Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 107 2 AMPA MANOR IST FLOOR NELSON MANICKAM ROAD AMINJIKARAI CHENNAI 0 600 029 NO 107 2 AMPA MANOR 1ST FLOOR NELSON MANICKAM ROAD AMINIJIKARAI AMINJIKARAI | Admitted-Finance |
| 4 | Admitted-Finance 7 91 KOTTARAPATTI PATHALAPETTAI POST TIRUCHIRAPPALLI TAMIL NADU 620013 | TIRUCHIRAPPALLI | TAMIL NADU | 620013 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹49,966
Closing Date
21 Feb 2022, 3:00 pmClosed
The Assistant Engineer/Electrical, EMD
NIT Tiruchirappalli
Providing power supply to newly proposed ductable Air Conditioners for smart class room at orion building
2022_NITT_670604_1
NITT/EMD/EE/AEE/Tender Notice/ Enq.No.01/21-22
Open Tender
Electrical Works
Supply
120 days
NIT Tiruchirappalli
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹49,966
Yes
3 Mar 2022
31 Jan 2022
22 Feb 2022
31 Jan 2022
21 Feb 2022
31 Jan 2022
Amount
MCCB, MCB & DB'S
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Triple pole and neutral
Supplying and fixing of following rating,Three/four pole,415 volts,Isolator/MCB in the existing MCB/DB complete with connections,testing and commissioning erc.as required.
Four Pole 40-63A MCB
EARTHING
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
MV CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
HT CABLE LAYING
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 120 sq. mm and upto 400 sq. mm
MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3Y X 240 sq. mm (62mm)
3Y X 300 sq. mm (70mm)
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
HV CABLE JOINTING & END TERMINATION
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
Supply and fixing of 3 CORE 11KV, 240 sqmm Terminal protector right angled cold applied boots for Compact RMU units etc as required.
MISC. CIVIL ITEMS
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required
63 mm dia (OD-63 mm & ID-51 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
Foundation Works
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources).
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for all kinds of soil
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse sand)
FINISHING
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
CHAIN LINK FENCING ARRANGEMNT FOR VCB YARD.
"Providing GI wire mesh chain link fencing around the outdoor Sub-Station Building complete with adeuqateM.S.Channel of size 75 mm X 40 mm LC and shall have ironbracing of the angle iron frames. The upper parts shall be bend to the required degree and shall have four lines GI barbed wires. The GI chain link fencing shall be such that no stray dog etc. will be able to enter the switchyard.Frame work of gates of the switchyard shall be made up of minimum 2"" dia ( n.b.) M.S. pipe of 'B' class and the GI chain link fencing shall be used to enclose the pipe frame work with angle iron of iron bracing. The gates shall have a locking arrangement with providing 6 lever type "" Godrej"" make lock. The minimum height of fencing is 2.0 mtrs. above ground level. The distance between M.S.Channel support is minimum 2.0 meter and one angle iron ( 35 x 35 x 5 mm ) should be provided on top of chain link fencing around the switchyard and one angle iron (35 x 35 x 5 mm) just touching the ground level / wall around the switchyard. The complete chain link fencing work shall be painted with two coats of primer and two coats of alluminium paints. Brick / bolder massonry work I/c plaster shall be provided of size 300 x 400 mm around the switchyard except door entry. After erection of frame, angle iron and jali, wire mesh are painted with red paint and white aluminium paint. " Measurement to be taken only for the wiremesh area and shall be deemed to be included the Channel which is grounted in ground and Gate of size 2.5 mtr wide.Fencing shall be as per drawing.(The measurement shall be done on running meter basis).
SOLAR PHOTOVOLTAIC POWER PLANT
Testing and Commisining
Supplying and filling of Transformer oils as per the IEC 60296
Erection of Transformer/Genset/Control panels.
Transportation, Installation, testing and commissioning of 250kVA transformer with required plinth area construction, complete servicing of 250kVA transformer with following testing of insulation resistance, winding resistance, ratio test, vector group test & gasket replacement and submission of reports to the engineer in charge also replacement of faulty equipment etc. as required. Note: 1. Transformer will be supplied by EMC, 2. Crane arrangement & transportation will be contractor scope, 3. Plinth area of transformer to be constructed with size of 1500x1000x700mm with necessary excavation, sand filling, PCC filling, brickworks & plastering works. Also required channel arrangement for locking of transformer wheel.
HT RING MAIN UNIT OUT DOOR
Augmentation of the existing 11KV Outdoor Ring Main System by extending / adding 1No. of SITC of 11kV, 3 phase, 630A, 20kA/3 sec, 50Hz, totally SF6 Gas Insulated OUTDOOR Compact switch gear with motorized Vacuum Circuit Breaker: V+ (Extendable type) complete with overload and earth fault protection by self-powered relays. The panel should be with suitable ratio ring core type protection CTs etc., and as per the technical specifications as specified in tender documents. (The RMU shall be the same make of Existing RMU) (Note: The scope of work includes providing necessary Foundation as prescribed by the Manufacturer).
FABRICATION OF CUBICLE BOARDS/LADDER/SOLAR STRUCTURE
Fabrication, supply of out-door feeder pillar type made out of not less than 2.2 mm thick MS sheet and angle iron base frame with hinged door on both side and gowden locks welded on the door i/c painting connection inter-connection etc. as per CPWD specifications (Part IV & V) of following size and providing and fixing following switch gears with cable entry boxes for both incoming and outgoing cables termination, glands, interconnection, connections powder coated painting, earthings , including of all erection, Labelling of incoming and outgoing feeders & transport charges etc., as required. The panel drawing should be submitted before execution of the works. (Make: L&T/Legrand/Schneider/Siemens). "Specification for Microprocessor based MCCB Conforms to IS/IEC 60947-2 & IEC 60947-2, Ics=100% of Icu,Suitable for Isolation,Adjustable Overload from 0.4-1.0 X In,Adjustable short circuit from 1.5-8XIr, Inbuilt Instantaneous protection,Provisional of thermal memory : ON/OFF,Variable trip class at 7.2 lr & 6 lr, Front LED indication of Over load (Ready, Over load pre-alarm & Overload),Provision of Manual, Rotary or motorized versions,Wide range of snap fit internal and external accessories "Specification for Thermal Magnetic MCCB Conforms to IS/IEC 60947-2 & IEC 60947-2, Ics=100% of Icu,Suitable for Isolation,Adjustable Overload from 0.8-1.0 X In,Adjustable short circuit from 6-10 XIn, Provision of Manual, Rotary or motorized versions,Wide range of snap fit internal and external accessories
Supply, Installation, Testing and Commissioning of Essential panel with size 1900mm x 1500 mm x 500mm deep (Nominal) a) 4 strip copper bus bars of suitable capacity, b)Incomer 400A,4P,50kA MCCB with thermal magnetic release and extended rotary handle - 1No, c) 63A,3P & N, 36kA MCCB with thermal magnetic release and extended rotary handle - 6Nos, d) Dummy Compartment suitable for 63A MCCB-7Nos (Cu. Bus provision must be provided upto switch position), e) Multifunction meter class 0.5 with RS 485 port -1No, f) CT'S-3Nos, g) 2A Control MCB -3Nos, h) R,Y,B indicators-3Nos i) Three phase indicator lamps controlled by single Push button arrangement using contactor-1No with necessary wiring etc. as required.
Panel Boards shifting/dismantling
Transportation, Installation, testing and commissioning of LT panel with required plinth for panel erection, servicing and necessary crane arrangement & channel provision etc. as required.
Supplying of Cables.
Supplying of following size ISI marked PVC insulated and PVC sheathed aluminium grade with armoured as required.(Make:Finolex,Gloster,Polycab and Havells with 18 months warranty from the date of supply)
3½ X 240 Sq mm
3½ X 300 Sq mm
4x16 sq mm
4x25 sq mm
Supplying and fixing of following size ISI marked PVC insulated and PVC unsheathed copper single core and multi-core shaethed bright annealed bare copper flexible cables for voltage grade 1.1 KV grade as required.(Make:Finolex,Gloster,Havells and Polycab)
4x6.0 sq mm
Supplying of following size ISI marked PVC insulated and PVC sheathed aluminium conductor H.T cable of 11 KV grade as required. (Make:Havells,Finolex,Gloster and Polycab)
3X 240 Sq mm
Adaptor box
Cable adaptor box
Supplying and fixing of M.S Box with size of 300x250x150mm with powder coated paint and 4way 32A terminal connector (SS bolt type connector) etc as required suitable for out door.
Supplying and fixing of M.S Box with size of 450*250*150mm with powder coated paint and din rail provision of 4Pole MCB 3 Nos (SS bolt type connector) etc. as required suitable for out door.
TOOT MNE TECH PRIVATE LIMITED
ALFA DEAL PRIVATE LIMITED
POWER ELECTRICAL WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .