Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC AYITHARA AYITHARA MAMBARAM KANNUR | KANNUR | KANNUR | KERALA | L1 | Accepted-AOC AGREEMENT EXECUTED BETWEEN CONTRACTOR AND PANOOR MUNICIPALITY ENGINEERING WING |
Tender Value
₹4.7 L
EMD Value
₹11,650
Closing Date
3 Apr 2025, 3:00 pmClosed
Assistant Engineer
Office of the Assistant Engineer,Panoor
Compound wall construction
2025_LSGD_747006_1
KSWMP/PNR/1378/529/2024-25/RET
Open Tender
Civil Works - Buildings
Item Rate
180 days
Panoor Municipality
Please refer Tender documents.
14 documents required · 14 mandatory
₹1,030
₹11,650
Panoor
28 Jun 2025
10 Mar 2025
3 Apr 2025
10 Mar 2025
3 Apr 2025
10 Mar 2025
13 Mar 2025
Amount
MCF COMPOUNDWALL CONSTRUCTION
15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.10.2:Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually / by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge:In cement mortar
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
OD384889/2023-2024:Laterate masonry with neatly dressed laterate stone of size 35x20x20cmor nearest size in cement mortar 1:6 for superstructure above floor two level upto floor five level including all cost of materials, labour charges etc.
OD374853/2023-2024:PVC WEEP HOLES- Providing weep holes using 110 mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.82.2:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
16.70.1:Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm
OD293549/2023-2024:Providing and fixing of scaffolding net made of high density polethylene UV stabilized having density 100gm/ sqm . The frame shall be of 50 mm GI pipe (M) and the net and GI pipe should be binded with 2 mm. G.I. Wire in two places in each GI pipe complete and as per direction of Engineer-in-charge.
OD293556/2023-2024:O/D: Dust suppression by water sprinkling through water tanker having capacity of 5000 litre and sprinkler with one labour including the cost of water, filling of tanker, sprinkler work at site with all leads and lifts as per the direction of Engineer in charge.
OD293555/2023-2024:OD: Providing sufficient and appropriate slings, chanins clamps rated for the wieght as to secure uneven loads to prevent sliding during lifting/lowering loads
OD293554/2023-2024:OD: Providing Oil drum/lubricants/Paint drum without spill containment including spill tray for handling oil or the lubricant.
OD293553/2023-2024:Safe disposal of used water - Construction of soak pit to a size of 1.0 1.0x. 1.0 m by excavating earth and filling with brick bat inside.
OD293551/2023-2024:O/D: Providing and fixing information boards or obligatory sign boards with project details, contact informations of executing authority, nearest hospitals, police stations etc.The board of size 1.2m x 0.6m made of 50x50x3mm hollow MS tube posts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The overall height of the board shall be 2.50m from the groundlevel. The item includes cost of fabrication, painting, lettering, finishing, erection, erthwork, cement concrete 1:2:4, structural steel leg, its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to executed the job etc. complete, as per the directon of Engineer in charge.
OD293552/2023-2024:OD: Public inconvenience control (Traffic access) - Providing security guard as and when required.
Bidder Name
Biju T
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1206577.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .