Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹53.5 L+₹2.2 L (4.23%)Rejected-AOC LEELA NIVAS GURUVAYUR | GURUVAYUR | KERALA | L2 | Rejected-AOC L2 | |
| 3 | L3₹55.8 L+₹4.5 L (8.84%)Rejected-AOC | L3 | Rejected-AOC l3 | |
| 4 | L4₹56.8 L+₹5.5 L (10.8%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹58.4 L+₹7.1 L (13.9%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹66.9 L
EMD Value
₹50,000
Closing Date
11 May 2023, 2:00 pmClosed
Executive Engineer
KWA, PH Division, Kottarakkara
DEPOSIT-Jilla Panchayath-Extension of pipe line at Urukunnu area.
2023_KWA_574462_1
WRD/KWA-CE(SR)/TR/5757/8
Open Tender
Civil Works - Water Works
Item Rate
150 days
Punalur Municipality - Urukunnu area
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,760
₹50,000
16 Jun 2023
3 May 2023
12 May 2023
3 May 2023
11 May 2023
3 May 2023
Amount
Pipeline work
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
100.9.7:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes.
100.98.224:Supply of PVC Pipe, 8kg/cm2, 110mm Dia.
100.98.223:Supply of PVC Pipe, 8kg/cm2, 90mm Dia.
100.98.222:Supply of PVC Pipe, 8kg/cm2, 75mm Dia.
100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.
100.98.460:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
100.98.458:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
18.12.6:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore
18.12.7:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore
18.12.8:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore
OD249532/2022-2023:Interconnection work from the newly laid line to the existing lines
OD249538/2022-2023:Shifting house connection from existing PVC mains using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, Lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges but and excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.32.3:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 50mm Double Acting Air Valve.
100.98.449:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 50mm.
Gallery and well cleaning
OD251100/2022-2023:Well cleaning including desilting, Gallery cleaning, connecting new perforated pipes to the existing well, adding new filter media, rubble packing, etc for increased flow to the intake well and repair works to pump house and existing GL tank at Urukunnu.
Anilkumar
VARGHESE CHACKO
Reji Mathew
NAZARUDEEN
RAJEEVKUMAR B
Bidder Name
NAZARUDEEN
N.Sunderlal
Anilkumar
VARGHESE CHACKO
RAJEEVKUMAR B
Reji Mathew
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_848070.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .