| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.8 CrAccepted-AOC | ₹13.8 Cr Quoted ₹13.9 Cr | 1 | Accepted-AOC Accepted since L1 |
| 2 | 2₹15.8 CrRejected-Finance | ₹15.8 Cr | 2 | Rejected-Finance Rejected since not L1 |
| 3 | 3₹16.0 CrRejected-Finance | ₹16.0 Cr | 3 | Rejected-Finance Rejected since not L1 |
| 4 | 4₹16.1 CrRejected-Finance | ₹16.1 Cr | 4 | Rejected-Finance Rejected since not L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical NOT MEETING PQC CRITERIA |
Tender Value
₹16.7 Cr
EMD Value
₹11.6 L
Closing Date
20 Jul 2020, 6:00 pmClosed
DDG CE
DGNP V NAVAL BASE POST PIPE LINE JN VISAKHAPATNAM
SETTING UP OF REFERENCE CUM REPAIR FACILITY IMPS IAC IPMS SHAKTI PLC PCB AT MCD ND V
2020_MES_352020_1
CA No DDG CE V TOKEN 26 OF 2018 2019
Open Tender
Civil Works
540 days
VISAKHAPATNAM
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,000
Yes
₹11.6 L
Yes
DDG CE CONFERENCE HALL
19 Oct 2020
11 Jun 2020
22 Jul 2020
11 Jun 2020
20 Jul 2020
3 Jul 2020
11 Jun 2020 - 19 Jun 2020
22 Jun 2020
Amount
SCHEDULE "A" PART - I [CIVIL WORKS]
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nanital or similar pattern roof/wall coverings including ridges complete all as specified and as directed.
Dismantling asbestos cement plain, corrugated or semi corrugated sheets in roof/wall coverings including ridges etc., complete all as specified and as directed.
Dismantling posts or struts (wood, steel or RCC) any section including taking out embedded portion in concrete and making good distrubed ground etc complete all as specified and as directed.
Removing demolished building materials/ debris etc (other than spoil obtained from earth work) to a distance exc 10.0km and n.exc 15.0km beyond the lead included in the rates including loading and unloading and depositing outside the MD land at GVMC designated places complete all as specified and as directed. Note: Definition of load shall be as per section 21 of SSR Part-I.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for reinforcement cut as required to facilitated demolition complete all as specified and directed.
Dismantling structural steel work including doors,gates angle iron,gusset plate but excluding framed truss etc complete all as specified and as directed.
Cutting and felling of tree exc. 30 cm and not exc. 100 cm girth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to outside MD land and clearing site complete all as specified and as directed.
Grubbing up tree trunk of girth exc. 30 cm and not exc. 100 cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground and stacking of serviceable material and disposal of unserviceable material to outside MD land and clearing site complete all as specified and as directed.
Use and waste of timbering (Whole of the timbering to a face Exc. 3 m & n exc. 5 m deep) as planking and strutting for excavations in trenches in soil, including wales, struts, open poling boards, etc. as may be necessary and fixing and removal complete all as specified and as directed.
Cutting and felling of tree exc. 100 cm and not exc. 150 cm girth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to outside MD land and clearing site complete all as specified and as directed.
Grubbing up tree trunk of girth exc. 100 cm and not exc. 150 cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground and stacking of serviceable material and disposal of unserviceable material to outside MD land and clearing site complete all as specified and as directed.
Cutting and felling of tree exc. 300 cm and not exc. 500 cm girth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to outside MD land and clearing site complete all as specified and as directed.
Grubbing up tree trunk of girth exc. 300 cm and not exc. 500 cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground and stacking of serviceable material and disposal of unserviceable material to outside MD land and clearing site complete all as specified and as directed.
Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches n. exc. 1.5m wide and n. exc.1.5m in depth for foundations, pile cap, beams, shafts, wells, manholes, pier holes, laying of under ground cables or pipe etc., n exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches n. exc. 1.5m wide and n. exc.1.5m in depth for foundations, pile cap, beams, shafts, wells, manholes, pier holes, laying of under ground cables or pipe etc., n exc 10 sq m on plan and getting out in hard/dense soil complete all as specified and as directed.
Excavation over areas in soft/loose soil, n.exc 1.5 mtr deep and geting out complete all as specified and as directed.
Excavation over areas exc. 1.5m and n.exc 3.0m deep for foundations, beams, Pile caps and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in including, spreading, leveling, watering and well ramming in layers n. exc. 25cm thick in soils complete all as specified and as directed.
Material & labour for drilling or boring for 700mm nominal dia. bored cast-in-situ piles, through any or all types of strata i.e soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials to a distance exc 10 Km but not exc 15 Km and depositing where directed at a level not exc 1.5 mtr above the starting point at a designated place as approved by GVMC complete all as specified and as directed.
All as per Item No.1.022 here-in-before but 600mm nominal dia bored cast-in-situ piles complete.
All as per Item No.1.022 here-in-before but through hard rock for founding depth of 2D (D dia of pile) for 700mm nominal dia piles complete.
All as per Item No.1.022 here-in-before but through hard rock for founding depth of 2D (D dia of pile) for 600mm nominal dia piles complete.
M&L for Anti termite treating the back fill in contact with plinth beam at the rate of 7.5 litres of emulsion per square metre of surface area with approved chemical and complete all as specified and as directed.
M&L for Anti termite treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface with approved chemical and complete all as specified and as directed.
M&L for Anti termite treating the soil along with external perimeter of the building at the rate of 2.25 litres of emulsion per metre of the perimeter of building with approved chemical and complete all as specified and as directed. Note for 1.026 to 1.028 Only approved chemical shall be used as per IS 6313 (Part-2): 2013 and applicators of ATT are registered by the Pest Control Association of India (PCAI)/ Indian Pest Control Assoiation (IPCA)
Carrying out initial load tests on test piles as per standard procedure laid down in IS-2911 by static load test method including compressive strength including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. as specified and directed by GE and submission of reports for a test load of 600 tonne in non-working areas in the vicinity, including the cost of new piles for 700mm dia with specification as same as working pile with minimum depth of socketing into the hard rock to a depth of 1.5m etc all as specified and as directed.
All as per Item No.1.029 here-in-before but 600mm nominal dia for a load test of 483 tonne complete.
Carrying out routine load test (working pile) as per standard procedure given in IS-2911 (Part IV) 1985 by static test method for 700mm dia. Piles for a test load of 360 tonne complete all as specified and as directed.
All as per Item No.1.031 here-in-before but 600mm nominal dia for a test load of 290 tone complete.
Removal of excavated material (soil) to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed..
Removal of excavated material to a distance exc. 10.0 Km but n. exc. 15.0 Km and depositing where directed complete all as specified and as directed. Notes:- (i) Tenderer shall obtain sanction from GVMC for designated places before quoting the tender. If designated place may be varied during execution, no claim shall be entertained on this account. (ii) Approval if any to be obtained from GVMC for dumping the excavated material at GVMC designated places, the same shall be obtained by the contractor. Nothing extra shall be paid on this ground.
M&L for Sand filling in floors or pavings or in foundations laid in layers n.exc. 15cm thick spread, leveled and rammed including watering complete all as specified and as directed.
M&L for moorum/red bajri filling under floors or pavings or in foundations, brought from outside MD land laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M&L for hardcore of gauge n. exc. 63 mm, deposited, spread and leveled in layers n. exc. 15cm thick, watered and rammed to a true surface using broken granite stone complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded Granite stone aggregate) as in foundation, filling, mass concrete and underneath pile caps, suspended flooring/slab, beams, plinth protection, surface channels, drains etc. complete all as specified and as directed.
M&L for Providing, cement concrete (1:3:6) type C1 (20mm graded granite stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs, surface channel benching/ haunching and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by.
M&L for Providing, cement concrete (1:2:4) type B0 (12.5mm graded granite stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs, surface channel benching/ haunching and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
Material and labour for providing precast cement concrete (RCC) 1:2:4 type B1 (20mm graded granite stone aggregate) in cover slabs for manholes/drains, chullah hoods, chajjas, water troughs, mangers, shelves, baffle wall and similar articles set in CM 1:4 with plain fair faces, including necessary formwork etc., complete all as specified and as directed. Note: Reinforcement shall be measured and paid separately under respective item of schedule 'A'
M&L for PCC 1:4:8 type D2 (using 40mm graded Granite stone aggregate) surface channel and drainage complete all as specified and as directed.
M & L for PCC (1:3:6) type C-2 using 40mm graded granite stone aggregate as in foundation, filling, mass concrete complete all as sepcified and as directed.
M&L for PCC 1:2:4 type B2 (using 40mm graded Granite stone aggregate) all in surface channel and drains complete all as specified and as directed.
M&L for walling of random/polygon rubble, coursed, well bonded bedded and solidly hearted built in CM 1:4 complete all as specified and as directed.
M&L for extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses Hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc. 20mm granite or trap stone complete all as specified and as directed.
M&L PCC M-40 ( Using 20mm graded granite stone aggregate) as in ramp using ready mix concrete complete all as specified and as direted. Notes :- (i) Minimum cement content shall be 360 Kg/Cu.m. of concrete for M-40 using Portland slag cement with minimum slag content of 50% (fifty percent) for items covered (ii) Design mix shall be as per IS-456-2000. Maximum size of aggregate shall not exceed 20 mm and slump shall be 50mm to 100mm and maximum water cement ratio 0.4. (iii) Unit rate shall be deemed to include for interalia for preliminary design mix and works test cubes. (iv) In case at the time of mix design cement content is increased beyond minimum content given above, no extra payment will be made.
M&L for reinforced cement concrete of grade M-40 (Design mix using 20mm graded granite stone aggregate) using ready mix concrete including supply and mixing of admixtures, as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, pile caps, suspended floor beams & slabs, plinth protection, basement slabs, under-reamed piles etc. using Portland slag cement and handling, conveyance, errection with alignment in true position complete all as specified and as directed.
All as per item No.1.049 here-in-before but slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, duct slab and in shelves and the like complete.
All as per item No.1.049 here-in-before but as in columns, Pillars, piers, vertical bands, posts and struts etc complete.
All as per item No.1.049 here-in-before but as in floor beams, roof beams, cantilevers, bressumers, middle beams, lintels over 1.5m span and lintel bands etc complete.
All as per item No.1.049 here-in-before but as in stairs complete.
All as per item No. 1.049 here-in-before but fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, wall and the like complete.
All as per item No. 1.049 here-in-before but in chajjas and similar works complete.
All as per item No. 1.049 here-in-before but wall retaining wall, basement wall,ballast wall any thickness, above top of footing including attached pilasters and buttresses complete.
Notes for item Nos. 1.049 to 1.056: (i) Minimum cement content shall be 400 Kg/Cu.m. of concrete for pile caps, suspended floor beams, slabs and footings, platform (Covered under item No. 1.049) and cement content shall be 360 Kg/Cu.m. of concrete for M-40 using Portland slag cement with minimum slag content of 50% (fifty percent) for items covered under item Nos. 1.050 to 1.056. (ii) Design mix shall be as per IS-456-2000. Maximum size of aggregate shall not exceed 20 mm and slump shall be 50mm to 100mm and maximum water cement ratio 0.4. (iii) Unit rate shall be deemed to include for interalia for preliminary design mix and works test cubes. (iv) Reinforcement shall be measured and paid for separately. (v) In case at the time of mix design cement content is increased beyond minimum content given above, no extra payment will be made. (vi) Standard manufactured cover blocks should be used.
Chipping of laitance concrete in piles above cut off level upto a maximum of 1m from cut of level and disposal to distance of exc. 10.0Km but n. exc. 15Km and depositing where directed.
M&L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler for 100 mm thick for 100mm thick plinth protection and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and as directed.
M&L for brick work using fly ash bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work using fly ash bricks, straight or curved on plan to any radius in half brick thick walls including provision of 2 Nos 8mm dia CRS bars in every fourth course built in cement mortar 1:4 complete all as specified and as directed.
M&L for Use and waste steel formwork to sides of concrete foundations, pile caps, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and as directed.
M&L for Use and waste steel formwork to sides, faces of vertical walls, water tanks, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. vertical or to batter and the like for fair finished surfaces of concrete complete all as specified and as directed.
All as per item No.1.062 here-in-before but to soffits of suspended slabs such as roof slabs, floor slabs, waist slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) complete.
All as per item No.1.062 here-in-before but to sides and soffits of floor or roof beams, beam haunchings, girders, cantilevers, bressumers, lintel beams, shelves, RCC bands, girders etc complete all as specified and as directed.
All as per item No.1.062 here-in-before but to stair cases with slopping or stepped soffits including risers and stingers (excluding landing) flat etc complete all as specified and as directed.
All as per item No.1.062 here-in-before but to sides of pillars, posts, struts, columns (square,rectangular,polygonal or 'L' shaped) for fair finished and the like complete all as specified and as directed.
All as per item No.1.062 here-in-before but to sides and soffits of chajjas including supports overhangs etc. and splays between floor and beam, chullah hoods, RCC gutter, catwalks, through etc for rough finished surfaces complete.
M&L for Use and waste steel form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floors and roofs etc. exc. 10cm but n. exc. 20cm wide for rough finished surfaces of concrete complete all as specified and as directed.
M&L steel form work non removable ms plates Fe 410-W (grade E-250 ) quality A including ms pipes props left under as in box type slab of main entrance and stair case portion
S&F 150mm long aluminium, anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed.
S&F 16mm dia 300 mm long aluminium alloy, anodised sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section and fixed complete all as specified and as directed.
S&F anodised aluminium door floor stopper 140 mm long complete all as specified and as directed.
S&F 125mm size butt hinges, extruded aluminium alloy with galvanised mild steel pin, anodized and fixed, type B-21 complete all as specified and as directed.
S&f 125mm extruded brass handles fabricated type polished complete all as specified and as directed.
S&F for 150mm long Extruded aluminium alloy handles, cast type, anodised complete all as specified and as directed.
S&F Door closer hydraulically regulated, Aluminium (die cast body) designation No.1, universal type, suitable for door shutters upto 700 mm in width and of weight not more than 35 kg and fixed complete all as specified and as directed.
S&F Door closer hydraulically regulated, Aluminium (die cast body) designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
S&F brass mortice locks, vertical type 100mm size 4 levers complete all as specified and as directed.
S&F floor door stopper with rubber shoe 150mm long of brass body and tongue, anodised, with hard drawn steel spring, fixed complete all as specified and as directed.
M&L for reinforcement in any situation using Corrosion resistant TMT steel bars of grade Fe-500D, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia. or securing with clips complete all as specified and as directed.
All as per item No. 1.081 here-in-before 6mm dia and upto 8mm dia bars complete.
All as per item No. 1.081 here-in-before but 5mm dia. and over upto and including 10mm dia. as in stirrups, spacers and binders complete.
M&L mild steel bars 10mm dia and over,Fe-410-W (Gde.E-250) quality-A cut to length, bent to shape required, complete all as specified and as directed.
M&L for providing and installing MS liner for bored cast-in-situ concrete piles with necessary stiffeners , driving shoe with continuous welding including cutting, bending welding etc. confirming to Gde E-250 Quality B including applying one coat of primer with two coats of EPOXY based anticorrosive treatment as per the manufacturer's instruction complete all as specified and as directed. Notes:- (i) Rate shall be inclusive of cutting the liner at cut off level. The rate is deemed to include for cutting, removal and salvage value of the material so obtained. (ii) MS liner shall be driven upto refusal level/rock touch level, the occurrence of refusal level will be decided by GE at site based on visual inspection of bailer samples from pile bore hole, past experience and laboratory test result. The decision of GE in this regard will be final and binding. (iii) MS liner will be measured and paid up to the cut off level only of pile. Additional MS liner if used for convenience of construction shall be included in the rates quoted. Nothing extra shall be paid separately on this account.
S&F factory made solid PVC door frame of size 50 mm x47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supply and fix in openings as per specification and drawing complete all as specified and as directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face complete all as specified and as directed.
M&L for 12mm thick toughened glass in door shutter including necessary fixtures and fittings for SS patches, locks complete all as specified and as directed.
S&F figured glass 3mm thick, pinhead type of approved brand and shade fixed in position with and including PVC/Neoprene gasket for glazing, glazing clips in ventilators in squares n. exc. 0.5 sq. m each pane complete all as specified and as directed.
M&L for structural glazing with reflective glass 6mm thick aluminium transom bar,bolt nuts and washers, silicon adhessive 3mm seal with double layer face etc complete all as specified and as directed
S&F powder coated aluminium sliding/side hung type window/ ventilator shutters without sash bars, section weighing not less than 0.55 Kg/RM with extruded built up standard tubular and other sections of approved make according to IS (thickness of powder coating not less than 50 micron) including necessary glazing clips weighing not less than 0.124 Kg/RM, for fixing sheet glass anodised aluminium fitting/fixture such as required number of rollers of suitable size, interlocking cleats/plates etc as required for fixing window shutters as per architectural drawings complete all as specified and as directed. Note:- Only aluminium shutter for the windows/ ventilators shall be measured in sqm. Sheet glass and hard ware items such as butt hinges, tower bolts, handles etc, shall be measured and paid separately under relevant items
S&F aluminium powder coated decorative grill for doors, windows and ventilator with one or more rebates including jointing cleats/beading 'U' or 'H' channel for fixing etc. complete all as specified and as directed.
S&F Angle iron, channel or tee sections, flat iron of Fe-410-W (Gde-E-250) quality B fixed complete all as specified and as directed.
M&L for Mild steel plates plain or chequered of any thickness cut to size, rolled to required shape as in cable duct cover etc., and placed in postion including welding attachment confirming to (Fe-410-W) Gde E-250 Quality B complete all as specified and as directed.
M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of grade Fe 410-W (Gde E-250) quality B complete all as specified and as directed.
S&F Plain aluminium sheeting thick 0.56 mm thick alloy 31004H4 in ridges hips, valely gutter ,drip and straight flashing (length 15.00mtr and 150mm width) complete all as specified and as directed.
M&L 46 mm thick Fire retardent door (FRD) of size 2.1x1.2m r with frame and shutte including all necesary hardwares in staircase all as per manufacturer specifications complete all as specified and as directed.
Supply and fix suspended false ceiling of gypsum board of 12.5mm thick conforming to IS with GI perimeter channel of size 20 x 30 x 27 x 0.9mm (having one flange of 20mm and another flange of 30mm and web 27mm) along perimeter of ceiling, screwed fixed to wall with help of nylon sleeves and screws of 610mm centre to centre suspending GI infemedia tech channels of size 15 x 45 x 0.9mm thick ( two flanges of 15mm each and web 45mm) from the soffit 1200mm centre to centre both ways with ceiling angle soffit cleat of size 27 x 37 x 25 x 1.6mm thick fixed to soffit with rawl plug. Ceiling section of 90 x 25 x 5mm fixed to the intermediate channels with the help of connecting clip 2.64mm dia and in direction perpendicular to the intermediate channel at 365 mm centre fixing gypsum board with screws 250 mm centre to centre including jointing compound joint paper tape and drywall top coat and all as specified and shown on drawing No. DGNP/TD/211 sheet 1/1 and as per manufacturers instructions complete all as specified and as directed.
S&F aluminium powder coated frame for doors, partitions, windows and ventilators with one or more rebates of extruded built up standard tubular and other section of approved make according to IS 1868 (Thickness or powder coating not less than 50 micron).) fixed with rawal plugs, aluminium anodised screws or fixing with clamps or with expansion hold fasteners including necessary filling up of gaps of junctions at top and bottom and sides with required PVC/neoprene felt etc. Aluminium sections should be smooth, rust free,straight mitred and jointed mechanically wherever required including cleat angle, PVC/Neoprene gasket for glazing, panelling, aluminium anodised screws etc. complete all as specified and as directed.
S&F powder coated aluminium door shutters, sections weight not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing and powder coated aluminium snap beading screws complete all as specified. (thickness of powder coating not less than 50 micron) as per architectural drawings and complete all as specified and as directed. Note : Only aluminium shutter for the doors shall be measured in sqm. All the aluminium fittings/fixtures such as butt hinges, tower bolts, handles etc, Pre-laminated particle board and sheet glass shall be measured and paid separatly under relavent items
M&L for Mild steel in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, channel, angle or flat sections) including distance pieces, cleats etc., confirmings to Fe-410-W (Gde E-250 quality A) complete all as specified and as directed.
M&L steel rolling shutters,(thickness of laths 1.25mm) gear operated type without ball bearing with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple, guide channels and one shop coat of primer including erected in position complete all as specified and as directed.
Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and as directed.
S&F 12mm thick pre-laminated particle board, interior grade, pre-laminated on both sides with decorative choice lamination and fixed in aluminium partitions, doors shutters etc, fixed with aluminium glazing clips complete all as specified and as directed.
Material and labour for water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terrace etc., consisting of following sequences of operations on RCC surfaces for non accessible roof surfaces:- a) Roof slab shall be cleaned thoroughly and apply cement slurry @3 kg/sqm b) Provide with minimum 20 mm thiick PCC M-40 (using 12.5mm graded granite stone aggragate) using ready mix concrete in roof padding mixed with water proofing compound @3% by weight of cement or as per manufacturer instructions of varying thickness to maintain required slope. c) Clean the surfaces thoroughly and apply a coat of hot blown bitumen of grade 85/25 @1.2 kg/sqm over bitumen primer @ 0.5 kg/sqm. d) Polymeric water proofing (Actatic poly propelene) membrane 3 kg/ Sqm and minimum 3mm thick reinforced with polyester non woven fabric (non woven fabric wt. not less than 150 gms/sqm) shall be laid over the entire surfaces. e) A coat of hot blown bitumen of grade 85/25 @1.20 Kg /sqm shall be applied over water proofing membrane and finally it shall be finished with a coat of bituminous aluminium paint @ 0.1 kg/sqm complete all as specified and as directed.
Item No 1.105 Contd., Note:- (i) WPC will be measured and paid separately (ii) Minimum cement content shall be 360 Kg/Cu.m. of concrete for M-40 using Portland slag cement with minimum slag content of 50% (fifty percent) for items covered (iii) Design mix shall be as per IS-456-2000. Maximum size of aggregate shall not exceed 20 mm and slump shall be 50mm to 100mm and maximum water cement ratio 0.4. (iv) Unit rate shall be deemed to include for interalia for preliminary design mix and works test cubes. (v) In case at the time of mix design cement content is increased beyond minimum content given above, no extra payment will be made.
M&L for 10mm thick light shade coloured vitrified ceramic tiles (square/rectangular) polished, area of each tiles exc. 0.36 Sq.m. but n. exc. 0.42 Sq.m., in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile surfaces complete all as specified and as directed.
M&L for 10mm thick dark shade coloured vitrified ceramic tiles (square/rectangular) polished, area of each tiles exc. 0.36 Sq.m. but n. exc. 0.42 Sq.m., in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile surfaces complete all as specified and as directed.
M&L for coloured non skid ceramic tiles 7mm to 8mm thick (square/rectangular) area of each tile exc. 0.06 Sq.m. but n. exc. 0.11 Sq.m. in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match with the tile surfaces complete all as specified and as directed.
M&L for 40mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded granite stone aggregate) as in floor, pavements finishing even and smooth without using extra cement complete all as specified and as directed.
M&L for 150mm thick cement concrete 1:4:8 type D2 (using 40mm graded granite stone aggregate) for sub base of floor complete all as specified and as directed.
M&L for 100mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded granite stone aggregate) as in flooring, pavements finishing even and smooth without using extra cement complete all as specified and as directed.
M&L hydrauilcally presed cement concrete tiles of 200X200X20/22mm size confirming to IS -1237-1980 shall be laid on 15mm thick screed bed in CM (1:4) jointed and pointed in cm 1:3(joint thickness not exc 5 mm thick) complete all as specified and as directed.
M&L for coloured glazed ceramic tiles 600X600X10mm thick as in floors set and jointed in neat cement slurry and pointed in white coloured cement to match the tile surfaces complete all as specified and as directed
M&L for coloured glazed ceramic tiles 300X200X7mm thick set and jointed in neat cement slurry and pointed in coloured cement in vertical surfaces such as skirting/dado etc.complete all as specified and as directed
M&L for 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:3 and finishing the surface fair and even without using extra cement for dado/skirting complete all as specified and directed.
M&L for 20mm thick polished grante slab (of any type)work (table rubbed and polished ) in steps, jambs,pillars , slabs window cills , cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for chamfer, splays or arris in face work to granite slab exc 15mm but not exc 50mm wide complete all as specified and as directed.
S&F machine cut kota stone slab 20-25 mm thick as in floors over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specifed and as directed. Note:- Sreed bed shall be measured and paid seperately
All as per item no 1.118 here-in -before but on vertical wall surfaces such as skirting/dado complete.
M & L for machine pressed pre-cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thick, M-40 grade with grey cement and no pigment over 50mm thick sand cushion bed complete all as specified and as directed.
M&L for 15mm thick screed bed or bedding layer in CM (1:4) for laying floor finishes complete all as specified and as directed.
Supply only Integral Water Proofing Compound.
M&L Leak proof treatment to water tanks by using Dr. Fixit / Fosroc or equivalent chemical at the ratio as specified by manufacturer complete all as specified and as directed.
M&L for 20mm thick screed bed or bedding layer in CM (1:4) for laying floor finishes complete all as specified and as directed.
M&L for 1.5mm thick aluminium dividing strip of 28mm wide inserted in position in floor/ ramp complete all as specified and as directed.
M&L for rendering 10mm in CM 1:3 on fair faces of brick work or concrete surfaces, finished fair and even without using extra cement complete all as specified and as directed.
M&L for rendering 5mm thick in CM 1:3 on fair faces of brick or concrete surfaces as in ceiling surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:6 finished fair and even without using extra cement complete all as specified and as directed.
M&L 75mm thick Cement concrete type C-2 ( 1:3:6) using 40mm stone aggregate as in plinth protection finished even and smooth without using extra cement etc complete.
M&L for Precast cement concrete 1:2:4 type B0 (using 12.5 mm graded crushed Granite stone aggregate) as in louvers and jallies 25 mm thick set in cement mortar 1:4 including all mouldings but excluding frame complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 in two layers first layer 10mm thick and second layer 5mm thick mixed with water proofing compound as per manufacturer's instructions and finish the surface fair and even without using extra cement complete all as specified and as directed. Note: Supply of WPC will be measured and paid for separately.
M&L forming V grooves in plaster n exc 10 mm deep and n exc 10mm wide on face of wall and junction complete
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:6 finished fair and even without using extra cement and providing grooves of size 10mmx10mm at junction of wall and column,beams etc complete all as specified and as directed.
M&L for rendering 15mm thick on stone masonary surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of surfaces and applying three coats of white wash on newly plastered surfaces of ceilings complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls applying two coats oil emulsion distemper over a coat of primer and 3mm thick wall care putty complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls and applying two or more coats of putty to obtain smooth surface and applying two coats of plastic emulsion paint over one coat of primer and complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior emulsion weather proof paint with anti fungal properties over a coat of primer as per manufacturer's instructions complete all as specified and as directed.
Supply and fixing 5mm thick clear float glass of ordinary quality with frosted on one side of approved brand and shade fixed in position with and including PVC/Neoprene gasket for glazing, glazing clips in doors, windows, partitions in squares not exc 0.50 Sqm in each pane etc complete all as specified and as directed.
M&L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of steel or steel based surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of steel or steel based surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of black bitiminious paint over a coat of red oxide primer complete all as specified and as directed.
M&L for preparing new steel surfaces of any description over 10cm width or girth and applying two coats of aluminium paint over one coat of red oxide primer complete all as specified and as directed.
Supply and fixing Trapezoidal profiled galvalume sheeting in lengths upto 12m to suit the site requirements.The profiled sheets shall be made out of 0.50mm base metal thickness, Cold Rolled steel of 550 Mpa yield strength conforming to IS 513 (1994) with hot dip metallic coating at minimum 150 gm/Sq.m. zinc- aluminium alloy coating mass (55% Aluminium, 43.5% zinc and 1.5% silicon) total of both sides. The colour shall have a total coating thickness of 35 micron of silicon modified super durable polyester paint system of approved colour, comprising of 20 microns exterior coat on top surface and 5 microns reverse coat on back surface over 5 microns primer coat on both surfaces.Roofing/wall cladding sheets shall be factory cut and supplied in required lengths (of upto 12 m) to suit shop drawings. The roofing/wall cladding sheets shall be crest fixed with 12- 14X55mm SDST screws ITW/ Corroshield make IS 1022 base material with TEK3/TEK4 point having flange thickness of minimum 2mm with special cyclonic washers all as per manufacturer's instructions. Roofing/wall cladding sheets shall be crest fixed with minimum 5 Nos. of above specified screws per metre sheet width at all the purlins/runners. Colour of sheeting shall be as apprroved by GE.
M&L for Forming 20 mm thick Expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound Grade 'A' for 200mm thick concrete slab complete all as specified and as directed.
Supply and fix galvanised steel water tubing 40 mm bore medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid on floors including testing complete all as specified and as directed.
All as per Item No 1.146 here-in-above 25 mm bore complete.
All as per Item No 1.146 here-in-above 15 mm bore complete.
S&F 110 mm bore UPVC pipes (SCH-40) of approved quality with all necessary out let bends, shoes,offset pieces and necessary hardwre fittings complete all as specified and as directed.
S&F 110mm bore PVC (SWR) rain water pipes single socketed in any length with rubber ring joints laid in trenches and floors or fixed to wall with brackets complete all as specified and as directed.
S&F 75mm bore PVC (SWR) rain water pipes single socketed in any length with rubber ring joints laid in trenches and floors or fixed to wall with brackets complete all as specified and as directed.
S&F PVC (SWR) vent cowl suitable for 75mm bore pipes including jointing with solvent complete all as specified and as directed.
S&F PVC (SWR) bend any radius suitable for 110mm bore pipes including jointing with solvent complete all as specified and as directed.
S&F PVC (SWR) bend any radius suitable for 75mm bore including jointing with solvent complete all as specified and as directed.
S&F PVC (SWR) branch pieces, (single Y/T), equal or unequal suitable for 110mm bore pipes including jointing with solvent complete all as specified and as directed.
S&F PVC (SWR) branch pieces, (single Y/T), equal or unequal suitable for 75mm bore pipes including jointing with solvent complete all as specified and as directed.
Supply and fix 110/125mm dia PVC (SWR) floor trap plain with grating, including jointing with solvent cement complete all as specified and as drected.
S&F bib taps, suitable for 15mm bore pipes fancy type, cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S & F ball brass valves, suitable for 20mm bore pipes high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
S&F chromium plated fancy type stop valve with suitable for 15mm bore pipes long shank (concealed type), cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F chromium plated pillar taps, fancy type, suitable for 15mm bore pipes, cast copper alloy with capstan heads, screwed down high pressure with or without lettered Hot or cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed .
S&F 2000 Litres capacity of rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) triple layered ISI marked, hoisted and fixed in position complete all as specified and as directed.
S & F 25mm dia ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
S&F brass water bar 230 mm wide 22 gauge fixed in concrete as in construction joints complete all as specified and as directed.
S&F PVC connection (high density) 15mm dia 450mm lenth with PTMT nuts both ends with rubber washer complete all as specified and as directed.
S&F aluminium anodised tabular towel rail 20mm dia D type 600mm long between flanges complete all as specified and as directed.
M&L for PVC (SWR) gully trap 125/110mm setting and jointing with solvent complete all as specified and as directed.
S & F vitreous china urinals partition plate coloured of size 310x700mm including grouting complete all as specified and as directed.
Supply and fixing soap dish vitreous china white, size 160x160x90mm complete all as specified andas directed.
S&F coloured toilet paper holder of vitreous china box type fixed to walls with chromium plated brass screws complete all as specified and as directed. Make: CERA Model No. F5001109 or its equivalent of approved make.
S&F coloured vitreous china urinals half stall type 345mmx320mmx560mm with and including 32mm dia CP bottle trap required of lenth of 40mm dia PVC waste pipe with fittings concealed in wall upto PVC pipe which is embeded in platform , 15mm dia concealed CP stop cock CP spreaders with unions and clamps, teak wood plugs CP screws complete all as specified and as directed. Make: Prayag or its equivalent of approved make.
Supply and fixing of size 560x470mm vitreous china under counter wash basin with oval type brackets including cutting for and pinning in ends of brackets , 15 mm dia CPbrass waste fittings excluding waste pipe complete all as specified and as directed. Make: CERA Model No. 1005A or its equivalent of approved make.
S&F vitreous china wash hand basin, white, flat back, size 630x450mm excluding taps, waste, chain and flug and porcelain stopper including brackets including cutting for and pinning in ends of brackets, 15mm dia CP brass waste fittings complete all as specified and as directed.
S&F vitreous china Wash down water closet of size 670mmx350mmx760mm (excluding flushing cistern and flush pipe) including plastic water closet seat , closed pattern with flat bottom cover, mild steel chromium plated or aluminised hinging device, fixing bolts, etc complete all as specified and as directed. Make: CERA Model No. S1013159 S trap 250mm or its equivalent of approved make.
Supply and fix sinks with drainage board made of stainless steel 1 mm thick kitchen/laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915x460 mm bowl size 410x330x160 mm complete all as specified and as drected.
Supply and fix PVC valveless, syphonic action type low level flushing cistern, 10 ltrs capacity, white with inlet ball valve, float and handle soft touch type including brackets, PVC flush pipe etc fixed with CP brass screws complete all as specified and as directed.
S&F urinals spreader of PTMT any colour for fixing with 15mm dia pipe min wt 600 gms including union and clamps complete all as specified and as directed.
S & F Brass chromium plated hand shower (Health faucet) with angular stop cock, 1 m long flexible tube and wall hook complete all as specified and as directed.
Supply and fixing stainless steel SS-304 grade window stays for adjustable friction window of size 305mmx500mmx950mm with necessary stainless steel screws etc complete all as specified and as directed.
Supply & filling weather structural non sag elastomeric PU sealent over backer rod of approved quality to the gap between aluminium/ stone/ wood frame and adjecent RCC/ Brick/ Stone/ Wood/ Ceramic/ gypsum work as per architectural drawings complete all as specified and as directed.
M&L for 50 mm bore 1.2mm thick stainless steel pipes grade 304S for staircase railing including buffing etc complete all as specified and as directed.
M&L for 40 mm bore 1.2mm thick stainless steel pipes grade 304S for staircase railing including buffing etc complete all as specified and as directed.
M&L for 25 mm bore 1.2mm thick stainless steel pipes grade 304S for staircase railing including buffing etc complete all as specified and as directed.
M&L for curtain ,Harrison curtainrails,mild steel, chromium plated with fixing brackets,stops, rollers etc.complete all as specified and as directed.
Supply and laying reinforced concrete pipe, 600mm bore class NP2, laid in trenches and jointed with collars complete all as specified and as directed. Note:- Excavation and earth work shall be measured and paid separately.
M&L for 150mm dia salt glazed stone ware of grdae A (ISI marked) laid in trenches and jointed in cement mortar (1:1) and testing on completion complete all as specified and as directed.
M&L cast iron pipes for 150mm bore with spigot and socket ends centrifugally cast class LA in any lenth laid in trenches jointing and testing on completion complete all as specified and as directed.
M&L for plain cement concrete 1:3:6 type C2 (using 40mm graded Granite stone aggregate) as in concrete bed to drain pipes including packing under and haunchig against the sides of pipes after they are laid and tested for 600mm bore pipes complete all as specified and as directed.
M&L for plain cement concrete 1:3:6 type C2 (using 40mm graded Granite stone aggregate) as in concrete bed to drain pipes including packing under and haunchig against the sides of pipes after they are laid and tested for 150mm bore pipes complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30 cm girth complete all as specified and as directed.
Rolling and consolidating formation surfaces in cutting using power roller exc. 8 tonne and n.exc 12 tonne complete all as specified and as directed.
M & L for 150mm thick [spread thickness) soling [or sub base) with broken boulders or quarried stone, interstices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and as directed.
Material and Labour for wet mix macadam by providing, laying, spreading and compacting of graded stone aggregate as per Table 400-11 and satisfying the physical requirement as per Table No. 400-10 of MORTH specification for wet mix macadam including premixing the material in a wet mix plant at OMC, carriage of mixed material to work site in tipper to paver, laying in uniform layers in sub-base/ base course on a previously well prepared surface with mechanical paver finisher to required grade, level, and alignment, compacting with power vibratory roller to achieve the desired density of 98% including protection of edges, machinery, lighting, guarding, barricading, maintenance of diversion road, loading and unloading all lead and lift etc with lead of mixed material n. exc. 10 km and complete all as specified and as directed.
M&L for applying evenly a priming/ tack coat with bituminous primer @ 10 kg per 10 sq metre using paving bitumen of viscosity VG30 over WMM surfaces complete all as specified and as directed.
M&L 50mm thick premix bituminious macadam laid/rolled and compacted to required gradient and camber (consolidated thickness) complete all as specified and as directed.
M&L bituminous premix asphaltic dense concrete 40mm consolidated thickness with 5.5% binder content of viscosity VG30 by weight of total mix, rolled and compacted to required gradient and camber complete with mechanical paver rolled as per IRC norms and compacted with power roller 8 to 12 ton complete all as specified and as directed. Note for Item Nos 1.198:- Mix design shall be carried out through a government lab. In case if design of bitumen content is more than the specified, no additional payment will be admissible. However, if bitumen content is less than specified, same shall be adjusted as per relevant SSR item as applicable..
M&L Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles n exc 5kg each complete all as specified and as directed
M&L forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick, watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and as directed.
Construction fo RCC septic tank, 50 users capacity, designed to carry sewage and sullage water in ordinary soil,foundation in PCC 1:4:8, Brickwork in CM 1:4,RCC M-30 mix in walls,base slabs,baffle walls,roof slab incl beam with vent shaft ,manhole opening,with connections etc.,complete with effective 1.5mtr and overall depth of 3mtr slab covers having 6mm plate embedded all round/fibre reinforced cover with angle iron frame vent shaft and sludge chambers etc complete of size 1.8m x 6.0m as per typical drawing no.DGNP/TD-213 of sheet 1/1 complete all as specified and as directed.
Construction of soak well excavation in any type of soil,foundation in PCC 1:4:8,walls of in honey combed masonry with top ring of M-25 concrete incl intercepting chamber and screen chamber made of brick masonry in CM,RCC cover slab in M25/SFRC Cover ,interconnecting pipes of RCC/DWC complete filled with brick bats of size,reinforced cover with angle iron shaft and sludge chambers etc complete of size 1.80m x 6.0 m as per typical drawing no.DGNP/TD-202 of sheet 1/1 complete all as specified and as directed.
SUB TOTAL OF SCHEDULE "A" Part - I
SCHEDULE "A" PART - II [AIR CONDITIONING]
Design, supply, installation, testing and commissioning of water cooled screw chiller type compressor, Central A/C plant complete with all equipments and accessories of nominal capacity 3 x 80 TR each (Two number working and one number standby) complete including all accessories all as specified and as directed. Note:- Complete design of chilled water plant along with necessary calculations, duly depicting the components mentioned at particular specifications will be submitted by the contractor for approval of the Accepting Officer. A single line diagram will also be submitted along with design for approval of the Accepting Officer.
Item No. 2.01 Contd., (a) CHILLER PACKAGE UNIT:- Micro processor controlled, factory assembled and factory tested water cooled Chiller package comprising of semi hermetic/hermetic scroll compressor (either single compressor or multiple compressor with independent refrigerant circuit) using HFC-134-A/HFC-410-A/HFC-407-C of zero ozone depletion potential in single refrigeration circuits, Refrigerant driven with 2-pole squirrel cage induction motor 3 Phase 415V suitable for min 80 TR refrigeration capacity, water cooled condenser and DX cooler with thermostatic expansion valve complete with inbuilt control panel having microprocessor based control for operation of compressor, condenser, chillers having features of auto operation, min run time equalization, auto restart after power failure, built in time delay, fault diagnostic etc, complete with suitable capacity contactors duly pre wired and inter connected - 03 Nos. (b) CONDENSER WATER CIRCULATION SYSTEM:- compreising the following :- (i) FRP induced drft cooling tower two in Nos of 50% capacity of above working plant capacity, complete installed on suitable RCC staging including PCC flooring in around the staging with spray section, honey comp fill basin, fan, TEFC Motor, intake bird screen and other accessories (as per manufacturers tech specifications ) -02 Nos (Both will be working same time.
Item No. 2.01 Contd., (ii) PVC/HDPE make up water tank of 2 x 5000 ltr capacity installed placed on PCC/Brick staging/RCC of suitable load carrying capacity platform for makeup water requirement including brass float valve with polyethylene ball, over flow and drain arrangement incoming connection of GI pipe 25 mm dia medium grade from tank to tapping point - 01 Job. (iii) End suction type 3 phase electric pump set of 100% capacity and discharge as per AC plant capacity and FASD starter for re-circulation along with rubber vibration isolation pads (one number working and one No will act as standby). Necessary pressure gauge on discharge and suction of pump shall be provided at the outlet of each pump - 02 Nos (1 No will be standby). (iv) Condenser water piping of GI medium grade (ISI marked), pipe and fittings for interconnecting the cooling tower with condensers and pumps, make up water tank, drain pipe, complete with Y strainer, NRVs and butterfly valves - 01 Job. (v) Non chemical type on line scale preventer of size as sper the capacity of the condenser water pump flow - 02 Nos (c) CHILLED WATER CIRCULATION SYSTEM :- Comprising of the following :- (i) split casing type 3 phase electric pumping set of 100% capacity discharge as per the capacity of plant working on 415 volts AC for recirculation of chilled water with ribbed rubber vibration isolation pads. (one working and one standby) Necessary pressure gauges on discharge of pump shall be provided at outlet of each pump- 02 Nos.
Item No. 2.01 Contd., (ii) Chilled water piping with MS heavy grade Class 'C' ERW pipe of suitable diameter including all weldable fittings including Two coats of synthetic enamel paint over a coat of red oxide as directed, butterfly valve, NRVs for chiller, chilled water pumps with AHUs and fan coil units. Chilled water pipelines shall be insulated with 50mm thick EPS (Expanded Polystyrene) pipe section TF quality, and cladded with Aluminium sheet 26 SWG, including water flow switches and electrically opearted modulating valve at each AHU - 01 Job with provision of connecting external/mobile chiller unit. Note:- Minimum thickness of insulation will be 50mm up to pipe size 150mm dia and 75mm thick if pipe dia is more than 150mm. (iii) Expansion tank of 2000 ltrs capacity made out of minimum 6mm thick MS sheet including connections and insulation with 50mm thick fibre glass wool covered with chicken wire mesh of density of 24 kg/cum finished with sand cement plaster including civil works and painting with 3 coats of cement based paint and epoxy paint and necessary piping, control valves on inlets and wash out, float valve etc -01 Job.
Item No. 2.01 Contd., (d) AIR TREATMENT SYSTEM :- Comprising of the following:- (i) AIR HANDLING UNIT (AHU):- Double skin construction air handing unit suitable for chilled water system made out of extruded aluminum structural frame/aluminum corners and intermediate connecting pieces and panels of 0.6m, galvanized steel sheet on both sides with 25mm thick pressure injected PUF (Poly Urethene Foam) of density (38+ 2kg/cum) using CFC free R-141b blowing agent, the panels having scratch free palstisol coating on outer side. The fan section should be mounted on anti vibration spring isolators and free from main structure. The fan shall be DIDW (Double inlet Double Width) back ward curved centrifugal fan with air discharge upblast, belt driven with TEFC (Totally Enclosed Fan Cooling) induction motor of suitable capacity. The coil section consist of 6 row deep coil with min 12 fins/inch duly coated. The filter section consist of prefilter with 10 micron 90% efficiency. The other accessories are view port, limit switch, stainless steel (SS3) drain pan, volume control damper, mixing chamber for 2x80TR plant with Energy Efficient Motor(EE Series) of suitable capacity and specified makes, AHU shall be in sufficient quantity so as to provide equal distribution of UVC(Ultra Vilot) energy on the coil and in the drain pan all as specified - 01 Job (ii) Accoustic insultation with 25mm thick fibre glass rigid boards and finished with RP tissue paper and 28 gauge aluminium perforated sheet upto 5mt from outlet of the air plenum including air plenum all as specified and directed.
Item No. 2.01 Contd., The fan shall be DIDW (Double inlet Double Width) back ward curved centrifugal fan with air discharge upblast, belt driven with TEFC (Totally Enclosed Fan Cooling) induction motor of suitable capacity. The coil section consist of 6 row deep coil with min 12 fins/inch duly coated. The filter section consist of prefilter with 10 micron 90% efficiency. The other accessories are view port, limit switch, stainless steel (SS3) drain pan, volume control damper, mixing chamber for 2x80TR plant with Energy Efficient Motor(EE Series) of suitable capacity and specified makes, AHU shall be in sufficient quantity so as to provide equal distribution of UVC(Ultra Vilot) energy on the coil and in the drain pan all as specified - 01 Job (iii) 5 micron filters shall be provided in a GI sheet plenum for AHUs. The filters shall have efficiency of 99% when tested as per BIS 6540-Part-I and made out of Non-woven synthetic/polyester/polypropylene media sandwitched between HDPE mesh on one side for additional coarse filteration and aluminium expanded mesh on the other side for mechanical support. Media is deep pleated, encased and sealed in sturdy GI frame for longer life including rubber gasket of appr size 600 x 600 mm.
Item No. 2.01 Contd., (e) AIR DISTRIBUTION SYSTEM:- Comprising of the following:- Supply and return air ducting made out of commercial grade GI sheet Zinc coating 120 grade IS : 277 and fabricated as per IS-655, but not less than 22 SWG thick, Ducting wherever passing through unconditioned space shall be insulated with resin bonded Fibre Glass Wool 25mm thick (density 24 Kg/Cum) covered with GI chicken wire mesh and cladded with aluminium foil fixed with adhesive tape. Where these ducts are passing through open area, insulated with 50m thick fibre glass wool density 24 kg/m3, covered with polythene sheet faced Hessian cloth, GI chicken wire mesh and protected with sand cement plaster. Required portion of the duct will be acoustically covered with standard size of AC sheets supported by internal channels and complete in all respect- 01 Job. Note:- The contractor should examine the entry of supply air duct/return duct in the building. (i) GI ducting for supply and return air shall be factory fabricated as per SMACNA-1995 standards and all as specified. (ii) Aluminium anodised double deflection type grills/diffusers complete with MS powder coated volume control damper for supply andair grill/diffusers and aluminium powder coated grills fixed bar type without volume control damper for return air, the anodised aluminium grills shall be continuous and flush with the inside walls of the hall to provide maximum free space inside the building - 01 Job.
Item No. 2.01 Contd., (iii) Aluminium powder coated fresh air grill with MS powder coated volume control damper- 01 Job (iv) Fire dampers automatic type with flusible link (CPRIcertified) and operated with stainless steel spring made out of 16 SWG wire and limit switch to be provided in main supply duct interlocked with AHU motor to cut off circulation of air in case of fire for each AHU. (v) Fresh air damper with GI cowl/fittings and mosquito proof, netting shall be provided for each AHU. (f) ELECTRICAL DISTRIBUTION SYSTEM:- Comprising of the following:- (i) Electrical panel board : Cubical type, floor mounted, vermin proof, dust proof OEM design and factory made, Indoor type, powder coated with seven tank process switch board panel made out of MS sheet not less than 16 SWG powder coated paint suitable for operation on 415 volt of 50 Hz AC supply, internally wired with copper conductor wire, comprising of the following:- (aa) Air insulated Copper bus bar of adequate size for Phase and Neutral (ab) Main incoming ACB and outgoing MCCBs of adequate capacity for chilled water pumpsets, AHU blower motors, Condenser, condenser fans (ac) One digital electronic energy meter of suitable capacity at main incoming.
Item No. 2.01 Contd., (21) The tenderer need to submit the drawings for chiller units, AHUI, electrical panel etc including all major components for approval of the accepting Officer before placing the order. The contractor should submit all the supporting caculations as well as OEM recommendations for all the motors, pumps, AHU s, cooling towers, De-humidifiers etc to get the decide conditions in the specified space. (22) The inside design conditions required is temp -22 + OR - 2 degree C, and relative humidity is 55%+ or - 5%.
Supply, installation, testing and commissioning of Water cooler fully stainless steel, electric driven single phase having 120 Ltr storage capacity and nominal cooling capacity 60 Ltr/hr using green refrigerant R134A having 2 nos faucet including drain pipe of suitable length complete all as specified and as directed.
Supply installation, testing and commissioning water purifier (RO+UF+UV+TDS control) fixed on wall equipped with hydro static tank and purification capacity 15 Ltr/hr including with all accessories including flexible hoses and sediment filter complete all as specified and as directed. Make-KENT Model No. KENT Excel Plus
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & desinged for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 3.0 KVA complete all as specified and as directed.
SUB TOTAL OF SCHEDULE "A" Part - II
SCHEDULE "A" PART - III [INTERNAL ELECTRIFICATION]
Material and labour for point wiring (light/fan/) with 1.5 Sq mm (nominal cross section area) flexible LSZH cable with copper conductor, single core multi stranded 1100 V graded confirming to IS 694 : 1977 drawn in concealed/surface conduit including provision of 20mm dia rigid steel conduit medium grade as per IS 9537 (part-II 1981) with conduit accessories including concealed terminal boxes fabricated out of 2 mm thick MS sheet fitted with 3 mm thick Hylam sheet top cover for fixing switches including 1.5 Sqmm one single core flexible LSZH cable with multi stranded copper conductor as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
All as per Item No 3.01 here-in-above but 1.5 sqmm one light controlled by 2-way switches complete all as specified and as directed.
All as per Item No 3.01 here-in-above but One 3 pin socket outlet 5amps on the same board with other switches, with cables 1.5 sq. mm size complete all as specified and as directed.
All as per Item No 3.01 here-in-above but with 2.5 Sq mm (nominal cross section area) flexible LSZH cable with 2.5 Sqmm one single core flexible LSZH cable with multi stranded copper conductor as earth continuity conductor for 5/15A switch cum socket complete.
All as per Item No 3.01 here-in-above but with 4.00 Sq mm (nominal cross section area) flexible LSZH cable with 4.0 Sqmm one single core flexible LSZH cable with multi stranded copper conductor as earth continuity conductor for 5/15 Amp switch cum socket complete all as specified and as directed.
Supply and fix 5A, 230V flush type piano switch, Single pole complete all as specified and as directed.
All as per Item No 3.06 here-in-above but controlled by two way switches complete all as specified and as directed.
Supply and fix 5 A 230V switch/ Socket outlet flush type One way , 2/3 pin, ,multipurpose complete all as specified and as directed.
Supply and fix switch socket outlet multi purpose 3 pin 5/15 amp and one pin 5 amp controlled by one switch complete all as specified and as directed.
M&L for provision of single pole and nuetral metal clad enclosure with 2 pin and earth plug and socket complete with Single Pole MCB of capacity 20 Amps, 240V complete all as specified and as directed.
S&F ceiling rose surface mounted bakelite, 65X50mm having three terminals complete all as specified and as directed.
Supply & fix LED 20 W 4 feet 100 Lum/Watt light along with fixture, including fixing arrangement like PVC round blocks, screws etc and suitable connecting copper cable from ceiling rose to light fitting including necessary connection with 3 core copper flexible cable complete all as specified and as directed. Make: Model No. LDL-20-CDL of Crompton make or its equivalent as approved by GE
Supply & fix LED 24 W recessed light fitting with glare free uniform illumination with longer life and less maintenance and connecting 3 core copper cable complete all as specified and as directed. Make: Model No. LCTLRNE-24-FO-CDL of Crompton make or its equivalent as approved by GE
Supply & fix LED 10 W 2 feet light along with fixture, retrofit type including fixing arrangement like PVC round blocks, screws etc and suitable connecting copper cable from ceiling rose to light fitting including necessary connection with 3 core copper flexible cable complete all as specified and as directed. Make: Model No.LDL-10-CDL of Crompton make or its equivalent as approved by GE
S&F down light 30 W suitable for any modern professional workspace, aluminium housing ensures long life including necessary connection with 3 core copper flexible cable complete all as specified and as directed. Make: Model No. CDR-216-30-57-SL-NWH of Crompton make or its equivalent as approved by GE
Supply and fix energy efficient ceiling fan 1200mm/48" ES-5* with stepped type electronic regulator and extension down rod including necessary connection with 3 core copper flexible cable complete all as specified and as directed. Make: Model No. Aeroking 50 of Havells or equivalent as approved make.
Supply and fix heavy duty exhaust fan 300mm sweep 900 RPM operates in 230 V, single phase with louvers with all accessories and necessary PCC work complete all as specified and as directed. Make: Model No. Terbo jet SP of Havells or equivalent as approved make.
S&F LED light fitting 25 Watts complete with GI pipe bracket clamp etc for fixing arrangement on walls/poles etc complete all as directed. Make: Model No. LST-25-CDL-M of Crompton make or its equivalent as approved by GE
S&F MCB's DB, TPN 4 ways with IP 54 protection, double door, sheet steel phosphetised powder painted with 200 amps rated copper busbar 415Volt, complete all as specified and as directed.
S&F MCB's DB, SPN 8 ways with IP 54 protection, double door, sheet steel phosphetised powder painted with 200 amps rated copper busbar 230Volt, complete all as specified and as directed.
S&F MCB's DB, SPN 4 ways with IP 54 protection, double door, sheet steel phosphetised powder painted with 200 amps rated copper busbar 230Volt, complete all as specified and as directed.
Supply and fix MCB TPN (40-63) Amps, 415V 'C' curve of breaking capacity 16KA complete all as specified and as directed.
Supply and fix MCB SPN (40-63) Amps, 230V 'C' curveof breaking capacity 10KA complete all as specified and as directed.
Supply and fix MCB SP (6-40) Amps, 230V 'C' curve of breaking capacity 10KA complete all as specified and as directed.
M & L for sub main wiring with two runs of 2.5 Sqmm (nominal cross section area) flexible LSZH insulated unsheathed cable with copper conductor, single core multi stranded 1100 V along with one run of 2.5 Sqmm LSZH insulated unsheathed cable with copper conductor, single core multi stranded as earth continuity conductor through and including 25mm bore rigid steel conduit as per IS-9537 (Part-II:1981) and accessories medium grade complete all as specified and as directed.
All as per item No 3.25 here-in-before but two runs of 4.0 sqmm phase wire and one run of 4.0 sqmm as earth wire through and including 25mm bore rigid steel conduit as per IS-9537 (Part-II:1981) complete. Note for item no 3.25 and 3.26 : Two runs of cable as specified of phase wire, one run of earth wire and one run of conduit shall be measured as one unit.
M & L for sub main wiring with four runs of 6 Sqmm (nominal cross section area) flexibleLSZH insulated unsheathed cable with copper conductor, single core multi stranded 1100 V along with one run of 6 Sqmm flexible LSZH insulated unsheathed cable with copper conductor, single core multi stranded as earth continuity conductor through and including 25mm bore rigid steel conduit as per IS-9537 (Part-II:1981) and accessories medium grade complete all as specified and as directed by the Engineer-in-Charge. Note- : Two runs of cable as specified of phase wire, one run of earth wire and one run of conduit shall be measured as one unit.
M & L for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I including excavation/earth work in any strata, adequate quantity of charcoal and common salt, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire including testing complete all as specified and as directed by Engineer-in-Charge. Note: Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI wire 4 mm dia complete all as specified and as directed.
SUB TOTAL OF SCHEDULE "A" Part - III
SCHEDULE "A" PART - IV [LIGHTINING PROTECTION]
Supply and fixing Air termination, single pointed, copper rod 12 mm dia and 300 mm long complete all as specified and as directed.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos 8 mm dia 25 mm long hex head screw two coat of anticorrosive paint including terminal box of suitable size complete all as specified and as directed.
Supply and fix copper strip 20mmx3mm complete with sadles porcelin/hard PVC at not more than one metre and fixing screws etc with two coat of red oxide along with one coat of anti corrosive paint for roof conductors and down conductors above ground complete all as specified and as directed.
M&L for earthing complete with copper earth plate electrode 60cm X 60cm X 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth lead 32mmX6mm by means of bolts, nuts, check nuts and washers of brass all as shown in electrical plate No.3 of SSR Part-I including excavation/earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 40mm bore GI pipe medium grade for copper strip protection including testing complete all as specified and directed. Note :- Earth lead will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser.
M & L for copper strip 32 x 6 mm buried in ground complete all as specified and as directed.
M&L galvanised tubes 'medium grade', with all fittings, for protection of GI Strip laid in trenches, or fixed to wall with suitable fixing clamps of appropriate size including nuts, bolts and washers; for the sizes of 40 mm bore complete all as specified and as directed.
SUB TOTAL OF SCHEDULE "A" Part - IV
SCHEDULE "A" PART - V [EXTERNAL ELECTRIFICATION]
Supply ,Installation, testing and commissioning of 11 KV HT , 25 kA , VCB switchboard 630 Amp VCB . VCB panel indoor type totally enclosed, free standing floor mounting type, compartment based withtruck mounted vacuum circuit breaker motor operated spring type electrically and manually charged operating mechanism suitable for horizontal isolation , horizontal draw out type VCBs with copper busbars, self supported insulated busbar with full voltage rated should be used. The switchgear panel shall be of sheet steel construction with Aluminium Zinc not less than 2.5 mm thickness for load bearing section and not less than 2 mm thickness for non load bearing secxtions and shall tottaly dust and vermin proof. The VCB panel confirming as per IEC 62271-100/200 standards and IP 4X class of protection comprising necessary bus bars extension and connections , synchronizing of panel and following protective and contro devices as specified below. Circuit breaker shall be suitable for E2, M2, C2 duty. Vaccum interrupters of the circuit breaker shall also be the manufacturers of the Vaccum interupter, relay, Panels shall have buiilt infeature of condition, Thermal , Environmental & circuit breaker monitoring along with HMI as per specifications. The switchgear and control gear panels shall be of fully arc proof arc proof for 1 sec. Make : Schneider / ABB / BHEL / Siemens / CG
Item No 5.02 Contd., Relay shall be be microprocessor based numerical relay communicable type in line with IEC 61850 protocol and RS-485 port comprisingof three over current, one earth fault protection relay with high set for both phase & earth and with fault memory equivalent , universal auxiliary supply, master trip relay, trip circuit supervision relay, digital multifunction meter with RS-485 port with 0.5 with 3 Nos copper wound double ratio double core current Transformer having CT ratio 100-50/5-5A for outgoings, PT, MFM 0.2 class, power pack complete all as specified and as directed. Note:- For transformer outgoing differential relay & Annunciator 12 window shall be considered.The switch gear shall be have temerature measurement sensors at all critical points medium voltage cable connection & busbar joints/connections. The system shall help operator during local investigation and local mnitoring . This HMI shall give access to the condition monitoring. ThisHMI shall give access to condition monitoring data and alarms. while operate is inside the MV electrical room, HMI. Make : Schneider / ABB / BHEL / Siemens / CG
Item No. 5.02 contd…, (viii) 1 Nos of SCADA compatible feeder protection relay with ( over & under voltage relay ), (3 phase over current), N (Earth over current), 51 V (voltage controlled over current), (3 Phase under current), (Negative phase sequence over current), N (Residual over voltage), (directional power protection (under/over active/recative power), U/o (under/over frequency), ((Thermal overload), (Auto Reclose), BF (Circuit Breaker Failure detection), Cold pickup, inrush Blocking. Relay will be on Modbus protocol. (ix) High speed Master Trip Relay - 01 No (ABB/ALSTOM/Siemens/CG) (x) Trip Circuit supervision Relay - 01 No (ABB/ALSTOM/Siemens/CG) (xi) Short time rating for 3 Seconds as per IEC 62271-100 (xii) Anti pumping Relay - 01 No (ABB/ALSTOM/Siemens/CG)(xiii) Air insulated rear end Bottom entry cable box suitable for termination of XLPE cables (xiv) Panel must have additional features (xv) Continous rated closing/tripping coils (xvi) Spring charging handle (xvii) Manual closing/tripping of the CB with compartment door closed (xviii) Transformer Fault Alarm/Trip Aux, Relay for transformer feeder only - 02 Nos ABB/ALSTOM/Siemens/CG (xix) Anti pumping Relay - 01 No ABB/ALSTOM/Siemens/CG (xx) Air insulated rear end Bottom entry cable box suitable for termination of XLPE cables
Item No. 5.02 contd…, (xxi) Panel must have additional features (xxii) Continous rated closing/tripping coils (xxiii) Spring charging handle (xxiv) Manual closing/tripping of the CB with compartment door closed (xxv) Short time rating for 3 seconds as per IEC 62271-100 (xxvi) Annuclator (12 Window) for Transformer Feeder Make : Miniec or equivalent (xxvii) Mechanical endurance test - M-2
Supply and laying in trenches or ducts or passing through the pipe, testing and commissioning of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 240 sqmm complete all as specified and as directed.
Supply and fix copper strip 20mmx3mm complete with sadles porcelin/hard PVC at not more than one metre and fixing screws etc down conductors above ground/wall having hole provision for every one meter and holes should be fitted non corrosive nut-bolt of size M8 all as specified and as directed.
Supply fixing and installation of high galvanized mast light of 16 m height suitable for 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation and feeder pillar box of suitable capacity as per OEM recommendations all as specified and as directed. Note:- Light fitting shall be measured and paid seprately.
Supply and fixing non integral flood light luminary 150 W LED flood light with surge protection, Energy saving and environment friendly long life LED made of pressure Die cast Aluminium housing with IP 65 suitable for highlighting architectural facade and general purpose lighting with 10KV built in Surge protection device with system lumens > 100 lumen/W, THD<10% PF>0.90 & color temp 5700K. Operating voltage range 140V-270V. Minimum life of 50000 hrs, Operating temp – 10 to 50 Deg C complete all as specified and as directed.
Supply and fixing cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240Sqmm complete all as specified and as directed.
M&L for earthing complete with copper earth plate electrode 60cm X 60cm X 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth lead 20 x 3mm strip by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I including excavation/earth work in any strata, adequate quantity of charcoal and common salt, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 32mm bore GI pipe medium grade for copper strip protection and 20 x 3mm copper earth strip including testing complete all as specified and directed.. Note: Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
Supply and lay insulated mat of 1m wide and 2m length for electrical purpose class `B' 2.5mm thick for upto 33 KV as per IS-15652 all as specified and as directed.
M&L for Danger Notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20x15cm size complete all as specified and as directed.
All as per Item No. 5.10 here-in-above but for HT 25x20cm size complete.
All as per Item No. 5.12 here-in-above but 240 sqmm 3.5 core complete.
All as per Item No. 5.12 here-in-above but 120 sqmm 3.5 core complete.
All as per Item No. 5.12 here-in-above but 50 sqmm 3.5 core complete.
All as per Item No. 5.12 here-in-above but 16 sqmm 4 core complete.
All as per Item No. 5.12 here-in-above but 25 sqmm 4 core complete.
Supply and laying reinforced precast concrete cable cover, class HVP unreinforced PCC with peak and all as per IS : 5820-1970 complete all as specified and as directed.
Supply and laying reinforced precast concrete cable cover, class LV, type 1 with peak size 250 mm x 150 mm x 40 mm complete all as specified and as directed.
Supply and spreading river sand in trenches as cushioning to under ground cable on top and bottom of cable and leveling & ramming complete all as specified and as directed. Note:- Punned thickness will be measured.
Supply, Installing, testing and commissioning of LT Panel factory made indoor type as per IEC 61439 Part 1 & 2 (Switchgear OEM design), with following minimum thickness – Load bearing member/Doors – 2mm, Non-load bearing member/internal partitions- 1.5mm, Glandplate/Base channel-3MM, board floor mounted, dust and vermin proof, 3 phase 4 wire with rated operational voltage 415V, rated insulation voltage of 1000V and Impulse withstand of 12KV and minimum internal Arc with-stand of 65KA, 500m Sec as per IEC 61641, weather proof, with separate hinge door for each compartment with Operating handle & locking arrangement with back door common openable ( serewed/Lockable), grouted in PCC 1:2:4 Complete. Painting as per OEM defined 7 Tank process with epoxy powder polymerized at high temperature and 3000A, aluminium busbar (TPN) suitable double compression aluminium cable glands with the following accessories complete all as specified and as directed by Engineer-in-Charge:-
Supply, laying, fixing and clamping GI pipe light grade with all fitings of size 100mm dia bore complete as directed..
Supply, laying, fixing and clamping GI pipe light grade with all fitings of size 80mm dia bore complete as directed..
Supply, laying, fixing and clamping GI pipe light grade with all fitings of size 50mm dia bore complete as directed.
M&L for cable route indicator RCC of size 0.6x0.6x0.1m marked with MES HT/LT cable all as specified and directed.
M&L for divertion of eletric HT/LTcable including necessary joints etc complete all as specified and as directed.
SUB TOTAL OF SCHEDULE "A" Part - V
SCHEDULE "A" PART - VI [EXTERNAL WATER SUPPLY]
Material and labour for cutting existing CI/DI pipe line of sizes 200 mm and inserting CI tees 200x200x100 mm dia both end spigot socket and other side flanged in ground/walls floor etc including testing complete all as specified and as directed.
Supply and lay pipe ductile Iron S/S as per IS : 8329-2000 Class "K-9", 100 mm (4") dia complete all as specified and as directed.
Supply and lay pipe ductile Iron S/S including specials, Class "K-9", 150 mm (6") dia complete all as specified and as directed.
Supply and fix galvanised steel water tubing 50 mm bore medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid on floors or in trenches including testing complete all as specified and as directed.
Supply and fixing Sluice valve suitable for 150mm bore of pipes, flanged of class PN 1.6 including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
All as per item No. 6.05 here-in-before but suitable for 100mm bore complete all as specified and as directed.
Supply and fix DI fitting including nitrile ruppler gasket and nut-bolts upto 150mm bore pipe (Tee, Bend, Y etc) complete as per IS:9523-2000 all as specified and as directed..
Supply and fixing Gun-metal, globe or gate valve suitable for 50mm bore of pipes with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
Supply, fixing, testing & commissioing of mono block pump set 5 HP, 3 phase, 50 Hz including testing and necessary connection with suitable size of cable from statrter to pump testing complete, all as per specified and as directed.
Supply and laying in trenches or ducts or passing through the pipe or galley or surface, testing and commissioning of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric LT power cable (heavy duty) with stranded aluminium conductor 1100 volts grade of size 4 core 10 Sqmm complete all as specified and as directed.
Supply and laying in trenches or ducts or passing through the pipe or galley or surface, testing and commissioning of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric LT power cable (heavy duty) with stranded aluminium conductor 1100 volts grade of size 4 core 10 Sqmm complete all as specified and as directed.
M&L for Non return sluice valve of size 50 mm dia complete all as specified and as directed.
Cutting under road, pavement hard standing for laying of pipe and making good of disturb surface omplete all as specified and as directed.
M&L for valve chamber including excavation in any type of soil, spreading, levelling and refilling etc. PCC (1:4:8) type D2 for foundation, brick work of one brick thick wall in CM (1:4) including internal plaster 15mm thick in CM (1:4) external plaster 15mm thick(1:4) and providing coping in PCC (1;2:4) type B1, angular iron frame of size 50x50x6mm with 6mm thick MS plate cover complete including locking arrangements and having FRP coating of 2mm thick on both inside and outside surfaces complete as specified for the size of chamber 1000mm x 1000mm x 1000mm complete all as specified and as directed.
M&L for divertion /relaying of the existing water pipe lines of any size by excating/demolishing the existing support and relaying incl cutting/weding as necessary complete all as specified and as directed.
S&F 5000 Litres capacity rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) triple layered ISI marked,placed under ground fixed in position complete all as specified and as directed. Note:- Earth work and civil work will be measured and paid under relevent items seperately.
S&F cast iron foot valve 50mm bore including all accessories complete all as specified and as directed.
SUB TOTAL OF SCHEDULE "A" Part - VI
SCHEDULE "A" PART - VII [ FIRE FIGHTING SYSTEM]
Cutting the existing DI/CI water pipe line of any dia and reducing to required length before laying incl insertion of new tees, branches etc for connecting GI pipe suitable size complete for cope points all as specified and as directed.
Supply and fixing Sluice valve suitable for 100mm bore of pipes, flanged of class PN 1.6 including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
All as per Item No. 7.02 here-in-above but 80mm bore.
Supply and fixing fire fighting booster pump suitable to discharge 900LPM at 30m head including with all accessories and suitable capacity starter all as directed and as directed.
M & L for hose reel of 30mtrs complete all as directed and as directed.
M&L for RRL hose pipe 15m length, 63/80mm complete all as directed and as directed.
Material and labour for fabrication of steel supports complete all as specified and as directed.
Supply and fix fire hydrant landing valve, type 'B' (double headed outlet) suitable for 63 mm bore of pipe size confirming to IS-5290 complete all as specified and as directed.
M&L for MS ERW pipe 100mm nominal dia confirming IS : 3589:91 with accessories like sockets, spogets, joints etc complete all as specified and as directed.
All as per Item No. 7.10 here-in-above but 80mm bore.
S & F branch pipe gun metal 63 mm instantaneous inlet, made threaded outlet,15 mm bore nozle short complete all as specified and as directed.
Supply and fix hose box made of 18 guage MS sheet 800mmx600mmx250mm with double door with 4mm thick glasses and door frame made of 16 guage MS sheet painted fire red out side and brilliant white inside yard for fixing 2 Nos of hose pipes of length 15 mtr each all as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I including excavation/earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 40mm bore GI pipe medium grade for GI strip protection and 32x6mm GI earth strip including testing complete all as specified and directed.
M&L for yard hydrant post/stand post 80 mm dia GI /MS both flanged type 1.5 Mtr height complete all as specified and as directed.
M & L for GI strip 32 X 6 mm with saddles and fixing screws etc for roof or on wall conductors and down conductors above/ under ground including porcelain insulators complete all as specified and directed by Engr-in-Charge
Supply and fixing water presuure guage 8 inch dial 0-14 Kgs rating at the delivery side of pump sets complete tubing, fitted with stop cock etc.,complete all as specified and as directed .
Supply, installation, testing and commissioning of 150mm dia 2 way fire brigade inlet with isolation valve with instantaneous SS couplings, 63mm dia with required fittings all as specifeid and as directed.
M&L for divertion /relaying of the existing water pipe linesincl all accessories/equpment of any size by excating/demolishing the existing support and relaying incl cutting/weding as necessary complete all as specified and as directed.
SUB TOTAL OF SCHEDULE "A" Part - VII
SCHEDULE "A" PART - VIII [FIRE AND SMOKE DETECTOR SYSTEM]
S&F of multisensor detector comprises optical smoke and thermistor tempreture sensors which give both a combined singal as well as a separate heat signal for improved false along with isolator modules as required. Positioning of multi sensor detectors complete all as specified and as directed. Operating voltage: 17-28V DC Communications protocol:- Honeywell/Notifier/Appollo/Series 90/XP95 5-9V peak to peak Quiescent current: 500mµA average 750mµ peak Power-up surge current : 1mA Maximum power-up time : 10s Alarm LED current : 3.5mA Remote LED current : 4mA at 5V (measured across remote load) Clean lair analogue value : 23 + 4/-0 Alarm level analogue value : 55 Alarm indicator : 2 Colourless Light Emitting Diodes LEDs; illuminated red in alarm Optional remote LED Dimentions : 100mm diameter 50mm height 58mm (height in base) Weight : Detector: 105g Detector in base :160g Materials : Housing: White polycarbonate V-0 rated to UL94 Terminals : Nickel plated stainless steel smoke element only : Chamber configuration : Horizontal optical bench housing infra-red emitter and sensor, arrange radially to detect forward scattered light Sensor :Silicon PIN photo-diode complete all as specified and as directed.
Supply and fixing of addressable dual action manual pull station- single action connected with back box complete all as specified and as directed.
S & F 2 core x 1.5 sqmm copper armored cable nominal cross section area FRLS PVC insulated unsheathed cable with copper conductor, multi stranded 1100 V as per IS: 1554 including wall mounting/ceiling mounting/laid in trenches with saddles clams screws junction boxes and required steel conduits with nacessary earthing etc complete all as specified and as directed.
Supply and fixing loop sounder visual indicator controlled by full core protocol with fire control panel programme accordingly complete all as specified and as directed..
Supply installation and commissioning of repeater alarm panel for fire detection and alarm system suitable for GSM/GPRS/ necessary SCADA software complete all as specified and directed.
Supply and fix fire point stands with fire bucket hooks and fire extinguishers holding brackets complete all as specified and as directed.
Supply and fixing AFFF type fire extinguishers - mechancial foam type 9 litres capacity complete with initial charge, gun metal cap, discharge hose with nozzle, wall fixing brackets, etc as per Naval pattern Extinguisher complete all as specified and as directed.
Supply and fix CO2 fire extinguishers - 4.5 Kg capacity complete with inital charge, gun metal cap, discharge hose with nozzle, wall fixing brackets etc as per Naval pattern Extinguisher confirming to IS : 15683 complete all as specified and as directed.
Supply and fix Dry chemical powder stored pressure type extinguisher 6 kg capacity with intial charge, gun metal cap, discharge hose with nozzle wall fixing brackets etc as per Naval pattern Extinguisher confirming to IS : 15683 complete all as specified and as directed.
Supply and fix galvanised Sand bucket of 9 Ltr Capacity with hemispherical bottom, painting with two coat of post office red colour out side and white colour in side synthetic enamel paint over a coat of red oxide primer and paint the word FIRE shall be written in out side the bucket in bold black letters complete all as specified and as directed.
Supply and fix galvanised water bucket of 14 Ltr Capacity with hemispherical bottom, painting with two coat of post office red colour out side and white colour in side synthetic enamel paint over a coat of red oxide primer and paint the word FIRE shall be written in out side the bucket in bold black letters complete all as specified and as directed.
Item No 8.12 Contd., Note :- The rate quoted includes the followings:- 1. Supply and installation of 24V fault torrent network card with built in diagonistics and is fully monitered for both sort and open circuits between notes (To installed in fire alarm panel) the maximum No network node is 200. 2. Fire detection and alarm system are to be connected with auto dialer for easy comunication with three recorded massage to stored phone numbers. - 01 set 3. Fire alarm panel is to be secured with suitable non conductive wooden with mica finish to protect from temparing. Make-Apolo/ Notifier/Honeywell. 4. All fire system should be distributed in zones.
SUB TOTAL OF SCHEDULE "A" Part - VIII
SCHEDULE "A" PART - IX [LIFT]
SUB TOTAL OF SCHEDULE "A" Part - IX
RAJYALAKSHMI BUILDERS
jd constructions
K KUMAR RAJA PROJECTS P LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid