Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Rate | |
| 2 | L2₹32.4 L+₹28,259 (0.88%)Rejected-Finance | L2 | Rejected-Finance High Rate |
Tender Value
₹32.5 L
EMD Value
₹65,100
Closing Date
19 Aug 2022, 4:00 pmClosed
DIGP, GC, CRPF, Pinjore (Haryana)
DIGP, GC, CRPF, Pinjore (Haryana)
AMC of 04 Nos Electric sub station, water plant (submersible pump) and 03 Nos DG sets at GC CRPF Pinjore (Haryana)
2022_CRPF_706738_1
L-VII-1/2022-23-GCP-Bldg(AMC)
Open Tender
AMC/ Maintenance Contracts
Turn-key
365 days
GC, CRPF, Pinjore (Haryana)
As Per Tender Documents
2 documents required · 2 mandatory
₹0
₹65,100
Yes
3 Oct 2022
13 Aug 2022
20 Aug 2022
13 Aug 2022
19 Aug 2022
13 Aug 2022
13 Aug 2022 - 19 Aug 2022
Amount
Servicing ,cleaning ,testing and Commissioning of 400 Amp 11 KV HT OCB including oiling all mechanical parts clearing all electrical contact with chemical, cleaning of bus bar nut bolts and checking all electrical connections of all accessories link armature , voltmeter ,KWH meter,CTFT etc, carrying out insulation test complete with testing of tripling mechanism etc . as required.
Calibration of IDMT relay having over current & 1 earth fault relay with secondary injuction kit after servicing cleaning etc. including chemically all electric wiring upto tripping circuit complete as required.
Servicing cleaning and resting of LT ACBs and bush couple 1000 AMP including cleaning of terminal with chemical all mechanical moving parts conducting insulation test of LT panel setting at static release etc .as required.
Servicing and testing of 400 to 1000 KVAoil type transformer i/c cleaning of all parts with CRC/CTC decarbonising of enclosure , tighening of incoming and outgoing connections and repairing of enclosure doors for proper locking etc as required.
Carrying out insulation test with HT mugger of 500/630 KV ,11 KV , transformer HT cable bushtrunking upto HT panels, LT panel respectively including testing and dielectric strength of transformer all complete as required.
Dehydration, filtration of transformer oil with portable dehydration machine to achive dielectric strength above 50 KV including testing carrying out test of dielectric strength oil before and after dhydration complete as required.
Supplying and adding of ISI marked dehydrated transformer oil to transformer.HT OCB , FT etc. as required.
Supplying & replacement of silica gel suitable for following capicity of transformer - 500/630 KVA.
Cleaning of outer surface of exisiting 500 KVA transformer in installed position i/c painting of the outer surface of the said transformer with approved quality and colour enamel paint complete as required.
Main LT panel servicing & replacement of damage part thimble , bush bar , nut bolt, separtor & cleaning with CTC chemical complete job at site.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Providing and Replacement of defective parts of control panels and starters of desired specification set as MCB/MCCB/contactors/relay/voltmeter/ammeter etc as required.
Ammeter (Digital)
Voltmeter (Digital)
MCB single pole
MCCB 63 Amp (3 pole) L & T
MCCB 250 Amp (4 pole ) L & T
MCCB 125 Amp (4 pole ) L & T
Timer
Indicator
Terminals/ Thimble / Lugs etc.
On/Off Button (Push Button)
Earthing
Capacitors
Single phase preventor
Relay (DLR) 28 to 42 amp
Contactor ML2
Contactor ML1.15
MCB DP
MCB 4 pole insulator
MCB TP
Repair/Rewinding and Servicing work of 500 KVA Faulty Transfarmer (Electric sub station)
Lfting and lowering of pump including replacement of unserviceable nut ,bolt, washers, gaskets etc.
Submersible 30 HP
Submersible pump machi 75 HP
Contrifugal motor 75 HP
Induction motor 40 HP
Submersible 15 HP
Rewinding/Repairing with all necessary spares of manufacture specifications including installation, commissioning , testing & transportation of submersible motors, sludge motors & centrifugal pumps sets etc at respective location.
Submersible 30 HP
Submersible pump machi 75 HP
Contrifugal motor 75 HP
Induction motor 40 HP
Submersible 15 HP
Supplying pig lead at site of work.
Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead
150 mm diameter pipe
200 mm diameter pipe
Fixing of mechanical colar joint of old C I/D I pipe line including cutting and all fitting at site, as directed by Engineer-in charge.
150 mm diameter pipe
200 mm diameter pipe
fixing of C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc.
150 mm diameter pipe
200 mm diameter pipe
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge
All kinds of soil
Providing services of Skilled electrician/Operator for Opereation & Routine maintenance work of pumps , motors,water supply and pipe line at bhagwanpur and Gc campus working hours/Timing shall be as per direction of engineer-in-charge or his representative etc,as required.
Servicing, Testing, Commissioning of 125 KVA DG Set including replacement of followings spares & mobil oil, filter etc as required.
Servicing, Testing, Commissioning of 250 KVA DG Set including replacement of followings spares & mobil oil, filter etc as required.
Servicing, Testing, Commissioning of 320 KVA DG Set including replacement of followings spares & mobil oil, filter etc as required.
Providing services of Skilled electrician/Operator for Operator i/c cleaning of electrical installation, DG sets , electric panel, feeder pillars and LT & HT cable at Gc campus working hours/Timing shall be as per direction of engineer-in-charge or his representative etc,as required.
B S ELECTRICAL
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .