Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.6 LAdmitted-Finance 00 ALAHLADPUR MAIRHI CHANDAULI CHANDAULI UTTAR PRADESH 232104 | CHANDAULI | UTTAR PRADESH | 232104 | L1 | Admitted-Finance | ||
| 2 | L2₹1.6 L+₹5,156.24 (3.26%)Admitted-Finance 130 2 RAM BAGH UPPER HARIPUR SUNDER NAGAR DISTRICT MANDI H P 175018 | MANDI | HIMACHAL PRADESH | 175018 | L2 | Admitted-Finance |
Tender Value
₹1.5 L
EMD Value
₹3,050
Closing Date
26 Feb 2026, 10:00 amClosed
EE Electrical Division HPPWD Mandi
EE Electrical Division HPPWD Mandi
Providing Lift shaft wiring Load Hook installation earthing in Combined office building Sandhol District Mandi HP
2026_PWD_128799_1
No.PW-MED-TA-Tender/2025- 6882-96 Dated- 05.02.2026
Open Tender
Electrical Works
Percentage
365 days
Sandhol, Distt- Mandi
As per SBD
13 documents required · 13 mandatory
₹350
₹3,050
12 Mar 2026
20 Feb 2026
2 Mar 2026
21 Feb 2026
26 Feb 2026
21 Feb 2026
Re-wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recessed Steel / PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable including dismantling of the existing wiring as required. (including switch & sheet etc.) as required.complete in all respect as per entire satisfaction of Engineer- in- Charge. Make:-Havells,Finolex,RR Kable, KEI,Grandley, Plaza(grandley and plaza)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required complete in all respect as per entire satisfaction of Engineer- in- Charge. Make :Havells (REO) (Athena), Goldmedal (Air)(GIFa), Anchor (Penta) ,Legrand (arteor),L&T(Entice)
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required complete in all respects and to the best satisfaction of Engineer-in-charge. i)Single pole Make:-Havells, ABB, Legrand, L&T, schneider, C&S
Supplying and fixing following rating, follwing pole, 240/415 V( four pole ), residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.complete in all respect as per entire satisfaction of Engineer- in- Charge. i) 25A DP Make:-Havells, ABB, Legrand, L&T, schneider, C&S
Supplying and fixing following rating, follwing pole, 240/415 V( four pole ), residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc.as required.complete in all respect as per entire satisfaction of Engineer- in- Charge. i) 63 A Four Pole Make:-Havells, ABB, Legrand, L&T, schneider, C&S
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) complete as required.complete in all respect as per entire satisfaction of Engineer- in- Charge.charge.i) 12 Way, Doble door Make:-Havells, ABB, Legrand, L&T, schneider, C&S
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit aas required.complete in all respect as per entire satisfaction of Engineer- in- Charge.i) 3 x 1.5 sq. mm Make:-Havells,Finolex,RR Kable, KEI, Grandley, Plaza (grandley and plaza )
providing & Laying of One number aluminium conductor PVC insulated and PVC sheathed armoured / XLPE POWER cable, 1.1 KV grade of following sizes on wall surface as required complete in all respect as per entire satisfaction of Engineer- in- Charge. i) Armoured cable 25sq. Mm (3.5 core)Make:- Universal Cables ,KEI, Havells, Grandley
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.complete in all respect as per entire satisfaction of Engineer- in- Charge.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthingas required.complete in all respect as per entire satisfaction of Engineer- in- Charge.
Providing and installation of of LEDBulk head fittinghaving lumen outputof 800 lumens with polycarbonate housing ,anti glare polycarbonate diffuser,surge protection 2.5 KV luminaire efficacy > 80lm/Watt with minimum 25000 burning hours,THD<15% in white finish and seprated energy efficient constant current, non-integral, electronic driver;relevent LM 79/80 complaince fromUN/NABL Lab suitable for input voltage: AC 140-270 V, 50/60Hz, Guarantee of LED fitting incuding LED 2 Years against manufaturing defect . as required.complete in all respect as per entire satisfaction of Engineer- in- Charge. (Make : Wipro / Bajaj / Goldmedal /Panasonic ,Phillips / Hevells/ Chengi )
Providing and installation of 2 No. Load hooks 25mm dia including drilling . Chisling of holes and welding of hooks to the exising reber for instlaation of lift at combinede office building Sandhole as required
S/E of MCCB 63 Amp. 4 pole 415 Volt. With Thermal Magnetic Release for oveload and short circuit protection 36 ka breaking Capacity (Ics=100% Icu with positive isolation ) with / without Spreader.Rotary Handle as Make:-Havells, ABB, Legrand, L&T, schneider, C&S
Providing and fixing SS Encloser For MCCB suitable upto 125A including drilling holes in the cubicle panel making connections etc.as required.complete in all respect as per entire satisfaction of Engineer- in- Charge.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.complete in all respect as per entire satisfaction of Engineer- in- Charge. i)25 mm dia( Medium Class)Make :Anchor, AKG, RKG, Precision Pipes, Diplast
stage.html
html • 0.03 MB
technical_190361.pdf
techsummary_190361.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.31 MB
SBD_Sandhol.pdf
Tender Documents • 4.51 MB
BOQ_190361.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .