ASSISTANT EXECUTIVE ENGINEER
O/o Assistant Executive Engineer, PWD Electrical Subdivision, Civil Station, Alappuzha-688001
GENERAL-AMC Split A/C-Annual Maintenance Contract of Split Air Conditioning units for the period one year - 2026-2027 Part 3- at Govt TD MCH ,Vandanam, Alappuzha- Electrical AC Work
2026_PWD_838778_1
PWD/BLDG/TR/1413/2026_6_1_1
Open Tender
Electrical Works
Percentage
365 days
Vandanam
Please refer tender documents
11 documents required · 11 mandatory
₹555
₹5,371
16 May 2026
21 Feb 2026
5 Mar 2026
21 Feb 2026
3 Mar 2026
21 Feb 2026
AMC of split ACs
OD284484/2025-2026:Charges for dismantling the existing defective compressor from the existing AC unit, supply installation testing and commissioning of new compressor and giving all mechanical, electrical connections for the following AC units. 3 TR A/c unit-
OD284495/2025-2026:Charges for filling sufficient quantity of R134a / 410a/R32/R22 gas for existing air conditioner unit including leak testing rectifying the defects leak arresting etc as required-
OD284488/2025-2026:Supply and installation of out door unit stand for single phase wall mounting split AC unit as required-
OD284489/2025-2026:Supply and Fixing of 5 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V (V-Guard or its equivalent)
OD284496/2025-2026:Supply and Fixing of 4 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V (V Guard or its equivalent
OD284490/2025-2026:Supplt and providing Remote control unit with battery suitable for single phase 1TR/1.5TR/2TR wallmounting split type Air conditioner units as required-
OD284491/2025-2026:Supply and installation of Oscillation motor suitable for 1/1.5/2TR AC Indoor unit as required-
OD284487/2025-2026:Supply and fixing of 25mm (10kg/sq.cm) PVC drain pipe along with all required accessories in surface/ recess including cutting the wall and making good the damages etc. as required-
OD284501/2025-2026:Supply and installation of Copper condensing coil suitable for 1/1.5/2TR Split type AC unit as required-
OD284504/2025-2026:Supply and installation of Indoor blower motor suitable for 1/1.5/2TR Split type AC unit as required-
OD284494/2025-2026:Supply and renewing 9/12 A 3 Pole , AC 3 Power Contactors( L&T make MNX 12/equivalent) for 3ph AC Units in place of the existing faulty ones and giving connections etc as required-
OD284493/2025-2026:Supply and renewing 22 A 2 Pole , AC 3 Power Contactors( L&T make MNX 22-2p/equivalent) for 1ph AC Units in place of the existing faulty ones and giving connections etc as required-
OD284497/2025-2026:Supply and renewing Single phase preventer relay( L&T make9032-Sz5/equivalent) for AC Units in place of the existing faulty ones and giving connections etc as required-
OD284483/2025-2026:Supply and renewing capacitor for AC fan motor including giving connections-
OD284500/2025-2026:Supply and fixing outdoor fan motor blade suitable for 1.5/2/3TR Split type AC unit as required-
OD284486/2025-2026:Supply and renewing Starting Capacitor 80-100 MFD for 1 /1.5/2 TR AC unit in place of the existing faulty ones and giving connections etc as required-
OD284502/2025-2026:Supply and renewing Running Capacitor for AC unit - 1/1.5/2/ TR in place of the existing faulty ones and giving connections etc as required-
OD284503/2025-2026:Supply and renewing Outdoor Fan Motor for Split AC unit-1/1.5/2TR in place of the existing faulty ones and giving connections etc as required-
OD284492/2025-2026:Supply and renewing PCB unit for Split AC unit-1/1.5/2TR in place of the existing faulty ones and giving connections etc as required-
OD284505/2025-2026:Charges for checking and repairing the existing defective control board of the 1/1.5/2 TR AC unit and re connecting the unit and make the unit in good working condition as required-
OD316073/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge
OD316075/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rebberized foam sleeve 10mm thick, brazing leak, testing etc.. 3/8 inch(9.52 mm) and 5/8 inch(15.8 mm) 22 guage.
OD284506/2025-2026:Labour charges for arresting refrigerant leakage in copper pipeline of A/C units by brazing using lead. (indoor and outdoor unit) installed at different location as required
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1413122.xls
BOQ • 0.28 MB
viewsbd1413.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .