| Sl No | Description | Qty | Unit | GOVT CONTRACTOR L2 | KULBINDER SINGH GOVT CONTRACTOR L1 | A.R ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Providing, Installation and Commissioning of DO sensor with sample temperature 0-80 Degree C, Measuring range 0-5mg/l, Measuring Mode: Continuous,RS485 with digital probes (DO) complete in all respects as per the entire satisfaction of Engineer-in-charge. | 1 | Each | 4,55,275 ₹4.6 L | 4,25,415 ₹4.3 L | 5,75,000 ₹5.8 L |
| 2.00 | Providing, supplying & commissioning of Powder Coated and CNC fabricated electric control panel for Automation System of 14 SWCG CRCA sheet thickness and which includes PLC (Programmable logic controller) with appropriate digital and analogue inputs and outputs to control and monitor the whole plant's equipment , Electronic relay card 8 channel, SMPS 4.5 Amps to energise PLC system, HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumps , Submersible Pumps and Instruments .Mobile App (Android/IOS) with User ID and Password to monitor and control the pumping operation from Mobile for 3 users., GSM Based device to send data to Server to remotely monitor and control the operation of pumps and also to analyse the pump start and stop history logging, fault status, fault history, Power Quality Parameters like PF, Current, Voltage, KWH, etc and Software Development complete in all respects as per the entire satisfaction of Engineer-in-charge. | 1 | Each | 6,20,825 ₹6.2 L | 5,80,150 ₹5.8 L | 7,25,000 ₹7.3 L |
| 3.00 | Providing ,supplying, commissioning and Testing of Artificial Intelligence based software "DIZIO Interface" to generate the reports, data and graphical representations for the following features
1. It should generate the reports related to monthly consumption of energy in terms of Values in INR and it also this report will mention all the attributes like Monthly Energy Bills, peak hour violation charges, normal hours KVah,Night KWH consumption, Day KWh consumption, Recorded demand KVa, Violation demand KVa.
2. It should generate the reports related to motor efficiency whether the motors is working efficiently or not. It should generate the popups regarding the excess current consumption or if the motor is not working as per the stipulated efficiency.
3. It should generate the reports related to pump efficiency whether the pump is working efficiently or not. It should generate the popups regarding the pump efficiency If pump is not working as per the stipulated efficiency.
4. Also this system should provide the decision support mechanism so that proper decisions can be taken in terms of Power Quality, Demand Load, Energy Bill, Contract Load, Motor efficiency and Pump Efficiency etc and also it should be capable to integrate more feature as and when required in future.
5. Preventive maintenance of pump, motors and various instruments complete in all respects as per the entire satisfaction of Engineer-in-charge. | 1 | Each | 8,52,600 ₹8.5 L | 7,96,650 ₹8.0 L | 9,75,000 ₹9.8 L |
Tender Value
₹15.8 L
EMD Value
₹31,618
Closing Date
28 Mar 2026, 11:00 amClosed
EE JSD KATRAIN
EE JSD KATRAIN
(SH- Providing, Installation and commissioning of DO Sensor, Electronic Panel and AI based software for online Enfluent monitoring system and flow meter)
2026_HPIPH_132194_4
EE Katrain 10862-10912 dated 19.3.2026
Open Tender
Civil Works
60 days
KATRAIN
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹31,618
11 Apr 2026
21 Mar 2026
28 Mar 2026
21 Mar 2026
28 Mar 2026
21 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
Providing, Installation and Commissioning of DO sensor with sample temperature 0-80 Degree C, Measuring range 0-5mg/l, Measuring Mode: Continuous,RS485 with digital probes (DO) complete in all respects as per the entire satisfaction of Engineer-in-charge. | 1 | Each | - | - | itemH1Code1 | |
Providing, supplying & commissioning of Powder Coated and CNC fabricated electric control panel for Automation System of 14 SWCG CRCA sheet thickness and which includes PLC (Programmable logic controller) with appropriate digital and analogue inputs and outputs to control and monitor the whole plant's equipment , Electronic relay card 8 channel, SMPS 4.5 Amps to energise PLC system, HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumps , Submersible Pumps and Instruments .Mobile App (Android/IOS) with User ID and Password to monitor and control the pumping operation from Mobile for 3 users., GSM Based device to send data to Server to remotely monitor and control the operation of pumps and also to analyse the pump start and stop history logging, fault status, fault history, Power Quality Parameters like PF, Current, Voltage, KWH, etc and Software Development complete in all respects as per the entire satisfaction of Engineer-in-charge. | 1 | Each | - | - | code1.02 | |
Providing ,supplying, commissioning and Testing of Artificial Intelligence based software "DIZIO Interface" to generate the reports, data and graphical representations for the following features
1. It should generate the reports related to monthly consumption of energy in terms of Values in INR and it also this report will mention all the attributes like Monthly Energy Bills, peak hour violation charges, normal hours KVah,Night KWH consumption, Day KWh consumption, Recorded demand KVa, Violation demand KVa.
2. It should generate the reports related to motor efficiency whether the motors is working efficiently or not. It should generate the popups regarding the excess current consumption or if the motor is not working as per the stipulated efficiency.
3. It should generate the reports related to pump efficiency whether the pump is working efficiently or not. It should generate the popups regarding the pump efficiency If pump is not working as per the stipulated efficiency.
4. Also this system should provide the decision support mechanism so that proper decisions can be taken in terms of Power Quality, Demand Load, Energy Bill, Contract Load, Motor efficiency and Pump Efficiency etc and also it should be capable to integrate more feature as and when required in future.
5. Preventive maintenance of pump, motors and various instruments complete in all respects as per the entire satisfaction of Engineer-in-charge. | 1 | Each | - | - | itemH1Code2 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.31 MB
Form6.pdf
Tender Documents • 0.36 MB
Form8.pdf
Tender Documents • 1.19 MB
Terms.pdf
Tender Documents • 0.17 MB
BOQ_195443.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid