 61.7
nipple (size 15mmx50mm) of approved make
and quality as per direction of Engineer-in-
22.0 WATER PROOFING
22.9 Providing and laying six courses water Sqm 50 675 33750
proofing treatment with bitumen felt over
roofs consisting of first, third and fifth course
of blown bitumen 85/25 or 90/15 conforming
to IS : 702 applied hot @ 1.45, 1.20 and 1.45
Kg per square metre of area respectively,
50 second and fourth courses of roofing felt type
3 grade I conforming to IS : 1322 (Hessian
based self finished bitumen felt) , sixth and
final course of stone grit 6 mm and down size
or pea sized gravel spread at 6 cubic
decimeter per sqm including preparation of
surface but excluding grading, complete.
22.12 Supplying and applying bituminous solution Sqm 50 50.25 2512.5
51 primer on roof and / or wall surface at 0.24
22.14 Grading roof for water proofing treatment with
Schedule 05-Part "E" for IRUSSOR-2021 items (Infrastructural Improvement of Parcel Offices at
Kalka Station under ADEN/SML.)
Item- 1 %age above , at par or below on all items of all chapter of SOR 2021 edition.
S No. Item No Description of Item Unit Qty Rate Amount
Hiring of machinery for minor miscellaneous
works for short duration including
operator/driver, fuel, lubricants and
consumable. The contractor shall arrange all
statutory permits as required by rules and
regulations prevailing in the area of work.
Payment shall be made for actual working
1 211201 JCB Backhoe Loaders 3DX Plus or similar with Hour 5.00 858.69 4293.45
minimum 1.10 cum bucket capacity
Schedule 07-Part "G" for DSR-2021 items (Infrastructural Improvement of Parcel Offices at Yamuna
nagar Jagadhari station under ADEN/SRE.)
Item- 1 %age above , at par or below on all Chapter of DSR 2021 Edition.
S No. Item No Description of Item Unit Qty Rate Amount
1.0 CARRIAGE OF MATERIALS
By Mechanical Transport including
loading,unloading and stacking
AMBALA DIVISION-ENGG/NORTHERN RLY
1.1.18 Disposal of moorum/building rubbish/ malba/ cum 5 411.3 2056.5
similar unserviceable, dismantled or waste
material by mechanical transport including
1 loading, transporting, unloading to approved
municipal dumping ground for lead upto 10 km
for all lifts, complete as per directions of
Engineer-in-charge.
2.0 EARTH WORK
Earth work in excavation by mechanical
means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m
2.6 in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth
lead upto 50 m and lift upto 1.5 m, as directed
by Engineer-in-charge.
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
derived from natural sources : 4 graded stone
aggregate 20 mm nominal size derived from
natural sources)
derived from natural sources : 8 graded stone
aggregate 40 mm nominal size derived from
natural sources)
5.0 REINFORCED CEMENT CONCRETE
5.1S CAST IN SITU
Providing and laying in position specified
grade of reinforced cement concrete,
5.1 excluding the cost of centering, shuttering,
finishing and reinforcement - All work up to
derived from natural sources: 3 graded stone
aggregate 20 mm nominal size derived from
natural sources)
5.9S FORM WORK
Centering and shuttering including strutting,
propping etc. and removal of form for
5.9.3 Suspended floors, roofs, landings, balconies Sqm 10 766.55 7665.5
and access platform
5.22S STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete above plinth
5.22A.6 Thermo-Mechanically Treated bars of grade Kg 650 89.65 58272.5
Fe-500D or more.
6.0 MASONRY WORK
Brick work with common burnt clay F.P.S. (non
6.1 modular) bricks of class designation 7.5 in
foundation and plinth in:
Brick work with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V
level in all shapes and sizes in :
8.0 CLADDING WORK
AMBALA DIVISION-ENGG/NORTHERN RLY
8.20S STONE WORK DRY CLADDING
8.31 Providing and fixing Ist quality ceramic glazed Sqm 20 1063.45 21269
wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of
approved make, in all colours, shades except
burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting,
risers of steps and dados, over 12 mm thick
bed of cement mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white
cement mixed with pigment of matching
shade complete.
9.0 WOOD AND P.V.C. WORK
ANODISED ALUMINIUM FITTINGS (ALL FITTINGS
SHALL BE ISI MARKED)
Providing and fixing aluminium tower bolts, ISI
marked, anodised (anodic coating not less
9.97 than grade AC 10 as per IS : 1868 )
transparent or dyed to required colour or
shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor
door stopper, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour
and shade, with necessary screws etc.
10.0 STEEL WORK
10.2 Structural steel work riveted, bolted or welded Kg 200 111.95 22390
in built up sections, trusses and framed work,
13 including cutting, hoisting, fixing in position
and applying a priming coat of approved steel
primer all complete.
Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position
and applying a priming coat of approved steel
primer, including welding and bolted with
special shaped washers etc. complete.
10.22 Welding by gas or electric plant including cm 50 3.4 170
transportation of plant at site etc. complete.
Steel work welded in built up sections/ framed
work, including cutting, hoisting, fixing in
10.25 position and applying a priming coat of
approved steel primer using structural steel
etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, Kg 160 142.3 22768
brackets, gates and similar works
11.0 FLOORING
Cement concrete flooring 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate)
11.3 finished with a floating coat of neat cement,
including cement slurry, but excluding the cost
of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone Sqm 150 545 81750
11.41S VITRIFIED FLOOR TILES
AMBALA DIVISION-ENGG/NORTHERN RLY
Providing and laying vitrified floor tiles in
different sizes (thickness to be specified by
the manufacturer) with water absorption less
than 0.08% and conforming to IS: 15622, of
approved make, in all colours and shades, laid
on 20mm thick cement mortar 1:4 (1 cement :
4 coarse sand), jointing with grey cement
slurry @ 3.3 kg/ sqm including grouting the
joints with white cement and matching
pigments etc., complete.
12.0 ROOFING
Providing, fixing and embedding sand cast iron
accessories for rain water pipes in the
12.40 masonry surrounded with 12 mm thick cement
mortar of the same mix, as that of masonry
(lead caulking will be paid for separately):
Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes conforming to IS :
13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap
for thermal expansion, (i) Single socketed
Providing and fixing on wall face unplasticised
- PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.5 Bend 87.5 degrees
13.0 FINISHING
13.1S CEMENT PLASTER (IN FINE SAND)
13.1 12 mm cement plaster of mix :
13.80 Providing and applying white cement based Sqm 100 123.85 12385
putty of average thickness 1 mm, of approved
22 brand and manufacturer, over the plastered
wall surface to prepare the surface even and
smooth complete.
Applying priming coats with primer of
13.85 approved brand and manufacture, having low
VOC (Volatile Organic Compound ) content.
Distempering with 1st quality acrylic
distember (Ready mix) having VOC content
less than 50 grams/ litre of approved brand
and manufacture to give an even shade :
13.91 Removing dry or oil bound distemper, water Sqm 100 20.85 2085
proofing cement paint and the like by
24 scrapping, sand papering and preparing the
surface smooth including necessary repairs to
scratches etc. complete.
Painting with synthetic enamel paint of
13.99 approved brand and manufacture of required
colour to give an even shade :
14.0 REPAIRS TO BUILDING
14.72S FINISHING
AMBALA DIVISION-ENGG/NORTHERN RLY
14.75 Repair to plaster of thickness 12mm to 20 mm Sqm 20 540.35 10807
in patches of area 2.5 sqm and under,
including cutting the patch in proper shape,
raking out joints and preparing plastering the
wall surface with white cement based polymer
modified self curing mortar, including disposal
of rubbish, all complete as per the direction of
Engineer-In-Charge.
15.0 DISMANTLING AND DEMOLISHING
Demolishing cement concrete manually/ by
mechanical means including disposal of
material within 50 metres lead as per direction
of Engineer - in - charge.
15.2.1 Nominal concrete 1:3:6 or richer mix (i/c cum 5 2007.1 10035.5
equivalent design mix)
15.3 Demolishing R.C.C. work manually/ by cum 2 2928.1 5856.2
mechanical means including stacking of steel
28 bars and disposal of unserviceable material
within 50 metres lead as per direction of
Engineer - in- charge.
Demolishing brick work manually/ by
mechanical means including stacking of
15.7 serviceable material and disposal of
unserviceable material within 50 metres lead
as per direction of Engineer-in-charge.
Dismantling doors, windows and clerestory
windows (steel or wood) shutter including
chowkhats, architrave, holdfasts etc. complete
and stacking within 50 metres lead :
Taking out doors, windows and clerestory
15.13 window shutters (steel or wood) including
stacking within 50 metres lead :
Dismantling tile work in floors and roofs laid in
15.23 cement mortar including stacking material
within 50 metres lead.
16.0 ROAD WORK
16.49S MISCELLANEOUS
Providing and laying factory made chamfered
edge Cement Concrete paver blocks in
footpath, parks, lawns, drive ways or light
traffic parking etc, of required strength,
thickness & size/ shape, made by table
vibratory method using PU mould, laid in
required colour & pattern over 50mm thick
compacted bed of sand, compacting and
proper embedding/laying of inter locking
paver blocks into the sand bedding layer
through vibratory compaction by using plate
vibrator, filling the joints with sand and cutting
of paver blocks as per required size and
pattern, finishing and sweeping extra sand.
complete all as per direction of Engineer-in-
16.91.1 60mm thick cement concrete paver block of Sqm 10.05 932.35 9373.85
35 M-35 grade with approved colour, design &
17.0 SANITARY INSTALLATIONS
AMBALA DIVISION-ENGG/NORTHERN RLY
Providing and fixing water closet squatting
pan (Indian type W.C. pan ) with 100 mm sand
cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe,
17.1 with manually controlled device (handle lever)
conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and
making good the walls and floors wherever
17.1.1 White Vitreous china Orissa pattern W.C. pan Each 1 5781.35 5781.35
36 of size 580x440 mm with integral type foot
Providing and fixing white vitreous china
pedestal type water closet (European type
W.C. pan) with seat and lid, 10 litre low level
white P.V.C. flushing cistern, including flush
17.2 pipe, with manually controlled device (handle
lever), conforming to IS : 7231, with all fittings
and fixtures complete, including cutting and
making good the walls and floors wherever
17.2.1 W.C. pan with ISI marked white solid plastic Each 1 5540.55 5540.55
Providing and fixing white vitreous china flat
back half stall urinal of size 580x380x350 mm
with white PVC automatic flushing cistern, with
fittings, standard size C.P. brass flush pipe,
spreaders with unions and clamps (all in C.P.
brass) with waste fitting as per IS : 2556, C.I.
trap with outlet grating and other couplings in
C.P. brass, including painting of fittings and
cutting and making good the walls and floors
wherever required :
17.5.1 Single half stall urinal with 5 litre P.V.C. Each 1 10128.3 10128.3
automatic flushing cistern
Providing and fixing wash basin with C.I.
brackets, 15 mm C.P. brass pillar taps, 32 mm
17.7 C.P. brass waste of standard pattern, including
painting of fittings and brackets, cutting and
making good the walls wherever require:
17.7.2 White Vitreous China Wash basin size 630x450 Each 1 1913.75 1913.75
mm with a single 15 mm C.P. brass pillar tap
17.31 Providing and fixing 600x450 mm beveled Each 2 1411.15 2822.3
edge mirror of superior glass (of approved
40 quality) complete with 6 mm thick hard board
ground fixed to wooden cleats with C.P. brass
screws and washers complete.
17.33 Providing and fixing 600x120x5 mm glass Each 2 942.15 1884.3
shelf with edges round off, supported on
anodised aluminium angle frame with C.P.
brass brackets and guard rail complete fixed
with 40 mm long screws, rawl plugs etc.,
18.0 WATER SUPPLY
18.4S PP-R PIPES
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes
confirming to IS 15801, UV stabilized & anti -
microbial fusion welded, having thermal
stability for hot & cold water supply, including
all PP - R plain & brass threaded polypropylene
random fittings, i/c fixing the pipe with clamps
at 1.00 m spacing. This includes testing of
joints complete as per direction of Engineer-in-
Charge. -Internal Exposed on walls
AMBALA DIVISION-ENGG/NORTHERN RLY
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes
confirming to IS:15801, UV stabilized & anti -
microbial fusion welded, having thermal
stability for hot & cold water supply, including
all PP - R plain & brass threaded polypropylene
18.5 random fittings, i/c fixing the pipe with clamps
at 1.00 m spacing. This includes the cost of
cutting chases and making good the same
including testing of joints complete as per
direction of Engineer-in-Charge. -Concealed
work,including cutting chases and making
good the wall etc.
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes
confirming to IS:15801 UV stabilized & anti -
microbial fusion welded, having thermal
18.6 stability for hot & cold water supply, including
all PP - R plain & brass threaded polypropylene
random fittings, including trenching, refilling &
testing of joints complete as per direction of
Engineer-in-Charge. -External work
18.49S C.P. BRASS FITTINGS
Providing and fixing C.P. brass bib cock of
approved quality conforming to IS:8931 :
Providing and fixing C.P. brass long nose bib
cock of approved quality conforming to IS
standards and weighing not less than 810
Providing and fixing C.P. brass long body bib
cock of approved quality conforming to IS
standards and weighing not less than 690
Providing and fixing C.P. brass angle valve for
18.53 basin mixer and geyser points of approved
quality conforming to IS:8931
18.53A Providing and fixing C.P. Brass extension Each 1 61.7 61.7
nipple (size 15mmx50mm) of approved make
and quality as per direction of Engineer-in-
22.0 WATER PROOFING
22.9 Providing and laying six courses water Sqm 100 675 67500
proofing treatment with bitumen felt over
roofs consisting of first, third and fifth course
of blown bitumen 85/25 or 90/15 conforming
to IS : 702 applied hot @ 1.45, 1.20 and 1.45
Kg per square metre of area respectively,
50 second and fourth courses of roofing felt type
3 grade I conforming to IS : 1322 (Hessian
based self finished bitumen felt) , sixth and
final course of stone grit 6 mm and down size
or pea sized gravel spread at 6 cubic
decimeter per sqm including preparation of
surface but excluding grading, complete.
22.12 Supplying and applying bituminous solution Sqm 100 50.25 5025
51 primer on roof and / or wall surface at 0.24
22.14 Grading roof for water proofing treatment with
AMBALA DIVISION-ENGG/NORTHERN RLY
Schedule 08-Part "H" for IRUSSOR-2021 items (Infrastructural Improvement of Parcel Offices at
Yamuna nagar Jagadhari station under ADEN/SRE.)
Item- 1 %age above , at par or below on all items of all chapter of SOR 2021 edition.
S No. Item No Description of Item Unit Qty Rate Amount
Hiring of machinery for minor miscellaneous
works for short duration including
operator/driver, fuel, lubricants and
consumable. The contractor shall arrange all
statutory permits as required by rules and
regulations prevailing in the area of work.
Payment shall be made for actual working
1 211201 JCB Backhoe Loaders 3DX Plus or similar with Hour 10.00 858.69 8586.90
minimum 1.10 cum bucket capacity
Schedule 10-Part "J" for DSR-2021 items (Infrastructural Improvement of Parcel Offices at Patiala,
Dhuri & Abohar station under ADEN/PTA & ADEN/BTI.)
Item- 1 %age above , at par or below on all Chapter of DSR 2021 Edition.
S No. Item No Description of Item Unit Qty Rate Amount
2.0 EARTH WORK
Earth work in excavation by mechanical
means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m
2.6 in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth
lead upto 50 m and lift upto 1.5 m, as directed
by Engineer-in-charge.
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
derived from natural sources : 4 graded stone
aggregate 40 mm nominal size derived from
natural sources)
derived from natural sources : 8 graded stone
aggregate 40 mm nominal size derived from
natural sources)
5.0 REINFORCED CEMENT CONCRETE
5.1S CAST IN SITU
Reinforced cement concrete work in walls (any
thickness), including attached pilasters,
buttresses, plinth and string courses, fillets,
5.2 columns, pillars, piers, abutments, posts and
struts etc. above plinth level up to floor five
level, excluding cost of centering, shuttering,
finishing and reinforcement :
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources)
AMBALA DIVISION-ENGG/NORTHERN RLY
5.3 Reinforced cement concrete work in beams, cum 1 10719.3 10719.3
suspended floors, roofs having slope up to 15
degree landings, balconies, shelves, chajjas,
lintels, bands, plain window sills, staircases
and spiral stair cases above plinth level up to
5 floor five level, excluding the cost of centering,
shuttering, finishing and reinforcement with
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources).
5.9S FORM WORK
Centering and shuttering including strutting,
propping etc. and removal of form for
5.9.3 Suspended floors, roofs, landings, balconies Sqm 28 766.55 21463.4
and access platform
5.9.5 Lintels, beams, plinth beams, girders, Sqm 12 608.35 7300.2
bressumers and cantilevers
5.9.16 Edges of slabs and breaks in floors and walls
5.22S STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete above plinth
5.22A.6 Thermo-Mechanically Treated bars of grade Kg 240 89.65 21516
Fe-500D or more.
6.0 MASONRY WORK
Brick work with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V
level in all shapes and sizes in :
8.0 CLADDING WORK
8.20S STONE WORK DRY CLADDING
8.31 Providing and fixing Ist quality ceramic glazed Sqm 199 1063.45 211626.55
wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of
approved make, in all colours, shades except
burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting,
risers of steps and dados, over 12 mm thick
bed of cement mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white
cement mixed with pigment of matching
shade complete.
9.0 WOOD AND P.V.C. WORK
Providing and fixing 25 mm thick shutters for
cup board etc. :
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I)
decorative type, core of block board
9.20 construction with frame of 1st class hard wood
and well matched teak 3 ply veneering with
vertical grains or cross bands and face
veneers on both faces of shutters.
9.20.1 35 mm thick including ISI marked Stainless Sqm 7 3086.1 21602.7
Steel butt hinges with necessary screws
9.70S STAINLESS STEEL FITTINGS
Providing and fixing IS : 12817 marked
9.70 stainless steel butt hinges with stainless steel
screws etc. complete :
AMBALA DIVISION-ENGG/NORTHERN RLY
ANODISED ALUMINIUM FITTINGS (ALL FITTINGS
SHALL BE ISI MARKED)
Providing and fixing aluminium sliding door
bolts, ISI marked anodised (anodic coating not
9.96 less than grade AC 10 as per IS : 1868),
transparent or dyed to required colour or
shade, with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts, ISI
marked, anodised (anodic coating not less
9.97 than grade AC 10 as per IS : 1868 )
transparent or dyed to required colour or
shade, with necessary screws etc. complete :
9.98 Providing and fixing aluminium pull bolt lock, Each 1 89.9 89.9
ISI marked, anodised (anodic coating not less
than grade AC 10 as per IS : 1868) transparent
or dyed to required colour and shade, with
necessary screws bolts, nut and washers etc.
Providing and fixing aluminium handles, ISI
marked, anodised (anodic coating not less
9.100 than grade AC 10 as per IS : 1868) transparent
or dyed to required colour or shade, with
necessary screws etc. complete :
9.105S GYPSUM BOARD PARTITIONS
9.119 Providing and fixing factory made P.V.C. door Metre 5 408.25 2041.25
frame of size 50x47 mm with awall thickness
of 5 mm, made out of extruded 5mm rigid PVC
foam sheet, mitred at corners and joined with
2 Nos of 150 mm long brackets of 15x15 mm
M.S. square tube, the vertical door frame
18 profiles to be reinforced with 19x19 mm M.S.
square tube of 19 gauge, EPDM rubber gasket
weather seal to be provided through out the
frame. The door frame to be fixed to the wall
using M.S. screws of 65/100 mm size,
complete as per manufacturer's specification
and direction of Engineer- in-Charge.
AMBALA DIVISION-ENGG/NORTHERN RLY
Providing and fixing factory made panel PVC
door shutter consisting of frame made out of
M.S. tubes of 19 gauge thickness and size of
19 mm x 19 mm for styles and 15x15 mm for
top & bottom rails. M.S. frame shall have a
coat of steel primers of approved make and
manufacture. M.S. frame covered with 5 mm
thick heat moulded PVC 'C' channel of size 30
mm thickness, 70 mm width out of which 50
mm shall be flat and 20 mm shall be tapered
in 45 degree angle on both side forming styles
and 5 mm thick, 95 mm wide PVC sheet out of
which 75mm shall be flat and 20 mm shall be
tapered in 45 degree on the inner side to form
top and bottom rail and 115 mm wide PVC
sheet out of which 75 mm shall be flat and 20
mm shall be tapered on both sides to form
lock rail. Top, bottom and lock rails shall be
provided both side of the panel. 10 mm (5 mm
x 2 ) thick, 20 mm wide cross PVC sheet be
provided as gap insert for top rail & bottom
rail, paneling of 5 mm thick both side PVC
sheet to be fitted in the M.S. frame welded/
sealed to the styles & rails with 7 mm (5
mm+2 mm) thick x 15 mm wide PVC sheet
beading on inner side, and joined together
with solvent cement adhesive. An additional 5
mm thick PVC strip of 20 mm width is to be
stuck on the interior side of the 'C' Channel
using PVC solvent adhesive etc. complete as
per direction of Engineer-in-charge,
manufacturer's specification & drawing.
19 9.120.2 30 mm thick pre laminated PVC door shutters Sqm 1.65 2455.1 4050.92
10.0 STEEL WORK
10.2 Structural steel work riveted, bolted or welded Kg 5143 111.95 575758.85
in built up sections, trusses and framed work,
20 including cutting, hoisting, fixing in position
and applying a priming coat of approved steel
primer all complete.
Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position
and applying a priming coat of approved steel
primer, including welding and bolted with
special shaped washers etc. complete.
11.0 FLOORING
11.5 62 mm thick cement concrete flooring with Sqm 295 928.65 273951.75
concrete hardener topping, under layer 50 mm
thick cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20mm
nominal size) and top layer 12mm thick
cement hardener consisting of mix 1:2 (1
22 cement hardener mix : 2 graded stone
aggregate, 6mm nominal size) by volume,
hardening compound mixed @ 2 litre per 50
kg of cement or as per manufacture's
specifications. This includes cost of cement
slurry, but excluding the cost of nosing of
steps etc. complete.
11.26S KOTA STONE FLOORING
Kota stone slab flooring over 20 mm (average)
thick base laid over and jointed with grey
cement slurry mixed with pigment to match
the shade of the slab, including rubbing and
polishing complete with base of cement
mortar 1 : 4 (1 cement : 4 coarse sand) :
AMBALA DIVISION-ENGG/NORTHERN RLY
11.41S VITRIFIED FLOOR TILES
Providing and laying Polished Granite stone
flooring in required design and patterns, in
linear as well as curvilinear portions of the
building all complete as per the architectural
drawings with 18 mm thick stone slab over 20
mm (average) thick base of cement mortar 1:4
(1 cement : 4 coarse sand) laid and jointed
with cement slurry and pointing with white
cement slurry admixed with pigment of
matching shade including rubbing , curing and
polishing etc. all complete as specified and as
directed by the Engineer-in-Charge.
11.56.1 Polished Granite stone slab colour of Black, Sqm 35 3908.8 136808
Cherry/Ruby Red or equivalent
12.0 ROOFING
Providing, fixing and embedding sand cast iron
accessories for rain water pipes in the
12.40 masonry surrounded with 12 mm thick cement
mortar of the same mix, as that of masonry
(lead caulking will be paid for separately):
Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes conforming to IS :
13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap
for thermal expansion, (i) Single socketed
Providing and fixing on wall face unplasticised
- PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.5 Bend 87.5 degrees
12.50 Providing and fixing precoated galvanised iron Sqm 65 671.55 43650.75
profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-
charge) 0.50 mm (+ 0.05 %) total coated
thickness with zinc coating 120 grams per sqm
as per IS: 277, in 240 mpa steel grade, 5-7
microns epoxy primer on both side of the
sheet and polyester top coat 15-18 microns.
Sheet should have protective guard film of 25
27 microns minimum to avoid scratches during
transportation and should be supplied in
single length upto 12 metre or as desired by
Engineer-in-charge. The sheet shall be fixed
using self drilling /self tapping screws of size
(5.5x 55 mm) with EPDM seal, complete upto
any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters
and trusses and including cutting to size and
shape wherever required.
13.0 FINISHING
13.1S CEMENT PLASTER (IN FINE SAND)
13.1 12 mm cement plaster of mix :
13.44S EXTERIOR FINISHING
Finishing walls with Acrylic Smooth exterior
paint of required shade :
29 ltr/10 sqm over and including priming coat of
exterior primer applied @ 2.20 kg/10 sqm)
AMBALA DIVISION-ENGG/NORTHERN RLY
Finishing with Deluxe Multi surface paint
13.48 system for interiors and exteriors using Primer
as per manufacturers specifications :
13.48.1 Two or more coats applied on walls @ 1.25 Sqm 1200 158.95 190740
30 ltr/10 sqm over and including one coat of
Special primer applied @ 0.75 ltr /10 sqm
Painting with synthetic enamel paint of
13.61 approved brand and manufacture to give an
Lettering with black Japan paint of approved letter
brand and manufacture per cm
13.80 Providing and applying white cement based Sqm 250 123.85 30962.5
putty of average thickness 1 mm, of approved
33 brand and manufacturer, over the plastered
wall surface to prepare the surface even and
smooth complete.
14.0 REPAIRS TO BUILDING
14.75AS ROUTINE MAINTENANCE WORK
14.87 Providing and laying in situ five course water Sqm 500 454.8 227400
proofing treatment with APP (Atactic
Polypropylene) modified Polymeric
memberane over roof consisting of first coat
of bitumen primer @ 0.40 litre per sqm, 2nd &
4th courses of bonding material @ 1.20
kg/sqm, which shall consist of blown type
bitumen of grade 85/25 conforming to IS : 702,
3rd layer of roofing membrane APP modified
Polymeric membrane 2.0 mm thick of 3.00 Kg/
sqm weight consisting of five layers
prefabricated with centre core as 100 micron
HMHDPE film sandwiched on both sides with
polymeric mix and the polymeric mix is
protected on both side with 20 micron
HMHDPE film. 5th, the top most layer shall be
finished with brick tiles of class designation 10
grouted with cement mortar 1:3 (1 cement : 3
fine sand) mixed with 2% integral water
proofing compound by weight of cement over
a 12 mm layer of cement mortar 1:3 (1
cement : 3 fine sand) and finished neat (item
of laying brick tiles shall be paid for
15.0 DISMANTLING AND DEMOLISHING
Demolishing cement concrete manually/ by
mechanical means including disposal of
material within 50 metres lead as per direction
of Engineer - in - charge.
15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c cum 6 1239.6 7437.6
equivalent design mix)
Demolishing brick work manually/ by
mechanical means including stacking of
15.7 serviceable material and disposal of
unserviceable material within 50 metres lead
as per direction of Engineer-in-charge.
Dismantling doors, windows and clerestory
windows (steel or wood) shutter including
chowkhats, architrave, holdfasts etc. complete
and stacking within 50 metres lead :
Dismantling tile work in floors and roofs laid in
15.23 cement mortar including stacking material
within 50 metres lead.
AMBALA DIVISION-ENGG/NORTHERN RLY
15.56 Dismantling old plaster or skirting raking out Sqm 250 45.05 11262.5
joints and cleaning the surface for plaster
including disposal of rubbish to the dumping
ground within 50 metres lead.
15.57 Dismantling aluminium/ Gypsum partitions, Sqm 50 46.5 2325
doors, windows, fixed glazing and false ceiling
40 including disposal of unserviceable material
and stacking of serviceable material with in 50
meters lead as directed by Engineer-in-charge.
15.60 Disposal of building rubbish / malba / similar cum 10 219.35 2193.5
unserviceable, dismantled or waste materials
by mechanical means, including loading,
41 transporting, unloading to approved municipal
dumping ground or as approved by Engineer-
in-charge, beyond 50 m initial lead, for all
leads including all lifts involved.
17.0 SANITARY INSTALLATIONS
Providing and fixing white vitreous china
pedestal type water closet (European type
W.C. pan) with seat and lid, 10 litre low level
white P.V.C. flushing cistern, including flush
17.2 pipe, with manually controlled device (handle
lever), conforming to IS : 7231, with all fittings
and fixtures complete, including cutting and
making good the walls and floors wherever
17.2.1 W.C. pan with ISI marked white solid plastic Each 2 5540.55 11081.1
Providing and fixing wash basin with C.I.
brackets, 15 mm C.P. brass pillar taps, 32 mm
17.7 C.P. brass waste of standard pattern, including
painting of fittings and brackets, cutting and
making good the walls wherever require:
17.7.4 White Vitreous China Flat back wash basin size Each 1 1679.6 1679.6
43 550x 400 mm with single 15 mm C.P. brass
17.7A Providing and fixing wash basin with C.I. Each 1 3459.05 3459.05
brackets, 15 mm dia CP Brass single hole
basin mixer of approved quality and make,
including painting of fittings and brackets,
cutting and making good the walls wherever
required:- (a) White Vitreous China Wash basin
size 550x400 mm with a 15 mm CP Brass
single hole basin mixer
17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet Each 1 299.35 299.35
with flexible tube upto 1 metre long with S.S.
45 triangular plate to Eureopean type W.C. of
quality and make as approved by Engineer - in
17.31 Providing and fixing 600x450 mm beveled Each 4 1411.15 5644.6
edge mirror of superior glass (of approved
46 quality) complete with 6 mm thick hard board
ground fixed to wooden cleats with C.P. brass
screws and washers complete.
Providing and fixing PTMT towel rail complete
with brackets fixed to wooden cleats with CP
brass screws with concealed fittings
arrangement of approved quality and colour.
17.73.1 450 mm long towel rail with total length of Each 1 573.6 573.6
47 495 mm, 78 mm wide and effective height of
88 mm, weighing not less than 170 gms
18.0 WATER SUPPLY
18.4S PP-R PIPES
AMBALA DIVISION-ENGG/NORTHERN RLY
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes
confirming to IS 15801, UV stabilized & anti -
microbial fusion welded, having thermal
stability for hot & cold water supply, including
all PP - R plain & brass threaded polypropylene
random fittings, i/c fixing the pipe with clamps
at 1.00 m spacing. This includes testing of
joints complete as per direction of Engineer-in-
Charge. -Internal Exposed on walls
Providing and fixing uplasticised PVC
connection pipe with brass unions :
18.21.2 45 cm length
18.49S C.P. BRASS FITTINGS
Providing and fixing C.P. brass angle valve for
18.53 basin mixer and geyser points of approved
quality conforming to IS:8931
18.54S PTMT FITTINGS
Providing and fixing PTMT bib cock of
approved quality and colour.
not less than 88 gms
18.59S AIR VALVE & WATER METER (BULK TYPE)
18.65 Providing and fixing PTMT soap Dish Holder Each 1 96.75 96.75
having length of 138mm, breadth 102mm,
52 height of 75mm with concealed fitting
arrangements, weighing not less than 106
19.0 DRAINAGE
19.1S STONE WARE PIPES AND FITTINGS
Providing, laying and jointing glazed
stoneware pipes class SP-1 with stiff mixture
19.1 of cement mortar in the proportion of 1:1 (1
cement : 1 fine sand) including testing of joints
etc. complete :
Providing and laying cement concrete 1:5:10
(1 cement : 5 coarse sand : 10 graded stone
19.2 aggregate 40 mm nominal size) all-round S.W.
pipes including bed concrete as per standard
Constructing brick masonry manhole in
cement mortar 1:4 ( 1 cement : 4 coarse sand
) with R.C.C. top slab with 1:1.5:3 mix (1
cement : 1.5 coarse sand (zone-III) : 3 graded
stone aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement : 4
coarse sand (Zone-III) : 8 graded stone
aggregate 40 mm nominal size), inside
plastering 12 mm thick with cement mortar
1:3 (1 cement : 3 coarse sand) finished with
floating coat of neat cement and making
channels in cement concrete 1:2:4 (1 cement :
2 coarse sand : 4 graded stone aggregate 20
mm nominal size) finished with a floating coat
of neat cement complete as per standard
AMBALA DIVISION-ENGG/NORTHERN RLY
Inside size 120x90 cm and 90 cm deep
including C.I. cover with frame (medium duty)
500 mm internal diameter, total weight of
cover and frame to be not less than 116 kg
(weight of cover 58 kg and weight of frame 58
19.7.2.1 With common burnt clay F.P.S. (non modular) Each 2 24405.9 48811.8
bricks of class designation 7.5
Providing and fixing in position pre-cast R.C.C.
19.19 manhole cover and frame of required shape
and approved quality
56 19.19.2.2 Circular shape 500 mm internal diameter Each 2 1056.65 2113.3
21.0 ALUMINIUM WORK
Providing and fixing aluminium work for doors,
windows, ventilators and partitions with
extruded built up standard tubular sections/
appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS:
1285, fixing with dash fasteners of required
dia and size, including necessary filling up the
gaps at junctions, i.e. at top, bottom and sides
with required EPDM rubber/ neoprene gasket
etc. Aluminium sections shall be smooth, rust
free, straight, mitred and jointed mechanically
wherever required including cleat angle,
Aluminium snap beading for glazing /
paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and
the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for
21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness Kg 120 466.3 55956
of powder coating 50 micron)
For shutters of doors, windows & ventilators
including providing and fixing hinges/ pivots
and making provision for fixing of fittings
wherever required including the cost of EPDM
rubber / neoprene gasket required (Fittings
shall be paid for separately)
21.1.2.2 Powder coated aluminium (minimum thickness Kg 140 564.8 79072
of powder coating 50 micron)
Providing and fixing glazing in aluminium door,
window, ventilator shutters and partitions etc.
with EPDM rubber / neoprene gasket etc.
21.3 complete as per the architectural drawings
and the directions of engineer-in-charge .
(Cost of aluminium snap beading shall be paid
in basic item):
21.3.2 With float glass panes of 5 mm thickness Sqm 4 1325.55 5302.2
(weight not less than 12.50 kg/sqm)
21.17 Providing and fixing anodised aluminium grill Kg 15 560.85 8412.75
(anodised transparent or dyed to required
shade according to IS: 1868 with minimum
anodic coating of grade AC 15) of approved
design/pattern, with approved standard
section and fixed to the existing window frame
with C.P. brass/ stainless steel screws @ 200
mm centre to centre, including cutting the grill
to proper opening size for fixing and operation
of handles and fixing approved anodised
aluminium standard section around the
opening, all complete as per requirement and
direction of Engineer-in-charge. (Only weight
of grill to be measured for payment).
22.0 WATER PROOFING
AMBALA DIVISION-ENGG/NORTHERN RLY
22.14 Grading roof for water proofing treatment with
61 sand : 4 graded stone aggregate 20mm
26.0 NEW TECHNOLOGIES AND MATERIALS
Providing and fixing false ceiling at all heights
with integral densified calcium silicate
reinforced with fibre and natural filler false
ceiling tiles of Size 595x595mm of approved
texture, design and patterns,as per CPWD
Specification 2019, to be laid in true horizontal
level suspended on inter-locking metal T-Grid
of hot dipped galvanised iron section of
0.33mm thick (galvanized @ 120 grams per
sqm including both sides) comprising of main-
T runners of size 24x38 mm of length 3000
mm, cross - T of size 24x32 mm of length
1200 mm and secondary intermediate cross-T
of size 24x32 mm of length 600mm to form
grid module of size 600 x 600 mm, suspended
from ceiling using galvanised mild steel items
(galvanizing @ 80 grams per sqm) i.e. 12x50
mm long dash fasteners, 6 mm dia fully
threaded hanger rod upto 1000 mm length
and L-shape level adjuster of size 76
x25x25x1.6 mm fixed with grid and Z cleat of
size 25x37x25x1.6mm thick with precut hole
on both 25mm flange to pierce into 12x50mm
or even bigger size dash fastener if require,
fixed with Galvanised iron perimeter wall
angle of size 24x24x0.40 mm of length 3000
mm to be fixed on periphery wall / partition
with the help of plastic rawl plugs at 450 mm
center to center and 40 mm long dry wall S.S
screws. The work shall be carried out as per
specifications, drawing and as per directions
of the Engineer-in-Charge.
26.22.1 With 15 mm thick tegular edged light weight Sqm 55 1777.5 97762.5
calcium silicate false ceiling tiles.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .