| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance LAXMI BAZAER TEHSIL JOGINDERNAGAR DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹6.1 L
EMD Value
₹12,200
Closing Date
20 Aug 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE
EXECUTIVE ENGINEER JAL SHALTI DIVISION BAGGI DISTT MANDI HP
AS PER BOQ
2021_HPIPH_51155_1
EE-JSD-BAGGI/2021- 15422-72 DATED 11/8/2021
Open Tender
Civil Works
Item Rate
90 days
BAGGI
AS PER NIT
8 documents required · 8 mandatory
₹250
EE BAGGI
₹12,200
Yes
27 Aug 2021
12 Aug 2021
21 Aug 2021
12 Aug 2021
20 Aug 2021
12 Aug 2021
120 days
Amount
Excavation in foundation,trenches (for pipes & pits) up to all depths in all classification of earth work such as pick work, jumper work,saturated soil including bailing and pumping out water, blasting soft/hard rock or chiseling soft/hard rock where blasting is prohibited in all lifts including trimming & dressing of sides, levelling of beds to correct grade i/c shoring/ strutting, planking, timbering & dewatering wherever required, stacking the useable of unuseable material/ soil separately & after excavated soil clear from the edge of excavation returning the excavated soil after laying jointing testing of pipes in trenches in 15 Cm layers including consolidating of each deposited layer by ramming & watering & then disposing of all surplus Excavated soil/unusable material as directed with in all leads & lifts including restoration of unmetalled surfaces to its original condition & including cost of diversion for traffic,night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per the entire satisfaction & directions of Engineer- in- charge.
Laying, jointing and testing in trenches (to be levelled, to grades) GI flanged pipes of following diameter, class & wall thickness and IS specification capable to with stand the required hydraulic test pressure as per IS Code in a random length of 4 mtrs. to 7 mtrs. with bevelled ends and jointed with flange tables mentioned below conforming to IS 6392-1971 (latest with upto date ammendments). The welding of flanges to be done on both faces in double layer to make the joint leak proof according to relevant BIS standards and detailed specifications. The pipe including nuts & bolts of required sizes, 3mm thick compressed asbestos fiber jointing gasket or synthetic rubber gasket confirming to relevant BIS codes (including all kinds of flanged short pieces, bends, tees & other specials etc made from parent tubes & provided and welded with flanges of tables as applicable for the particular reach as per site conditions, including cutting, welding, flushing,cleaning & hydraulic testing of pipe as per directions of Engineer-in-charge. (GI Pipes will be supplied by the department free of cost).
80mm dia, RD 0 to 1370, GI IS 1239 (M), wall thickness 4.00 flange table-17
Laying, jointing & testing in trenches (to be levelled to grades) IS marked GI pipes (Medium grade) of following dia confirming to IS 1239-1991 (part-II) (latest with upto date amendments) including butt welding of pipe ends to make water tight joint including carriage of material up to all leads and lifts. This work also includes fabrication of short pieces, bends tees and other specials etc. from parent tubes with butt welding in three layesrs as applicable for the particular reach & of technical specification as per site conditions including flushing, cleaning & hydraulic testing complete to the best satisfaction of Engineer- in- charge. The laying of pipe shall confirm to IS : 5822-1994 and as per CPHEEO manual. The rates also includes the carriage of GMS tubes from the JSV divisional store Baggi to the site of work. butt welding of joints , fabrication of short pieces , bends , tees & other specials etc. from parent tubes, flushing , cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts ( Earth work in trenches will be measured and paid for separately)
80mm dia, RD 0 to 1370, GI IS 1239 (M), wall thick 4.00
Supply of submersible Polder pump for raw water of reputed make such as KSB/CALAMA/SU/JOHNSTON make conforming to latest relevant BIS Code. The pump should be fitted with free flow impellers of Bronze/suitable alloys as per BIS 5659-1970 latest suitable for Raw water 50 PPM having greased packed bearings and shaft with bound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti/Crompton make conforming to relevent BIS code latest with up to date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, errection clamps, cable clips and depth gauge etc. and suitable for operation on data given below:-
A) SITE LOCATION:-i) Location of site about 12 KM from Nerchowk ii) The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mtr. iii) Humidity : Weather generally remains humid during monsoon season iv) Nature of atmosphere : As normally encountered in Shivalik Range.v) Detail of quality of water -Clear cold water.vi)Water free from sand or not- free from Sand vii) Water corrosive or not - No/Yes viii)Turbidity (if any)-50 PPM ix)NPSH available:-Positive Suction x) Any other information or requirement ---- B) OPERATING CONDITIONS:-i) Type of current -AC three/single phase ii) Operating frequency - 50 HZ iii) Rated voltage -400 (+/-) 10% volts iv)System of earthing if any to be adopted-Double loop earthing as per BIS 3043-1987 latest with upto date ammendments v)No. of Working hours per day-8 hours vi) Speed of revolution in RPM-To be quoted by tenderer vii) Direction of rotation -To be quoted by tenderer viii)The max. Temp. of cooling air & water in the place in which the pumpset is intended to work in ordinary service.-35 Degree Centigrade
C) MOTOR:- i) Ref to BIS code :-BIS 325-1978 read with BIS 900-1992 latest with upto date ammendments ii) Type of enclosure of motor :-SPDP (As per BIS 4691-1985, latest).iii) Type of duty-Continuous iv) Mechanical out put in KW -Suitable for driving centrifugal pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover.v) Class of insulation - Class -B vi)Max.permissible temp.rise of motor reqd. if different from given in B (viii) above. _____ vii) Particulars of test reqd. & where they are to be conducted.- As per terms & conditions viii)Particulars as to whether voltage limiting device will be employed- ATS / Star Delta starter oil immersed,fully automatic to be installed between bus bar chamber & motor.Shunt capacitor is also proposed to be installed for improving the power factor at site.NOTE:- Star delta starter upto 37.5 KW & ATS for 37.5 KW to 50 KW & stator rotor starter with slip ring motor beyond 50 KW.ix)Motor whether squirrel cage or slipring-Squirrel cage/slipring Note:- Squirrel cage upto 65 HP and slipring above 65 HP x) Details of shaft extension required-Just sufficient to provide direct drive by flexible coupling to pump.xi)Type of slip ring gear whether continouly rated or for starying purposes only & whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required.-Continouslly rated for Squirrel cage/ Slipring motor.xii) Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit.- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.xiii) Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period.-To work the pump offered xiv)Where possible fault capacity of the system to which the motor is connected.The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
D) PUMP (BIS 1520-1980) read with BIS 9137-1978 both latest with upto date ammendments :- a)Nos of pumps reqd. -2 no. of pumps (one will act as standby).b) Spare parts required - For two years normal maintenance as recommended by manufacturer.c) Optional fittings reqd. -Air cock for exahausting air from each stage.E)PUMP OPERATING CONDITIONS:-i) Capacity-3.03 LPS for each pump.ii) Total head in Mts.-104.54 Mtr ( If total head is not known then following details be provided) :- i) Static head -97.00 Mtrii) Minimum depth of water -90.00 Mtrs. (Bore Well) iii) Variation in water level………….. Mtrs.iv) Ground level to max. water level ------------------- Mtrs.v) Ground level to delivery point 787 Mtrs.vi) Pressure in the suction tank …………. Kg/cm^2 vii) Pressure in the delivery tank …………. Kg/cm^2 iii) Length of R/Main -1370 Mtr iv) Dia of R/Main -80 mm Dia v) Drive arrangement -Direct through flexible coupling on a common base plate.vi) Drive Type-Electric Driven vii)NPSH required-To be quoted by the tenderer.viii) Limits of total head in which the pump is reqd. to operate.- (-) 25% to (+) 10% of total head.ix) Suction/delivery size of pump -To be specified by the tenderer x) Efficiency of pump at- To be specified by the tenderer a) Duty head b) (+) 10 % head c) (-) 25 % head xi) Material of construction-To be specified by the tenderer (Manufacturer's certficate to be appended)
Supply of suitable oil immersed star delta starter/ATS/star rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling . Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50 KW.
Providing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box, operating handle and trip/reset bush button on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on/ off breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition) recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, high voltage & overloading & phase voltage difference.
Change over Switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable capacity
Supply of Kirloskar/ Kilburn/IVC/ Fouress/ Gled/ BHEL/ Leader of reputed make of suitable size cast iron/ cast steel double flanged sluice valve having size equal to delivery of pump and capable of withstanding nominal seat pressure of _____ kg/cm^2. Note: The sluice valve shall confirm to BIS: 780-1984 latest with up to date amendments. However, if the seat pressure exceeds the the limits prescribed in BIS 780 then the sluice valve shall be of cast steel confirming to class 150 ASA (seat pressure 21 kg./cm^2) or class 300 ASA (seat pressure 52 Kg./cm^2 ) or class 600 ASA (Seat pressure 104 Kg./cm^2) as per BIS 1414 (API 600).
Supply of Kirloskar/ Kilburn/IVC/ Fouress/ Gled/ BHEL/ Leader of suitable size cast iron/ cast steel double flanged swing check type reflux valve having bye pass arrangement and size equal to delivery of pump and capable of withstanding nominal seat pressure of _____ kg/cm^2. Note: The sluice valve shall confirm to BIS: 780-1984 latest with up to date amendments. However, if the seat pressure exceeds the the limits prescribed in BIS 780 then the sluice valve shall be of cast steel confirming to class 150 ASA (seat pressure 21 kg./cm^2) or class 300 ASA (seat pressure 52 Kg./cm^2 ) or class 600 ASA (Seat pressure 104 Kg./cm^2) as per BIS 1414 (API 600).
Supply of Kirloskar/ Kilburn/IVC/ Fouress/ Gled/ BHEL/ Leader of suitable size cast iron/ cast steel double flanged swing check type reflux valve having bye pass arrangement and size equal to dia of R/main for withstanding nominal seat pressure of _____ kg/cm^2. Note: The sluice valve shall confirm to BIS: 780-1984 latest with up to date amendments. However, if the seat pressure exceeds the the limits prescribed in BIS 780 then the sluice valve shall be of cast steel confirming to class 150 ASA (seat pressure 21 kg./cm^2) or class 300 ASA (seat pressure 52 Kg./cm^2 ) or class 600 ASA (Seat pressure 104 Kg./cm^2) as per BIS 1414 (API 600).
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type GI strainner of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with upto date ammendments.
Providing and Laying suitable size copper PVC insulated armoured power 3 1/2 core cable confirming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing and Laying jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from OCB to motor, motor to starter including all other electrical equipments such as Thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing and Laying double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply of standard make 100 mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Providing and Laying Delivery pipe considering site requirements,NPSH required & available and common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets,3mm thick as per BIS-2712-1978 , nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii). NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge.
Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments from S.No. 4 to 7, 9 to 11 i/c cost of tees, bends, tapers & any other fittings required as per site conditions & as per directions of Engineer-in-charge.
Naik Electrical Works
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .