Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.1 LAccepted-AOC MATHURAPUR SONARPUR KOLKATA 700150 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700150 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹49.3 L+₹22,236 (0.45%)Rejected-Finance MIA GARAGE BUILDING 1ST FLOOR HILLCART ROAD DIST SILIGURI PIN 734401 | SILIGURI | SILIGURI | WEST BENGAL | 734401 | L2 | Rejected-Finance Higher Bid | |
| 3 | L3₹50.8 L+₹1.7 L (3.38%)Rejected-Finance | L3 | Rejected-Finance Higher Bid | |
| 4 | L4₹52.0 L+₹2.9 L (5.95%)Rejected-Finance | L4 | Rejected-Finance Higher Bid | |
| 5 | L5₹55.7 L+₹6.6 L (13.4%)Rejected-Finance | L5 | Rejected-Finance Higher Bid |
Tender Value
₹60.1 L
EMD Value
₹1.2 L
Closing Date
17 Jul 2021, 1:00 pmClosed
EE, South 24 Pgs Elect Divn
57/2 DH Road
Electrical Installation work for Newly constructed PICU at Diamond Harbour Govt. Medical College and Hospital Old Building, Dimoand Harbour, South 24 Pgs.
2021_WBPWD_334448_1
WBPWD/EE/S24PED/eNIT03/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Wise
60 days
Diamond Harbour
Please refer Tender documents.
3 documents required · 3 mandatory
₹1.2 L
South 24 Pgs Elect Divn
7 Jan 2022
26 Jun 2021
19 Jul 2021
26 Jun 2021
17 Jul 2021
6 Jul 2021
5 Jul 2021
Amount
Dismantling the exiting worn out electrical installation as per direction of E.I.C.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & nsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish.[only PVC Rigid Conduit on ceiling and remaining portion concealed](Avg run - 8Mtr
Do ---- do – to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular plug socket & Modular switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on Board.
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.Make - GI Board - L&T , Switches & socket : (Legrand -Arteor/Myrius (/(Crabtee-Verona) or as per direction of EIC)
Supply & Fixing 240 V, 16 A, 6 pin Modular type plug socket -2nos (Brand approved by EIC) with 16A Modular type switch-2nos, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make - GI Board - L&T , Switches & socket : (Legrand -Arteor/Myrius (/(Crabtee-Verona) or as per direction of EIC)
Supply & Fixing 240 V, 16 A, 6 pin Modular type plug socket - 1no(Brand approved by EIC) with 16A Modular type switch-1no, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make - GI Board - L&T , Switches & socket : (Legrand -Arteor/Myrius (/(Crabtee-Verona) or as per direction of EIC)
Supply & Fixing 240 V, 6 A, 5 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make - GI Board - L&T , Switches & socket : (Legrand -Arteor/Myrius (/(Crabtee-Verona) or as per direction of EIC)
Supply & Fixing 240 V, 2x 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make - GI Board - L&T , Switches & socket : (Legrand -Arteor/Myrius (/(Crabtee-Verona) or as per direction of EIC)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), incl. S&F 1no 240 V, 16 A, 3 pin Modular type plug top (Brand approved by EIC) and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire as per GS.(Make - GI Board - L&T , Switches & socket : (Legrand -Arteor/Myrius (/(Crabtee-Verona) or as per direction of EIC)
Supply,& Delivery of 250V Timer DB [equivalent of 8 way SPN Double Door DB in size)] with steel sheet enclosure double door, phosphitised powder coated, neutral bar, Din Rail with IP-43 protection comprises with 1 no. 20A/25A DP MCB ('C' Curve, 10 kA,), 1 no. 24 hours programmable Time Switch (Make:- Legrand/Havells/Siemens) with minimum switching time of 15 miniutes and 1 no. 18A/25A 2 pole contactor(Make:- Legrand/Havells/Siemens) complete with AC Starter (Make:- Legrand/Havells/Siemens) with Inner-Outer Plate & internal wiring by suitable size of copper wire including 1 no. Auto Mannual bypass Toggle Switch and provision for earthing attachment including LED indication light for running condition.(For 1.5 / 2.0 TR Single operation). (Make:- Legrand/Havells/Siemens) with locking arrangement.
Supply & Fixing of 230Volt 1200mm sweep AC ceiling fan with blade, canopy including all fixing material etc. (Make- Orient-New Breeze/Orient-Summer Cool/Crompton-Aura Primium / Crompton-Smart Breeze or as per direction of EIC)
Supply & Fixing 450 mm sweep, 230V, 50Hz, A.C. wall bracket fans including connection by 1.5 sq. mm. P.V.C. / Cu wire ( Make - Orient Electric, Make - Tornado wall - II, as per direction of EIC.
S & F 300mm.dia heavy duty exhaust fan with louver shutter ( Make- EPC) after cutting wall and mending good the damages as to G.S.
Supply and drawing 1.1 KV grade 4x16sq.mm +2x4 sq.mm single core PVC insulated & unsheathed copper wire in 19mm dia Polythene pipe recessed in wall from Nearest LT panel to HTPN DB (Make-Havells/Finolex/Polycab/KEI)
Supply and drawing 1.1 KV grade 2x6sq.mm +1x4 sq.mm single core PVC insulated & unsheathed copper wire in 19mm dia Polythene pipe recessed in wall from HTPN to SPN DB (Make-Havells/Finolex/Polycab/KEI)
Supply and drawing 1.1 KV grade 2x4 sq.mm +1x1.5sq mm single core PVC insulated & unsheathed copper wire in 19mm dia Polythene pipe recessed in wall. (Make-Havells/Finolex/Polycab/KEI)
Supply and drawing 1.1 KV grade 2x2.5sq.mm +1x1.5sqmm single core PVC insulated & unsheathed copper wire in 19mm dia Polythene pipe recessed in wall for PP point & computer Pts. (Make-Havells/Finolex/Polycab/KEI)
Supply and drawing 1.1 KV grade 3x1.5sq.mm copper wire in 19mm dia Polythene pipe recessed in wall for separate 2x6A plug points. (Make-Havells/Finolex/Polycab/KEI)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc. including supplying sockets, tapes
a) 4x16 sq.mm + 2x4Sqmm
b) 2x6 sq.mm + 1x4Sqmm
c) 2x4 sq.mm + 1x2.5Sqmm
d) 2x2.5 sq.mm + 1x1.5Sqmm
S&F 415V, 6 Way VTPN DB Double Door incorporated with 1No. 100A 4Pole 25kA DPX3 MCCB as incomer & 6 Nos. 63A TP MCB.(Make- Seimens/Legrand/Havells) as per G.S.
S&F 415 V, Horizontal type, TPN MCB DB ( 4-way) with SS enclosure double-door with IP-42/43 protection with Four Pole Isolators as incomer and SPMCBs ('C' Curve, 10 kA) as outgoing on the surface of the wall with fastners & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS. INCOMING-63 A FP Isolator -1 No. OUTGOING-32A SPMCB-12 Nos. ( Make :Make:- Legrand/Havells/Siemens)
S&F 415 V, Horizontal type, TPN MCB DB ( 6-way) with SS enclosure double-door with IP-42/43 protection with Four Pole Isolators as incomer and SPMCBs ('C' Curve, 10 kA) as outgoing on the surface of the wall with fastners & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS. INCOMING-63 A FP Isolator -1 No.OUTGOING-32A SPMCB-18 Nos. ( Make :Make:- Legrand/Havells/Siemens)
S&F 250 V,( 6-10)A per way, SPN MCBDB (2+12) way with SS enclosure double-door(Ivory White with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing,on the surface of the wall with fastners & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS. INCOMING-40A DP IsolatorOUTGOING 12 Nos. 6-10A SPMCB ( Make :Make:- Legrand/Havells/Siemens)
Supplying and fixing double-door (2+8) way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. incl. S&F 250V of 40Amp. DP MCB Isolator-1 no. & 8nos 6-32Amp. SP MCB (Make :Make:- Legrand/Havells/Siemens)
Supply and laying 1.1KV Gr. 4 core 70 Sq. mm. XLPE/PVC Ar.Al. cable surface on the wall along with 2x10 S.W.G. G.I. wire as per G.S (From DGLT Panel to PICU LT Panel) (Make-Gloster//Polycab/KEI)
Supply and laying 1.1KV Gr. 4 core 50 Sq. mm. XLPE/PVC Ar.Al. cable concealed in wall along with 2x10 S.W.G. G.I. wire as per G.S (From existing SNCU LT Panel to PICU change over switch)(Make-Gloster//Polycab/KEI)
S & F compression brass cable gland with finishing the ends of the following cable by crimping method as per G.S.
A) 4 core 50 Sq. mm.
B) 4C core 70 Sq. mm.
S/F 415V,160Amp On-load Changeover with sheet steel enclosure on angle iron frame on wall (make L&T/Havells/HPL) as per GS
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level incl.earth excavation & restoring surface duly rammed (soft soil) By TATA-Medium GI pipe
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. (GI flat joint must be electric welding)
Supplying and fixing Changeover switch with Sheet Steel enclosure on angle iron frame on wall withnuts bolts etc. 63AFP 415V (make HPL/Havell/Standard)
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection.
S & F surface mounted single Industrial batten (MAKE- Philips, Cat No-TMC 501 PxT-LED 20W P3241) with 1no ESSENTIAL LED tube 1200mm 18W865 T8 AP I (Make - Philips) suspended from ceiling up to 25 cm. with 2 Nos. 20 mm dia EI conduit (14 SWG) supports fixed with with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of 2 x 1.5 Sq.mm of 1.10 mt. length PVC insulated wire and mending good damages to original finish and painting etc. as per G.S. and direction of E.I.C.
S & F surface mounted double Industrial batten (MAKE- Philips, Cat No-TMC 501 PxT-LED 20W P3241) with 2 nos ESSENTIAL LED tube 1200mm 18W865 T8 AP I (Make - Philips) suspended from ceiling up to 25 cm. with 2 Nos. 20 mm dia EI conduit (14 SWG) supports fixed with with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of 2 x 1.5 Sq.mm of 1.10 mt. length PVC insulated wire and mending good damages to original finish and painting etc. as per G.S. and direction of E.I.C.
Supply & Delivery of Extension board icluding cable drum which reel the 25mtr 3 Core 1.5 Sqmm Cu. Cable(Make- Finolex/Havells/Polycab/KEI) .There should be required below materials - i) DPMCB C Type - 16A, - 1no, ii)5/15 A 3pin socket - 2 Nos, Indiactor light- 1no,iii) Heavy duty cable reel fitted with flexible and easy to wind cable, tough body with sturdy construction, strong steel stand, zinc plated for extra rust resistance.make - brilliant or as per direction of EIC.
Supply & fixing the spot light - 50W, PHILIPS 53090/ crompton- CDR-215-50-40-SL-NWH/havells
B) LT PANEL Supply and Installation of wall cum floor mounted L.T. cubical type fully compartmentalized distribution panel board , having rigid and self supporting structure fabricated with 18 SWG CRC sheet with M.S. angle iron frame (main frame with 50 x 50 x 6mm angle and each compartment with 40 x40x 6 mm angle iron). The base of panel should be made with 75 mm x 40mm x 4.4 mm M.S. channel . Each compartment will be providing with hylam board at back side. Incoming Arrangement : A) 415V, 250A TPN Switch Disconnector Fuse unit with HRC Fuse ( Make- L&T,Front handle )- 1 No. COS ( 250A) make - L & T - 1No Bus Bar Section : 500V, 315 Amp capacity 99.9% -99.5% electrolytic tinned 4 bar copper bus bar having size of flat [4x(40 mmx 5 mm)] mounted on non- hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes ( Red , yellow , blue & black) for phases & neutral identification - 1 Set.[Cable alley should be more than 1 and 1/4 th Feet for sufficient clearance for quality work.Incomer chember work space min. 1 &1/2 Feet feet to direction of cable entrance Outgoing Arrangement : a1) 415V 125A TPN Switch Disconnector Fuse unit with HRC Fuse ( Make- L&T,Front handle )- 2 Nos .a2) 415V 63A TPN Switch Disconnector Fuse unit with HRC Fuse ( Make- L&T,Front handle )- 8 Nos a3) 240V 32A DPMCB- 6 Nos (Inside lighting )
C) SITC OF ROOM SPLIT AC SITC of indoor & outdoor unit of High-wall Split Air Conditioner having following specification: Cooling capacity not less than 6400 Watt Minimum ISEER - 3.5, BEE levelling - 2-Star or more Capacity - 2.0 TR IS Compliance - IS-1391 Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply - 230V, 50Hz (±tolerance as per applicable standard) The scope of work is also includes supply of following: (i) Necessary refrigerant Cu line with nitrile rubber insulatio - 3 Mtr. (ii) Necessary Copper cable (FRLS type, Make - Finolex, Havells/Polycab) - 3 Mtr. [Make: O.General / Mitsubishi Electric / Mitsubishi Heavy Duty]
S&F angle structure/Pre-fabricated angle with mending works for installation of Split Air Conditioner as directed by EIC.
S&Fixing additional following item for complete installation,testing and commissioning of above AC machine :- (i)3 core 2.5 Sqmm PVC insulated FRLS grade copper cable (ii)Supply and Fixing of extra refrigerent pipe with foam insulation. (each meter refrigerent pipe will include cost of 1 mtr liquid pipe & 1mtr gas pipe of required dia.)as directed by EIC.
S&F of PVC Drain pipe incl. connections as directed by EIC.
OUTPUT IN BATTERY RUN (DC- AC) *Voltage variation static:± 1%*Voltage variation n(dynamic 0-100%;100-0%):± 1%*THDv on nominal power ( linear load):< 0.5 %*THDv on nominal power ( not linear load P.F= 0.7):< 1%*Frequency:50 Hz *Current Crest Factor:3: 1 according with IEC C62040 -3*Overload capability : @ unity PF :*10 min:115% load rate with no bypass intervention*60 sec:135% load tare with no bypass intervention*60 sec:135% load tare with no bypass intervention BATTERY *Type:SMF Minimum VAH required for 30 mins. back up:20160 *Charging Cycle:Intelligent with boost charge and advanced management*Battery Make:Quanta / Exide ENVIORNMENTAL SPECIFICATION *Noise level @1m:46 dBA*Working temperature range:from 0˚C to + 40 ˚C*Stock temperature range:from - 20˚C to + 50 ˚C ( Excluded batteries)*Humidity range:20-95% not condensing*Protection Degree:IP 21 MECHANICAL and Miscellaneous *Technology Rectifier/Booster/Inverter:IGBT*Communication Interface:2 serial Port RS 232, SNMP Enable*Input /Output connection:3P + N + PE Connectors on omega bar*Standards:EN 62040-3*Certificates:CE*Remote Monitoring Feature:Available (optional)
SITC of 5 KVA Single phase input & Single phase out put on line UPS systems. Topology, IGBT BASED DSP CONTROLED: Input Voltage: 230 VAC, 160 - 270 VAC Input Frequency: 50 Hz, 47 to 53 Hz nput PF: > 0.99 Output Voltage: 220 VAC +/- 1% Output Frequency: 50 Hz +/- 0.1% in Free running & +/- 4% in Sync Isolation Transformer: Provided Inbuilt (No external tranformer accepted ) Power Factor: 0.8 Lag to Unity Crest Factor: 3:1 Waveform: Sinusoidal THD: < 3% on linear load & < 5% on non-linear load Overload: 110% for 10 minutes, 125% for 1 minutes, 150% for 30 msec Transient Response : For 0 - 50% & 50% - 100% load change voltage remains within +/- 5% Ripple: < 2% Inverter Efficiency: > 93% Battery : 12 V, Mono Block batteries. Battery Back UP: 30 mim back up minimum VAH required 6240 VAH Battery Make: Exide, Amar Raja Quanta Powder coated open battery rack , Protections: Input & Output Over / Under Voltage, Single Phasing DC - High / Under Voltage, Battery Charging Over Current, Output Overload / Short Circuit / Over Temp., UPS auto ON on Mains recovery Audio Alarm, Mains Fail, Battery Low Pre-alarm, Inverter Trip Metering: Digital Seven segment - Voltage, Current & Frequency, Battery - Voltage & Current Indications: Mains - On / Fail / High / Low / Single Phasing DC - On / High, Battery - Low Pre-alarm / Low Trip Inverter - On / Trip / High / Low / Over Current (Make:- Numeric/APC/Emmerson/Switching AVO)
SITC of Addressable Manual Call Point (VDS / UL / FM / ULC approved) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor )
SITC of Analog Addressable Intelligent multisensor detector (VDS / UL / FM / ULC approved) with inbuilt optical smoke sensor, as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor )
SITC of Addressable Loop Powered Hooter (sound output of minimum 90 db) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor )
Supply & laying of 2C X 1.5 sq.mm CU. Control Cable(Make- Finolex/Polycab/Havells)
Supply & laying 20 mm PVC Conduit (Make- Precision-M/ PrestoPlast)
Note: 1) All the above rates should be quoted inclusive of all taxes & duties, District charges, Riverine charges and LWC as applicable, with cost of maintenance, servicing, supply & replacement of spares for 1 (one) years from the date of commissioning. 2) Total is rounded off to the nearest rupees.
M/S N. C. HORE
Abdul Electricals and Infrastructures Pvt Ltd
PARTHA SARKAR
JAYBEECO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .