Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹38.8 L+₹46,443.61 (1.21%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹43.3 L+₹4.9 L (12.8%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹46.8 L+₹8.4 L (21.9%)Rejected-Finance D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L4 | Rejected-Finance Not lowest |
Tender Value
₹40.7 L
EMD Value
₹81,500
Closing Date
28 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
PROVN OF INFRASTURCTURE FOR STRATEGIC COMMUNICATION NETWORK (SCN) UNDER LBW AT INS KALINGA UNDER GE (P) NAVY KALINGA, BHEEMUNIPATNAM VISAKHAPATNAM
2022_MES_521369_3
GE (P)/N/K/8897 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class D, Category a(i) , b(i)
6 documents required · 6 mandatory
₹500
Yes
Garrison Engineer P Navy Kalinga Visakhapatnam
₹81,500
Yes
11 Aug 2022
9 Jul 2022
30 Jul 2022
9 Jul 2022
28 Jul 2022
16 Jul 2022
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m and not exc 3.00m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil
Plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
RCC (1:1.5:3) design mix Type A1 (using 20mm graded stone aggregate) as in foundations, including rafts, bases for columns etc basement slabs etc.
RCC (1:1.5:3) design mix Type A1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc.
RCC (1:1.5:3) design mix Type A1 (using 20mm graded stone aggregate) as In walls, retaining walls, basement walls and the like, any thickness above top of footing.
Use and waste of formwork to sides of foundation, footings, bases of columns and similar works, vertical or to batter.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions.
Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings, vertical or to batter.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per Srl item No. 10 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups,spacers and binders.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated earth n.exc 50M and depositing where directed at a level not exc 1.50M above the starting point.
Rough excavation not exc 1.5M deep and getting out in hard/dense soil.
Removing excavated earth exc 1.5 KM but not exc 5.00KM and depositing where directed at a level not exc 1.50M above the starting point.
Forming embankments including raising or lowering earth, spreading in layers not exc 30cm thick, watering, ramming/rolling and finishing to required size, shape etc not exc 1.5m high from base.
Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6
Boulder pitching ,laid dry, hand packed tightly, grouted with cement and sand mortar(1:6)
Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality- A
Mild steel bolts,purposre made, 12 to 20mm neck dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long.
Hardcore of broken granite stone of gauge exc. 63 mm but not exc 100mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface
100 mm thick Plain Cement concrete of type B2, 1:2:4 (40 mm graded aggregate) in floors, finished even and smooth without using extra cement
75 mm thick Plain Cement concrete of type D2, 1:4:8 (20 mm graded aggregate) as in sub base of floors
15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and directed
Preparation of new plastered wall surfaces and applying two coats of exterior emulsion paint over one coat of primer on external surfaces of walls etc complete all as specified and directed.
Dismantling of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles portions ordered to be dismantled
Cement concrete of type C1, 1:3:6 of (20 mm aggregate) in , hold fast, coping of poles and the like including necessary formwork as directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
1 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
Preparation of steel or iron Surfaces of any description, over 10cm in width or girth, not otherwise described applying two coats of synthetic enamel paint over a red oxide primer.
12 mm thick toughened glass door of size 1.00mx2.10m with openable one leaf shutter using the following stainless steel fittings of polished chrome finish (Satin stainless steel finish for handles) including acid finish for the entire surface of the door with white acid leaving tagline of approx. 300mmx300mm size using suitable stencil, etc on openable shutter and including cutting necessary holes and cut outs complete all as specified and as directed by the Engineer-in-Charge. (i) Corner lock patches with EPC and trike plate XL-C-4011A: 1 No. (ii) Floor springs with 90 degree open (EN4) : 1No. (iii) Top patches XL-C-4012: 1 No. (iv) Bottom patches XL-C-4013 : 1 No. (v) Top pivots XL-C-4014 - 1 No. (vi) 450mm long H-Type handles 25mm dia, of grade SS 304, XL-C-3003A:1set for openable shutter
Pre cast cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) set in cement mortar 1:6 for drain covers, man holes cover etc. (Note : Reinforcement shall be measured separately)
Surface Excavation n.exc 30 cm deep and avg 15 cm deep and getting out in any type of soil
75 mm thick Plain Cement concrete of type C1, 1:3:6 (20 mm graded aggregate) in subbase
Designer cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey and cement pigment in floors over a screed bed of 20mm thick in cement mortar 1:4
precast cement concrete in 1:2:4 type B1 in Kerb Stone window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match
Point wiring with PVC insulated unsheathed multi stranded copper conductor cable of size 1.5Sqmm drawn through and including PVC conduit 25mm (ISI Marked) with accessories and 3mm thick new hylam sheet cover over (ISI Marked) the existing sunken boxes, including 1.5 sqmm copper conductor cable for earth continuity green in colour for one 5 Amps switch socket combination outlet independent , complete all as specified and as directed by Engr-in-charge. Note:- All the disturbed surfaces of wall / ceiling shall be made good to match the existing wall / ceiling finishes and as directed by the Engineer-in-Charge.
All as per item No. 37 above but for 15/16Amp switch socket out let, independent with 4 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4 Sqmm for earth continuity conductor, complete all as specified
Switch socket combination 2 pin & 3 pin 5Amp, 230 volt, multipurpose, 2 screw to fix on board complete all as specified.
Switch socket combination 2 in 1 type, 3 pin 5 / 15Amp, 230 volt, multipurpose, 4 screws to fix on board complete all as specified.
Test & commissioning of VTPN Distribution board with provision for 100Amps MCCB as incomer and MCB 4 way IP43 as outgoing with all connecting fitting and fixtures including internal connections complete all as specified and directed by Engr-in-charge. Make-: C&S cat No. CSDBMCCB100DD04IP43S or equivalent as approved by GE
Factory made sheet metal enclosure with protected type 2 pin earth plug and socket with one MCB SP 240 volt, 20 Amps all as specified.
In repair sub main wiring with two run of 4.0 Sq. mm PVC sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sq mm drawn through PVC conduit, including taking down u/s sub main wiring of any type, complete all as specified. Note : Copper conductor 2 run and one run of copper earth wire along with conduit shall be measured as one length.
In repair sub main wiring with four run of 6.0 Sq. mm PVC sheathed, copper conductor cable, 1100 Volt, and two run of copper earth wire 6 Sq mm drawn through PVC conduit, including taking down u/s sub main wiring of any type, complete all as specified. Note : Copper conductor 4 run and 2 run of copper earth wire along with conduit shall be measured as one length.
In repair Rigid non-metallic PVC conduit of size 25 mm in dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc
Stainless Steel Galvanized Coating Galvanized Cable Tray, Sheet Thickness: 10 - 15 mm, and 125mm rail height complete all as specified and as directed.
Finger print biometric door access control system with optical sensor, minimum 30 finger print for access complete all as specified and as directed.
Install and commissioning of electric driven single phase 50Hz 220 Volt,split AC of capacity 2 TR, BEE minimum 5 Star rated with Rotary type Compressor and Refrigerant type R134 A complete all as satisfactory level of Engr-in-Charge.
In repair to voltage stabilizer of 4 KVA low voltage corrector with input voltage of 160 to 260 volts and out put voltage 240 + /-1% complete all as specified and directed. Make : V-Guard/Shakti/Zenith or equivalent as approved by GE
Supply, laying and Testing LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified and directed by the Engineer- in- charge
24 Core single mode armoured UG OFC cable complete all as specified and directed by the Engineer- in- charge
Four lines of two core copper cable for fax and voice line for seed and naval exchange telephone complete all as specified and directed by the Engineer- in- charge
HDPE pipe of size 90mm dia suitable for 0.4mpa working pressure complete all as specified and directed by the Engineer- in- charge
24 Core OFC Splicing suitable for 24 core OFC Cable complete all as specified and directed by Engr - in - charge.
Boring of holes under road, pavement, hard standing by trenchless technology insertion of HDPE pipe of 140mm bore dia suitable for 0.4 mps working pressure for cable protection complete all as specified and directed by Engr-in-charge.
Earthing complete with Copper earth plate electrode 600x600x3.15mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to 20x3mm copper strip as earth lead (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of all as shown in electrical plate No 5, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out Soft/Loose soil for laying of under ground cable complete all as specified and directed by Engineer - in - Charge.
Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 complete all as specified and directed by the Engineer- in- charge
PCC 1:2:4, type B-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete of poles complete all as specified and directed by Engr-in-charge.
Single pointed air termination copper rod 12mm dia, 300mm long complete all as specified and directed by Engr-in-charge.
Aluminium strip 25mm x 3.15mm complete with saddles and fixing screws for fitting the strip all as specified and directed by Engr-in-charge.
Copper strip 32mm x 6mm buried in ground all as specified and directed by Engr-in-charge.
UPS for 30 min back up single phase 160 to 240v and output 230 +/-1% of capacity 5 kva with lithium ion batteries and rack , LCD panel with necessary wiring and fitting complete all as specified and directed by Engr-in-charge.
LED street light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 66 protection luminaries of capacity 45 Watt,230V,50 Hz with 40mm GI pipe complete all as specified and directed by Engineer-in-Charge . Make:- Crompton Cat part no RP-409-45-57-SL-GL-NS or equivalent as approved by GE
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screw all as specified and directed by Engr-in-charge.
Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detector and 99 module upto 200 detector complete all as satisfied and directed of Engr-in-Charge
Detector complying with and type certified to EN-45 Addressable type Multisensor detector with heat and smoke combination photoelectric / optical with base with self built intelligence as per IS: 11360 complete all as specified and directed.
Note : 1. All items in the schedule shall be read in conjunction with S&F or M&L as applicable 2. All items shall be completed in all respect as directed by the Engr-in-Charge.
Ruchira Associates
SRI SAI KRISHNA ENGINEERING WORKS
SRIVALLI ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .