Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAdmitted-Finance 135 139 BILAKHIA HOUSE MUKTANANAD MARG CHALA VALSAD GUJARAT 396191 | VALSAD | GUJARAT | 396191 | L1 | Admitted-Finance | |
| 2 | L2₹8.7 L+₹2.6 L (42.1%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹14.8 L+₹8.7 L (142.3%)Admitted-Finance 10TH FLOOR VATIKA BUSINESS PARK BLOCK II SOHNA ROAD SECTOR 49 GURGAON HARYANA 122002 | GURGAON | GURGAON | HARYANA | 122002 | L3 | Admitted-Finance | |
| 4 | Rejected-Technical | - | Rejected-Technical reject |
| Sl No | Description | Qty | Unit | MSA Medical Devices L2 | STRYKER INDIA PRIVATE LTD L3 | MERIL HEALTHCARE PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|
| 1.00 | 1.UNCEMENTED THR
Metal On Poly | 1 | Each | - | - | - |
| 1.01 | a) The femoral Stem should have morphometric wedge geometry and HA coating, HA coating of 50-micron thick, Proximal body should be circumferentially plasma sprayed, Incremental Neck length options, two offset options minimum and made up of Ti6Al4V Material Collared and Collarless options, Reduced lateral shoulder taper, Wedge type. | 1 | Each | 27,325 ₹27,325 | 30,750 ₹30,750 | 23,000 ₹23,000 Lowest |
| 1.02 | b) The Acetabular Shell should utilize the Inner change Locking Mechanism. The acetabular shell should HA coated. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners. The acetabular shell should have 5 Hole option minimum starts from 52 shell size. The Acetabular Shell sizes should come in sizes from 38 to 64 mm with 2 mm of increment. | 1 | Each | 31,916 ₹31,916 | 21,574 ₹21,574 | 16,975 ₹16,975 Lowest |
| 1.03 | c) The Polyethylene has 10-degree posterior superior lip, neutral & 10 deg. The Polyethylene is compatible to accommodate 28mm, 32mm, and 36mm heads. | 1 | Each | 9,440 ₹9,440 | 6,345 ₹6,345 Lowest | 8,500 ₹8,500 |
| 1.04 | d) Femoral heads should be Metal Head with all sizes 28mm/32mm/36mm, compatible with ceramic short, medium, long, extralong. | 1 | Each | 10,620 ₹10,620 | 6,345 ₹6,345 Lowest | 9,500 ₹9,500 |
| 1.05 | Note:- All should be of Same Make | 1 | Each | - | - | - |
| 2.00 | UNCEMENTED THR
Ceramic On Poly | 1 | Each | - | - | - |
| 2.01 | a) The femoral Stem should have morphometric wedge geometry and HA coating, HA coating of 50-micron thick, Proximal body should be circumferentially plasma sprayed, Incremental Neck length options, two offset options minimum and made up of Ti6Al4V Material Collared and Collarless options, Reduced lateral shoulder taper, Wedge type | 1 | Each | 27,325 ₹27,325 | 30,750 ₹30,750 | 23,000 ₹23,000 Lowest |
| 2.02 | b) The Acetabular Shell should utilize the patented Inner change Locking Mechanism. The acetabular shell should HA coated. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners. The acetabular shell should have 5 Hole option minimum starts from 52 shell size. The Acetabular Shell sizes should come in sizes from 38 to 64 mm with 2 mm of increment | 1 | Each | 31,916 ₹31,916 | 21,574 ₹21,574 | 16,978 ₹16,978 Lowest |
| 2.03 | c) The Polyethylene has 10-degree posterior superior lip. The Polyethylene is compatible to accommodate 28mm, 32mm, and 36mm heads. | 1 | Each | 9,440 ₹9,440 | 6,345 ₹6,345 Lowest | 8,500 ₹8,500 |
Tender Value
₹1 Cr
EMD Value
₹2 L
Closing Date
16 Jul 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPDT. AND MEM. SEC. R.M.R.S. M.B.S. HOSPITAL KOTA
SUPDT. AND MEM. SEC. R.M.R.S. M.B.S. HOSPITAL KOTA
Regarding purchase of Implants for Orthoplasty in this hospital (Two Year rate contract)
2022_GMCK_276181_1
NITNO1-2022-23
Open Tender
Miscellaneous Goods
Item Rate
730 days
KOTA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
1000 SUPDT. AND MEM. SEC. RMRS M.B.S. HOS. KOTA
₹2 L
Yes
SUPDT. AND MEM. SEC. R.M.R.S. M.B.S. HOSPITAL KOTA
12 Aug 2022
29 May 2022
18 Jul 2022
29 May 2022
16 Jul 2022
3 Jun 2022
1 Jun 2022
Amount
1.UNCEMENTED THR Metal On Poly
a) The femoral Stem should have morphometric wedge geometry and HA coating, HA coating of 50-micron thick, Proximal body should be circumferentially plasma sprayed, Incremental Neck length options, two offset options minimum and made up of Ti6Al4V Material Collared and Collarless options, Reduced lateral shoulder taper, Wedge type.
b) The Acetabular Shell should utilize the Inner change Locking Mechanism. The acetabular shell should HA coated. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners. The acetabular shell should have 5 Hole option minimum starts from 52 shell size. The Acetabular Shell sizes should come in sizes from 38 to 64 mm with 2 mm of increment.
c) The Polyethylene has 10-degree posterior superior lip, neutral & 10 deg. The Polyethylene is compatible to accommodate 28mm, 32mm, and 36mm heads.
d) Femoral heads should be Metal Head with all sizes 28mm/32mm/36mm, compatible with ceramic short, medium, long, extralong.
Note:- All should be of Same Make
UNCEMENTED THR Ceramic On Poly
a) The femoral Stem should have morphometric wedge geometry and HA coating, HA coating of 50-micron thick, Proximal body should be circumferentially plasma sprayed, Incremental Neck length options, two offset options minimum and made up of Ti6Al4V Material Collared and Collarless options, Reduced lateral shoulder taper, Wedge type
b) The Acetabular Shell should utilize the patented Inner change Locking Mechanism. The acetabular shell should HA coated. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners. The acetabular shell should have 5 Hole option minimum starts from 52 shell size. The Acetabular Shell sizes should come in sizes from 38 to 64 mm with 2 mm of increment
c) The Polyethylene has 10-degree posterior superior lip. The Polyethylene is compatible to accommodate 28mm, 32mm, and 36mm heads.
d) Femoral heads should be Ceramic with all sizes 28mm/32mm/36mm compatible with ceramic short, medium, long, extralong.
Note:- All should be of Same Make
UNCEMENTED THR Ceramic On Ceramic
a) The femoral Stem should have morphometric wedge geometry and HA coating, HA coating should minimum of 50-micron thick, Proximal body should be circumferentially plasma sprayed, Incremental Neck length options, Two offset options minimum and made up of Ti6Al4V Material
b) The Acetabular Shell should utilize the patented Inner change Locking Mechanism. The acetabular shell should HA coated. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners. The acetabular shell should have 5 Hole option minimum starts from 52 shell size. The Acetabular Shell sizes should come in sizes from 44 to 62 mm
c) The Ceramic liner should have 0-degree posterior superior lip. The Ceramic liner should be compatible to accommodate 28mm, 32mm, and 36mm heads.
d) Femoral heads should be Ceramic with all sizes 28mm/32mm/36mm.
Note:- All should be of Same Make
CEMENTED THR Cemented THR
a) Cemented femoral stem should Highly polished, Double tapered with collarless design
b) The Cemented cup should have Ultra-High Molecular Weight Polyethylene with PMMA cement spacer easily identifiable the cup position on an X-ray. Cup Should be available in the I.D 28 /32 / 36 mm with OD 46 – 60 mm with two packets of bone cement.
Note:- All should be of Same Make
CEMENTED THR Revision THR a) Revision uncemented stem should be long and length should be between 180 - 380 mm, proximal part of Stem should be modular with cone body with HA Coated and distal part of stem should plasma sprayed.
Revision uncemented stem should be long and length should be between 180 - 380 mm, I. proximal part of Stem should be modular with cone body with HA Coated and distal part of stem should plasma sprayed. J. Revision uncemented acetabular shell have multi hole with min. 8 holes and HA Coated. Revision uncemented acetabular shell should provide dual mobility cup which composed of K. CoCr liner and highly crossed linked polyethylene which support 22- and 28-mm femoral metal head. L. Would also require acetabular wedges M. Acetabulam augments N. Acetabulam mesh. O. Uncemented acetabular shell especially designed for protrusion which is peripherally locking. P. Cancellous bone screws of 6.5 mm in length and 20 to 45 mm in diameter. O. Revision cemented stem should long and the length would more than 200 mm, with bone cements. P. cement spacer easily identifiable the cup position on an X-ray. Cup Should be available in the I.D 28 /32 / 36 mm with OD 46 – 60 mm. Q. The femoral Stem should have morphometric wedge geometry and HA coating, HA coating of 50-micron thick, Proximal body should be circumferentially plasma sprayed, Incremental Neck length options, two offset options minimum and made up of Ti6Al4V Material R. Femoral heads should be Metal Head with all sizes 22mm/28mm/32mm/36mm. S. The Polyethylene has 10-degree posterior superior lip. The Polyethylene is compatible to accommodate 28mm, 32mm, and 36mm heads. T. Femoral heads should be Ceramic with all sizes 28mm/32mm/36mm. Note:- All should be of Same Make
Cemented TKR
a) Primary Cemented TKR- PS consists of Femoral components, Tibial Baseplate, and highlycrossed linked polyethylene.
b) Primary cemented TKR Cruciate Retaining (CR) System
c) PCL Sacrificing/Posterior Stabilized Femoral Component with ability to accept augments both distally and posteriorly
d) Modular Tibial Component, Titanium alloy , various sizes with 1-3 degree posterior slope and ability to accept tibial extension stem/Rod various offset and sizes upto 150mm length.
e) Polyethylene tibial insert with good locking mechanism and option of both cruciate substituting and retaining.
f) Bone cement.
g) The Primary Prosthesis should have compatibility with a Revision Surgery implant
Note:- All should be of Same Make (CR/PS Implants Shold be of same make)
Revision cemented TKR should have following components
(a) Primary femoral components
(b) Tibial Baseplate compatible to stem extension
(c) Primary highly crossed linked polyethylene
(d) Bone Cement
(e) fluted Stem
Semi constraint TKR should have following components
(a) Femoral component compatible with stem extension
(b) Tibial Baseplate compatible to stem extension.
(c) Semi constrained highly cross-linked polyethylene.
(d) Distal Augments.
(e) Posteriar Augments
(f) Offset
(g) Fluted Stem
(h) Bone Cement
Total Hinge Knee system
All should be of Same Make
Reverse Shoulder Replacement Humeral Stem
a) Titanium with porous proximal plasma spray
b) Convertible from anatomic(total) shoulder to reverse
c) For use with or without Bone Cement
Mini Humeral Tray
a) Cobalt Chrome or Titanium
b) Height and Offset Options
Baseplates
a) Modular design with peripheral locking screw system
b) Mini and Augmented Baseplates
Mini Humeral Bearing
Glenosphere
a) Cobalt Chrome or Titanium with offset between 0.5 to 3.5 Screws
b) 6.5 mm Modular Compression Screw
Total Shoulder Replacement Cemented and Uncemented Complete Set
Hemi Shoulder Replacement NEER’s Prosthesis – Complete Set (Cemented and Uncemented)
Total Elbow Replacement Cemented and Uncemented Complete Set
Pulse lavage
Bone cement plain
Bone cement antibiotic
Saw blades
Disposable Item
a) Shoulder Drape
b)Gownankle level four
c) Cautery Pencil
d) Skin Stappler
e) Plain Sheet
f) Sofilam (Skin incision Drape)
g) Cling Drape
h) B/L knee o Drape
h) U-Drape
MSA Medical Devices
STRYKER INDIA PRIVATE LTD
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .