Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 1ST FLOOR S V J COMPLEX MALAYANKIZH PO TRIVANDRUM | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹3 L
EMD Value
₹7,500
Closing Date
15 Nov 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
secratary
karuvarakundu gramapanchayath office, karuvarakundu po, 676523, malappuram dt
karuvarakundu gp 2022-23 plan- kannath ministadium flood light instalation.
2022_DP_525640_1
6/22
Open Tender
Electrical Works
Item Rate
karuvarakundu
Please refer Tender documents.
6 documents required · 6 mandatory
₹708
Yes
₹7,500
Yes
18 Nov 2022
7 Nov 2022
18 Nov 2022
7 Nov 2022
15 Nov 2022
7 Nov 2022
7 Nov 2022 - 15 Nov 2022
Amount
Installation of Flood Lights in Kannath mini stadium Electrification
Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters
Supply Conveyance, installation, testing and commissioning of 200 W LED Flood light output greater than 105 lumen/W 4000-6000 K with IP 65 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 3 core 2.50 sq mm
upplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
Supply and fixing Danger notice board of size, 125 x 75 mm
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
Supplying and Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB-4537 )[450x375x200] and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required
Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 63/50 mm or nearest size
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG)
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 2.65 mm (12 SWG)
Supply and providing 12x3mm brass nut and bolt etc. as required.
Supply and installation of hot press junction box of GS-JB-2014 size 200x140x95 mm pole mounted jee/cut out box PVC make fixed on /concealed on existing cement concrete piller including providing 4way plastic connector and provision for fixing HRC fuses / MCB and N/L with FRP shroud inside the syntex box and giving connection as required.
Charges for preperation of KSEB test Report for submitting to the concerned KSEB section office
BOSS LIGHT
stage.html
html • 0.02 MB
finance_757505.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .