Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC M/S Krishna Construction Company is the Lowest Bidder, hence accepted | |
| 2 | L2₹16.5 L+₹54,264 (3.40%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹16.7 L+₹76,193 (4.77%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
₹1.9 L
EMD Value
₹39,000
Closing Date
26 Nov 2022, 6:00 pmClosed
GE (AF) PHALODI
GE (AF) PHALODI
PROVN OF ACs AND ALLIED ACCESSORIES FOR RADAR INTEGRATED OPS ROOM IN SRE BLDG AND PROVN OF COVERED PARKING GARRAGE FOR 02 IMDM OF RRS EQUIPMENT AT AF STN PHALODI
2022_MES_560469_1
8460/A/E8
Open Tender
Miscellaneous Works
Item Rate
240 days
GE (AF) PHALODI
Class E Cat b (i)
7 documents required · 7 mandatory
₹500
GE (AF) PHALODI
₹39,000
Yes
18 Jan 2023
29 Oct 2022
3 Dec 2022
29 Oct 2022
26 Nov 2022
12 Nov 2022
Amount
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of capacity 1.5TR with Environmental Friendly gas Complete all as specified and directed. NOTE:- (i) Additional Length of copper tubing to standard length supplied with equipment if required at site shall be supplied and fixed by the contractor without any extra cost. (ii) Additional quantity of refrigerant and compressor oil if any required as per site shall be provided by the contractor without any extra cost (iii) GI tubing for condensed water shall be supplied and fixed by the contractor without any extra cost. (iv) The S/S stands for mounting of outdoor unit of AC will be provided by the contractor without any extra cost.
Supply and installed voltage stabilizer for automatic operation single phase naturaly air cooled indoor type & designed for input variation between 170 to 250 volts with output voltage stabilized at 230 volt with accuracy of +/- 2.5% & of capacity 5.0 KVA complete all as specified and directed.
M&L for Wiring for circuit/submain wiring earth wire alongwith earth wire with 2 x 6.0 sq. mm + 1 x 4.0sq. mm sizes of FRLSH PVC insulated copper conductor, single core cable in PVC Caping & Casing as required at site complete. Note:- One RM length of 2 x 6.0 sq. mm + 1 x 4.0sq. mm with PVC Caping & Casing with fixing accessories will be counted as one RM.
S&F Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket with one single pole MCB of 20 Amps 240V incl complete all as specified and directed.
Supply and Fixing Double Door Sheet metal Enclosure Triple Pole and Neutral 8 Way with 200 amp 415V rated bus bar complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide & not exc 1.5 m in depth for foundation & for laying of cable getting out in soft/loose soil complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and directed.
Material and Labour for dry tibba sand in trenches cushioning to under ground cable spreading levelling hand punning complete all as specified and directed. Note:- Punned down thickness will be measured for payment purpose.
Supply and lay un-reinforced precast concrete cable covers type 2, flat, size 250mm x 150 mm x 40 mm complete all as specified and directed.
Supply and Fixing MCCB 4 pole 415 Volt adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed.
Supply and Fixing MCB TPN 125 Amps C curves MCB with breaking capacity 10 KA complete all as specified and directed. Make: Indoasian
Supply and Fixing amp rating 240 V, 15 KA 'C" curve miniature circuit breaker (MCB) of single pole and current carriying capacity 32 Amps complete all as specified and directed. Make: Indoasian
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried directly (vertically) in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized strip 32 x 6mm earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of strip and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing and including dismantling of old unserviceable earthing complete all as specified and directed. Note : (i) The cost of 7.5m earth lead /copper strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work, RCC & PCC etc are included in the quoted rate. (iii) On testing after completion, if the earth resistance less than 0.5 Ohms is not obtained earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
Supply and laying LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoure, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 Core complete all as specified and directed.
Supply and lay un reinforced precast concrete cable covers LV Type 2, flat, size 300mm x 180mmx 40mm complete all as specified and directed.
M & L for point wiring for one light point controlled by one switch with 1.5 Sqmm PVC insulated, sheathed multi strand copper conductor cable FR-LS in PVC conduit ISI marked, steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface 1.5 Sqmm copper conductor cable FR-LS connected to common earth dolly complete all as specified and directed.
Supply anf Fixing switch piano flush type, 5 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed.
Supply and Fixing LED batton fitting 1 x18/20 Watt, 6000K, 4" complete fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed.
S&F ceiling rose surface bakelite 65mm x 50mm, 2 to 3 terminals with back plate etc complete all as specified and directed.
S&F LED light fitting, 1X35 watt, 230V AC complete with tuff net glass protection IP:66, fixed to walls with GI bracket made out of suitable size of light grade pipe 32 mm dia tubing upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of 25x3 mm MS flat iron with suitable bolt and nuts and testing etc complete all as specified and directed.
Supply and fixing sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 2 way, 240 Volt, suitable for fixing MCBs, isolators etc complete all as specified and directed.
S&F MCB SPN 32 amp c curves MCB repturing capacity 10 KA etc complete all as specified and directed.
M&L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
M&L Cement concrete 1:4:8 (Type D2) in foundations, filling and mass concrete all as specified and as directed.
M&L for Cement concrete 1:3:6 type C2 in foundations, filling and mass concrete complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks of Cement concrete 1:3:6 type C1, exc. 10cm in width and set in mortar CM 1:6 complete all as specified and as directed.
M&L for broken stone or boulder Hardcore of gauge n. exc. 63 mm deposited, spread and levelled in layers n exc. 150 mm thick watered and rammed to a true surface complete all as specified and directed.
M&L for Cement concrete 75 mm thick Type D2 (1:4:8) using 40 mm graded aggregate and finishing the concrete surface even and fair without using extra cement complete all as specified and directed.
M&L for Cement concrete 100 mm thick Type B1 (1:2:4) using 20 mm graded aggregate and finishing the concrete surface even and fair with broom finish without using extra cement complete all as specified and directed.
M&L PCC 1:3:6 type C-1, (using 20mm graded aggregate) 75mm as in plinth protection and finished even complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick or concrete surfaces or block masonry surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick plastering on concrete/ masonry wall surfaces externally in two layers such as first layer 10mm in CM 1:6 and second layer 5mm in CM 1:4 with water proofing compound @ 3% by weight of cement content or as per manufacturer's instructions and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. (Note :- WPC will be measured and paid seperately under respective item in this schedule).
Supply only Integral water proofing compound (WPC), conforming to IS and as approved complete all as specified and directed.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) Fe 410-W (Gde E-250) including distance pieces, cleats etc. complete all as specified and directed.
S&F for fixing of wind ties for roof including securing bolts etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F Rolled sections Fe-410 W (Gde E-250) as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc complete all as specified and directed.
S&F Mild steel screw bolts n exc 5cm long and 5 to10mm dia neck (machine made) with hexagonal or square heads at one end and the other end to be fitted with washers and one hexagonal or square nut complete all as directed.
S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described, applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome all as specified and directed.
Removing excavated soil to a distance exc. 250 m but n.exc. 500 m & deposited where directed.
M&L for preparing new plastered surfaces of walls, applying two coats of cement base paint of 1st grade quality, in one or more tints and pattern (camouflage) over a coat of primer as approved complete all as specified and directed
M&L for preparing new plastered surfaces of walls, applying three coats of white wash complete all as specified and directed
M/S SOLANKI GENERAL SUPPLIERS
M/S HARIOM CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .