Provision of New Electronic Interlocking work at Jhantipahari (JPH) station in connection with dismantling of UP and DN main line cross over & one UP Passenger platform & one Goods shed line in Adra Division of South Eastern Railway.
SnT_e_Tender_ADA_25_26_26~SER
SnT_e_Tender_ADA_25_26_26
Open
Works - General
12 Months
Kolkata, West Bengal
₹0
₹3.6 L
13 Apr 2026
20 Mar 2026
30 Mar 2026
A-SOR ITEMS : Provision of New Electronic Interlocking work at
Preparation of Station Working Rules (SWR) in English on the basis of station working 1 rule diagram/gate working rule diagram to be supplied by the contractor. Submission of two draft copy to railway for checking and resubmission of draft in three copies for approval of division after making corrections. Soft copy (Editable form) to be supplied in pen drive.
Preparation of Station Working Rules (SWR) in Hindi/Regional Language of that station. Procedure to be followed as per above item.
Supply of 1 copy of SWR in English finally approved by railways along with spiral binding. This has to be done after CRS sanction has been obtained. Inspection: Representative of Sr.DSTE/Adra.
Supply of 1 copy of SWR in Hindi/Regional Language of that station finally approved by railways along with spiral binding. This has to be done after CRS sanction has been obtained.Inspection: Representative of Sr.DSTE/Adra.
Preparation of Gate Working Rules (GWR) in English on the basis of station working 5 rule diagram/gate working rule diagram to be supplied by the contractor. Submission of two draft copy to railways for checking and resubmission of draft in three copies for approval of division after making corrections. Soft copy (Editable form) to be supplied in pen drive.
Preparation of Gate working rules (GWR) in Hindi/Regional Language of that LC Gate. Procedure to be followed accordingly.
Supply of 1 copy of GWR in English finally approved by railways along with spiral binding. This has to be done after CRS sanction has been obtained.Inspection: Representative of Sr.DSTE/Adra.
Supply of 1 copy of GWR in Hindi/Regional Language that LC gate finally approved by railways along with spiral binding. This has to be done after CRS sanction has been obtained. Inspection: Representative of Sr.DSTE/Adra.
Supply & erection of SM TABLE (wood shall be of good quality such as Sheesham wood etc.) for DUAL VDU of suitable size as per approved drawings communicated by site engineer as per Station requirements. Inspection: Representative of Sr.DSTE/Adra.
Miscellaneous arrangements for NI period comprising of a) Temporary goomty/Tent of dimension atleast 12'x12' at both side of the station yard and at central panel building, furnished with one table, six chairs, emergency light and mosquito repellent. b) Sufficient temporary lighting arrangement throughout the yard from Sunset to sunrise one day prior, during and post NI work. This includes provision of two DG set of minimum 7.5 KVA capacity and halogen flood lights. The DG 10 sets and Diesel etc. has to be arranged by the contractor at his own cost. c) Provision of PA System at both the end of the yard. d) Resting arrangement for atleast 16 staff at night. e) Vehicle for transportation for to and fro movement of S&T staff during NI period. f) Manning of adjacent station to be done by contractor. g) Provision of printing/Xerox copies of drawings, wiring diagram, CTR/ Location box terminal chart, point wiring, MSDAC/track circuit wiring, NI program, Signal wiring, track bonding plan, etc. in a plastic folder. No. of copies depends upon the number of team formed for NI and as per instruction of officer incharge of NI. h) This also includes Free home & Free Starter wiring for NI as per the instruction of site engineer. Up to 200 Routes.
Excavation of trench in all kinds of soils including soft rocky area and clearing of roots of trees, rocks, bushes, ballast & reconditioning etc., including bailing out water and disposal of 12 extra soil including back filling with excavated earth and ramming of trenches after cable laying for the following depths and widths as specified in Technical Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER. Note:- In case, trenches are other than prescribed depth & width, Proportionate payment shall be released.
Excavation of trenches including clearing of roots of trees etc.in hard/rocky soil by chiselling up to a depth of 0.5 meter to 0.8 meter and width 0.3 meter at the bottom, supply & placing split RCC pipes with collar (for jointing pipes) of 100 mm nominal diameter to Spec. No. IS: 13 10262- 1982 or latest and IS-456-2000 as per SEM Drawing No. 15- D3 (Sheet-2) on sieved soil of 30mm over cable and concreting(1:2:3) throughout the length upto a layer of 75mm approximately, then back filling the trench by digging and carrying earth from a distance of maximum 30 meters and then ramming of soil after cable laying. This includes Split RCC Pipes with collar and all the materials for concreting are to be supplied by the contractor. Materials inspection shall be done by Railway Site Engineer.
Excavation of trench in all kinds of soils including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 metre. For Track/ pucca road/platform crossing/ level crossing as per SEM Drawing No.15-D5 including supply, transportation and laying of RCC Pipes(full) with collar(for jointing pipes) Inner diameter/Outer diameter: 100mm/150mm to 14 Specification No. IS: 10262-1982 or latest and IS-456-2000 RCC structural drawings as per SEM Drawing No. 15-D3 (Sheet-2) in trench and drawing of cable through RCC Pipes with collar(for jointing pipes) including back filling and ramming after cable laying as specified in Technical Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER for S&T Cables (Cable laying charges is also included).This includes repairing and plastering of platform/pucca road after cable laying. Material inspection shall be done by Railway Site Engineer.
Excavation of trench in all kinds of soils including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 mtr. For Track/ pucca road/platform 15 crossing/ level crossing as per SEM Drawing No.15-D5 including supply, transportation and laying of DWC pipes (full) with collar(for jointing pipes) Inner diameter/Outer diameter:103mm/120mm to Specification No.14830(Part- 2):2001 as per SEM Drawing No. 15-D4,in trench and drawing of cable through DWC pipes with collar(for jointing pipes) including back filling and ramming after cable laying as specified in Tech. Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER for S&T Cables (Cable laying charges is included). This includes repairing and plastering of platform/pucca road after cable laying. Material inspection shall be done by Railway Site Engineer.
Excavation of trenches at kacha roads / under the low flooded bridges / culverts or places as advised by the site in-charge of the Railway and placing of RCC(full) pipe 100 mm dia. 16 inside excavated trenches of suitable depth at kacha road/ culverts and Concreting the collars at the places of joints and at both ends. Note:-RCC pipe 100 mm dia. with collars Spec. No. IS: 10262-1982 or latest and IS-456-2000 as per SEM Drawing No. 15-D3 (Sheet-2) Class NP2 and concreting materials for collars will be supplied by the contractor. Material inspection shall be done by Railway Site Engineer.
Cutting and smoothening of inside surface of sizes 80 mm deep and 170 mm width for single/multiple cable chase in concrete or hard rocks or platform or cemented floor. This work 17 includes laying and covering of cable laid in the chase with standard sizes Second class/Fly Ash brick placed and embedded longitudinally and plastered on the top of the bricks and curing 72 hrs. as per Drawing No. Con/SK/T/1 for the following. (i) Single cable/Multiple cable (upto 3) (see Note 4 of Drawing no. Con/SK/T/1). Note: Bricks, sand and cement shall be supplied by the contractor at site and to be inspected by Railway Site Engineer before placing in the chase.
Supply, transportation and fixing of Galvanised Iron Pipe (make: TATA/Jindal or better) with threaded collars (for jointing pipe) of 80 mm nominal bore Specification No. IS: 1239, thickness 3.2 mm medium grade, on bridges, culverts, drain or at places as per instruction of the site Engineer including supply and transportation of materials required for fixing the pipe as per SEM 18 Drawing No.15-D7 including drawing of cables inside the pipe with masonry work at bridge entry and exit of the culvert and curing for 72 hours and pipes are to be clamped at max. 2 meter apart with drilling of holes on the pipe at 10 cm apart for the following S&T Cables. The Galvanized iron pipes and other materials required for fixing to be supplied by the contractor. Material inspection shall be done by Railway Site Engineer before use. This also includes dismantling of released GI Pipe/Trough and the released material should be returned at concerned store.Inspection: Representative of Sr.DSTE/Adra.
Transportation, laying including supply of Split RCC pipe as per Spec. No. IS: 10262- 19 1982 or latest and IS-456-2000 & SEM Drawing No.15-D3 having plain ends with their jointing loose split collar half round of size 200 mm (inner diameter)/25mm thickness at site over the single/multiple cable laid in the trench.
Transportation of cables in rolls with or without wooden drums (S&T Cables) from concerned store to the site of works.
Laying of S&T Cables (Signal/Quad/Power) in the excavated trench to Drawing No. CON/SK/T/5. Transportation and supply of 'U' clamps, anchoring of cable at every 10 mtrs interval with 'U' clamp on trench to Drawing No. CSTE/CON/CABLES/81. Transportation, supply and placing of 21 cable demarcating lead belt to Drawing No. CON/SK/T/6 punched at an interval of 30 mtrs. and wrapped round each cable throughout the cable route and also at every track/Road/ platform crossing as above specified in Technical Circular No. 2/1988 & 01/2010 issued by CSTE/SER and guarding the cables collecting empty drums with left over cable and return to the stores of stock holder.
Transportation including loading/ unloading of Optical Fibre Cable along with HDPE pipe from the stores of SSE/Store or from any store of SE Railway to the site with care and laying of 22 OFC as per procedure and returning empty cable drums with or without left over cable to the stores of SSE/Store. It includes supply and placing of warning & Detection tape orange colour of 100 mm. Wide printed in black as "CAUTION OFC CABLE" at every 1 meter interval (Minimum) and laid in the trench in station section and as directed by the Representative of Railway
Supply of 48 Fiber OFC Joint Closure similar to Specification No. RDSO/SPN/TC/68/2014 Rev 1.0 or latest. Inspection : Representative of Sr.DSTE/Adra.
Splicing of Optical Fiber Core and routing in joint closure/FDMS as per instruction of site Engineer.
Supply of PVC Insulated Multicore copper conductor Indoor Cable 40 Core x 1.0mm diameter as per Specification No. IRS:S-76/89 or latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of PVC insulated Single core Multi-strands Copper conductor of cable 1 x 6 26 Sq.mm (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: Representative of Sr.DSTE/Adra.
Supply of Cable PVC Insulated single core multistrand, unsheathed with plain 27 annealed copper conductor 16/0.2 mm diameter (0.5mm Insulation Thickness) Specification No. IRS:S-76/89 or latest. Colour of the cables may be Blue/Red/Grey/Green/Brown/Black/Yellow/ White. Inspection : Representative of Sr.DSTE/Adra.
Supply of Cable PVC Insulated single core multistrand, unsheathed with plain 28 annealed copper conductor 3/0.75 mm diameter (0.8mm Insulation Thickness) Specification No. IRS:S-76/89 or latest. Colour of the cables may be Red/Black and as decided by Railway. Inspection : Representative of Sr.DSTE/Adra.
Supply of Terminal block 6-way PBT, 25mm as per Specification No. IRS:S-75/2006 Rev. 2.0 or latest as per IRS Drg. No. SA-23756 Alt-3 or its latest amendments. Inspection : RDSO.
Supply of 2 conductor Knife disconnect terminal block i.e. Wago, Connection method: 30 Spring-cage connection, Cross section: 0.2 mm² - 2.5 mm², Nominal current: 16 A, Nominal voltage: 400 V, Color :- as per instruction of site engineer. Flammability rating according to UL 94-V0, confirming to Specification No. RDSO/SPN/189/2004, Ver.3 or latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of 4 conductor Knife disconnect terminal block i.e. Wago confirming to 31 Specification No. RDSO/SPN/189/2004, Ver.3 or latest. Connection method: Spring-cage connection, Cross section: 0.2 mm² - 2.5 mm², Nominal current: 16 A, Nominal voltage: 400 V, Color: as per instruction of site engineer. Flammability rating according to UL 94-V0,". Inspection : Representative of Sr.DSTE/Adra.
Supply of Steel Rail Carrier (Din Rail slotted) Size: 35mmx7.5mm as per Specification No. RDSO/SPN/189/2004, Ver.3 or latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of Endplate/End stop suitable for disconnect terminal as per RDSO/SPN/189/2004 or latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of Non-Deteriorating type low voltage electric fuse for Railway signalling, fuse with cylindrical cap without indication, cylindrical fuse as per Specification No. IRS:S-78/2006 or latest. Inspection : RDSO.
Supply of PBT fuse base as per Specification No. IRS:S- 75/2006 Rev. 2.0 or latest as per IRS drawing No. . SA: 23748 with alt 4 or its latest amendments. Inspection : RDSO.
Supply of Colour Light Signal, Multi Unit type Two Aspect complete but without lamp 37 holder, lenses & transformers as per IRS:S-26/64 and RDSO Drawing No. SA23003 A/M (Adv.) or latest. Mounting socket including its material shall be as per RDSO Drawing No. S 23005/M for post mounting on 140 mm outside diameter post. Inspection : Representative of Sr.DSTE/Adra.
Transportation, installation of 2-Aspect Signal Post for MACLS as per drawing no. Con/SK/T/12 or SEM-Drawing No. 19-D3 complete with signal units, base, ladder and other fittings, excavation of pit, erection of posts, casting concrete foundation thereof as specified in the note given in drawing, fixing of complete fittings of the signals with necessary earth screen protection arrangement including termination of cables, painting and lettering as required. Foundation Bolts of size 24 mm x 915 mm as per RDSO Drawing No. SA-116 A/M confirming to IS: 226 and IRS:S-10/78 Rev.8.
Supply of Colour Light Signal, Multi Unit type Three Aspect complete but without 39 lamp holder, lenses & transformers as per IRS:S-26/64 and RDSO Drawing No. SA23002 A/M (Adv.) or latest. Mounting socket including its material shall be as per RDSO Drawing No. S 23005/M for post mounting on 140 mm outside diameter post. Inspection : Representative of Sr.DSTE/Adra.
Transportation, installation of 3/4 - Aspect Signal Post for MACLS as per Con/SK/T/12 or SEM-Drawing No. 19- D3 complete with signal units, base, ladder and other fittings, excavation of 40 pit, erection of posts, casting concrete foundation thereof as specified in the note given in drawing, fixing of complete fittings of the signals with necessary earth screen protection arrangement including termination of cables, painting and lettering as required. Foundation Bolts of size 24 mm x 915 mm as per RDSO Drawing No. SA-116 A/M confirming to IS: 226 and IRS:S-10/78 Rev.8.
Supply of Cast Iron (Grade-20) Signal base 140 mm diameter tube Drawing No. S- 2011/M as per Specification No. IRS:S-10/78 & IS:210 or latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of Tubular (Seamless) Post for Colour Light Signal 5.5 meter Specification No. IRS:S-6/81 or latest to suit 140mmm dia. base. Inspection : Representative of Sr.DSTE/Adra.
Supply of Ladder 5.5 meter for Colour Light Signal as per RDSO Drawing No. SA- 23156 (Adv.) and Stage with Ladder foundation as per Drawing No. S-2033/M (IRS) as per Specification No. IRS:S-10/78 & IS:210 or latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of Shunt Signal Position Light type complete with base, post etc. as per Drg. No.SA- 23840 (Adv.) Alt '1', S-23203 and Drg. No. 23845(Adv.) for 90 mm dia. mounting socket as per Specification No. IRS: S-10/78 with Rev. 8 or latest. Inspection : Representative of Sr.DSTE/Adra.
Transportation, installation of Position light Shunt Signal as per Con/SK/T/12 or SEM 45 Drawing No. 19-D4 complete with units, base and other fittings, excavation of pit, casting of concrete foundation thereof as per note given in drawing, fixing in complete fittings of signal including termination of cables, painting and lettering as required. Foundation Bolts of size 20 mm x 305 mm as per RDSO Drawing No. SA-110 A/M confirming to IS: 226 and IRS:S- 10/78 Rev.8.
Supply of Offset bracket for Colour Light Main Signal Unit to fix on post of 140 mm outside diameter as per RDSO Drawing No. SA- 23080 (Adv.) Alt-1 and Specification No. IRS-S-10/78 or latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of Shunt Signal dependent type complete as per Drawing No. SA-23840(Adv) Alt.1, S-23023 with offset bracket to Drg. No. SA23080 Adv. Alt. 1 to suit 140 mm. dia post complete as per Specification No. IRS:S- 10/78 Rev. 8 or latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of Metallic A Marker/Calling On signal (CLS Type) unit as per Drawing No: SA 24351 (Adv.) and Specification No. IRS-S-10/78 and IRS:S-26/64. Inspection : Representative of Sr.DSTE/Adra.
Transportation and fixing of Calling ON Signals/ Dependent Shunt Signals / Illuminated 'A' / Illuminated 'AG' marker for MACLS on the erected signal post complete with marker including termination of cables, painting and lettering as required.
Supply of Metallic Junction route indicator unit 1 way (Without Lenses & Holder) as per Drg. No. RDSO SA 23401 suitable for LED Signal Lighting Unit & as IRS:S- 66/84 amndt-1 or latest.(Supply of LED Unit is not covered in this item). Inspection : Representative of Sr.DSTE/Adra.
"Transportation and fixing of Junction type Route Indicator with Route arm One way."
Supply of Metallic Junction route indicator unit 2 way (Without Lenses & Holder) as per Drg. No. RDSO SA 23402 suitable for LED Signal Lighting Unit & as IRS:S- 66/84 amndt-1 or latest.(Supply of LED Unit is not covered in this item). Inspection : Representative of Sr.DSTE/Adra.
"Transportation and fixing of Junction type Route Indicator with Route arm Two way."
Supply of metallic Junction route indicator unit 4 way (Without Lenses & Holder) as per Drg. No. RDSO SA 23403 suitable for LED Signal Lighting Unit & as IRS: S- 66/84 amndt-1 or latest. (Supply of LED Unit is not covered in this item). Inspection : Representative of Sr.DSTE/Adra.
"Transportation and fixing of Junction type Route Indicator with Route arm Three way."
Supply of Signal Number plate pressure sensitive Retro reflective type high intensity 56 grade white with imprinted 'Number/Alphabet/Arrow' in black/White of size as per SEM Drg.19-D10 (Sheet 6 to 7) with film thickness 0.3mm on ACP sheet with Clamp for Main/Shunt Signal made of MS Flat of size 30mm x 3mm with nut & bolt as per SEM Drg.No. 19-D10 (Sheet 9-10). Inspection : Representative of Sr.DSTE/Adra.
Supply of Signal Marker Retro reflective type high intensity grade white with 57 imprinted Arrow Marker in white on red background of size as per SEM Drg.19-D10 (Sheet 8) with film thickness 0.3mm on ACP sheet with Clamp for Main/Shunt Signal made of MS Flat of size 30mm x 3mm with nut & bolt as per SEM Drg. No. 19- D10 (Sheet 9-10). Inspection : Representative of Sr.DSTE/Adra.
Supply of Signal Marker Retro reflective type high intensity grade white with 58 imprinted 'A'/'G'/'C'/'P' in black of size as per SEM Drg.19-D10(Sheet 1 to 5) with film thickness 0.3mm on ACP sheet with Clamp for Main/Shunt Signal made of MS Flat of size 30mm x 3mm with nut & bolt as per SEM Drg.No. 19-D10 (Sheet 9-10). Inspection : Representative of Sr.DSTE/Adra.
Fixing of P/G/C/A/AG/IB Marker/Arrow marker/Signal Number plates with complete fittings as per site requirement.
Transportation, Installation, Wiring, Testing & Commissioning of LED Signals Lamps 60 for Main signals Lighting Unit (i.e. Red, Yellow, and Green) as per instruction of railway Engineer at the site. Note:- LED particulars such as aspect, make, type, Sr. No. etc. to be recorded in proper in proper register.
"Transportation, Installation, Wiring, Testing & Commissioning of LED Signals Lamps 61 for Subsidiary signals lighting unit (i.e. Route aspect, Shunt Signal, Calling on aspect, A marker etc.) as per instruction of railway Engineer at the site. Note: LED particulars such as aspect, make, type, Sr. No. etc. to be recorded in proper register."
Transportation, installation and painting with retro reflective tape of 62 SLB/BSLB/Legend/Stop Board etc. as per SEM Drawing No. 19-D4. This includes i) Excavation of pit of depth 900 mm, width 600 mm. ii) casting in the ratio of cement concrete mixture shall be 1:3:6 iii) foundation, (iv) Erection etc. Note: Supply of sighting board by contractor to be as per SEM Drawing No. 12-D1 or specified by Railway.
"Execution of Full Apparatus Case with pit, concrete foundation, surrounding earth work, erection, installation as per Drawing No. Con/SK/T/8 and wiring as per SEM Drawing No.19-D8 or as per direction of site engineer. Fixing of Hylam sheet strip of size approx. 925mmx100mmx3mm (including supply) with hole on both side for writing & terminal description, terminals, fuse blocks, relay and other accessories for signal/track circuit, termination of cable with number embossed ferrules, bunching of cables with PVC tape, earthing of cable armour as required. 63 Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anticorrosive paint and subsequent two coats of Aluminium paint outside and red oxide inside and lettering etc. This includes transportation of 25 mm/12mm Hylam sheet for shelf or as required and also includes minor modification in L/Boxes as per site requirement .The contractor shall supply of 4 no. of foundation bolts 22 mm dia. x 450 mm long with 2 flat spring washers, one nut is to be used for each set, sand for filling up cable pit inside the apparatus case and bolts, nuts, screws, MS Clamps for fixing equipment/cable. Note: - Part payment shall be released after completion of- (i) Foundation- 40%, (ii) Erection - 10%, (iii) Wiring, earthing, testing - 20%, (iv) Painting, writings - 10%, (v) Plastering, sand filling & etc. - 10%, (vi) Commissioning - 10%."
Alteration/modification in existing location boxes, fixing of equipments, cable 64 insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagram. This includes filling with sand and plastering the same. Note: All the sundry materials except that included in supply schedule shall be supplied by the contractor.
Supply of MS Flat Plate Strip (Specification no. 226 STD or latest 35 mm x 6 mm thick for earth connection to Signal post, L/Box etc. Inspection : Representative of Sr.DSTE/Adra.
Supply of Pipe lock with key ring size inside dia. 40.5mm, outside dia. 60mm. Thickness 20mm, lock length 65mm. Inspection : Representative of Sr.DSTE/Adra.
Supply of Composite Relay Rack/Q series Relay Rack as per Drawing No. SK/DRG/OL/SER/192, Sheet 1 or 2 or latest and must be powder coated of stone grey colour. Inspection : Representative of Sr.DSTE/Adra.
Transportation, Grouting/erection, wiring as per approved wiring diagram of 19" relay rack/Composite/Q- Series Relay Rack with subsequent alteration (with 3/4 X 9" anchor bolts with one nut and one washer per bolt & D-bracket & 60mm insulator), fixing of M.S. ladder as per requirement for rack to rack connection, CTR and control panel, fixing of plug boards, relays, terminal blocks, 68 terminals, filter units, tag blocks, fuses, bus bars, shelves, strips, 6mm Hylam sheet of required length for writing terminal description etc. fixing and termination of cables on the relay racks with number embossed ferrules, bunching of cables with PVC tape, earthing of cable armour including painting and lettering. Wiring and testing of complete relay rack accommodating all relays as per wiring diagram. All materials such as eyelets, M.S ladder, Hylam sheets, ferrules, trough etc., if required for modification of rack shall be supplied by the contractor and to be carried out at site within the cost.
Supply of MS Cable termination Racks (CTR) with full size of 6 mm thick Hylam sheet as per Drawing No. SK/DRG/OL/SER/197 or latest and must be powder coated of stone grey colour. Inspection : Representative of Sr.DSTE/Adra.
Transportation, erection, fixing, installation and commissioning of Cable Termination rack (CTR), fixing of MS Wiring ladder from relay rack to CTR, and on to top of the CTR- including supply of 3/6mm Hylam sheet of required size for fixing terminal blocks & writing terminal description, termination of cables, bunching of cables by PVC tape and earthing of cable armours, painting, lettering as required. The contractor shall draft terminal analysis chart on the white bond paper of appropriate size & supply wiring materials like eyelets of sizes, trough, condensers and resistances as per required value, HV protection cover with fixing top caps and danger symbol, 70 soldering material of approved quality etc. shall be supplied by the contractor. Cement of approved brand, stone chips 5/8" and sand as required for mounting CTR, Sand for filling of cable pit and other required masonry work, Sundry materials such as MS plate/angles, MS wiring ladders as per approved Drawing, , Anchor bolt 5/8" X 9" with nut and washers -4 No., Nickel plated screws 2BA X1" with nuts and washers for fixing Hylam sheet, numbers embossed ferrules 2.5 sq. mm, PVC bunching tapes and buttons, paint synthetic enamel of smoke grey colour for painting, MS clamps with bolts and nuts of sizes, D-bracket and 60mm insulator, for fixing cables, screws of sizes as required shall be supplied by the contractor. Cables should be routed properly through ladder. All the materials required for installation, wiring, testing and commissioning as per the approved wiring diagram except the materials included in supply schedule shall be supplied by the contractor.
Supply of Tag block 200 way/160 way with PVC covers as per Specification No. IRS: S- 77/2006 with Rev.1.0 or latest & Drawing No. SA-24751 & 52. Inspection : Representative of Sr.DSTE/Adra.
Supply of Negative Bus Bar 20 mm X 5 mm thick made of copper bar with brass screw & washer (The bar and screw should be nickel plated) minimum length of one piece is to be 0.3 m. Inspection : Representative of Sr.DSTE/Adra.
Supply of Data logger system for Railway S&T Installations with 1024 Digital and 64 Analog inputs as per Specification No. IRS:S-99/2006 (Amdt-3) or latest with power supply 73 arrangement (batteries and charger), fault diagnostic software for failure analysis , modem card, as per technical specification. Its includes:- CMU (i3 or latest with 256 GB SSD or better) with UPS (minimum 6 hrs. battery backup) and Printer- 01 No. Magnetic door lock coil to be supplied along with equipment. Inspection : RDSO.
Installation, Wiring, Testing, Validation and commissioning of Data logger with 1024 Digital and 64 Analog inputs with modem as per Specification No. IRS:S-99/2006 (Amdt-3) or latest.
Supply of PVC Switch Board Cables 05 pair / 0.5 mm conductor dia. as per TEC specification GR/WIR-06/03 of march 02 or latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of PVC Switch Board Cables 10 pair / 0.5 mm conductor dia. as per TEC specification GR/WIR-06/03 of march 02 or latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of PVC Switch Board Cables 20 pair / 0.5 mm conductor dia. as per TEC specification GR/WIR-06/03 of march 02 or latest. Inspection : Representative of Sr.DSTE/Adra.
Installation, Testing and Commissioning of SMPS based Integrated Power Supply System (Large-IPS) as per Specification No. RDSO/SPN/165/2012 Ver. 3.0 or latest and conforming to SE Railway Drawing No. SK/DRG/OL/SER/253, dated 23.01.19.
Transportation, grouting and laddering of Integrated Power Supply (IPS) System including termination of power & signalling cables on Hylam sheet fixing on MS angle by contractor 79 on wall in panel room, IPS room of adequate size duly fixed with galvanized MS clamp, ladder, painting & lettering. Note: Transportation of batteries, electrolyte, bolts & nuts, screws, trough etc. and other sundry materials required for the above work shall be supplied by the contractor as required. The IPS to be commissioned by the OEM.
Transportation and installation of Electric point machine including lubrication and MS plate fixed on concrete sleepers complete with fixing of anti-theft cover, crank handle key interlocking arrangements Junction boxes, ground connections including smithy works, insulation of 80 MS plate on which the point machines to be fixed from the gauge tie plate involving riveting/welding of angle cleats, termination of cables, preliminary adjustment of operation of points by crank handle, wiring, painting and lettering as required. Drilling of holes for fixing of switch extended bracket and leading stretcher bar.Note:- (i) All the required nut-bolt, washer, MS-plate for anti-theft, eyelets, etc. for fixing of point machine to be supplied by contractor.(ii) All released materials shall be returned to concern Store.
Supply of Electric key transmitter (EKT)/Rotary key transmitter (RKT) as per Specification No. IRS:S-21/2001 Rev 1.0 & Drawing No.SA-22601 or latest with the keys and wards nos. will be per instructions given by site Engineer in charge. Inspection : RDSO.
Transportation, installation and wiring of Rotary key transmitters/KLCR on Hylum 82 sheet board including wiring & fixing of push button bell switch on Hylum sheet of 12mm including termination, painting & lettering. The sundry materials such as Hylum sheet, push bell switch etc. to be supplied by contractor.
Supply of Key Lock - 'E' Type with key as per RDSO Drg. No. SA-3376/M, Alt-2(Lock) & SA-3377 (Key), and Specification No. IRS: S 30-64 Rev 0 and IRS S-10. Ward No. shall be as per instruction of Railway. Inspection : RDSO.
Installation, testing and commissioning of track circuit on Straight Portion of Track (without involving points and crossings) as per Drawing No. SK/DRG/OL/27 and track bonding plan including drilling of 9/32"hole on Rails, provision of bonding, Glued Joints, fixing and painting of 84 Track Lead Junction Boxes, provision of tail cable terminations, Track lead wires, Jumper wires, terminals, track feed set (Track Charger, Adjustable Resistance, choke coil, fuses, battery etc.) and also lettering/ numbering of track lead junction boxes, block joints and track circuits. This also includes transportation of all materials required for the above installation. Note:- Track feed set, bonding wires, TLJB, channel pin, tail cable to be supplied by Railway.
Installation, testing and commissioning of track circuit on Point & Crossings as per Drawing No. SK/DRG/OL/27 and track bonding plan including drilling of 9/32"hole on Rails, provision of bonding, Glued Joints, fixing and painting of Track Lead Junction Boxes, provision of tail cable 85 terminations, Track lead wires, Jumper wires, terminals, track feed set (Track Charger, Adjustable resistance, choke coil, fuses, battery etc.) and also lettering/ numbering of track lead junction boxes, block joints and track circuits. This also includes transportation of all materials required for the above installation. Note:- Track feed set, bonding wires, TLJB, channel pin, tail cable to be supplied by Railway.
Supply of Track Feed Battery Charger as per Specification No. IRS: S-89/2013 Ver.1.0 or latest with input 110V AC, 50 Hz, 10A to charge lead acid cell battery for 1/2/3/4 cells of 80 AH. Inspection : RDSO.
Supply of Choke Coil for single rail track circuits on 25 KV 50 H z A C electrified sections B-Type Choke as per Specification No. IRS: S-65/83 (Amdt 3) or latest. Inspection : RDSO.
Supply of Fixed Type Track Feed Resistance (Porcelain Base, Phenolic, Moulding Base) 0-30 Ohm (with tapping at 2, 4, 8 & 16 Ohm) as per RDSO Drawing No. SA- 20163/M and Specification No: IRS:S-23 or latest. Inspection : RDSO.
Supply of Track lead Junction Box (TLJB) made of fiber reinforced plastic RDSO 89 drawing No. SA 20101/M (IRS) or SI-10272 as per Specification No. RDSO/SPN/151/1997 or latest.1 way 60mm PBT terminals & MS angles are to be supplied by the contractor. Inspection : Representative of Sr.DSTE/Adra.
Supply of Wire I.G. 8 SWG (4.064mm Dia.) for Track Circuit Bonding as per Specification No.IS:279/81 or Latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of Channel Pins (Single groove for bonding Track Circuiting wires) of 7mm dia. for 4mm dia. bond wire as per Drawing No. S-69/M as per Specification No. IRS: S17-75 Rev 3 & IS: 1573-70 or latest. Inspection : Representative of Sr.DSTE/Adra.
Supply of Insulated galvanized flexible stranded wire rope 7x7 construction, 19 mm 92 circumference, Tensile Strength 125-140 Kg. per sq.mm Specification No. IRS:S- 3/61 or latest wrapped with Extruded jacket of PVC, thickness 2 mm. Color will be decided by site incharge. Inspection : Representative of Sr.DSTE/Adra.
"Transportation, installation and charging of Secondary Cell 2 V (lead acid type) and preparation of electrolyte for lead acid cells. Charging to be done as per OEM's instruction with 93 uninterrupted power supply in presence of Railway representative. After charging, it should be kept the dedicated location as per use. Note- If power is not available at site of work, charging may be done at nearby location as per convenience of the railway. This includes transportation of uncharged cells at the site of charging, supply of acid, distilled water at the site of charging and transportation of charged cells to the site of work. 2 Volt 80AH"
Supply of Class B & C Surge protection Device (SPD) - Type I & II with Visual Indication and Potential free contact to remote monitoring as per Specification No. RDSO/SPN/165/2012 Ver 3.0 94 or latest and IEC standard 61643 for Single line 230V AC application with handling Lightning surges of 10/350 microseconds and Switching surges of 8/20 microseconds .One Set consists of 3 nos. of SPD (2 No. of B Class (L-N, N-E) and one no. of C Class (L-N) all enclosed in a Box with KEMA or VDE certified as per latest IEC 61643-11-2011 Standard. Class B &C Surge protection device required with Three modules only. Inspection : Representative of Sr.DSTE/Adra.
"Supply of Low Maintenance Lead Acid (LMLA) Secondary Cells for S&T installations made of hard rubber container and with nominal voltage 2 volts as per Specification No. IRS-S- 88/2004 Ver. 1.0 or latest. 80 AH".Inspection:RDSO.
Supply & transportation of Single Section Digital Axle Counter phase reversal type as per Specification No. RDSO/SPN/177/ 2012 Ver.3 or latest without tool kit. Inspection: RDSO.
Installation, Testing & Commissioning of Single Section Digital Axle Counter phase reversal type as per Specification No. RDSO/SPN/177/ 2012 Ver.3 or latest without tool kit.
B-NON SOR ITEMS : Provision of New Electronic Interlocking work at
Supply, transportation & installation of Power Terminal 100 Amps. Inspection : Representative of Sr.DSTE/Adra. Above/
C-Supply & Installation EI Items 26435607.26 Below/P
Installation, wiring, testing (FAT & SAT) and commissioning of EI System with 'Hot Standby' architecture as supplied above in 1 above. It includes transportation of material from consignee's depot to the site, erection and grouting of EI Relay Racks, fixing and wiring of all the 2 interfacing relays (Vital & Non-Vital),installation and wiring of Microprocessor equipments, interface equipments, power supply equipments and all other associated accessories to make complete EI system to be functional. Note: (i) Technical Requirements are attached with tender document (ii) Contractor has to arrange simulator/simulation testing panel for testing and commissioning by Selection Table and Square Sheet for each Signalling function.(iii) Installation, wiring, testing and commissioning of EI system will be done by OEM after following all the guidelines/directives issued by RDSO from time to time. For Station with Vital Bit (151 to 400).
Item Breakup - C-Supply & Installation EI Items
Per For subsequent Vital Bit (from 81 to 150). Functional Vital Bit
Per For subsequent Vital Bit (from 151 to Functional 400). Vital Bit Total 25422669.30
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .