Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.5 L+₹28,170 (2.52%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹12.0 L+₹82,999 (7.43%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹12.7 L+₹1.5 L (13.6%)Rejected-Finance | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹13.9 L+₹2.8 L (24.7%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L5 | Rejected-Finance Not L1 |
Tender Value
₹13.3 L
EMD Value
₹26,635
Closing Date
8 Jun 2018, 6:00 pmClosed
Sr. Manager(Engg-E)-I
AAI, Calicut Airport
providing fire alarm system for technical block
2018_AAI_11287_1
NIT-02/18-19
Open Tender
Electrical Works
Item Rate
60 days
Calicut Airport
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,120
AAI Calicut/Kondotty
₹26,635
Yes
2 Jul 2021
31 May 2018
14 Jun 2018
1 Jun 2018
8 Jun 2018
1 Jun 2018
1 Jun 2018 - 8 Jun 2018
Amount
Supply, Installation, Testing & Commissioning of intelligent Addressable Fire Alarm Panel with 2 loops (each loop accessing at least 300 devices and a maximum of 318 detectors) including battery backup. The fire alarm control shall include a fully featured operator interface control & annunciation panel that shall include a back lit 640 character LCD, individual, colour coded system status LEDs and QWERT style alapha numeric keyboard for field programmng and control of the FA system.The panel shall be microprocessor based with its own micro controller, memory, communication module and fire device loop interface cards for intelligent initiating and indicating devices and should also be networkable in peer-to-peer basis with other Addressable Fire Alarm Panels. The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all Control Switches when ever any Alarm is triggered. The panel shall have Keypad operation, L C D unit to indicate Fire / Fault Signal of individual unit, etc complete in all respects. 24 Volts sealed lead acid battery sufficient for 24 hrs back up with battery charger. The Panel shall also have Logic hardware and software built into it for initiating specific tripping, time delay operation of hooter etc. complete in all respects as required by the standard specifications. Panel shall have dynamic data sharing with Building Management System Platform through common protocol bus, panel or through Integator unit. Other requirements are given below : a) Programming of software for the system b) Automatic system test activates c) Detector sensitivity adjustments d) Alarm verification e) Alpha/numerical display f) Provision to connect to PCs and external printers g) Support modbus and bacnet protocol
Providing, installing, testing and commissioning of UL/ LPCB/FM/ EN54 Listed Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept / reset buttons for alarm address of any sensor / field device etc. complete in all respects as required by the standard specifications. The Repeater Panel shall only provide field device address with room number. Analogue Output is not required. The Panel shall be connected to the Fire Alarm Panel.
Supply, installation, testing and commissioning of UL/ LPCB/FM/ EN54Listed Analogue Addressable type Optical Smoke Detector complete with all accessories like base, base box, etc. (with flash scan ) to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete in all respects as required by the standard specifications.
Supply, installation, testing and commissioning of UL/ LPCB/FM/ EN54 Listed Analogue Addressable type Multi Detector complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete in all respects as required by the standard specifications.
Supply, installation, testing and commissioning of UL/ LPCB/FM/ EN54 Listed Analogue Addressable type Heat Detector (Fixed cum-rate of rise type) with range upto 68o C complete with all fixing accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete in all respects as required by the standard specifications.
Supply, installation, testing and commissioning of Listed Response Indicators outside the rooms for getting fire indications of detectors installed above false ceiling area / inside the rooms interconnecting to loop cable complete in all respects as required by the standard specifications.
Supply, installation, testing and commissioning of UL/ LPCB/FM/ EN54 Listed addressable loop Isolators to protect one area or a number of devices with complete set to be installed under/above false ceiling, roof, concealed space, wall, etc. interconnecting to loop cable complete in all respects as required by the standard specifications.
Supply, installation, testing and commissioning of UL Listed Addressable type Manual Call Point (break glass type/pull type) complete with Input Module, push button, enclosed in box with provision for cable or conduit coupling etc.complete in all respects as required by the standard specifications. The unit to be painted fire red outside, white inside.
Providing, installing, testing and commissioning of UL/ LPCB/FM/ EN54 listed Hooter cum Strobe with Base plate complete in all respects as required by the standard specifications.
Providing, installing, testing and commissioning of UL/ LPCB/FM/ EN54 listed control module for Hooter cum Strobe with Base plate complete in all respects as required by the standard specifications.
Supply, laying/fixing, termination etc. of following size insulated FRLS armoured copper cable in surface/ recess / above false ceiling /concealed space/wall concealed, etc. for control cabling of Fire detection and alarm devices and interconnecting them by 2 x 1.5 sq mm etc complete in all respects as required by the standard specifications.
Supply and Installation 24V DC power supply
Supply and laying of DWC pipe 50/38 mm alongwith all accessories as required in existing trench
Onyx Fire Protection Industries
SALIMAX SYSTEMS AND CONTROLS ENGG
Sagtaur Universal
Manish Electricals
Deworth Equipments Pvt. Ltd
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .