Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 CrAccepted-AOC | ₹18.0 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹19.7 CrRejected-Finance | ₹19.7 Cr | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹19.7 CrRejected-Finance | ₹19.7 Cr | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹19.7 CrRejected-Finance | ₹19.7 Cr | L4 | Rejected-Finance Not being L1 |
| 5 | Rejected-Technical MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | - | - | Rejected-Technical See evaluation report |
Tender Value
₹17.2 Cr
EMD Value
₹11.8 L
Closing Date
4 Jun 2024, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVISION OF OTM ACCN AND MESSES AT NELLORE C/O AF STATION SURYALANKA (PHASE-II)
2024_MES_649961_2
801584/E8
Open Tender
Civil Works
540 days
Nellore
As per NIT
8 documents required · 8 mandatory
₹3,000
Yes
AGE (I) (AF) Suryalanka
₹11.8 L
Yes
27 Jun 2024
14 May 2024
11 Jun 2024
14 May 2024
4 Jun 2024
28 May 2024
Amount
BOQ Dated 21 May 2024
GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to XI are prepriced by MES under Ser No. 1 to 10. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “Internal Electric Supply" as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Site Clearance ” as listed in Schedule ‘A’ Part – IV.
Lumpsum price worked out by the contractor for “Road / Path / Culvert" as listed in Schedule ‘A’ Part V .
Lumpsum price worked out by the contractor for "Sewage Disposal" as listed in Schedule ‘A’ Part VI .
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part – VII.
Lumpsum price worked out by the contractor for “Security wall/Fencing” as listed in Schedule ‘A’ Part – VIII.
Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – IX.
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – X.
Lumpsum price worked out by the contractor for “Lightning Ptotection” as listed in Schedule ‘A’ Part – XI.
SCHEDULE 'A' PART - I (Building or Works) : Design and Construction of SM Barrack (Single Living Accn for 14 HAVs (SGTs) including cars/scooter parking, cook house and dining hall in G+1 framed construction with permanent specifications in RCC M-30 with AAC block masonry panel walls, ATT, PU based WPT, earthquake resistance as per latest IS etc complete all as specified and as shown on drawings.
Design and Construction of IFF Antena Tower (5mx5m of height 8m) in RCC M-30 framed construction with permanent specifications complete all as specified and as shown on drawings.
Design and Construction of SM Barrack (Single Living Accn for 26 ORs including cars/scooter parking,cook house and dining hall in G+1 framed construction with permanent specifications in RCC M-30 with AAC block masonry panel walls, ATT, PU based WPT, earthquake resistance as per latest IS etc complete all as specified and as shown on drawings.
Design and Construction of Radar Ramp with designed load 40-50 ton capacity and 8.0m height, 20.0mx8.0m staging including pillar spacing 4.5m under ramp and adjacent to ramp seperate 8.0x10.0m elevated structure of height 7.0m with permanent speciifcation in RCC M-30 complete all as shown on drawings and as specified.
Design and Construction of POL Store with permanent speciifcation in RCC M-30 complete all as shown on drawings and as specified.
Design and Construction of Armoury building with permanent speciifcation in RCC M-30 complete all as shown on drawings and as specified.
Design and Construction of Office and Technical Accommodation (HQ Admin Building) with permanent speciifcation in RCC M-30 complete all as shown on drawings and as specified.
Design and Construction of IRON Admin Block with permanent speciifcation in RCC M-30 complete all as shown on drawings and as specified.
Design and Construction of DSC guard post with rest room & watch tower with permanent speciifcation in RCC M-30 complete all as shown on drawings and as specified.
Note for items 11 to 19: (i) Refer Sch 'A' Notes completely before quoting these items. (ii) GRIHA certification is necessary only for buildings which fall under the classification of building as per GRIHA manual V 2019
Sch 'A' Part - XII : Fittings / Fixtures & Misc items. Internal Water Supply:- S & F 15mm bore angle cock cast copper alloy fancy type chromium plated for PP-R pipe/GI pipe complete all as directed.
S & F 15mm bore two way bib tap and health faucet cast copper alloy chromium plated fancy type, screwed down, screwed for PP-R /GI pipe complete all as directed.
Internal Electric Supply:- Supply and fixing LED light fitting study lamp 3 watt white with collection of adjustable LED bed side light, 220 Volt AC, not less than 120Lm/Watt with driver, holder, three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed.
Supply and fix MCCB DB VTPN 4 way vertical double door 415 volts AC 50Hz with MCCB as incomer TP, DP/SP MCBs as outgoing with tinned copper busbar, neutral link, earth link complete all as directed.
M & L for Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.3 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized earth wire 4mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 10 cm c/c both way for cover and MS frame etc., complete all as directed. NOTE: (i) The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Supply and fixing PVC conduit 20mm dia medium grade for telesocket and TV socket all as directed.
Supply and fixing Electric chimney single pleanum wall mounting type S.S exhaust hood with grease filters made out of SS304 grade 1mm thickness, 22 gauge GI duct with 25x25x3mm MS angle iron frames with necessary fittings, centrifugal blower 7.5HP/1440 RPM, 3 phase with anti vibrating pad and silencer air volume control damper, electrical wiring with starter for blower motor, fume exhaust installation, erection charges including blower stand angle frames, anchor threaded rods and fasteners complete all as directed.
Air Conditioning:- Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA.
Water Cooler:- Supply and fix refrigerator, electric driven (single phase), capacity more than 195 Litres .BEE 5 star rated complete all as directed.
All as per item No 29 above but not less than 360 Litres capacity
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA complete all as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA complete all as directed.
Flame Proof Fittings:- Supply and fixing Flame Proof Ceiling fan of 1200 mm sweep, Single phase, 250 Volts, complete with all accessories prewired and including connecting up with copper conductor cable of suitable size.
Supply and fixing Flame Proof Exhaust fan of 305 mm sweep with louver, Single Phase, 250 Volts complete with all accessories prewired and including connecting up with copper conductor cable of suitable size.
Supply and fixing Flame proof junction boxes with 15 Amps terminal block 4 way plain cover, minimum 20 mm dia entry holes and connecting up electrically the flame proof method complete all as directed.
Supply and fixing Flame proof flexible metalic hose conduit M20 / 3/4" conduit M x M or Fx M or F x F 500 mm complete all as directed.
Sewage Disposal :- S&F for 160mm outer dia DWCPE pipe of SN 8 laid and jointed complete with collars.
Provn of LLDPE septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete for 25 users
Provn of LLDPE septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete for 10 users
External Water Supply :- Construction of new valve chamber of size 750x750x750mm for 80mm dia gate valve including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6), plastring internal surface 15 mm tick in CM (1:4), PCC (1:3:6) type C1 coping, 50 x50x6 mm angle iron 6 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coats of synthetic enamel paint over a coat of zinc chrome primer all as shown on drawing and as specified
External Electric Supply :- S&F street light brackets made of 25 mm dia G.I. Pipe light grade in shape and angle as directed not exceeding 1.5 mtrs in length fixed to pole with suitable size of M.S. flat iron clamps, 2 Nos, M.S nut & bolt with cup washers, painting to MS material with anti corrisive paint complete all as directed.
S&F loop in-out junction box with non metalic FRP junction box suitable of size 350mm x 250mm with connector 4 way and including one MCB 6 A, 230V alongwith 2 Nos 'C' Clamps and back clamp made up of 20x3 flat iron and fixing on pole with necessary nuts bolts, washers, 2 Nos cable glands of size not exc 4 core 25 sqmm, Cable lugs as required complete all as directed.
BLANK
M&L for Earthing complete with earth galvanized steel plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead GI strip 32X6 by means of bolts, check nut and washers of GI or steel, GI pipe medium grade of 40 mm bore as protection pipe, GI strip of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia medium grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR Part-I complete all as directed.
M&L for Octagonal pole of 5 mtr height of bottom size 130 mm and top 70 mm dia with base plate size 220 x 220x12 mm, foundation bolts, Hot dip galvanized, single Arm suitable for fixing of All in one Solar Street light fitting of 15 Watt including necessary reducers, clamps, nuts, bolts and earth work, foundation with PCC 1:3:6 suitable for wind pressure of 100 Km/Hour as per OEM recommendation complete all as specified and as directed Note : Foundation drg recommended by OEM be submitted by the contractor along with pole/clamp drg for approval of Accepting officer before placing order (Street light 30 & Bldg Security light 53)
Supply and fixing of smart integrated all in one solar street light of 24 Watt, 5700 K with High efficiency Mono crystalline solar PV Module, Lithium Ferro Phosphate battery with in build BMS technology, High Efficacy LED, MPPT solar charge controller and Aluminium Extruded body & is specially programmed to automatically control the dimming and brightness of light, which increases the backup time complete all as specified and as directed
Supply and fix PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 3 core 1.5 sqmm 1100 Volt, conforming to IS 694, multistranded with Rigid Heavy duty PVC Conduit of 20 mm dia with bends from Junction box to connector of Street light fitting complete all as directed.
Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor, double door type made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 200 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following: (LT FPB-1 at Domestic area Substation)
(A) Main Incoming (i) Adjustable type MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 125 Amps, 415 volts, 50 Hz, rupturing capacity 16 KA - 01 No. (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iii) LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set (iv) 6 Step APFC Relay with ultra hevay duty capacitor of rating 05 kVAR-04 Nos along with necesaary harmonic filters, Duty Contactors, etc - 1 Set (B) Main Outgoing (i) Adjustable type MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 100 Amps, 415 volts, 50 Hz, rupturing capacity 16 KA - 02 No. (SNCO's Panel, Spare) (ii) MCB FP 6-32 Amps, 10 kA, C Curve -1 No. with Timer with 15 min step and battery backup (For Street Light) (iii) MCB DP 6-32 Amps, 10 kA, C Curve -2 No. (For watch tower and spare)
Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor, double door type made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 120 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following: (LT FPB-2 at Technical area Substation)
(A) Main Incoming (i) Adjustable type MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 63 Amps, 415 volts, 50 Hz, rupturing capacity 16 KA - 01 No. (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iii) LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set (iv) 6 Step APFC Relay with ultra hevay duty capacitor of rating, 05 kVAR-03 Nos along with necesaary harmonic filters, Duty Contactors, etc - 1 Set (B) Main Outgoing (i) Adjustable type MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 63 Amps, 415 volts, 50 Hz, rupturing capacity 16 KA - 02 No. (HQ Admn Bldg Panel, Spare) (ii) MCB FP 6-32 Amps, 10 kA, C Curve -1 No. (For Radar Ramp) (iii) MCB FP 6-32 Amps, 10 kA, C Curve -1 No. with Timer with 15 min step and battery backup (For Street Light)
Supply, installation, commissioning and testing of LT panel outdoor, double door type made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 150 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following: (SNCO's Panel)
(A) Main Incoming (i) Adjustable type MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 100 Amps, 415 volts, 50 Hz, rupturing capacity 16 KA - 01 No. (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iii) LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set (B) Main Outgoing (i) MCB FP 20-32 Amps, 10 kA, C Curve - 06 Nos (For SNCO's S/L, SNCO's Mess, IRON Bldg, DSC S/L, DSC Mess and Spare) (ii) MCB FP 6-32 Amps, 10 kA, C Curve -2 No. with Timer with 15 min step and battery backup (For Street Light -2)
Supply, installation, commissioning and testing of LT panel outdoor, double door type made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 120 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following: (HQ Panel)
(A) Main Incoming (i) Adjustable type MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 63 Amps, 415 volts, 50 Hz, rupturing capacity 16 KA - 01 No. (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iii) LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set (B) Main Outgoing (i) Adjustable Type MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 40 Amps, 415 volts, 50 Hz, rupturing capacity 16 KA - 02 No. (HQ Adm Bldg and Spare) (ii) MCB FP 20 Amps, 10 kA, C Curve - 01 Nos (For Armoury Bldg) (iii) MCB DP 10 Amps, 10 kA, C Curve - 03 Nos (For POL Room, Guard Rooma and spare)
Supply, installation, commissioning and testing of LT panel outdoor, double door type made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 60 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided, the space between ground to panel should be 60 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following: (Radar Panel)
(A) Main Incoming (i) MCB FP 32 Amps, C Curve, 10 kA - 01 No. (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iii) LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set (B) Main Outgoing (i) MCB FP 10-32 Amps, 10 kA, C Curve - 03 Nos (For Radar Ramp and IFF Antena, Spare) (ii) MCB DP 10 Amps, 10 kA, C Curve - 01 Nos (For Radar Ramp Lights)
LIGHTNING PROTECTION M&L for Earthing complete with copper earth plate plate electrode 600x600x3.15mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead copper strip 20x3 by means of bolts, check nut and washers of copper/brass, GI pipe medium grade of 40 mm bore as protection pipe, copper of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia light grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
grgprojects
K KUMAR RAJA PROJECTS P LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid