Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance A36 B14 H BLOCK MIDC ESTATE PIMPRI PUNE 411018 PUNE MAHARASHTRA 411018 | PUNE | MAHARASHTRA | 411018 | Admitted-Finance |
| 3 | Admitted-Finance 9TH 915 A UNITECH ARCADIA SOUTH CITY II SECTOR 49 UNITECH ARCADIA SOUTH CITY II GURGAON HARYANA 122018 | GURUGRAM | HARYANA | 122018 | Admitted-Finance |
| 4 | Admitted-Finance PLOT NO 1 GAT NO 181 VEGA INDIA LEVEL AND PRESSURE MEASUREMENT PVT LTD VILLAGE FULGOAN TAL HAVELI FULGOAN | Admitted-Finance |
| 5 | Rejected-Technical S 18 M I D C BHOSARI BHOSARI PUNE MAHARASHTRA 411026 | PUNE | MAHARASHTRA | 411026 | Rejected-Technical Technically not acceptable |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
11 Jan 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SREEKANTH S
PD ADMINISTRATIVE BUILDING, UDYOGAMANDAL, FACT
Guided Wave Radar Transmitter
2020_FACT_600320_1
MM/172/E22536
Open Tender
Miscellaneous Goods
Supply
UDYOGAMANDAL
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹45,000
Yes
11 Aug 2021
2 Dec 2020
12 Jan 2021
2 Dec 2020
11 Jan 2021
2 Dec 2020
120 days
Guided Wave Radar transmitter for continuous Liquid Level measurement. Mounting type : Flanged, External chamber top mounted. Electronics : Supply 24V DC; 4-20 mA DC, Two wire Output with HART. Local Display : Required, LCD/LED type. Cable entry : 1/2” NPTF Accuracy/Repeatability : ±4 mm or better / ±2 mm or better Enclosure : Weather proof to IP65 or better, Ex-proof - Exd II A & IIB, T4 or better. Ambient Temperature : 0 to 50°C Process connection : Flanged, 2” ANSI 300#RF. Probe Type : Rigid single lead, Dia. between 8 to 16 mm; Shortenable & Exchangeable at field. Material of probe/wetted parts : SS316L Material of process flange : SS316L Housing material : Aluminum alloy, Polyurethane coated or suitable industrial grade painting. Process seal & other materials : Vendor to specify to match with service fluid, pressure & Temp. External chamber : 3”; Material - CS/SS; Smooth surface with two process tapping dia 1” each; Distance from 100% level to inst. mounting Flange: 250 mm and from 0% level to bottom of chamber: 25 mm. Centring disc/spacer : Required,1 nos, suitable for 3” chamber; Material: Teflon or suitable for the process. Special functions : Diagnostic facility, Integrated data memory, Reliable measuring in case of moved surface, foam, vapour, steam, build-up or condensation, Instruments shall be field changeable to other fluids and the electronics parts shall be replaceable type. Probe /measurement length : 1676/1226 mm Fluid : Cooling Water Process conditions: a. Operating Pressure : 1.0 Kg/cm2A b. Maximum Pressure : 32 Kg/cm2A c. Vacuum Conditions : NA d. Operating Temperature : 35 °C e. Maximum Temperature : 120 °C f. Foam present or absent : NA g. Vapour present or absent : NIL.
Guided Wave Radar transmitter for continuous Liquid Level measurement. Mounting type : Flanged, External chamber top mounted. Electronics : Supply 24V DC; 4-20 mA DC, Two wire Output with HART. Local Display : Required, LCD/LED type. Cable entry : 1/2” NPTF Accuracy/Repeatability : ±4 mm or better / ±2 mm or better Enclosure : Weather proof to IP65 or better, Ex-proof - Exd II A & IIB, T4 or better. Ambient Temperature : 0 to 50°C Process connection : Flanged, 2” ANSI 300#RF. Probe Type : Rigid single lead, Dia. between 8 to 16 mm; Shortenable & Exchangeable at field. Material of probe/wetted parts : SS316L Material of process flange : SS316L Housing material : Aluminum alloy, Polyurethane coated or suitable industrial grade painting. Process seal & other materials : Vendor to specify to match with service fluid, pressure & Temp. External chamber : 3”; Material - CS/SS; Smooth surface with two process tapping dia 1” each; Distance from 100% level to inst. mounting Flange: 250 mm and from 0% level to bottom of chamber: 25 mm. Centring disc/spacer : Required,1 nos, suitable for 3” chamber; Material: Teflon or suitable for the process. Special functions : Diagnostic facility, Integrated data memory, Reliable measuring in case of moved surface, foam, vapour, steam, build-up or condensation, Instruments shall be field changeable to other fluids and the electronics parts shall be replaceable type. Probe /measurement length : 1676/1226 mm Fluid : Cooling Water Process conditions: a. Operating Pressure : 1.0 Kg/cm2A b. Maximum Pressure : 32 Kg/cm2A c. Vacuum Conditions : NA d. Operating Temperature : 35 °C e. Maximum Temperature : 120 °C f. Foam present or absent : NA g. Vapour present or absent : NIL.
Guided Wave Radar transmitter for continuous Liquid Level measurement. Mounting type : Flanged, External chamber top mounted. Electronics : Supply 24V DC; 4-20 mA DC, Two wire Output with HART. Local Display : Required, LCD/LED type. Cable entry : 1/2” NPTF Accuracy/Repeatability : ±4 mm or better / ±2 mm or better Enclosure : Weather proof to IP65 or better, Ex-proof - Exd II A & IIB, T4 or better. Ambient Temperature : 0 to 50°C Process connection : Flanged, 2” ANSI 300#RF. Probe Type : Rigid single lead, Dia. between 8 to 16 mm; Shortenable & Exchangeable at field. Material of probe/wetted parts : SS316L Material of process flange : SS316L Housing material : Aluminum alloy, Polyurethane coated or suitable industrial grade painting. Process seal & other materials : Vendor to specify to match with service fluid, pressure & Temp. External chamber : 3”; Material - CS/SS; Smooth surface with two process tapping dia 1” each; Distance from 100% level to inst. mounting Flange: 250 mm and from 0% level to bottom of chamber: 25 mm. Centring disc/spacer : Required,1 nos, suitable for 3” chamber; Material: Teflon or suitable for the process. Special functions : Diagnostic facility, Integrated data memory, Reliable measuring in case of moved surface, foam, vapour, steam, build-up or condensation, Instruments shall be field changeable to other fluids and the electronics parts shall be replaceable type. Probe /measurement length : 1974/1524 mm Fluid : Ammonia water Process conditions: a. Operating Pressure : 3 Kg/cm2A b. Maximum Pressure : 32 Kg/cm2A c. Vacuum Conditions : NA d. Operating Temperature : 65 °C e. Maximum Temperature : 120 °C f. Foam present or absent : NA g. Vapour present or absent : Present.
Guided Wave Radar transmitter for continuous Liquid Level measurement. Mounting type : Flanged, External chamber top mounted. Electronics : Supply 24V DC; 4-20 mA DC, Two wire Output with HART. Local Display : Required, LCD/LED type. Cable entry : 1/2” NPTF Accuracy/Repeatability : ±4 mm or better / ±2 mm or better Enclosure : Weather proof to IP65 or better, Ex-proof - Exd II A & IIB, T4 or better. Ambient Temperature : 0 to 50°C Process connection : Flanged, 2” ANSI 300#RF. Probe Type : Rigid single lead, Dia. between 8 to 16 mm; Shortenable & Exchangeable at field. Material of probe/wetted parts : SS316L Material of process flange : SS316L Housing material : Aluminum alloy, Polyurethane coated or suitable industrial grade painting. Process seal & other materials : Vendor to specify to match with service fluid, pressure & Temp. External chamber : 3”; Material - CS/SS; Smooth surface with two process tapping dia 1” each; Distance from 100% level to inst. mounting Flange: 250 mm and from 0% level to bottom of chamber: 25 mm. Centring disc/spacer : Required,1 nos, suitable for 3” chamber; Material: Teflon or suitable for the process. Special functions : Diagnostic facility, Integrated data memory, Reliable measuring in case of moved surface, foam, vapour, steam, build-up or condensation, Instruments shall be field changeable to other fluids and the electronics parts shall be replaceable type. Probe /measurement length : 1263/813 mm Fluid : Ammonium Carbonate solution Process conditions: a. Operating Pressure : 3.5 Kg/cm2A b. Maximum Pressure : 32 Kg/cm2A c. Vacuum Conditions : NA d. Operating Temperature : 60 °C e. Maximum Temperature : 120 °C f. Foam present or absent : NA g. Vapour present or absent : Present.
Guided Wave Radar transmitter for continuous Liquid Level measurement. Mounting type : Flanged, External chamber top mounted. Electronics : Supply 24V DC; 4-20 mA DC, Two wire Output with HART. Local Display : Required, LCD/LED type. Cable entry : 1/2” NPTF Accuracy/Repeatability : ±4 mm or better / ±2 mm or better Enclosure : Weather proof to IP65 or better, Ex-proof - Exd II A & IIB, T4 or better. Ambient Temperature : 0 to 50°C Process connection : Flanged, 2” ANSI 300#RF. Probe Type : Rigid single lead, Dia. between 8 to 16 mm; Shortenable & Exchangeable at field. Material of probe/wetted parts : SS316L Material of process flange : SS316L Housing material : Aluminum alloy, Polyurethane coated or suitable industrial grade painting. Process seal & other materials : Vendor to specify to match with service fluid, pressure & Temp. External chamber : 3”; Material - CS/SS; Smooth surface with two process tapping dia 1” each; Distance from 100% level to inst. mounting Flange: 250 mm and from 0% level to bottom of chamber: 25 mm. Centring disc/spacer : Required,1 nos, suitable for 3” chamber; Material: Teflon or suitable for the process. Special functions : Diagnostic facility, Integrated data memory, Reliable measuring in case of moved surface, foam, vapour, steam, build-up or condensation, Instruments shall be field changeable to other fluids and the electronics parts shall be replaceable type. Probe /measurement length : 1263/813 mm Fluid : Nitric Acid (Diluted) Process conditions: a. Operating Pressure : 2.0 Kg/cm2A b. Maximum Pressure : 32 Kg/cm2A c. Vacuum Conditions : NA d. Operating Temperature : 45 °C e. Maximum Temperature : 120 °C f. Foam present or absent : NA g. Vapour present or absent : Present.
Guided Wave Radar transmitter for continuous Liquid Level measurement. Mounting type : Flanged, External chamber top mounted. Electronics : Supply 24V DC; 4-20 mA DC, Two wire Output with HART. Local Display : Required, LCD/LED type. Cable entry : 1/2” NPTF Accuracy/Repeatability : ±4 mm or better / ±2 mm or better Enclosure : Weather proof to IP65 or better, Ex-proof - Exd II A & IIB, T4 or better. Ambient Temperature : 0 to 50°C Process connection : Flanged, 2” ANSI 300#RF. Probe Type : Rigid single lead, Dia. between 8 to 16 mm; Shortenable & Exchangeable at field. Material of probe/wetted parts : SS316L Material of process flange : SS316L Housing material : Aluminum alloy, Polyurethane coated or suitable industrial grade painting. Process seal & other materials : Vendor to specify to match with service fluid, pressure & Temp. External chamber : 3”; Material - CS/SS; Smooth surface with two process tapping dia 1” each; Distance from 100% level to inst. mounting Flange: 250 mm and from 0% level to bottom of chamber: 25 mm. Centring disc/spacer : Required,1 nos, suitable for 3” chamber; Material: Teflon or suitable for the process. Special functions : Diagnostic facility, Integrated data memory, Reliable measuring in case of moved surface, foam, vapour, steam, build-up or condensation, Instruments shall be field changeable to other fluids and the electronics parts shall be replaceable type. Probe /measurement length : 1263/813 mm Fluid : Nitric Acid (Diluted) Process conditions: a. Operating Pressure : 2.0 Kg/cm2A b. Maximum Pressure : 32 Kg/cm2A c. Vacuum Conditions : NA d. Operating Temperature : 45 °C e. Maximum Temperature : 120 °C f. Foam present or absent : NA g. Vapour present or absent : Present.
Guided Wave Radar transmitter for continuous Liquid Level measurement. Mounting type : Flanged, External chamber top mounted. Electronics : Supply 24V DC; 4-20 mA DC, Two wire Output with HART. Local Display : Required, LCD/LED type. Cable entry : 1/2” NPTF Accuracy/Repeatability : ±4 mm or better / ±2 mm or better Enclosure : Weather proof to IP65 or better, Ex-proof - Exd II A & IIB, T4 or better. Ambient Temperature : 0 to 50°C Process connection : Flanged, 2” ANSI 300#RF. Probe Type : Rigid single lead, Dia. between 8 to 16 mm; Shortenable & Exchangeable at field. Material of probe/wetted parts : SS316L Material of process flange : SS316L Housing material : Aluminum alloy, Polyurethane coated or suitable industrial grade painting. Process seal & other materials : Vendor to specify to match with service fluid, pressure & Temp. External chamber : 3”; Material - CS/SS; Smooth surface with two process tapping dia 1” each; Distance from 100% level to inst. mounting Flange: 250 mm and from 0% level to bottom of chamber: 25 mm. Centring disc/spacer : Required,1 nos, suitable for 3” chamber; Material: Teflon or suitable for the process. Special functions : Diagnostic facility, Integrated data memory, Reliable measuring in case of moved surface, foam, vapour, steam, build-up or condensation, Instruments shall be field changeable to other fluids and the electronics parts shall be replaceable type. Probe /measurement length : 1669/1219 mm Fluid : Liquid Ammonia Process conditions: a. Operating Pressure : 23.0 Kg/cm2A b. Maximum Pressure : 32 Kg/cm2A c. Vacuum Conditions : NA d. Operating Temperature : -12 °C e. Maximum Temperature : 120 °C f. Foam present or absent : NA g. Vapour present or absent : Present.
Guided Wave Radar transmitter for continuous Liquid Level measurement. Mounting type : Flanged, External chamber top mounted. Electronics : Supply 24V DC; 4-20 mA DC, Two wire Output with HART. Local Display : Required, LCD/LED type. Cable entry : 1/2” NPTF Accuracy/Repeatability : ±4 mm or better / ±2 mm or better Enclosure : Weather proof to IP65 or better, Ex-proof - Exd II A & IIB, T4 or better. Ambient Temperature : 0 to 50°C Process connection : Flanged, 2” ANSI 300#RF. Probe Type : Rigid single lead, Dia. between 8 to 16 mm; Shortenable & Exchangeable at field. Material of probe/wetted parts : SS316L Material of process flange : SS316L Housing material : Aluminum alloy, Polyurethane coated or suitable industrial grade painting. Process seal & other materials : Vendor to specify to match with service fluid, pressure & Temp. External chamber : 3”; Material - CS/SS; Smooth surface with two process tapping dia 1” each; Distance from 100% level to inst. mounting Flange: 250 mm and from 0% level to bottom of chamber: 25 mm. Centring disc/spacer : Required,1 nos, suitable for 3” chamber; Material: Teflon or suitable for the process. Special functions : Diagnostic facility, Integrated data memory, Reliable measuring in case of moved surface, foam, vapour, steam, build-up or condensation, Instruments shall be field changeable to other fluids and the electronics parts shall be replaceable type. Probe /measurement length : 1263/813 mm Fluid : Liquid Ammonia Process conditions: a. Operating Pressure : 23.0 Kg/cm2A b. Maximum Pressure : 32 Kg/cm2A c. Vacuum Conditions : NA d. Operating Temperature : -12 °C e. Maximum Temperature : 120 °C f. Foam present or absent : NA g. Vapour present or absent : Present.
Guided Wave Radar transmitter for continuous Liquid Level measurement. Mounting type : Flanged, External chamber top mounted. Electronics : Supply 24V DC; 4-20 mA DC, Two wire Output with HART. Local Display : Required, LCD/LED type. Cable entry : 1/2” NPTF Accuracy/Repeatability : ±4 mm or better / ±2 mm or better Enclosure : Weather proof to IP65 or better, Ex-proof - Exd II A & IIB, T4 or better. Ambient Temperature : 0 to 50°C Process connection : Flanged, 2” ANSI 300#RF. Probe Type : Rigid single lead, Dia. between 8 to 16 mm; Shortenable & Exchangeable at field. Material of probe/wetted parts : SS316L Material of process flange : SS316L Housing material : Aluminum alloy, Polyurethane coated or suitable industrial grade painting. Process seal & other materials : Vendor to specify to match with service fluid, pressure & Temp. External chamber : 3”; Material - CS/SS; Smooth surface with two process tapping dia 1” each; Distance from 100% level to inst. mounting Flange: 250 mm and from 0% level to bottom of chamber: 25 mm. Centring disc/spacer : Required,1 nos, suitable for 3” chamber; Material: Teflon or suitable for the process. Special functions : Diagnostic facility, Integrated data memory, Reliable measuring in case of moved surface, foam, vapour, steam, build-up or condensation, Instruments shall be field changeable to other fluids and the electronics parts shall be replaceable type. Probe /measurement length : 1263/813 mm Fluid : Liquid Benzene Process conditions: a. Operating Pressure : 2.0 Kg/cm2A b. Maximum Pressure : 32 Kg/cm2A c. Vacuum Conditions : NA d. Operating Temperature : 82 °C e. Maximum Temperature : 120 °C f. Foam present or absent : NA g. Vapour present or absent : Present.
Guided Wave Radar transmitter for continuous Liquid Level measurement. Mounting type : Flanged, External chamber top mounted. Electronics : Supply 24V DC; 4-20 mA DC, Two wire Output with HART. Local Display : Required, LCD/LED type. Cable entry : 1/2” NPTF Accuracy/Repeatability : ±4 mm or better / ±2 mm or better Enclosure : Weather proof to IP65 or better, Ex-proof - Exd II A & IIB, T4 or better. Ambient Temperature : 0 to 50°C Process connection : Flanged, 2” ANSI 300#RF. Probe Type : Rigid single lead, Dia. between 8 to 16 mm; Shortenable & Exchangeable at field. Material of probe/wetted parts : SS316L Material of process flange : SS316L Housing material : Aluminum alloy, Polyurethane coated or suitable industrial grade painting. Process seal & other materials : Vendor to specify to match with service fluid, pressure & Temp. External chamber : 3”; Material - CS/SS; Smooth surface with two process tapping dia 1” each; Distance from 100% level to inst. mounting Flange: 250 mm and from 0% level to bottom of chamber: 25 mm. Centring disc/spacer : Required,1 nos, suitable for 3” chamber; Material: Teflon or suitable for the process. Special functions : Diagnostic facility, Integrated data memory, Reliable measuring in case of moved surface, foam, vapour, steam, build-up or condensation, Instruments shall be field changeable to other fluids and the electronics parts shall be replaceable type. Probe /measurement length : 1669/1219 mm Fluid : Boiler feed Water Process conditions: a. Operating Pressure : 20.0 Kg/cm2A b. Maximum Pressure : 32 Kg/cm2A c. Vacuum Conditions : NA d. Operating Temperature : 158 °C e. Maximum Temperature : 200 °C f. Foam present or absent : NA g. Vapour present or absent : Present.
VEGA India Level And Pressure Measurement Pvt Ltd
Lamtech Solutions LLP
Krohne Marshall Pvt Ltd
Bidder Name
Krohne Marshall Pvt Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .