Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | ₹6.6 L Quoted ₹6.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹7.9 LRejected-AOC | ₹7.9 L | L2 | Rejected-AOC L2 |
| 3 | L3₹7.9 LRejected-AOC | ₹7.9 L | L3 | Rejected-AOC L3 |
| 4 | L4₹8.5 LRejected-AOC 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | ₹8.5 L | L4 | Rejected-AOC L4 |
| 5 | L5₹8.8 LRejected-AOC UPPER SARTHI VIHAR AJABPUR DANDA PO NEHRU GRAM POLICE STATION DALANWALA HARIDWAR ROAD DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹8.8 L | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | Jain Traders L4 | A ONE BUILDERS AND ENGINEERS L6 | PARADISE INFRA POWER COMPANY L2 | FATEH ENTERPRISES L3 | AMIT ENTERPRISES L1 | Garhwal Enterprises L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling and taking down u/s TPN/ SPN DBS including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified & as directed. | 119 | RM | 19 ₹2,261 | 40 ₹4,760 | 50 ₹5,950 | 30 ₹3,570 | 66 ₹7,854 | 5 ₹595 |
| 2.00 | Supply and fixing sheet metal enclsoure double door type for MCCB DB TPN 4 way Vertical including MCCB 4 pole, adjustable thermal & fixed magnetic type 63 Amp, 26 KA, 4 pole MCCB complete all as specified & as directed. | 8 | Each | 11,449 ₹91,592 | 7,003 ₹56,024 | 11,500 ₹92,000 | 9,000 ₹72,000 | 4,666 ₹37,328 | 13,000 ₹1.0 L |
| 3.00 | S&F in repair MCB DB TPN 4 way 415 V rated copper busbar in sheet steel enclosure double door type, complete all as specified and as directed. | 10 | Each | 2,749 ₹27,490 | 3,000 ₹30,000 | 2,200 ₹22,000 | 2,300 ₹23,000 | 1,999 ₹19,990 | 2,150 ₹21,500 |
| 4.00 | S&F MCB DB SPN 12 way 240 volts rated copper busbar in sheet steel enclosure double door type complete all as specified and as directed. | 38 | Each | 1,349 ₹51,262 | 1,701 ₹64,638 | 1,450 ₹55,100 | 1,270 ₹48,260 | 1,222 ₹46,436 | 1,350 ₹51,300 |
| 5.00 | S&F MCB DB SPN 8 way 240 volts rated copper busbar in sheet steel enclosure double door type complete all as specified and as directed. | 38 | Each | 1,049 ₹39,862 | 1,500 ₹57,000 | 1,250 ₹47,500 | 1,080 ₹41,040 | 1,111 ₹42,218 | 1,000 ₹38,000 |
| 6.00 | S&F MCB DB SPN 4 way 240 volts rated copper busbar in sheet steel enclosure double door type complete all as specified and as directed. | 25 | Each | 849 ₹21,225 | 901 ₹22,525 | 1,150 ₹28,750 | 700 ₹17,500 | 999 ₹24,975 | 850 ₹21,250 |
| 7.00 | Supply & fixing MCB , SP, AC, 240 volts of 05 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed. | 690 | Each | 89 ₹61,410 | 136 ₹93,840 | 125 ₹86,250 | 106 ₹73,140 | 119 ₹82,110 | 100 ₹69,000 |
| 8.00 | Supply & fixing MCB, SPN, AC, 240 volts of 40 to 63 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed. | 180 | Each | 289 ₹52,020 | 400 ₹72,000 | 275 ₹49,500 | 349 ₹62,820 | 155 ₹27,900 | 800 ₹1.4 L |
| 9.00 | Supply & fixing MCB, TPN, AC, 415 volts of 40-100 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed. | 10 | Each | 749 ₹7,490 | 776 ₹7,760 | 1,700 ₹17,000 | 1,056 ₹10,560 | 222 ₹2,220 | 1,250 ₹12,500 |
| 10.00 | Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified & as directed. | 1,815 | RM | 9 ₹16,335 | 2 ₹3,630 | 5 ₹9,075 | 1 ₹1,815 | 4 ₹7,260 | 5 ₹9,075 |
Updated dates
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
9 Apr 2026, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR AND MAINT OF VTPNs DBs, TPN DBs, SPN DBs, SUB MAIN, EARTHING AND CONNECTED WORKS AT VARIOUS LOCATIONS OF GRRC UNDER AGE (I) LANSDOWNE.
2026_MES_756070_1
9186/E8
Open Tender
Electrical and Maintenance Works
180 days
AGE I Lansdowne
All as per NIT and Tender Documents
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹20,000
Yes
8 May 2026
12 Mar 2026
10 Apr 2026
13 Mar 2026
9 Apr 2026
27 Mar 2026
Dismantling and taking down u/s TPN/ SPN DBS including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified & as directed.
Supply and fixing sheet metal enclsoure double door type for MCCB DB TPN 4 way Vertical including MCCB 4 pole, adjustable thermal & fixed magnetic type 63 Amp, 26 KA, 4 pole MCCB complete all as specified & as directed.
S&F in repair MCB DB TPN 4 way 415 V rated copper busbar in sheet steel enclosure double door type, complete all as specified and as directed.
S&F MCB DB SPN 12 way 240 volts rated copper busbar in sheet steel enclosure double door type complete all as specified and as directed.
S&F MCB DB SPN 8 way 240 volts rated copper busbar in sheet steel enclosure double door type complete all as specified and as directed.
S&F MCB DB SPN 4 way 240 volts rated copper busbar in sheet steel enclosure double door type complete all as specified and as directed.
Supply & fixing MCB , SP, AC, 240 volts of 05 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply & fixing MCB, SPN, AC, 240 volts of 40 to 63 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply & fixing MCB, TPN, AC, 415 volts of 40-100 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified & as directed.
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 25mm dia or more medium grade surface/concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed. Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in existing conduit surface/ concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly complete all as specified and as directed. Note: Two runs of phase, netural wire and one run of earth wire will be measured as one RM or one length.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia medium grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
BOQ_846892.xls
BOQ • 0.33 MB
Tenderdocuments.pdf
Tender Documents • 0.64 MB
Download all tender documents and submit your bid