Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.2 Cr+₹79,479 (0.68%)Rejected-Finance GOKUL APARTMENT PANJABIPARA DISTT JALPAIGURI SILIGURI 734401 WB | DARJEELING | WEST BENGAL | 734401 | ₹1.2 Cr+₹79,479 (0.68%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹1.2 Cr+₹84,450 (0.72%)Rejected-Finance BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹1.2 Cr+₹84,450 (0.72%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹1.2 Cr+₹84,852 (0.72%)Rejected-Finance POST BOX NO 86 VALLIMA COTTAGE 4 7 HOOKER ROAD POST DIST DARJEELING PIN 734101 | DARJEELING | WEST BENGAL | 734101 | ₹1.2 Cr+₹84,852 (0.72%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹1.2 Cr+₹2.3 L (1.96%)Rejected-Finance | ₹1.2 Cr+₹2.3 L (1.96%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | S.N. GHOSH AND CO. L1 | M/s Debendra Prasad Gupta L5 | M/S JAGDISH PRASAD AGARWALA L3 | ANIL ENGINEERING CO L2 | M/S JYOTI SHARMA AND SONS L4 | KAMALA INDUSTRIES L6 | bholanath bera L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-in-charge. | 7 | CUM | 500 ₹3,500 | 450 ₹3,150 | 500 ₹3,500 | 50 ₹350 Lowest | 325 ₹2,275 | 800 ₹5,600 | 560 ₹3,920 |
| 2.00 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge. | 48 | EACH | 120 ₹5,760 | 140 ₹6,720 | 125 ₹6,000 | 50 ₹2,400 Lowest | 50 ₹2,400 Lowest | 200 ₹9,600 | 150 ₹7,200 |
| 3.00 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge.
(Note - Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkats and making good the damaged surfaces). | 84 | EACH | 200 ₹16,800 | 160 ₹13,440 | 150 ₹12,600 | 50 ₹4,200 Lowest | 75 ₹6,300 | 200 ₹16,800 | 200 ₹16,800 |
| 4.00 | Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each, complete all as per specified and as directed by Engineer-in-charge. | 30 | PER LEAF | 110 ₹3,300 | 70 ₹2,100 | 75 ₹2,250 | 50 ₹1,500 Lowest | 90 ₹2,700 | 150 ₹4,500 | 50 ₹1,500 Lowest |
| 5.00 | Refixing shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each in same opening after easing etc., complete all as per specified and as directed by Engineer-in-charge. | 30 | PER LEAF | 225 ₹6,750 | 180 ₹5,400 | 75 ₹2,250 | 50 ₹1,500 Lowest | 100 ₹3,000 | 150 ₹4,500 | 100 ₹3,000 |
| 6.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed by Engineer-in-charge. | 5 | QNTL | 450 ₹2,250 | 350 ₹1,750 | 200 ₹1,000 | 20 ₹100 Lowest | 2,500 ₹12,500 | 1,000 ₹5,000 | 300 ₹1,500 |
| 7.00 | Taking down cement plaster on brick wall of any description, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-charge. | 3,350 | SQM | 20 ₹67,000 | 21 ₹70,350 | 25 ₹83,750 | 10 ₹33,500 Lowest | 40 ₹1,34,000 | 35 ₹1,17,250 | 30 ₹1,00,500 |
| 8.00 | Demolition of unreinforced cement concrete in ground floors and paving's n exc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge. | 25 | CUM | 500 ₹12,500 | 700 ₹17,500 | 500 ₹12,500 | 50 ₹1,250 Lowest | 400 ₹10,000 | 800 ₹20,000 | 650 ₹16,250 |
| 9.00 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed by Engineer-in-charge. | 2.7 | CUM | 950 ₹2,565 | 1,500 ₹4,050 | 600 ₹1,620 | 50 ₹135 Lowest | 450 ₹1,215 | 800 ₹2,160 | 850 ₹2,295 |
| 10.00 | Roughening the surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg of cement per Sqm, complete all as specified and directed by Engineer-in-Charge. | 1,411 | SQM | 20 ₹28,220 Lowest | 45 ₹63,495 | 25 ₹35,275 | 70 ₹98,770 | 75 ₹1,05,825 | 20 ₹28,220 Lowest | 60 ₹84,660 |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
22 Dec 2025, 6:00 pmClosed
CWE BINNAGURI
HQ CWE BINNAGURI, BINNAGURI CANTT, JALPAIGURI, WEST BENGAL, PIN-735232
SPECIAL REPAIRS TO MD ANCCN BLDG NO 2/R/11 AT MANOJ PANDEY VIHAR AT BINNAGURI MIL STN UNDER GE NORTH BINNAGURI
2025_MES_741313_1
8298/E8
Open Tender
Civil Works
Item Rate
270 days
GE NORTH BINNAGURI
AS PER NIT
8 documents required · 8 mandatory
₹1,000
GE (N) BINNAGURI
₹2.2 L
Yes
19 Feb 2026
24 Nov 2025
23 Dec 2025
24 Nov 2025
22 Dec 2025
15 Dec 2025
Taking down cement plaster on brick wall of any description, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-charge.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed by Engineer-in-charge.
Roughening the surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg of cement per Sqm, complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as per specified and as directed by Engineer-in-charge.
POINT
Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 20 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC (1:2:4) type B1 (20mm graded aggregate) as in roof kerbs, slightly rounded or chamfered on edges, finished even and smooth on exposed concrete surface without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for RCC 1:1.5:3, type A1 (20mm graded stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as per specified and as directed by Engineer-in-charge.
S&F of Pressed steel frames of size 105x60 mm and thickness of sheet 1.2mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as per specified and as directed by Engineer-in-charge.
S&F of 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge.
S&F of framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde-E-165, complete all as per specified and as directed by Engineer-in-charge.
S&F of 100 mm butt hinges stainless steel, complete all as per specified and as directed by Engineer-in-charge.
S&F 150 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F of 150 mm extruded aluminium alloy handles, fabricated type, anodised complete all as per specified and as directed by Engineer-in-charge.
S&F of 250 mm long mild aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as per specified and as directed by Engineer-in-charge.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as per specified and as directed by Engineer-in-charge.
M&L for Cutting holes into or through brick/ stone masonry walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregates) as required superficial area exc 150 Sq. cm and not exc 400 Sq. cm etc., complete all as specified and as directed by Engineer-in-charge.
Taking down tarfelt with cement plaster/PCC any thickness from roof surfaces and lowering and removing the same to a distance exceeding 500 m and not exc. 900 m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc, complete all as specified and as directed by Engineer-in-charge.
S&F of coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge.
S&F of coloured non-skid ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge.
Dismantling ballies, hard or soft wood, any position, except in posts and struts; including taking out iron straps, bolts and nuts, etc., if any complete all as per specified and as directed by Engineer-in-charge.
M&L for 10mm thick rendering in cm(1:4) on fair faces of brick work or concrete surfaces as backing coat of dado/skirting etc., complete all as specified and as directed by Engineer-in-charge.
M&L for coloured glazed ceramic tiles 350x 250x 7 mm/ 450X 350X 7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over, complete all as specified and as directed by Engineer-in-charge.
M&L for 18- 20mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing with 10 mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC @ 200ml/ 50Kg of cement in order to maintain proper slope over existing roof surfaces for laying water proofing treatment over roof, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge. (Note: Water proofing compound shall be measured and paid separately under relevant item of this schedule).
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 including mixing WPC @ 200ml/ 50Kg of cement, surface even & smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge. (Note: Water proofing compound shall be measured and paid separately under relevant item of this schedule).
M&L for 15 mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces and finished the surface even & fair without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for 5mm thick rendering plastering on fair faces of brick work or concrete surface in cement mortar (1:3) and surface even and fair without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 2 coats of cement based wall care putty 1 mm each to wall surface, complete all as specified and as directed by Engineer-in-charge.
M&L for complete removal of existing treatment of old plastered surfaces of walls and applying two coats of Acrylic based distemper over a coat of primer after applying 2 coat of cement based wall care putty 1 mm each including complete removal of existing treatment, complete all as specified and as directed by Engineer-in-charge.
M&L for waterproofing Coating with polyurethane based water proofing liquid membrane of approved make to be applied by brush with multi coats with minimum dry film thickness of 1mm and shall be cured by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane, complete all as specified and as directed by Engineer-in-charge. Note: the above treatment will be carried out by authorised applicator of approved firm/company.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge.
M&L for preparing old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and as directed by Engineer-in-charge.
M&L for 18 to 20 mm thick granite (of any t
ype) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite stone including griding & polishing with 15 mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
S&F of 15 mm bore steel water tubes medium grade galvanised with all fittings/ fixed complete to walls and ceilings or laid in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F of GI tube 20 mm bore medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge.
S&F of PVC (SWR) 75 mm bore bends complete all as per specified and as directed by Engineer-in-charge.
S&F of 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge.
S&F of 75 mm dia PVC (SWR) branch piece single (single 'Y') equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge.
S&F of Pressed steel frames of size 125x60 mm and thickness of sheet 1.2mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of wood and wood based materials of any description, not otherwise described and applying one coat of synthetic enamel paint over 10 cm width or girth, complete all as per specified and as directed by Engineer-in-charge.
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings, beams, slab, staircase, chajjas and similar work, (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as per specified and as directed by Engineer-in-charge.
S&F of Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
Material & Labour for preparing of new plastered surface of wall and applying finishing walls with Acrylic Smooth exterior paint of required shade : New work Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed by Engineer-in-charge.
Material & Labour for complete removal of existing treatment finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed by Engineer-in-charge.
S&F of roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat se
ctions) including distance pieces, cleats etc. Confirming to Fe 410-W (Gde E- 250) quality-A, complete all as per specified and as directed by Engineer-in-charge.
S&F of 125 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of PVC valveless, symphonic action type 10 litre capacity low level flushing cistern, white, with inlet, ball valve, float and handle including brackets and 32 mm bore PVC flush pipe, complete all as per specified and as directed by Engineer-in-charge.
S&F of 125 mm long aluminium handles, cast type, anodised, complete all as per specified and as directed by Engineer-in-charge.
S&F of harrison rails curtain rod, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of providing & fixing factory made solid PVC cup board shutter (Flush type) of 24 mm thick made from co-extruded 3 layer rigid PVC foam sheet (single extruded) with density not less than 600kg/cum outer layer (.8-1mm) thick should be of rigid PVC with density of not less than 1400kg/cum manufactured by an ISO 9001-2015 certified company. Door should be water proof, termite proof, fire retardant and having good screw holding capacity, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of providing and fixing factory made PVC shelf/ partition of required size consisting of 20mm thick Solid PVC Sandwich Panel with 1mm Plain PVC Sheet on both sides suitably fixed in M.S. angle frame work as per specification & drawing, complete all as per specified and as directed by Engineer-in-charge.
S&F of 75 mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard & railing 60 cm long, complete all as per specified and as directed by Engineer-in-charge.
S&F of 75 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F of Powder coated aluminium window sliding type three track (2 glazed & one gauze shutter ) aluminium sections weighing not less than 1.25kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing , screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surface of wall, complete all as per specified and as directed by Engineer-in-charge.
S&F of Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide, primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge.
M&L for 75mm thick cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in path/plinth protection & paving finished even & fair without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 40 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length, complete all as specified and as directed by Engineer-in-charge. Note: (a) M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately. (b) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
M&L for water proofing treatment to sunken floor complete all as specified and as directed by Engineer-in-charge. Note:- For Method refer PS in sunken floor treatment.
S&F of Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing but 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, complete all as per specified and as directed by Engineer-in-charge
M&L for Mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully old unserviceable copper/ aluminium point wiring (light, exhaust fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, bells, sockets, tube light fittings etc., and making good disturbed surface of walls & Floors etc., complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, modular type sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes duly painted with aluminium inside and anticorrosive paint outside, concealed in walls, with modular frame for housing modular type switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles. Where concealing of conduit is not feasible i.e. on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost complete all as specified and as directed for one light point controlled by one way switch, complete all as per specified and as directed by Engineer-in-Charge.
All as per serial item No. 129 as above but for one ceiling/exhaust fan point controlled by one switch, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 129 as above but for one socket outlet 5/6 AMPs on independent board, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 129 as above but for one socket outlet 5/6 AMPs on same board, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 129 as above but for one Bell point controlled by one switch, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 129 as above but for one light point controlled by two way switch, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 129 as above but with 2.5 sqmm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular switch, single pole, one way, 6/10 Amp, 1 Module, 230 volt, ISI marked, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular switch, single pole, Two way, 6/10 Amp, 1 Module, 230 volt, ISI marked, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular Switch single pole, one way, 16/20 Amps, 1 module, 230 volts, ISI marked, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular shutter socket outlet 5 pin, 6/10 Amps, 2 module, 230 volts, ISI marked, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular shutter socket outlet 6 pin, 6/16 Amps, 2 module, 230 volts, ISI marked, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular Bell push 6/10 Amp, 1 Module, 230 volt, ISI marked, complete all as specified and as directed by Engineer-in-charge.
S&F of modular electronic step regulator (speed regulation in 5 steps) 120W - 2 module suitable for ceiling fan 1200 sweep/1400 mm, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including 9 watts LED light complete all as specified and as directed by Engin
eer-in-charge.
S&F of ceiling rose surface PVC three terminals, PVC/polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair of 20W inverter LED batten with square profile and polycarbonate channel, including lithium-ion battery with a charging time of 8–10 hours and a backup time of up to 4 hours, complete with driver and holder. The LED tube light shall be connected using three-core flexible copper conductor cable from the ceiling rose to the tube light fitting, complete in all respects as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair of LED lights fitting 1x 18 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-charge.
S&F in repair of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F of Decorative wall light fixture made up of polycarbonate suitable for 15 watt LED retrofit of type B-22 base, IP66 grade with and including 15 watt LED ( or nearest next higher wattage ) lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor to terminal block of light fitting including necessary taking down the old unserviceable fitting , complete all as specified and as directed by Engineer-in-charge.
S&F in repair of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed by Engineer-in-charge.
Refixing of only LED Tube light of any watt on wall/surface mounted fixed with 02 Nos of PVC round/ square blocks, screws etc complete all as specified and as directed by Engineer-in-charge.
Taking down carefully Ceiling fan from its original position and refixing / hanging after plaster work including painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc, complete all as specified and as directed by Engineer-in-charge.
M&L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc , complete all as specified and as directed by Engineer-in-charge.
Taking down carefully exhaust fan from its original position / hanging after B/R plaster work complete all as specified and as directed by Engineer-in-charge.
Material and labour for concealed sub-main wiring along with earth wire of size of 4 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc including taking down of old unserviceable complete all as specified and as directed by Engineer-in-charge. NOTE : Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
Supply and fixing of sheet metal enclosure powder painted for MCB TP & N 4 way double door DB, 415 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down of old unserviceable complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of sheet metal enclosure powder painted for MCB SPN 8 way double door DB, 240 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down of old unserviceable complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of 415V 10KA 'C' curve miniature circuit breaker (MCB) of triple poles neutral 63 Amps and current carrying capacity in the DB including taking down of old unserviceable complete all as specified and as directed by Engineer-in-charge.
M&L for providing & fixing factory made solid PVC cup board frame of size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5 mm thick prelam/plain colour PVC sheet reinforce with 19mm x 19mm MS square tube of 19 gauge thickness throughout the frame and metre cut at two corners and jointed with 2 no's of 150mm long brackets of 15mm x 15mm MS square tubes. The door frame shall be fixed to the wall using 100mm long MS screws through the frame by using PVC fasteners. A minimum 4 no's of screws to be provided for each vertical member and minimum 2 no's of screws to be provided to the horizontal member etc., complete all as per specified and as directed by Engineer-in-charge.
Supply and fixing of amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down of old unserviceable complete all as specified and as directed by Engineer-in-charge.
S&F of Powder coated aluminium louvered ventilators of size n exc 0.50 Sqm area with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazing cleats, rubber packing , anodised aluminium snap beading, screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangements including taking down of old existing steel ventilator and making good disturbed surfaces of wall complete all as per specified and as directed by Engineer-in-charge.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
BOQ_830083.xls
BOQ • 0.42 MB
8298TENDERDOCUEMTNS.pdf
Tender Documents • 1.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .