Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹81,279
Closing Date
29 Oct 2026, 12:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EE MSDED PWD
O/o The Executive Engineer Murshidabad Electrical Division P.W.Dte. 184, C.R.Das Road, Berhampore, Murshidabad, PIN -742101
Replacement of 10 Years Old Air-Conditioning Machine of SNCU and Emergency Ward of Murshidabad Medical College and Hospital (Electrical Work).
2026_WBPWD_5079854_1
WBPWD/EE/MsdED/129/e-Q of 26-27
Open Tender
A/C ORG
Item Rate
20 days
Murshidabad
Please refer Tender documents.
5 documents required · 5 mandatory
₹81,279
13 Oct 2026
13 Oct 2026
31 Oct 2026
13 Oct 2026
29 Oct 2026
15 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC OF AC
Supply and delivery of 1.9/2.0 Ton SPLIT type room air conditioner machine having the following specification:-
(a) Cooling capacity nominal (BTU):24000
(b) Star rating- 5 star.
(c) Rated voltage—230v +/-5%, Frequency-50Hz.
(d) Compressor type-Rotary, Condenser and evaporator- Copper Coil Compressor must be prefilled of refrigerant gas
(e) Refrigerant : R32/R410A
(f) Mini. Room Discharge air flow rate 600CFM.
(g) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option (low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges, the Compressor of the AC machines should be warranted for 5 years.(MAKE: O-GENERAL/ Mitsubishi Heavy/ Mitsubishi Electric) and the Split AC machine should be warranted for 3 years. [Agency shall provide necessary and adequate routine servicing in fortnight basis for all AC machines upto expirity of DLP.] | 38 | Nos. | - | - |
| 2 | Supply & Delivery of ceiling suspended Concealed Split Airconditioners having Microprocessor Based Control System and the following specification Capacity-3 Tonnage Rated Cooling Capacity-36000BTU/Hr No of IDU-1 No Air-flow/IDU-1200 CFM No of ODU-1 No Compressor -1No Scroll Compressor/Rotary Compressor Refrigerent-R 410A/Eco Frendly Refrigerant Condenser & Cooling Coil: Copper Coil Power Supply: 240V/415V, 50Hz,3 Ph AC Make: Blue Star/ Mitsubishi Electric/Hitachi/Diakin. [Agency shall provide necessary and adequate routine servicing in fortnight basis for all AC machines upto expirity of DLP.] | 2 | Nos. | - | - |
| 3 | Installation testing and commissioning of 1.8/2.0 Ton split type AC machine on wall by appropriate mounting kit and testing whole refrigeration system with all joints, valves etc incl leak testing, supply and filling refrigeration gas, making hole in wall, mending good to damages | 38 | Nos. | - | - |
| 4 | Installation testing and commissioning of 3.0 Ton Concealed split type AC machine from ceiling by appropriate mounting kit and testing whole refrigeration system with all joints, valves etc incl leak testing, supply and filling refrigeration gas, making hole in wall, mending good to damages | 2 | Nos. | - | - |
| 5Supply and installation of Copper refrigeration pipe of suitable diameter, insulation of pipe by nitrile rubber tube Insulation on suction/liquid line copper pipe of split AC, tape joiting material, connecting IDU and ODU by 3/4 core 2.5MM Copper Wire for 1.9/2.0 Ton split AC machines as par direction of EIC | |||||
| 5.01 | 5/8" & 1/4" copper pipe. | 350 | mtr. | - | - |
| 6Supply and installation of Copper refrigeration pipe of suitable diameter, insulation of pipe by black kenefoam, tape joiting material, connecting IDU and ODU by 3/4 core 2.5MM Copper Wire for 3.0 Ton split AC machines as par direction of EIC | |||||
| 6.01 | 3/4" & 3/8" copper pipe. | 20 | mtr. | - | - |
| 7 | Supply & laying Drain Water piping work out of UPVC hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors - 20 mm dia | 200 | mtr. | - | - |
| 8 | Supplying and fixing 40A FP 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand/Schnider/Crabtree) | 2 | Nos. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.36 MB
Tendernotice_2.pdf
PDF • 0.55 MB
BOQ_5184785.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .