Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹8.2 L+₹44,776 (5.80%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹8.6 L+₹88,255 (11.4%)Rejected-Finance 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹8.7 L+₹93,070 (12.1%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹8.7 L+₹96,075 (12.4%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
26 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR MAINT OF INTERNAL ELECTRIFICATIONS HANGAR LIGHTS AND ITS CONNECTED ITEMS FOR TECHNICAL AREA AT RALAWAS UNDER GE BANAR
2023_MES_606085_1
8823/16/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
PLEASE REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹24,000
Yes
18 Aug 2023
27 Jun 2023
28 Jul 2023
27 Jun 2023
26 Jul 2023
12 Jul 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, sockets, lamp holder and conduit etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified . Note:- The damaged surfaces to be made good with plastering & applying colour wash in required coats to matching with existing surfaces as directed by Engineer-in-charge. Cost of the same deem to be included in quoted rates and nothing extra on this account admissible.
M&L Point wiring with 1.5 Sq. mm PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with Multi-stranded copper conductor in and including PVC casing caping (heavy grade) and accessories fixed on walls/floors/ceilings etc alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLS cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one light point/fan point controlled by one switch, complete all as specified .
All as per item No 2.00 above but for One socket outlet, 3 pin, 5 Amp, 230 volt flush type on same board.
All as per item No 2.00 above but for One switch socket outlet, 3 pin, 5 Amp, 230 volt flush type on independent board.
All as per item No 2.00 above but for One bell/buzzar point controlled by one bell push independent.
All as per item No.2.00 herein before but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified.
M&L for point wiring with two single core 1.5 Sq.mm size multistranded FRLS copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including rigid PVC CONDUIT and conduit accessories,confirming to IS specifications,concealed in wall fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , complete all as specified for :- One light / fan point controlled by one, one-way switch, SP, 6 Amps.
One socket outlet, 3 pin, 5 Amp, 230 volt flush type on same board.
One switch socket outlet, 3 pin, 5 Amp, 230 volt flush type on independent board.
One bell/buzzar point controlled by one bell push independent.
Ditto all as per item No.4 herein before but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified.
Supply and fix switch piano, flush type, single pole, one way, 5 Amps 230 Volts complete all as specified.
Supply and fix in repair switch piano, flush type, single pole, one way, 5 Amps 230 Volts complete all as specified.
Supply and fix in repair switch piano, flush type, single pole, one way 15 Amps 230 Volts complete all as specified.
Supply and fix socket outlet 2-in-1, 3 pin, 6 Amps, flush type with shutter, complete all as specified.
Supply and fix in repair socket outlet 2-in-1, 3 pin, 5 Amps, flush type with shutter, complete all as specified.
Supply and fix in repair of socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type with shutters, complete all as specified.
Supply and fix switch socket combination 2-in-1, 3 pin, 5 Amps, flush type with shutter, complete all as specified.
Supply and fix in repair switch socket combination 2-in-1, 3 pin, 5 Amps, flush type with shutter, complete all as specified.
Supply and fix switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type with shutters, complete all as specified.
Supply and fix in repair switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type with shutters, complete all as specified.
Supply and fix electronic regulator, 100W, 250V flush type on the exiting phenolic laminated sheet etc. complete all as specified.
Supply and fix in repair electronic regulator, 100W, 250V flush type on the exiting phenolic laminated sheet etc complete all as specified.
Supply and fix ceiling rose, surface bakelite, three terminals complete all as specified.
Supply and fix in repair of ceiling rose, surface bakelite, three terminals complete all as specified.
Supply and fix Lamp Holder PVC/polycarbonate type with back plate ISI Marked for fixing bulbs complete all as specified for batten fitting.
Supply and fix in repair Lamp Holder PVC/polycarbonate type with back plate ISI Marked for fixing bulbs complete all as specified for batten fitting
Supply and fix in repair Pin Top 15 Amp complete all as specified.
Supply and fix buzzer, ding dong AC 230 Volt, Single pole complete all as specified.
Supply and fix in repair Bell multi Musical type AC 230 Volt, Single pole complete all as specified.
Supply and fix in repair Bell push, AC 230 Volt, Single pole complete all as specified.
Supply and fix in repairs SPN DB's 12 way, 240 V, double door100 Amps rated bus bar, complete all as specified for following:-
All as per item No 19.00 above but 8 way
All as per item No 19.00 above but 4 way
Supply and fix in repair 4 way TPN DB, 415 V, double door 200 amps rated bus bar, including making good disturbed surfaces of walls including plaster cutting of wall etc.complete all as specified.
Supply and fix in repair 4 way VTPN DB, 415 V, double door 200 amps rated bus bar, including 100 Amps 4 pole, 16 KA MCCB, making good disturbed surfaces of walls including plaster cutting of wall etc.complete all as specified .
Supply and fix MCB SPN 32 Amps 240 volts complete all as specified.
Supply and fix in repair MCCB 4 Pole 125 Amps 415 volts. 18kA Adjustable overload setting l &fixed magnetic setting complete all as specified.
Supply and fix MCB SP 6 Amps to 32 Amps 230 Volt complete all as specified.
Supply and fix in repair MCB SP 6 Amps to 32 Amps 230 volt complete all as specified.
M&L in replacement Sub main wiring with single core FRLS PVC insulated and unsheathed multistranded, FRLS copper conductor cable 1100 volts grade drawn through and incl 20 mm size of of PVC conduit accessories and fittings on wall. Cable required for connection to DBs shall deemed to be including and shall not be measured separately. Earth wire shall run inside the conduit. 02 runs 6 sqmm conductor cable and 01 run of 6 sqmm as earth continuity conductor.
All as per item No 25 here-in 02 runs 4 sqmm conductor cable and 01 run of 4 sqmm as earth continuity conductor.
All as per item No 25 here-in 02 runs 2.5 sqmm conductor cable and 01 run of 2.5 sqmm as earth continuity conductor.
Supply and fix in repair Modular metal flush box with white cover plate with frame of 03 Module, for mounting, switches, sockets, fan regulator, etc. 3 modul Note:- (i) Switches, sockets, fan regulator, etc. will be measured and paid seperately under relevent items.
All as per Ser item No 26.00 but 6 module
All as per Ser item No 26.00 but 8 module cover only
All as per Ser item No 26.00 but 12 module
Supply and fix in repair switch modular 5/6 Amp single pole, one way 1 module complete all as specified.
Supply and fix in repair switch modular 15/16 Amp single pole, one way 1 module complete all as specified.
Supply and fix in repair Bell push modular 6 Amp single pole, one way 1 module complete all as specified.
Supply and fix in repair Fan Regulator modular 120W single pole, one way 2 module complete all as specified.
Supply and fix in repair Socket modular 5/6 Amp single pole, 2/3 pin 2 module complete all as specified.
Supply and fix in repair Socket modular 6/16 Amp single pole, 2/3 pin 2 module complete all as specified.
Supply and fix in repair Switch socket outlet modular multipurpose 3 Pin 16 Amp and one pin 6 Amp controlled by one switch complete all as specified.
Supply and fix in repair Switch socket outlet modular multipurpose 3 Pin 6 Amp flush type controlled by one switch complete all as specified.
S&F in repair 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded complete all as specified.
S&F in repairs Metal Clad Plug and socket with box 20 Amp with MCB single pole complete fixed properly on wall surface with the provisioning of suitable sizes of bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 4 Sqmm as per specification complete all as specified.
Re-routing of existing sub main wiring any size with new 40 mm Steel conduit and prepare the existing surface in good condition complete all as specified.
Re-routing of existing sub main wiring any size with new 32 mm Steel conduit and prepare the existing surface in good condition complete all as specified.
Re-routing of existing sub main wiring any size with new 20 mm PVC cassing capping and prepare the existing surface in good condition complete all as specified.
Re-routing of existing sub main wiring any size with new 25 mm PVC cassing capping and prepare the existing surface in good condition complete all as specified.
Supply and fixing in repair PVC casing capping 20 mm size for existing sub main wiring/point wiring any size and prepare the existing surface in good condition complete all as specified.
Supply and fixing in repair PVC cassing capping 25 mm size for existing sub main wiring/point wiring any size and prepare the existing surface in good condition complete all as specified.
Supply and fixing in repair PVC Ceiling rose back plate surface mounted round type with screw complete all as specified.
Supply and fixing in repair Metal plug and socket boths 20A 3 phase 3 pin as per IS 8804 suitable for existing metal clad box as per specification complete all as specified.
Supply and fixing in repair PVC flexible pipe 20 mm size on existing sub main wiring/point wiring/ any place and prepare the existing surface in good condition complete all as specified.
Supply and fixing in repair PVC Conduit pipe 25 mm size on existing sub main wiring/point wiring/ any place and prepare the existing surface in good condition complete all as specified.
Supply and fix in replacement LED Decorative wall light fixture with 9W retrofit LED lamp champagne gold finish fixture with plastic body type wall mounted 230 V complete with all accessories including 9 w Lamp internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as specified.
M&L Cutting chasing in bricks/walls or concrete surfaces for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified.
M&L for replacement PVC rectangular block for mounting switches,sockets,fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mmx100mmx50mm deep complete all as specified.
M&L for replacement PVC rectangular block for mounting switches,sockets,fan regulator etc with 3 mm thick plastic laminated sheet cover of size 175mmx100mmx50mm deep complete all as specified.
M&L for replacement PVC rectangular block for mounting switches,sockets,fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250mmx200mmx50mm deep complete all as specified.
Supply and fix in repair PVC Junction box with cover 25mm as per site requirement complete all as specified.
Supply and fix for replacement of LED recessed square type down light fiiting 10W, 230V 50hz (1x1 feet) ultra sleek low height false ceilingin square shape luminaire with high power LED long life aesthetically designed with symmetrical light distribution with IP-65 230 V complete with driver all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as specified complete.
Supply and fix replacement of LED recessed Round type down light fiiting 15W, 230V 50hz ultra sleek low height false ceilingin round shape luminaire with high power LED long life aesthetically designed with symmetrical light distribution with IP-65 230 V complete with driver all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as specified.
Supply and fix in repair PVC TV Socket 5 Amps 230 Volts complete all as specified.
S&F in repair PVC insulated copper conductor multistrandred FRLS 2 core 10 sqmm for 1100V conforming to IS-694:2010 complete all as specified.
Supply,fixing and testing in repair of LED 9/12W driver with surge protection complete connection to LED light fitting with suitable wire complete all as specified.
Supply,fixing and testing in repair of LED 15/18W driver with surge protection complete connection to LED light fitting with suitable wire complete all as specified.
S&F in replacement of surface mounting batten tube light fitting, integrated polycarbonate LED channel with white acrylic cover complete suitable for and including lamp LED 1x20 Watt, fixed properly on wall surface and connecting complete from ceilling rose to fitting by three core copper conductor cable of overall sheathed which shall be passed through PVC flexible conduit complete all as specified.
S&F in replacement of surface mounting batten tube light fitting, integrated polycarbonate LED channel with white acrylic cover complete suitable for and including lamp LED 1x10 Watt, fixed properly on wall surface and connecting complete from ceilling rose to fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit complete all as specified.
S&F in replacement of building security light LED fitting 35/45 watt 230V AC outdoor type with high pressure die cast housing and heat resistant complete with driver, epoxy powder coated dark graphite grey colour finish and prismatic polycarbonate cover with individual LED lences suitable for including lamp LED 35 watt,IP-65/66 fixed / connect properly at directed location on building complete all as specified.
M & L for building earthing in repairs complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron wire 4mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in hard/dence soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 complete all as specified.
S&F in repair single core FRLSH PVC insulated copper cable of size 2.5 Sqmm multi stranded 1100V conforming IS-694:2010 complete all as specified.
S&F in repair of Plastic laminated sheet 3mm thick fixed with screws complete as specification complete all as specified.
vinayandsons
new india engineers
Tirupati electricals works and services
Kusum Traders
M/s JOG SINGH MATERIALS
Narender Constrution Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .