| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-Finance MEGHDOOT HOTTEL MALL ROAD RANIKHET UTTARAKHAND | ₹33.0 L | L1 | Accepted-Finance BEING LOWEST BIDDER |
| 2 | L2₹38.1 L+₹5.1 L (15.5%)Rejected-Finance GANDHI CHOWK SHIV MANDIR MARG RANIKHET DISTT ALMORA UTTARAKHAND | ₹38.1 L+₹5.1 L (15.5%) | L2 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 3 | L3₹39.9 L+₹7.0 L (21.2%)Rejected-Finance 81 82 GHER SAIKH MITHOO KUBRHI PAKHAR ZAKHERA BAREILLY UP | BAREILLY | BAREILLY | UTTAR PRADESH | ₹39.9 L+₹7.0 L (21.2%) | L3 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 4 | L4₹43.8 L+₹10.8 L (32.8%)Rejected-Finance | ₹43.8 L+₹10.8 L (32.8%) | L4 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 5 | L5₹66.8 L+₹33.9 L (102.7%)Rejected-Finance RZ M 21 NAND BLOCK MAHAVIR ENCLAVE PALAM NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹66.8 L+₹33.9 L (102.7%) | L5 | Rejected-Finance NOT BEING LOWEST BIDDER |
| Sl No | Description | Qty | Unit | R N Kharwar and Sons L1 | M/S NAYAL ELECTRICALS L2 | JAI SAI ENGINEERING L5 | shahji contractors L3 | KRISHNA SAI ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and errecting in true vertical position steel tubuler poles 9 meter long complete with M S base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-31 with and including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed | 10 | Each | 14,000 ₹1,40,000 Lowest | 15,690 ₹1,56,900 | 18,000 ₹1,80,000 | 21,000 ₹2,10,000 | 16,000 ₹1,60,000 |
| 2.00 | M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of steel tubular pole incl form work complete all as specified and directed. | 5.1 | Cum | 2,000 ₹10,200 | 2,980 ₹15,198 | 8,790 ₹44,829 | 1,500 ₹7,650 Lowest | 3,500 ₹17,850 |
| 3.00 | M & L for PCC (1: 4:8 ) type D-2 using 40mm graded stone aggregate as in bottom of pit for bed concrete of steel tubular pole incl form work complete all as specified and directed. | 0.54 | Cum | 2,000 ₹1,080 Lowest | 2,780 ₹1,501.2 | 8,765 ₹4,733.1 | 2,500 ₹1,350 | 3,000 ₹1,620 |
| 4.00 | M & L for PCC ( 1:2:4) type B-1 using 20mm graded stone aggregate as in coping including all form work complete all as specified and directed. | 2 | Cum | 3,000 ₹6,000 | 3,780 ₹7,560 | 12,550 ₹25,100 | 2,000 ₹4,000 Lowest | 5,000 ₹10,000 |
| 5.00 | M&L for MS cross arms bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. | 0.25 | Qtl | 10,000 ₹2,500 | 1,02,678 ₹25,669.5 | 17,890 ₹4,472.5 | 15,000 ₹3,750 | 1,500 ₹375 Lowest |
| 6.00 | M & L for stringing, stretching and strengthening of overhead conductor (ACSR) on existing LT steel tubular pole including binding and jointing the conductor with and including 14 SWG binding wire and following sizes ACSR conductors: (a) 6/1 X 2.59 mm aluminium and 1 X 2.59 mm steel (Weasel) (b) 6/1 X 3.00 mm aluminium and 1 X 3.00 mm steel (Ferret) | 2.5 | Qtl | 8,800 ₹22,000 | 13,980 ₹34,950 | 26,340 ₹65,850 | 7,000 ₹17,500 Lowest | 17,000 ₹42,500 |
| 7.00 | S&F shackle type insulator, porcelain, vitreous, white, brown or green insulator of size 75mm height and 90mm dia for working pressure 1100 volts, LT complete with insulator bolts, washers and nuts complete all as specified and directed. | 55 | Each | 150 ₹8,250 | 89 ₹4,895 Lowest | 285 ₹15,675 | 100 ₹5,500 | 100 ₹5,500 |
| 8.00 | S & F stay assembly comprising GI stay bow 400 X 14 mm, GI steel stay rod 1800 mm long X 16 mm dia with nut-bolts, washers, GI steel plate 230 X 230 X 6 mm, two Nos. thimble, loop insulator of size 65 X 90 mm clearance of hole 16 mm, stay wire of GI stay strand of size 7 X 3.15 mm fixed to stay assembly and stay clamps including necessary excavation and earth work in hard / dense soil, PCC 1:3:6 type C-2 block complete all as specified and directed. | 10 | Each | 1,400 ₹14,000 Lowest | 2,150 ₹21,500 | 4,765 ₹47,650 | 2,200 ₹22,000 | 4,500 ₹45,000 |
| 9.00 | M&L for stringing, stretching and strengthening of GI wire 4mm dia on LT electric lines including binding, jointing etc all as specified. | 0.8 | Qtl | 10,000 ₹8,000 | 8,790 ₹7,032 | 10,300 ₹8,240 | 5,000 ₹4,000 | 1,300 ₹1,040 Lowest |
| 10.00 | M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.
Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. | 8 | One Job | 2,900 ₹23,200 Lowest | 3,790 ₹30,320 | 10,032 ₹80,256 | 5,000 ₹40,000 | 7,000 ₹56,000 |
Tender Value
₹44.6 L
EMD Value
₹89,200
Closing Date
6 Aug 2026, 6:00 pmClosed
GE Ranikhet
GE (MES) RANIKHET
REPAIR OF EXTERNAL ELECTRIFICATION (LT WORKS) OF ENTIRE AREA OF RANIKHET UNDER GE RANIKHET
2026_MES_776753_1
GE/RKT/65 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ranikhet
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Ranikhet
₹89,200
Yes
14 Sept 2026
9 Jul 2026
13 Aug 2026
9 Jul 2026
6 Aug 2026
23 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and errecting in true vertical position steel tubuler poles 9 meter long complete with M S base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-31 with and including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed | 10 | Each | - | - |
| 2 | M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of steel tubular pole incl form work complete all as specified and directed. | 5.1 | Cum | - | - |
| 3 | M & L for PCC (1: 4:8 ) type D-2 using 40mm graded stone aggregate as in bottom of pit for bed concrete of steel tubular pole incl form work complete all as specified and directed. | 0.54 | Cum | - | - |
| 4 | M & L for PCC ( 1:2:4) type B-1 using 20mm graded stone aggregate as in coping including all form work complete all as specified and directed. | 2 | Cum | - | - |
| 5 | M&L for MS cross arms bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. | 0.25 | Qtl | - | - |
| 6 | M & L for stringing, stretching and strengthening of overhead conductor (ACSR) on existing LT steel tubular pole including binding and jointing the conductor with and including 14 SWG binding wire and following sizes ACSR conductors: (a) 6/1 X 2.59 mm aluminium and 1 X 2.59 mm steel (Weasel) (b) 6/1 X 3.00 mm aluminium and 1 X 3.00 mm steel (Ferret) | 2.5 | Qtl | - | - |
| 7 | S&F shackle type insulator, porcelain, vitreous, white, brown or green insulator of size 75mm height and 90mm dia for working pressure 1100 volts, LT complete with insulator bolts, washers and nuts complete all as specified and directed. | 55 | Each | - | - |
| 8 | S & F stay assembly comprising GI stay bow 400 X 14 mm, GI steel stay rod 1800 mm long X 16 mm dia with nut-bolts, washers, GI steel plate 230 X 230 X 6 mm, two Nos. thimble, loop insulator of size 65 X 90 mm clearance of hole 16 mm, stay wire of GI stay strand of size 7 X 3.15 mm fixed to stay assembly and stay clamps including necessary excavation and earth work in hard / dense soil, PCC 1:3:6 type C-2 block complete all as specified and directed. | 10 | Each | - | - |
| 9 | M&L for stringing, stretching and strengthening of GI wire 4mm dia on LT electric lines including binding, jointing etc all as specified. | 0.8 | Qtl | - | - |
| 10 | M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.
Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. | 8 | One Job | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
BOQ_869854.xls
BOQ • 0.59 MB
tenderdocu65.pdf
Tender Documents • 2.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .