Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC JANAKI NIVAS BEHIND CHOVVA TEMPLE CHOVVA PO KANNUR KERALA 670006 | KANNUR | KANNUR | KERALA | 670006 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹14.0 L+₹3.2 L (29.8%)Rejected-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L2 | Rejected-AOC being L2 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
29 Dec 2022, 6:00 pmClosed
AGE I Cannanore
AGE I Cannanore HQ Hospital kannur PO 670017
Repairs/maintenance to Transformers, connected works and Repairs to ceiling fan, geysers, certain misc works at Mily Station Kannur under AGE (I) CANNANORE.
2022_MES_562577_1
8237
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
cannanore
Class E Category b( i )(ii)
8 documents required · 8 mandatory
₹500
Yes
AGE I Cannanore
₹19,000
Yes
20 Feb 2023
11 Nov 2022
4 Jan 2023
12 Nov 2022
29 Dec 2022
25 Nov 2022
12 Nov 2022 - 18 Nov 2022
Amount
Taking down carefully existing 11KV/433 V distribution transformer of capacity upto and including 100 KVA by disconnecting HT overhead connection/underground cables and earth strips etc. from any substation / locations using crane of suitable capacity or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Transpoting the tranformer to subsation after repairs, placing at given position, connection of HT overhead line/underground cables and earth strips etc. testing and commissioning complete all as specified and directed by Engr-in-charge.
All as per item No 1 here in before but transformer of capacity above 100KVA to 250KVA all as specified and directed by Engr-in-charge. Note for item 1&2 : All T&P required for loading, unloading and transportation including necessary items like bolts, nuts etc shall be arranged by the contractor and rates for the same deem to be included in the quoted rates .
M&L for opening the transformer cover along with the conservator by removing the nuts, bolts, after removing the internal H.T & L.T connections by taking them out by removing studs, bushings, taking out the core-winding assembly out of the tank, removing out burnt HV and LV windings from the core assembly, cleaning of core assembly with CTC including necessary repairs for the unserviceable transformers having ratio 11 / 0.433 KV, draining & decanting of burnt transformer oil and cleaning of sludge deposited in the tank with CTC for the transformers. Rewinding of HV and LV coils with suitable size super enamelled copper wire/ strip (As Existing) having suitable class insulation material. Heating of core winding assembly in hot chamber for 48 hours and removing all the moisture present in it, removal of leakage of tank if any by welding, refilling transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal H.T & L.T connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket along with conservator, testing the transformer in the workshop duly filled with oil, all as directed by Engineer-in-Charge for 100KVA capacity transformer.
All as per item No 3 here in before but transformer of capacity above 100KVA to 250KVA all as specified and directed by Engr-in-charge. Note for item 3&4 : Unserviceable items required for repairs of transformer shall be measured and paid separately under relevant item of this schedule. Transformer oil with die electric strength not less than 45 KV either new or filtered shall be filled and shall be measured and paid seperately under respective item.
S&F in replacement of LT bushings 433V of suitable size for outdoor/ indoor type transformer of the capacity 100KVA all as specified and directed.
S&F in replacement of LT bushings 433V of suitable size for outdoor/ indoor type transformer of the capacity above 100KVA to 250KVA all as specified and directed.
S&F in replacement of HT bushings 433V of suitable size for outdoor/ indoor type transformer of the capacity 100KVA all as specified and directed.
S&F in replacement of HT bushings 433V of suitable size for outdoor/ indoor type transformer of the capacity above 100KVA to 250KVA all as specified and directed.
Supply & fixing in replacement of brass stud (for LT 433V side) of suitable size complete with one check nut, two nuts, washers and rubber seal, all as per sample for outdoor/indoor type transformer of the capacity upto 250 KVA all as specified and directed.
Supply & fixing in replacement of brass stud (for HT 11KV side) of suitable size complete with one check nut, two nuts, washers and rubber seal, all as per sample for outdoor/indoor type transformer of the capacity 100 KVA all as specified and directed.
Supply & fixing in replacement of brass stud (for HT 11KV side) of suitable size complete with one check nut, two nuts, washers and rubber seal, all as per sample for outdoor/indoor type transformer of the capacity above 100KVA to 250KVA all as specified and directed.
M&L for dehydration including filteration of transformer oil by dehydration and filteration plant including testing before and after dehydration and filteration complete of transformer capacity upto 250KVA all as specified and directed. Note:- (i) The dielectric strength to be achieved 40 KV at 2.5 mm gap after completion of dehydration and filteration. (ii) Dehydration of transformer oil in the transformer carried out on the site by dehydration machine and the amount quoted is deemed to be inclusive.
Supply and filling of new transformer power oil of BDV not less than 50 KV for topping up of reduced level of Distribution transformer complete including removing of old unserviceable transformer oil all as specified and directed. Make : power oil/castrol/pure lubes.
M&L for preparation of old painted surfaces and cooling coils/ fins of transformers upto 250KVA capacities by removing oil marks using chemical or hot blow lamp, Spray painting to prepared surfaces using synthetic enamel paint of superior quality of colour as approved by AGE (I) as per standard engineering practice with two coats, writing SM No, MES No, Make and capacity with white paint having height of each letter not less than 2.5cm and width not less than 1cm all as required and directed by Engr-in-Charge.
Supply and filling up in replacement silica gel superior quality to transformer breather assy all as required and diercted.
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard / dense soil all as specified and directed.
Returning and filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soil obtained from excavation all as directed
Removing excavated materials (soil) to a distance n exceeding 50m and depositing where directed at a level 1.5m above starting point all as specified and directed.
Supply and spreading in natuaral riddled soil as earth cushioning to cable by using IS sieve to separate the composite particle/roots etc and refilling in trenches and compacted in layers to form a solid bed covering to cable all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat unreinforced of size 300mm x 180mm x 40mm for protecton of cable abutting each laid dry flat width equal to the lenth of cable cover etc complete all as spd and directed.
M&L for GI tubing, 100mm bore light grade, galvanized, with all fittings required such as bends, Tees, elbows, sockets, fixing clamps etc for protection of cable/GI strip fixing on ploe, wall etc including removing old unserviceable pipe any size all as directed.
M&L for GI tubing, 150mm bore light grade, galvanized, with all fittings required such as bends, Tees, elbows, sockets, fixing clamps etc for protection of cable/GI strip fixing on ploe, wall etc including removing old unserviceable pipe any size all as directed.
Material and labour for detection of any type of fault in HT underground cable of any size and core laid in trenches with the help of HT Meggar, Seggregation of faulty span by meggering and making serviceable by repair or replacement of cable and testing complete all as directed. Note : (i) Earth work and excavation will be measured and paid seperately. (ii) Lenght of cable used for replacement will be measured and paid saperately. (iii) Contractor will engage an electrician and helper to attendent daily from the date of commencement of work till completion of the work in the office of Engr-in-charge to attend the fault related complaints as directed by Engr-in-charge. The cost of labour shall deemed to be included in the item.
Material and labour for detection of any type of fault on HT 2/4 pole structure and reapir/ replacement of blown out HT fuses and restore the HT supply of feeder all as directed. Note : (i) Contractor will engage an electrician and helper to attendent daily from the date of commencement of work till completion of the work in the office of Engr-in-charge to attend the fault related complaints as directed by Engr-in-charge. The cost of labour shall deemed to be included in the iquoted rate. (ii) Cost of material reqd for repair will be included in quoted rate. (iii) Proper shut down shall be taken from MES auth before any HT repair wk. (iv) All safety measure will be the resposibility of contractor.
Material and labour for detection of any type of fault in HT underground cable laid in trenches with the help of Cable fault locator machine brought by the cable fault detection agencies, Span of faulty cable will be trace out by the agencies by meggering HT cable. Seggregation of faulty span by meggering and making serviceable by repair or replacement of cable, testing and complete all as directed. Note : (i) Earth work and excavation will be measured and paid seperately. (ii) Lenght of cable used for replacement will be measured and paid saperately. (iii) Contractor will engage an electrician and helper to attendent daily from the date of commencement of work till completion of the work in the office of Engr-in-charge to attend the fault related complaints as directed by Engr-in-charge. The cost of labour shall deemed to be included in the item.
Taking out old unserviceable HT UG cable, Supply and lay including fixing and connecting electrically XLPE insulated HT underground cable 3core 120sqmm, armoured heavy duty electric cable with aluminum conductor multi-stranded 11KV grade, laid in trench, fixed on wall/pole drawn through pipe etc including provision of lugs & testing of following sizes complete all as specified and directed.
M&L for Structural steel work in replacement of existing unserviceable Cross arms bracing, supports, clamps and back plates fabricated from steel sections including nuts,bolts ,washers,welding ,bending cold or hot drilling holes for bolts in any shape or size as indicated or directed inclusive one coat of primercoat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
S&F in repairs cable jointing kit for 11KV grade cable for Outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm jointing and testing all as specified and directed. .
S&F in repairs cable jointing kit for 11KV grade cable for Outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm jointing and testing all as specified and directed.
Material and labour in replacement of Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm 3 core with working voltage 11000 volts complete all as specified and direced by Engr - in- Charge.
Material and labour in replacement of Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm 3 core with working voltage 11000 volts complete all as specified and direced by Engr - in- Charge.
S & F in replacement of Lightning arresters expulsion type (Set of Three) complete with all fittings, Distribution class, discharge capacity 65 kilo amp complete all as all as specified and direced by Engr - in- Charge.
S & F in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour including fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-in-charge.
S & F in replacement of Anti-climbing device; spikes type fabricated out of M.S. bars (round,square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed by Engr-in-charge.
M & L for Painting of HT concrete 2/4 pole of complete length, after preparing pole surfaces by scraping / brushing and by applying one coat of white cement based paint, applying a coat of white synthetic enamel painting to pole upto 1.5 mtr from ground level, painted by alternate layer of black and Yellow enamel paint (30 cms apart) and applying two coat of aluminium painting on Cross arm and bracing, nut, bolts and washers etc after prep of surfaces all as directed by Engr in charge. Note - one 2/4 pole structure measured as one job inclusive of HT poles and cross arms complete.
M & L for dismantling of old air break gang operated switches vertical mounted including insulators and operating mechanism complete all as sopecified and directed by Engr-in-charge.
M & L in replaceement switch Air break gang operated triple pole (horimounted on porcelain insulators 15 Nos 11 KV 400 Amps DO fuse set with AB switch porcelain and steel frame with operating mechanism with 20 mm dia GI pipe (Medium grade) operate from ground level complete all as specified and directed by Engr-in-Charge.
M&L in replacement for Stay assembly with loop type insulator, vitreous porcelain, large size, 90 x 140mm, clearance of hole 25.5 mm complete with accessories as shown in Electrical Plate No 1 of SSR Part-I consisting of stay rod 20 mm dia, stay plate 300 x 300 x 6 mm thick and GI stay strand 7/4mm including necessary fixing clamps, nuts, bolts, etc; complete all as specified and directed.
M&L in replacement of off load tap changer suitable for existing distribution transformer of any make ad capacity upto 250 KVA all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using galvanised iron strip 32x6mm as earthing lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt).
Taking down carefully geyser 25 to 50 ltrs capacity from wall after unscrewing nuts/bolts etc and refixing in same position after repair and replacement of unserviceable spare-parts including dismantlling, assembly of water storage tank and testing Complete all as specified and directed by Engineer-In-Charge. NOTE :- Supply and Replacement of Spare componants shall be measured and paid separtely under the relevant items.
S&F Thermostat (ISI Marked) suitable for geysers 25 -50 Ltrs capacity, AC 230 volt, adjustable range from 0-90 degree Celsius. Complete including dismantling of unserviceable thermostat all as specified and directed by Engineer-In-Charge.
S&F in replacement of old unserviceable fusible plug (ISI Marked) suitable for 25 to 50 Ltrs capacity Geysers Complete all as specified and directed by Engineer-In-Charge .
S&F in replacement of old unserviceable Syphon assembly of 06 holes/ 09 holes (ISI Marked) made out of brass suitable for 50 ltr capacity geyser including necessary studs, screws and rubber gasket/washers etc Complete all as specified and directed.
S&F in replacement of old unserviceable Syphon assembly of 06 holes / 09 holes (ISI Marked) made out of brass suitable for 25/35 ltr capacity geyser including necessary studs, screws and rubber gasket/washers Complete all as specified and directed.
S&F in replacement of old unserviceable valve (ISI Marked) suitable for 25 to 50 Ltrs capacity geysers Complete all as specified and directed.
S&F in replacement of old unserviceable heating element titanium coated of rating 1.5 Kw suitable for water heater storage type any make and type as required at site including rubber washers (ISI marked) Complete all as specified and directed. Make : Bajaj/ Hot Zone/Theeta/Daspas/Airex
S&F in replacement of old unserviceable heating element titanium coated of rating 2.0 Kw suitable for water heater storage type any make and type as required at site including rubber washers (ISI marked) Complete all as specified and directed. Make : Bajaj/ Hot Zone/Theeta/Daspas/Airex
S&F in replacement old unserviceable 1.8 mm thick (18 gauge) stainless steel water tank with 0.7 Mpa bar pressure, suitable for geyser 25 ltr capacity complete with rubber gasket, Complete all as specified and directed.
All as per item No 49 here in before but suitable for geyser 50 ltr capacity complete with rubber gasket, Complete all as specified and directed. Notes for item No 49 &50 :- (i) The tank shall be tested at site and shall be able to withstand requisite pressure, necessary arragengments for the testing shall be made arranged by the contractor. (ii) Tank with stud type and round element shall only be provided.
S&F in replacement Geyser connection pipes for hot and cold water supply made of stainless steel wire braided connector with chrome finish heavy duty nuts of 15mm size with suitable lengh including taking down of old unserviceable pipes complete all as specified and directed.
M & L for Replacement of old unserviceable thermal insulation material non hygroscopic, fire resistant, fiber glass wool for 25-50 ltrs capacity geyser complete all as specified and directed by Engr-in-Charge
M & L for preparing the old painted steel surfaces by rubbing/scratching the old painting of 25 ltrs capacity geyser and painting with two coats of synthetic enamel paint, white with spray gun including writing MES Nos with black paint (of required size and shape) complete all as specified and directed by Engineer-in-Charge.
All as per item No 53 here in before but for geyser 50 ltr capacity complete all as specified and directed.
S&F in replacement Sheet metal enclosure single pole and neutral with a two pin, earth plug and socket with one double pole MCB of 20 Amp ,240 Volt Complete all as specified and as directed by the Engineer-in-charge.
S&F in replacement for 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed.
S&F in replacement for MCB SPN 40 to 63 Amps breaking capacity 10 KA 'B' series 240 volts 50 Hz complete all as specified and directed.
S&F in replacement Indicator lamp (green & red ) with Neon lamp (ISI Marked) indicating automatic working of geyser round/square type suitable for geyser capacity 25/50 ltr AC 230 volt Complete all as specified and as directed by the Engineer-in-charge
S&F in replacement of anchor bolt of size 12mm x 100mm long with washer including drilling holes for fixing anchor bolt and making good to the disturbed surface matching with specification complete all as specified and as directed by the Engineer-in-charge.
M & L for Descaling of geyser of capacity 25litre /50litre after unscrewing nuts/bolts and taking down from wall and refixing in position after repair including strip opening the assembly, de-scalling the syphon assembly, steel tank and incoming and outgoing water connection complete and testing all as specified and as directed by the Engineer-in-charge.
M & L PVC cable insulated and overall sheathed copper conductor cord flexible wire , multistranded 1100 volt grade of size 2.5 sqmm, 3 core ( ISI Marked ) complete all as specified and as directed by the Engineer-in-charge.
M&L for taking out old unserviceable ceiling fans from site and removal of burnt winding wire by cutting, clening slots and re-Winding of AC ceiling fan motor 1200/1400 mm of any make with super enameled copper winding wire of existing gauge varnishing with E class insulation varnish, threading, including neceassry laith work and refixing in same location, connnecting up electrically with appropriate size copper conductor cable upto connector block Complete all as specified and directed by Engineer-In-Charge . Notes:- (i) Doctor brand or equivalents ISI brand varnish shall be used. (ii) Motor winding shall be wound with machine only. (iii) BIC/HTP or DEVIDYAL. make super enameled copper winding wire shall only be used. (iv) Weight of copper winding wire per fan shall be min 350 gm.
All as per Srl item No 62 here-in-above but weight of copper winding wire shall be above 500 gram per fan of size 1400 mm sweep complete all as specified and directed by Engineer-In-Charge .
S&F in replacement of old unserviceable gun metal bush of ceiling fan including neceassry laith, Grinding and welding work Complete all as specified and directed by Engineer-In-Charge .
S&F replacement of old unserviceable capacitor AC 230 volts 2.5 mfd (ISI marked) Complete all as specified and directed by Engineer-In-Charge .
S&F in replacement of old unserviceable capacitor AC 230 volts 3.15 mfd (ISI marked) Complete all as specified and directed by Engineer-In-Charge .
S&F in replacement of old unserviceable capacitor AC 230 volts 4.00 mfd (ISI marked) Complete all as specified and directed by Engineer-In-Charge .
S&F in replacement of old unserviceable ball bearing of size 6200 to 6204 including neceassry laith , Grinding and welding work Complete all as specified and directed by Engineer-In-Charge . Make NBC/SKF
S&F in replacement of old unserviceable shackle assembly kit (Rubber real -01, MS split clamp two Nos, nuts and bolts washers- 2 Nos & split pin -02 Nos) suitable for ceiling fan of 1200/1400mm sweep Complete all as specified and directed by Engineer-In-Charge
S&F in repalcement of old unserviceable down rod of ceiling fan of 20 mm bore "medium grade" with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) in white/brown colour (fully furnished) Complete all as specified and directed by Engineer-In-Charge.
Material and Labour for Servicing of ceiling fans of 1200/1400mm sweep any type any make including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins (02 Nos), cutter pins(02 Nos), and refixing to the same location after servicing Complete all as specified and directed by Engineer-In-Charge.
Supply and Fixing in replacement of PVC cable insulated and overall sheathed with flexible copper conductor of size 0.5 sqmm, 3 core cut to size of approx 0.30 metre from fan to ceiling rose Complete all as specified and directed by Engineer-In-Charge.
M&L for taking down old unsv exhaust fan from site and removal of burnt winding by cutting, clening slots and re-winding of exhaust fan/ Table fan/cabin fan of motor capacity 250-380mm sweep any make with super enameled copper winding wire of exisiting gauge, including cuting and getting out old burnt winding, sleev work , varnish with E class insulation varnish threading, including neceassry laith , granding and welding work complete and connections with appropriate size copper conductor cable upto connector block Complete all as specified and directed by Engineer-In-Charge. (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used)(ii) Motor shall be wound with machine only. (iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used. (iv) Copper winding shall be of weight upto 300 gms.
All as per Srl item No 73 here-in-above but for exhaust fan/ Table fan/cabin fan of motor capacity 400mm-450mm sweep Complete all as specified and directed by Engineer-In-Charge.
Material and Labour for removing old paint by scraping down with sand paper including washing and filling cavaties with filler and applying two coats of painting with synthetic enamel paint over a coat of red oxide primer by spray gun using spray gun method painting to ceiling fan of 1200mm sweep at site including 03 Nos blades, motor (both sides) down rod, writing MES No/ Srl No on the ceiling fans Complete all as specified and directed by Engineer-In-Charge.
All as per Srl item No 75 here-in-above but for ceiling fan of 1400mm sweep Complete all as specified and directed by Engineer-In-Charge.
All as per Srl item No 75 here-in-above but for Exhaust fan of 400mm sweep Complete all as specified and directed by Engineer-In-Charge.
All as per Srl item No 75 here-in-above but for Exhaust fan of 300mm sweep Complete all as specified and directed by Engineer-In-Charge.
Sreekrupa Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .