Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹24.8 L+₹34,320 (1.40%)Rejected-AOC 129 A NICHLI CHOWKI DEVI NAGAR SECTOR 32 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L2 | Rejected-AOC BEING L2 | |
| 3 | L3₹26.8 L+₹2.3 L (9.38%)Rejected-AOC | L3 | Rejected-AOC BEING L3 |
Tender Value
₹39.8 L
EMD Value
₹79,620
Closing Date
25 Nov 2024, 6:00 pmClosed
GE(AF) BAREILLY
GE(AF) BAREILLY UP-243002
SPECIAL REPAIR TO DG SETS AT KEY LOCATIONS AT AFS BAREILLY UNDER GE (AF) BAREILLY
2024_MES_680926_1
GE(AF)/BLY/T-47/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) BAREILLY
₹79,620
Yes
23 Dec 2024
23 Oct 2024
27 Nov 2024
23 Oct 2024
25 Nov 2024
7 Nov 2024
Amount
Dismantling / stripping diesel engine of DG Det of 30 KVA rating capacity after separating alternator from common base frame setting a side for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detailed inspection complete all as specified and directed. (Note :- Spares shall be measurd & paid separately under relevent items of BOQ).
S&F in replacement of piston standard size of DG set 30 KVA Make- Kirloska/Ashoka Leyland etc complete all as specified.
All as per item No. 2.00 above but Piston Ring Cat part as in existing DG set.
All as per item No. 2.00 above but Piston Pin Cat part as in existing DG set.
All as per item No. 2.00 above but Cylinder liner (Sleeve) Cat part as in existing DG set.
All as per item No. 2.00 above but Exhaust valve Cat part as in existing DG set.
All as per item No. 2.00 above but Inlet valve Cat part as in existing DG set.
All as per item No. 2.00 above but packing kit Cat part as in existing DG set.
All as per item No. 2.00 above but Oil seal Cat part as in existing DG set.
All as per item No. 2.00 above but C.R bearing Cat part as in existing DG set.
All as per item No. 2.00 above but Kit "O" Ring Cat part as in existing DG set.
All as per item No. 2.00 above but fuel flexible pipe as in existing DG set.
All as per item No. 2.00 above but Oil Filter with gasket Cat part as in existing DG set.
All as per item No. 2.00 above but Diesel filter with gasket Cat part as in existing DG set.
All as per item No. 2.00 above but connecting Rod bush Cat part as in existing DG set.
All as per item No. 2.00 above but thrust washer Cat part as in existing DG set.
All as per item No. 2.00 above but valve guide inlet and outlet seat Cat part as in existing DG set.
All as per item No. 2.00 above but cylinder head gasket Cat part as in existing DG set.
All as per item No. 2.00 above but fuel injection pipes Cat part as in existing DG set.
All as per item No. 2.00 above but Air filter Cat part as in existing DG set.
All as per item No. 2.00 above but primary element as in existing DG set.
All as per item No. 2.00 above but Stop solenoid as in existing DG set.
All as per item No. 2.00 above but water pump as in existing DG set.
Dismantling / stripping diesel engine of DG Det of 100 KVA rating capacity after separating alternator from common base frame setting a side for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detailed inspection complete all as specified and directed. (Note :- Spares shall be measurd & paid separately under relevent items of BOQ).
S&F in replacement of piston standard size of DG set 100 KVA Make- Kirloska/Ashoka Leyland complete all as specified and directed.
All as per item No. 25.00 above but Piston Ring Cat part as in existing DG set.
All as per item No. 25.00 above but Piston Pin Cat part as in existing DG set.
All as per item No. 25.00 above but Cylinder liner (Sleeve) Cat part as in existing DG set.
All as per item No. 25.00 above but Exhaust valve Cat part as in existing DG set.
All as per item No. 25.00 above but Inlet valve Cat part as in existing DG set.
All as per item No. 25.00 above but packing kit Cat part as in existing DG set.
All as per item No. 25.00 above but Oil seal Cat part as in existing DG set.
All as per item No. 25.00 above but C.R bearing Cat part as in existing DG set.
All as per item No. 25.00 above but Kit "O" Ring Cat part as in existing DG set.
All as per item No. 25.00 above but fuel flexible pipe as in existing DG set.
All as per item No. 25.00 above but Oil Filter with gasket Cat part as in existing DG set.
All as per item No. 25.00 above but Diesel filter with gasket Cat part as in existing DG set.
All as per item No. 25.00 above but connecting Rod bush Cat part as in existing DG set.
All as per item No. 25.00 above but thrust washer Cat part as in existing DG set.
All as per item No. 25.00 above but valve guide inlet and outlet seat Cat part as in existing DG set.
All as per item No. 25.00 above but cylinder head gasket Cat part as in existing DG set.
All as per item No. 25.00 above but fuel injection pipes Cat part as in existing DG set.
All as per item No. 25.00 above but Air filter Cat part as in existing DG set.
All as per item No. 25.00 above but primary element as in existing DG set.
All as per item No. 25.00 above but Stop solenoid as in existing DG set.
All as per item No. 25.00 above but water pump as in existing DG set.
Dismantling / stripping diesel engine of DG Det of 250 KVA rating capacity after separating alternator from common base frame setting a side for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detailed inspection complete all as specified and directed. (Note :- Spares shall be measurd & paid separately under relevent items of BOQ).
S&F in replacement of piston standard size of DG set 250 KVA Make- Kirloska/Cummins complete all as specified and directed.
All as per item No. 48.00 above but Piston Ring Cat part as in existing DG set.
All as per item No. 48.00 above but Piston Pin Cat part as in existing DG set.
All as per item No. 48.00 above but Cylinder liner (Sleeve) Cat part as in existing DG set.
All as per item No. 48.00 above but Exhaust valve Cat part as in existing DG set.
All as per item No. 48.00 above but Inlet valve Cat part as in existing DG set.
All as per item No. 48.00 above but packing kit Cat part as in existing DG set.
All as per item No. 48.00 above but Oil seal Cat part as in existing DG set.
All as per item No. 48.00 above but C.R bearing Cat part as in existing DG set.
All as per item No. 48.00 above but Kit "O" Ring 7 B Cat part as in existing DG set.
All as per item No. 48.00 above but fuel flexible pipe as in existing DG set.
All as per item No. 48.00 above but Oil Filter B Cat part as in existing DG set.
All as per item No. 48.00 above but Diesel filter Cat part as in existing DG set.
All as per item No. 48.00 above but connecting Rod Assembly Cat part as in existing DG set.
All as per item No. 48.00 above but thrust washer Cat part as in existing DG set.
All as per item No. 48.00 above but valve guide inlet and outlet seat Cat part as in existing DG set.
All as per item No. 48.00 above but cylinder head gasket/Packet Kit Cat part as in existing DG set.
All as per item No. 48.00 above but fuel injection pipes Cat part as in existing DG set.
All as per item No. 48.00 above but Valve Solenoid as in existing DG set.
All as per item No. 48.00 above but Air Filter as in existing DG set.
All as per item No. 48.00 above but water pump as in existing DG set.
Dismantling / stripping diesel engine of DG Det of 320 KVA rating capacity after separating alternator from common base frame setting a side for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detailed inspection complete all as specified and directed. (Note :- Spares shall be measurd & paid separately under relevent items of BOQ).
S&F in replacement of piston standard size of DG set 320 KVA Make- Kirloska/Cummins complete all as specified and directed.
All as per item No. 70.00 above but Piston Ring Cat part as in existing DG set.
All as per item No. 70.00 above but Piston Pin Cat part as in existing DG set.
All as per item No. 70.00 above but Cylinder liner (Sleeve) Cat part as in existing DG set.
All as per item No. 70.00 above but Exhaust valve Cat part as in existing DG set.
All as per item No. 70.00 above but Inlet valve Cat part as in existing DG set.
All as per item No. 70.00 above but packing kit (Gasket)Cat part as in existing DG set.
All as per item No. 70.00 above but Oil seal Cat part as in existing DG set.
All as per item No. 70.00 above but C.R bearing Cat part as in existing DG set.
All as per item No. 70.00 above but Kit "O" Ring 7-B Cat part as in existing DG set.
All as per item No. 70.00 above but fuel flexible pipe as in existing DG set.
All as per item No. 70.00 above but Oil Filter B Cat part as in existing DG set.
All as per item No. 70.00 above but Diesel filter Cat part as in existing DG set.
All as per item No. 70.00 above but connecting Rod Assembly Cat part as in existing DG set.
All as per item No. 70.00 above but thrust washer Cat part as in existing DG set.
All as per item No. 70.00 above but valve guide inlet and outlet seat Cat part as in existing DG set.
All as per item No. 70.00 above but cylinder head gasket Cat part as in existing DG set.
All as per item No. 70.00 above but fuel injection pipes Cat part as in existing DG set.
All as per item No. 70.00 above but water pump as in existing DG set.
All as per item No. 70.00 above but Air Filter Cat part as in existing DG set.
Reassembling the diesel engine after top overhauling and installation in its original place/position including testing and commissioning of 30 KVA capacity DG Set Make- Kirloska/Ashoka Leyland complete all as specified and directed.
All as per item No. 90.00 above but for DG Set 100 KVA capacity.
All as per item No. 90.00 above but for DG Set 250 KVA capacity Make Kirloskar/Cummins
All as per item No. 90.00 above but for DG Set 320 KVA capacity Make Kirloskar/Cummins
Overhauling, servicing/calibration of FIP (fuel injection pump) assembly of DG Set 30 KVA Make: Kirloskar/Cumins/Ashoka Leyland for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detailed inspection complete all as specified and directed. Note :- Spares shall be measured & paid seperately under relevent items of BOQ.
S&F in replacement of Elements of FIP of DG Set 30 KVA Make- Kirloska/Cummins complete all as specified and directed (Note: Only unserviceble spare parts shall be replaced after inspection)
All as per item No. 95.00 above but Nozzle.
All as per item No. 95.00 above but Plunger.
All as per item No. 95.00 above but Delivery valve.
All as per item No. 95.00 above but Benjo Bolt.
All as per item No. 95.00 above but Bearing.
All as per item No. 95.00 above but Tappet roller bush pin.
All as per item No. 95.00 above but Control Rod.
All as per item No. 95.00 above but Fly weight assembly.
All as per item No. 95.00 above but Governer spring.
All as per item No. 95.00 above but Seat washer.
All as per item No. 95.00 above but Packing/Gasket.
Overhauling, servicing/calibration of FIP (fuel injection pump) assembly of DG Set 100 KVA Make: Kirloskar/Cumins for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detailed inspection complete all as specified and directed. (Note :- Spares shall be measured & paid seperately under relevent items of BOQ').
S&F in replacement of Elements of FIP of DG Set 100 KVA Make- Kirloska/Cummins complete all as specified and directed (Note: Only unserviceble spare parts shall be replaced after inspection)
All as per item No. 108.00 above but Nozzle.
All as per item No. 108.00 above but Plunger.
All as per item No. 108.00 above but Delivery valve.
All as per item No. 108.00 above but Benjo Bolt.
All as per item No. 108.00 above but Bearing.
All as per item No. 108.00 above but Tappet roller bush pin.
All as per item No. 108.00 above but Control Rod.
All as per item No. 108.00 above but Fly weight assembly.
All as per item No. 108.00 above but Governer spring.
All as per item No. 108.00 above but Seat washer.
All as per item No. 108.00 above but Packing/Gasket.
Overhauling, servicing/calibration of FIP (fuel injection pump) assembly of DG Set 250 KVA Make: Kirloskar/Ashoka Leyland for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detailed inspection complete all as specified and directed. (Note :- Spares shall be measured & paid seperately under relevent items of BOQ').
S&F in replacement of Elements of FIP of DG Set 250 KVA Make- Kirloska/Ashoka Leyland complete all as specified and directed (Note: Only unserviceble spare parts shall be replaced after inspection)
All as per item No. 121.00 above but Nozzle.
All as per item No. 121.00 above but Plunger.
All as per item No. 121.00 above but Delivery valve.
All as per item No. 121.00 above but Benjo Bolt.
All as per item No. 121.00 above but Bearing.
All as per item No. 121.00 above but Tappet roller bush pin.
All as per item No. 121.00 above but Control Rod.
All as per item No. 121.00 above but Fly weight assembly.
All as per item No. 121.00 above but Governer spring.
All as per item No. 121.00 above but Packing/Gasket.
All as per item No. 121.00 above but Seat Washer.
All as per item No. 121.00 above but Coolant for radiators.
Overhauling, servicing/calibration of FIP (fuel injection pump) assembly of DG Set 320 KVA Make: Kirloskar/Cummins for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detailed inspection complete all as specified and directed. (Note :- Spares shall be measured & paid seperately under relevent items of BOQ').
S&F in replacement of Elements of FIP of DG Set 320 KVA Make- Kirloska/Cummins complete all as specified and directed (Note: Only unserviceble spare parts shall be replaced after inspection)
All as per item No. 135.00 above but Nozzle.
All as per item No. 135.00 above but Plunger.
All as per item No. 135.00 above but Delivery valve.
All as per item No. 135.00 above but Benjo Bolt.
All as per item No. 135.00 above but Bearing.
All as per item No. 135.00 above but Tappet roller bush pin.
All as per item No. 135.00 above but Control Rod.
All as per item No. 135.00 above but Fly weight assembly.
All as per item No. 135.00 above but Governer spring.
All as per item No. 135.00 above but Seat washer.
All as per item No. 135.00 above but Packing/Gasket.
S&F in replacement of Governor Controller Assembly for 320 KVA DG sets Make - Kirloskar including installation, commissioning and testing complete all as specified and directed.
S&F in replacement of Digital Display Controller card complete for Electric Control Panel of 30 KVA DG set Make - Kirlosker
All as per item No. 148.00 above but for 100 KVA DG set.
All as per item No. 148.00 above but for 250 KVA DG set.
All as per item No. 148.00 above but for 320 KVA DG set.
S&F in replacement of Electric Actuator Assembly complete for 320 KVA DG sets Make - Kirlosker
S&F in replacement of self starter 24 Volt make Doosan or equivalent as per sample for DG Set complete for 320 KVA DG set Make - Kirlosker/Cumins
S&F in replacement of Priming Pump complete for 320 KVA DG sets Make - Kirlosker/Cumins
S&F in replacement of Relief Valve assembly complete for 320 KVA DG sets Make - Kirlosker/Cumins
Opening of Cylinder Head, tappings, Grinding, polishing of cylinder head, cylinder valve seats, valve guide etc and reassembling including tappet setting testing and trial complete all as required for best operation of DG Set 320 KVA Make- Kirloskar /Cumins/Ashok Leyland complete all as specified and directed
Opening of Cylinder Head, tappings, Grinding, polishing of cylinder head, cylinder valve seats, valve guide etc and reassembling including tappet setting testing and trial complete all as required for best operation of DG Set 250 KVA Make- Kirloskar /Cumins complete all as specified and directed
Opening of Cylinder Head, tappings, Grinding, polishing of cylinder head, cylinder valve seats, valve guide etc and reassembling including tappet setting testing and trial complete all as required for best operation of DG Set 100 KVA Make- Kirloskar /Cumins complete all as specified and directed
Opening of Cylinder Head , tappings , Griding, polishing of cylinder head, cylinder valve seats, valve guide etc and reassembling including tappet setting testing and trial complete all as required for best operation for DG Set 30 KVA Make- Kirloskar /Cumins complete all as specified and directed
Rectification of water contamination i.e. water entering in Oil Chamber including replacement of seals and gaskets and nut bolts etc complete all as specified and directed
Repair of Governor Controller including setting and adjustment of Droop speed mode control Fuel control , stability controll, over speed control and testing complete of DG set capacity 125 KVA DG set Make- Kirloskar/Cumins/Ashok Leyland
Repair of Governor Controller including setting and adjustment of Droop speed mode control Fuel control , stability controll, over speed control and testing complete of DG set capacity 250 KVA DG set Make- Kirloskar/Cumins/Ashok Leyland
S&F in replacement of Relay Card with Relay complete of Electric Control Panel of DG set of capacity 320 complete all as specified. Make- Kirloskar/Cumins
Dismantling of radiator of DG Set 30 KVA/100 KVA/250 KVA/ 320 KVA Make Kirloskar/ Ashok Leyland/ Cummins complete all as specified and directed.
S&F for radiators 30KVA/ 100 KVA/ 250 KVA/ 320 KVA DG Set of make Kirloskar/ Cumins/Ashok Leyland and replacement of new hose pipe set with clamp and fixing in original position and testing complete all as specified and directed.
Dismantling unserviceable self starter 12/24Volts of 100/ 250KVA DG set of Make Kirloskar/Cummins and repair/maint by replacement of worn out parts like bendix pinion, piston, bush housing armature field coil, carbon bushes etc and refixing and testing complete all as specified and directed.
All as per item No. 166 above but 320 KVA.
Supply , installation , commissioning and testing of self starter 24 Volt Make Lucas/Bosch or equivalent as per sample for 250 KVA DG set Make - Kirlosker/Cummins complete all as specified.
Supply , installation , commissioning and testing of self starter 12 Volt Make Lucas/Bosch or equivalent as per sample for 30 KVA DG set Make - Kirlosker/Cummins complete all as specified.
Supply , installation , commissioning and testing of self starter 12/24 Volt Make Lucas/Bosch or equivalent as per sample for 100 KVA DG set Make - Kirlosker/Cummins complete all as specified.
Dismantling of alternator from engine and stripping /opening replacement /rewinding the alternator with copper super enamelled wire of existing size and 'A' class insulation for 30 KVA alternator Make Kirloskar /Cummins and refixing after alignment complete all as specified and directed.
Dismantling of alternator from engine and stripping /opening replacement /rewinding the alternator with copper super enamelled wire of existing size and 'A' class insulation for 100 KVA alternator Make Kirloskar /Cummins and refixing after alignment complete all as specified and directed.
Dismantling of alternator from engine and stripping /opening replacement /rewinding the alternator with copper super enamelled wire of existing size and 'A' class insulation for 250 KVA alternator Make Kirloskar /Cummins and refixing after alignment complete all as specified and directed.
Dismantling of alternator from engine and stripping /opening replacement /rewinding the alternator with copper super enamelled wire of existing size and 'A' class insulation for 320 KVA alternator Make Kirloskar /Cummins and refixing after alignment complete all as specified and directed.
S&F in replacement of rectifier DG Set 250 KVA capacity Make Kirloskar complete all as specified and directed.
S&F in replacement of Hr Run M/ Hr Meter including RPM Meter cable connection through Engine by making provision as necessary as per site requirement complete all as specified and directed.
S&F in replacement of Core assembly of turbo charger for 320 KVA DG set Make - Kirloskar complete all as specified and directed.
S&F in repalcement of Turbo charger for 320 KVA DG set Make - kirloskar complete all as specified and directed.
S&F in replacement of oil pressure pipe as per sample Make : Ashoka Leyland complete all as specified and directed.
S&F in replacement of oil cooler for DG Set 30 KVA capacity of make Kirloskar complete all as specified and directed.
S&F in replacement of oil cooler for DG Set 250 KVA capacity of make Kirloskar complete all as specified and directed.
S&F in replacement of oil cooler for DG Set 320 KVA capacity of make Kirloskar complete all as specified and directed.
S&F for in replacement of Lubricating oil pump for DG set 30 KVA capacity of make : Kirloskar and testing complete all as specified and directed.
S&F for in replacement of Lubricating oil pump for DG set 250 KVA capacity of make : Kirloskar and testing complete all as specified and directed.
S&F for in replacement of Lubricating oil pump for DG set 320 KVA capacity of make : Kirloskar and testing complete all as specified and directed.
S&F in replacement of cut out 12 Volts automatic of Make : Lucas/Bosch and testing complete all as specified and directed.
S&F in replacement of ignition switch with replacement of auto wiring suitable for DG Set of any capacity & Make complete all as specified and directed.
S&F for in replacement of battery charger suitable for charging of battery 12 Volts 90/180 AH with charging current 0-10 Amp, input voltage 230 Plus complete all as specified and directed.
S&F for in replacement of alternator for battery charging 12 Volts 180 AH with pulley complete all as specified and directed.
S&F for in replacement of battery cables of 78 " long (+) size complete all as specified and directed.
S&F for in replacement of battery cables of 78 " long (-) size complete all as specified and directed.
S&F in replacement of Water Sensor (HWT)
S&F in replacement of Oil Sensor
S&F in replacement of Fan belt of B-48 size complete all as specified and directed.
S&F in replacement of Fan belt of B-57 size complete all as specified and directed.
S&F in replacement of Fan belt of AX-51 size complete all as specified and directed.
S&F in replacement of Fan belt of AX-52 size complete all as specified and directed.
Repair of Electric Panel of DG set capacity 320 KVA Make- Kirlosker /Cumins without any damage to the serviceable equipments complete all as directed.
S&F in replacement of Automatic Voltage Regulator (AVR) of DG Set 320 KVA capacity installed at Tech area including replacement of all minor and major parts like Ics, rectifier,diodes, capacitors, resistance, relay,printed circuit board etc. and re-fixing the same after complete repair and testing on load complete all as specified and directed.
S&F in replacement of Automatic Voltage Regulator (AVR) of DG Set 250 KVA capacity installed at Tech area including replacement of all minor and major parts like Ics, rectifier,diodes, capacitors, resistance, relay,printed circuit board etc. and re-fixing the same after complete repair and testing on load complete all as specified and directed.
S&F in replacement of Automatic Voltage Regulator (AVR) of DG Set 100 KVA capacity installed at Tech area including replacement of all minor and major parts like Ics, rectifier,diodes, capacitors, resistance, relay,printed circuit board etc. and re-fixing the same after complete repair and testing on load complete all as specified and directed.
S&F in replacement of Automatic Voltage Regulator (AVR) of DG Set 30 KVA capacity installed at Tech area including replacement of all minor and major parts like Ics, rectifier,diodes, capacitors, resistance, relay,printed circuit board etc. and re-fixing the same after complete repair and testing on load complete all as specified and directed.
S&F in replacement of Battery 12 Volt 150 AH Make: Exide/Luminous complete all as specified and directed.
S&F in replacement of Battery 12 Volt 180 AH Make: Exide/Luminous complete all as specified and directed
M&L for earthing complete with galvanized earth plate electrode of size 600 mm x 60 mm x 6 mm buried directly in ground vertically at a depth not less then 2.25 mtrs below normal ground level with top edge of earth plate at a depth not less then 1.5 mtrs below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized iron strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers made of galvanized iron and protected by light grade 40 mm bore GI pipe upto test point or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit in 1:3:6 type C-2 (using 40 mm grade stone aggregate) including excavation and earth work in any type of soil, returning filling in soil and disposal of surplus soil to a distance not exceeding 50 mtrs all as specified and shown on plate No 05 of SSR Part-I
S&F in replacement of power contactor 200 Amp 4 pole 415 volt complete all as specified.
S&F in replacement of power contactor 325 Amp 4 pole 415 volt complete all as specified.
S&F in replacement of power contactor 400 Amp 4 pole 415 volt complete all as specified.
M&L for rewinding of exciter coil of capacity up to 30 KVA DG set with copper wire complete all as specified and directed.
M&L for rewinding of exciter coil of capacity 250 KVA DG set with copper wire complete all as specified and directed.
M&L for rewinding of exciter coil of capacity 300 KVA DG set with copper wire complete all as specified and directed.
S&F in replacement of ON load Changeover switch 320 Amp 4 Pole 415 Volt Phase for LT panel complete all as specified and directed.
S&F in replacement of ON load Changeover switch 400 Amp 4 Pole 415 Volt Phase for LT panel complete all as specified and directed.
S&F in replacement of DG base card suitable for DG set of capacity 320 KVA make and model as per existing including necessary testing and commissioning complete all as specified.
S&F in replacement of DG base card suitable for DG set of capacity 250 KVA make and model as per existing including necessary testing and commissioning complete all as specified.
S&F in replacement of DG base card suitable for DG set of capacity 100 KVA make and model as per existing including necessary testing and commissioning complete all as specified.
S&F in replacement of DG base card suitable for DG set of capacity 30 KVA make and model as per existing including necessary testing and commissioning complete all as specified.
S&F in replacement of complete rewiring of DG set panel as per recommendation of manufacturer of the DG set as given in circuit diagram suitable for DG set of capacity 30 KVA as per existing size/gauge of wire with and including replacement of all uncerviceable connectors, fuses, minor electric parts and necessary testing and commissioning complete all as specified.
S&F in replacement of complete rewiring of DG set panel as per recommendation of manufacturer of the DG set as given in circuit diagram suitable for DG set of capacity 100 KVA as per existing size/gauge of wire with and including replacement of all uncerviceable connectors, fuses, minor electric parts and necessary testing and commissioning complete all as specified.
S&F in replacement of complete rewiring of DG set panel as per recommendation of manufacturer of the DG set as given in circuit diagram suitable for DG set of capacity 160/200 KVA as per existing size/gauge of wire with and including replacement of all uncerviceable connectors, fuses, minor electric parts and necessary testing and commissioning complete all as specified.
S&F in replacement of complete rewiring of DG set panel as per recommendation of manufacturer of the DG set as given in circuit diagram suitable for DG set of capacity 320 KVA as per existing size/gauge of wire with and including replacement of all uncerviceable connectors, fuses, minor electric parts and necessary testing and commissioning complete all as specified.
S&F in replacement of shut down valve for 320 KVA DG set including necessary electric connection to AMF panel and engine control panel board all as specified. Make : Cummins/Kirlosker diesel engine
S&F in replacement of shut down valve for 250 KVA DG set including necessary electric connection to AMF panel and engine control panel board all as specified. Make : Cummins/Kirlosker diesel engine
S&F in replacement of shut down valve for 30 KVA DG set including necessary electric connection to AMF panel and engine control panel board all as specified. Make : Cummins/Kirlosker diesel engine
S&F in replacement of MCCB 250 Amp four pole 415 volt braking capacity 35 KA adjustable thermal and adjustable magnetic setting CN frame complete all as specified.
S&F in replacement of MCCB 400 Amp four pole 415 volt braking capacity 36 KA adjustable thermal and adjustable magnetic setting CN frame complete all as specified.
S&F in replacement of MCCB 160 Amp four pole 415 volt braking capacity 35 KA adjustable thermal and adjustable magnetic setting CN frame complete all as specified.
SONI ENTERPRISES (BID ID -3164085)
M/s Agarwal Builders (BID ID -3173313)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .