| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹42.4 L+₹2.0 L (4.89%)Rejected-AOC 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹42.4 L+₹2.0 L (5.01%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹43.8 L+₹3.4 L (8.42%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹44.5 L+₹4.1 L (10.2%)Rejected-AOC 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
24 Dec 2022, 6:00 pmClosed
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVN OF WEATHER SHELTER, CERTAIN BR WORKS AND GARBAGE BIN AT INAZ VILLAGE, ICGS VERAVAL UNDER GE I CG PORBANDAR
2022_MES_567518_1
8808
Open Tender
Civil Works
Item Rate
180 days
VERAVAL
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹76,000
Yes
11 Jan 2023
6 Dec 2022
26 Dec 2022
6 Dec 2022
24 Dec 2022
17 Dec 2022
Amount
SCHEDULE 'A'
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose Soil complete all as specified and directed
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc n exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed
M&L for PCC 1:4:8 type D2 (using 40mm graded aggregate) in foundations, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge complete all as specified and directed
Use and waste of formwork to the sides of concrete footing, base of columns, plinth beams and similar work for vertical or to batter rough finished surfaces of concrete complete all as specified and directed
M&L for Reinforced cement concrete, 1: 1.5 : 3, type B1 nominal mix (using 20 mm graded aggregate) in foundation, footing, foundation beams, plinth Beam, base of columns complete all as specified and as directed.
Use and waste of formwork to the sides of rectangular columns for rough finished surfaces of concrete complete all as specified and directed
M&L Reinforced cement concrete 1: 1.5 : 3, type A1 nominal mix, using 20 mm graded stone aggregate, as in Columns, pillars, piers, posts and struts, complete all as specified and directed.
Use and waste of formwork to sides and soffits of beams, bands and the like for rough finished surface of concrete.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for Reinforced cement concrete, 1: 1.5 : 3, type A1 nominal mix (using 20 mm graded aggregate), as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.
M&L for Reinforced cement concrete, 1: 1.5 : 3, type A1 nominal mix (using 20 mm graded aggregate, as in chajja & canopy, complete all as specified and directed.
M&L for Reinforced cement concrete, 1: 1.5 : 3, type B1 nominal mix (using 20 mm graded aggregate), as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.
Use and waste form work to edges of roof slab exceeding 5 cm but not exceeding 10 cm to be rough finished.
M&L for Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for Mild steel CRS TMT bars 6mm to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for slabs, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and directed.
All as per item No. 15 here-in-before, but but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed.
M & L for precast concrete block masonry with solid block n.exc 20 cm width type C1, 1:3:6 setting in cement mortar (1:6) complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soft/loose soil.
Removal of excavated soil to a distance exc. 500m but n.exc 1000 mtr and depositing where directed at level n exc. 1.5M above the starting point. all as specified.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
M&L For Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick PCC (1:3:6) type C2 using 40 mm graded aggregate as in sub bases of flooring, complete all as specified and directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including screed bed or bedding layer of 15 mm thick 1:6 etc. complete all as specified and as directed by Engr-in-Charge
M&L for rendering 15mm thick, in cement mortar (1:4) on wall surfaces finished even and smooth without using extra cement,complete all as specified and directed.
M&L for rendering 5mm thick cement plaster in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on ceiling in any height complete all as specified and directed.
M&L for Rendering 10mm thick on fair faces of stone work or concrete surfaces in cement mortar 1:3, finished even and smooth w/o using extra cement using liquid water proofing compound as per manufacturer's instructions over roof slab surfaces etc., complete all as specified. NOTE:- WPC shall be measured and paid separately under respective items
Supply only liquid water proofing compound.
M&L for preparation of surfaces and applying three coats of white wash on new plastered surfaces of wall complete all as specified and as directed.
M&L for preparation of surfaces and applying three coats of white wash on new plastered surfaces of ceiling complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturers instructions, complete all as specified and directed by Engr-in-charge.
S&F for Powder coated aluminium anodised two track sliding window shutter and frame including jointing cleat for fixing frame/chowkhat of window as per JINDAL section code (frame 20831), shutter (20846) including glazing with 4mm thick tinted glass (02 shutters) necessary fittings, rubber packing, suitable handles, rollers for shutters etc complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over 15 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M&L for Glazed coloured ceramic tiles in vertical surfaces 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick screed bed of CM 1:4 etc., complete all as specified and directed.
M & L for powder coated Aluminium Anodised frame for door, sliding with one or more rebates including joining cleats for fixing etc. Rubber gasketting all round the panels/ shutters to fix glass, PVC gasketting in all channels, (minimum thickness of powder coating 50 micron and anodizing thickness 15 microns ) complete all as specified and directed.
M & L for powder coated Aluminium Anodised shutter for door, with one or more rebates including joining cleats for fixing etc. Rubber gasketting all round the panels/ shutters to fix glass, PVC gasketting in all channels, (minimum thickness of powder coating 50 micron and anodizing thickness 15 microns) including hinges, handles and locking arrangement complete all as specified and directed.
S&F 5.5 mm thick tinted glass ordinary quality ground or obscured or frosted, on one side and glazing with oil putty in square exc. 0.5 sqm in each pane complete all as specified and directed.
M&L 12 mm thick prelaminated (Both sides) Medium density fibre board exterior grade fixed with screws or glazing clip, fixed with panels to aluminium doors/partitions complete all as specified and directed.
S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
M&L for Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples, including fixing on ventilators channels, complete all as specified and directed by Engr-in-Charge.
S&F for 4 mm thick, plain glass area exc 0.50 sqm each pane fixed in aluminium frame as in windows/ Ventilators, including glazing clips and beading, complete all as specified and directed by Engr-in-Charge.
Material & Labour for 75mm thick plain cement concrete B-2, 1:2:4 type B-2(using 40mm graded crushed stone aggregate) as in plinth protection finished fair and even without using extra cement complete all as spd & directed. Note:- The plinth protection shall be laid in pannels and length of the each panel shall not be more than 2.00 SQM all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the above item.
M&L for 100 mm thick PCC (1:3:6) type C2 (using 40 mm graded aggregate) as in sub bases of flooring, complete all as specified and directed.
M&L for 25mm thick sand layer for laying interlocking paver blocks all as specified and directed by Engr-in-Charge at site.
M&L for laying machine pressed precast conctete interlocking reflective coloured pavers block any shape and size confirming to IS 15658-2006 of 60mm thick, M-35 Grade, including interstices filling with fine sand etc., complete all as specified and directed by Engr-in-Charge at site.
M&L for cement concrete type B-1 (1:2:4) using 20 mm graded stone aggregate as in coping, moulded or chamferred edges and like complete.
M&L Double charged Vitrified Ceramic Tiles, light shade 9 to 10mm thick (Square/Rectangular), area of each tile not exceeding 0.36 Sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick bedding layer in Cement Mortar 1:6 complete all as specified and as directed by Engr-in-Charge.
Material and labour for Mild steel screw bolts 16 - 20 mm dia neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n exc 30cm long, including fixing/ welding on gusset plate and embeding in concrete, complete all as specified and directed.
M&L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165, complete all as specified and directed.
M&L for 4 mm thick glass mosaic tiles of size (20 mm x 20 mm) superior quality as in water fountain, swimming pool, water curtain etc., including preparation of newly plastered surfaces by applying epoxy grout with pigment and epoxy backing coat, complete all as specified and as directed by Engr-in-Charge.
M&L for matt finish designer outdoor tiles of size 300 mm x 450 mm superior quality as in cladding for wall over and including 10 mm thick rendering in cm 1:4, complete all as specified and directed.
S&F Fabrication and Painting of 100% detachable Victorian Style Decorative ornamental Cast Iron Gazebo by ISO Certified Company. Overall size of Gazebo should be 4600mmX4600mm in Square Shape & total height is 3970mm.The roof should be in square shape 5220mm x 5220mm. Special cut pattern roofing like slate or wooden shakes. Multilayer roofing shingles made of Bitumen shingles should be resistant to harmful environmental impacts, decay, corrosion, fire damage. These shingles manufactured on a base of APP modified bitumen compound fixed with torch-on application. Roof should be fix on decorative ornamental Combo Cast Iron Pole of height 2660mm & MS pipe on top of pole to support roof structure. Thickness of all cast iron part must be 10-12mm. For fixing of Top Grill & Support Corner Grill on Pole, Pole must have M.S Pipe. Cast iron support corner grill - quantity 08 Nos. Customize combo Bottom Railing Quantity - 11 Nos. Specification – 1340mm X 690mm, Fabricated with D type MS pipe for handrail. Nut Bolt for connecting all these parts should be of SS 304 grade. Welding process shall be done by Metal Inert Gas (MIG) welding process using Carbon Dioxide (CO2) gas. Color specification & finishing process must follow as per the ISI standard. All parts must be clean by SHOT blasting process. Further parts are painted in 4 layer coating (Coating thickness-125 to 150 micron) in which first layer with epoxy primer (to prevent corrosion), second layer with epoxy base color, than third layer polyurethane (PU) metallic paint (Gold/Green/Copper/Silver) & final layer of polyurethane (PU) lacquer (to prevent ultra violets ray). (Material Specifications):- All this above cast iron components must be of FG-150 grade as per IS210 (2009) standard, Hardness must being range between 130BHN to180 BHN. Cast iron must have Chemical composition of Carbon -3.0% to4.0% Silicon- 1.0% to 2.0%, magnesium -0.5% to 0.7%,sulphur -0.02% to 0.04% &phosphorous-0.07% to 0.09%.
Supply, Installation, testing and commissioning of Incinerator electric type complete with SS 304 having combustion chamber supported with electric coil, capacity 50 KG /Batch, Overall size of the incinerator is 110 CM Dia X 180 CM Height with a chimney complete as required at site and as directed comprising with the following :- (a) Burning/Combustion Chamber:-Incinerator has a combustion chamber, completely made of Stainless Steel (304 Grade). (b) Electric Hot Plate: Electric Incinerator should be fitted with hot plate for easy burning of the wet wastes. A blower fan is also provided for supply of oxygen contained in the atmospheric air for easy combustion of waste inside the incinerator. (c) Bottom Side Opening: - The Cyclone Chamber has a conical shape for easy discharge of ash to the sides of the incinerator. The Ash falls to an SS tray for easy collection and disposal. Quality of ash depends on the type of materials that are burned. Sticky materials like rubber, plastics etc when burned, has every tendency to clog the bottom openings. (d) Ash Tray: Bottom Ash Tray is also made of SS 304 grade material and is designed in such a way that it can accommodate complete ash of the day. (e) Double shell Stainless Steel Incinerator with thermal insulation fitted with Electric Hot plate. Overall minimum size of the incinerator is suitable size for material loading and for easy cleaning. (f) Wet Scrubber Unit fully made of SS 304 with an Induced Draft Blower: This unit consists of a scrubber with air entry, water spray system. A blower that is installed at the bottom end point of the scrubber unit sucks the smoke from the cylcone along with some quantity of atmospheric air.
(e) Double shell Stainless Steel Incinerator with thermal insulation fitted with Electric Hot plate. Overall minimum size of the incinerator is suitable size for material loading and for easy cleaning. (f) Wet Scrubber Unit fully made of SS 304 with an Induced Draft Blower: This unit consists of a scrubber with air entry, water spray system. A blower that is installed at the bottom end point of the scrubber unit sucks the smoke from the cylcone along with some quantity of atmospheric air. Note: (i) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the set and height of plinth shall not be less than 0.5 M (ii) Suitable sheet shelter made out of Brick wall and GI pipe/ angle iron frame with GI Sheet roof, etc. as per manufacturer direction shall be included in the over all rate quoted. (iii) Tool kit, Operation and maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(g)Technicical specifications for Eletric Incinerator:- (i) Incinerator:- (aa)Type of waste: General/Food waste (ab) Bruning cpapcity: 50 Kg/hr (ac) Mode of cumbustion: Heating elements, 2000 Watts x 04 Nos (ii) Primary Chamber:- (aa) Type: Static Solid Hearth (ab) Type of material : MS Plate/SS 304 (ac) Primary chamber: Stainless steel
(ad) Insulation Material : Insulation Bricks as per IS Standards (ae) Temperature Resistance: 800 degrees Celsiuse (+/-500 degree) (af) Insulation Thickness: 115mm (iii) Secondary combustion chamber:- (aa) Outer Body MOC: mild steel (ab) Insulation bricks (ac) Operating temperature : 1050+/-50 degree Celsius. (iv) Including three phase 440 volt 50 Hz Digital control panel including Indicators, In coming & Outgoing controls, Contactors, single phase preventer, Volt meter, hour meter, etc. (v) Combustion/FD Fan : Air blower as per manufacturer specification etc.. complete all as spd and directed by Engr-In-Charge. Make: Agro Machinery & consultancy Pvt Ltd or Equivalent
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 50 Sqmm 3.5 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc all connections complete as required at site and as directed. Make : Polycab/Havells/RR Kabel
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil complete all as specified and directed.
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply and lay 77/63 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. Make: Rex/Poly/Gemini
Supply and Fix MCCB Polycarbonate enclosures with MCCB FP 63 Amps 415 Volts 16 KA fixing in Polycarbonate enclosure, in wall mounted type Surface mounted and making good the disturbed surfaces of walls/ceiling/floor etc. complete with all accessories, main switch and connecting the cables with proper all as specified and directed by Engineer in Charge. Make: Legrand / Hager/L&T/ Hensel or Equivalent
M&L for bore Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion complete all as specified and directed.
Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:- a) One light /fan point controlled by one, one way switch
b) One 3 pin 6 Amps socket outlet on same board
c) One 3 pin 6 Amps socket outlet on independent board .
M&L for Point wiring complete with 2.5 Sq mm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISi marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sq mm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules all as specified.
Supply & fix modular switch 1 way, 16 Amps, 1 modular (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular switch 1 way, 6 Amps, 1 modular (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked) complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular fan regulator, 120 watt, 2 module (ISI marked) complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix ceiling rose, surface bakelite, 65 x 17 mm three terminals (ISI Marked) complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
S & F in of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed. Make: Wipro - CAT PT No- LL20-281-XXX-65AL1** or equivalent to Bajaj/Havells
Supply & fix BEE star rated Ceiling fan 1200 mm sweep and connecting up to and including provision of flexible three core PVC insulated copper conductor cable from ceiling rose to fan etc complete all as specified and as directed. Make: Orient, CG, Havells, Usha
Supply and fix Exhaust fan 300 mm sweep 240 V AC metal body fixed as per maufacturers instruction, connecting with and including 2 core x 0.5 Sqmm copper coduct PVC insulated and PVC sheathed three core cable complete or equivalent. Make: Orient, CG, Havells, Usha
M&L for sub main wiring with two single core 4 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 2.5 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
S & F MCB DB 8 way SPN, double door, vertical type, IP - 53 with 200 Amps rated bus bar, Concealed and connecting up complete all as specified. Make : Legrand/ Havells/ ABB
Supply and fixing MCB SPN, 240 volt, 'C' series,32 Amps complete all as specified. Make : Legrand/ Havells/ ABB
Supply and fixing MCB SP, 240 volt, 'C' series 6 to 32 Amps complete all as specified. Make : Legrand/ Havells/ ABB
Supply and fix earthed metal clad socket outlet with earthed plug top 20 Amps capacity with sheet metal enclosure and one 20 Amps MCB SPN all as specified and directed. Make : Legrand/ Havells/ ABB
RAJ ENTERPRISE
K K Construction Co
M/S. P.M GODHANIYA
shree chamunda enterprise
K B N TRADERS
SHREEJI ENTERPRISE
BABUBHAI BHIMABHAI PANDAVADRA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .