Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC 164 A 11 GALI NO 3 RISHI NAGAR KAITHAL 136027 | KAITHAL | HARYANA | 136027 | L1 | Accepted-AOC Lowest |
Tender Value
₹20.5 L
EMD Value
₹40,940
Closing Date
10 Sept 2020, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Divn. PWD B and R Br., Ambala Cantt.
Const. of Govt. ITI at village Nachron in Distt. Yamuna Nagar (Pdg. Sub Station) (Recall).
2020_HRY_136748_2
PWD/Elect-KNL/Elect-AMB/100013
Open Tender
Construction Works
Works
120 days
Ambala Cantt
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
E.E., Elect. Division PWD B and R Br.,
₹40,940
12 Nov 2020
27 Aug 2020
11 Sept 2020
28 Aug 2020
10 Sept 2020
28 Aug 2020
Amount
1 : - ( c ) Moulded case Circuit breakers. Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 100 amp.to 220 amp.415 V,10 KA 3-phase. 31.12 c (ii)
: - 250 amp. 415 V , 35 KA 3-phase. 31.12 c (iii)
: - 300 amp. to 400 amp. 415 V , 35 KA 3-phase. 31.12 c (iv)
2 : - (P) Pipe Laying. Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Galvanised iron pipe 40 mm dia on flushed. 31.21 (xii)
: - Galvanised iron pipe 65 mm dia on flushed. 31.21 (xiv)
3 : - (Q) Earthing Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. 31.22(iii)
: - Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) comlete as equired. 31.22(iv)
: - Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. 31.22(v)
: - Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required . 31.22(x)
: - Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material. 31.22(xiv)
: - Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required . 31.22(xi)
: - Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material. 31.22(xv)
4 : - Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 240 Sq. mm 3.5 Core Armoured Cable. 31.26 (xxxiii)
: - 95 Sq. mm 3.5 Core Cable . 31.26 (xxix) Ard.
5 : - Supply and erection of suitable compression type brass cable glands for underground Cable. 70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core . 31.28(iv)
: - 240 Sqmm Cable 3 to 3.5 Core . 31.28 (vi)
6 : - ( T ) Street Light. Supply and erection of prestressed cement concrete pole as per IS:1678-1960. 9 metres long 105 mm x 115 mm at top and 105 mm x 315 mm at bottom with working load of 200 Kg. burried 1.80 m in ground. 31.30 (VI) (ii)
7 : - (U)Bus Bar chamber (a) Copper. (X) Miscellaneous . Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S.rod welded / revitted at the top with 10 cm. Dia 5 mm thick G.I.plate inscribed with `cable' world on it , having a cross arm 30 cm. long of the same dia welded at the bottom , in existing trench 45 cm. below ground level . 31.35 (xi)
8 : - Supply ,installation,Testing & Commisioning of wall / free standing floor mounting dust & vermin proof compartmentlised Cubical Panel made out of 2mm thick CRCA sheet steel required hardware 3mm thick bakelite sheet provided all along the bus bar & cable alley seperating switches compartment & supporting suitable channel duly painted by 2 coat of zinc / red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/ Neoprane rubber gasket of not less than 3 mm thickness, seperate detachable gland plate, MS base channel ,hinged door with interlocking arrangement for equipment /switchgear. Transperant acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet of 3mm thick for seperating cable alley to BBC from switch chamber Extended solid copper bus bars upto cable alleys shall be provided for outgoing connections which shall be paid as extra items. Side walls & cable alley compartments shall be having bolted type doors with detachable extension type structure .The panel will be complete with control wiring (copper) & fuse protection. (Only outer area on all sides shall be measured). 31.63
9 : - Suppying & fixing of copper bus bar duly tinned by means of SMC /DMC type insulator high tensile nuts & bolts spring washers fixing to same in existing panel including bending, cutting in required shape & size & insulation with colour coding heat shrinkable PVC insulation complete in all respect. 31.64
11 : - Supply & fixing of rotary handle for ON /OFF operation of existing MCCB in the LT Panel including fixing the same in position with all labour & material required to complete the job in all respect. Rotary Handle above 125A, MCCB 31.66 (ii)
12 : - S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 Mtr. Below ground level including diging and refilling of earth including cost of suitable size socket cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer- incharge of the work. HDPE Pipe 145/123 outer dia / inner dia. 31.67 (iii)
13 : - Supply & erection of Module case circuit breaker single pole / 4 pole on wall/ on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. 4 pole MCCB 500 amp. 31.69 (viii)
14 : - Supply & erection of XLPE (E) 11 KV HT aluminium conductor armoured cable ISI mark laid in existing pipe/ trenches/ surface with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. 50 sqmm 3 core XLPE cable 31.71 (ii)
15 : - Supply and erection of heat shrinkage type end termination joinnting kit indoor type of suitable to accommodate 3 core 11 KV XLPE aluminum cable / ABC cable complete wityh all the kit comtent including earth continuing connection along with 3 nos.crimpling type aluminum lugs of suitable capacity including making joining etc complete in all respect. Suitable for 16 to 50 sqmm 3core XLPE Cable 31.72 i
16 : - Supply and erection of heat shrinkage type end termination joinnting kit outdoor type of suitable to accommodate 3 core 11 KV XLPE aluminum cable / ABC cable complete with all the kit comtent including earth continuing connection along with 3 nos.crimplin type aluminum lugs of suitab;le capacity including making joining etc com[plete in all respect. Suitable for 16 to 50 sqmm 3core XLPE Cable 31.73 i
17 : - SITC of indoor type 315 KVA 11/0.433 KV, 50Hz Oil filled, cast resin transformer complete in all respect upto the entire satisfaction fo Engineer- in Charge of work. Make -Alstom, Bharat Bijlee, Kirloskar, Crompton, NGEF, Voltamp, ABB, Siemens, Schneider. Rating -315KVA No Load Voltage Ratio (KV) -11/0.433KV No. of Phase 3 Frequency Cycle 50Hz Type - Oil filled Type Cooling AN Duty Indoor Connection -HV/LV -Delta / Star Vector Group - Dyn -11 Tapings on HV Compensation: +5% to -5% In steps of 2.5% Tempearture Rise ( Winding ) Ambient : Not Exceeding 90Deg C. " OFF Circuit" Tap Changer Insulation Class: F HV Termination - Cable Box LV Termination - Cable Box Proteciton Class: IP 23 Standard: BIS 2026/ 1977 & IS 11171-1985 Supprot: Bi directionals rollers 4Nos. Paint Shade: RAL -7032 ( Siemensa Grey ) Limit Swict for interlocking tapping link cover Earthing Lugs/ Studs Complete in all respect NS-1
18 : - S/E of 11KV gang operated switch Rashtriya / Jayshree / BHEL make conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing 'H'pole with the help of 3 Nos. channels of size 75mmx40mmx6mm, 1.8M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 Nos. 11KV insulator with GI pin, RD fuses and painting with 2 coat of approved paint and one coat of red oxide material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the works. NS-3
19 : - S/E of lighting arrestor model ALPRO / Alastom/ LEMCO make suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resistar element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. NS-4
20 : - Supply of 11KVPin Insulator Brown colour with 11KV Gi Pin Jay Shree make with Disc fitting T&C type complete in all respect with erection of the same upto the entire satisfaction of the Engineer in Charge of work NS-5
21 : - S/E of Rubber mat of size 2mX1m & 12 mm thick suitable for 11 KV complete in all res. NS-6
20 : - Supply & Erection MS bucket stand which including cost of 6 nos. buckets of 9 liter capacity with sand filling including cost of welding & painting of complete stand & buckets with one coat of red oxide and two coats of approved paint of red colour with all labour & petty material to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. NS-7
22 : - SITC of LT Capacitor Bank Panel 95 KVAR capacity compete in all respect upto the entire satisfaction of engineer-in charge of work. Incomer side MCCB 250 A 3P =1No. ROH=1No. SPREADER LINKS =1No. APFC RELAY =1No. MCB SP 2/6A =3Nos. Control Terminal =8Nos. 10 KVAR CAPACITOR FEEDER MCB 32 A TP CAP DUTY =2Nos. CONTACTOR CAP.DUTY. 10 KVAR =2Nos. PUSH BOTTEN =4Nos. ON INDICATION =2Nos. AUTO-MANUAL SWITCH =2Nos. 6 Amp Control MCB SP =2Nos. 15 KVAR CAPACITOR FEEDER MCB 32 A TP CAP DUTY =1No. CONTACTOR CAP.DUTY. 15 KVAR =1No. PUSH BOTTEN =2No. ON INDICATION =1No. AUTO-MANUAL SWITCH =2Nos. 6 Amp Control MCB SP =2Nos. 20 KVAR CAPACITOR FEEDER MCB 63 A TP CAP DUTY =3No. CONTACTOR CAP.DUTY. 20 KVAR = 3Nos. PUSH BOTTEN =6Nos. ON INDICATION =3Nos. AUTO-MANUAL SWITCH =3Nos. 6 Amp Control MCB SP =3Nos. BUS BAR (B) Bus Bar will be of Electrolytic COPPER of size:250A ENCLOSURER ( C) CRCA sheet steel enclosure. Panel will be fabricated with 14SWG CRCA sheet steel for load bearing surfaces and 16SWG for non load bearing surfaces. Tentative Dimensions - 650 X 1900 X 500 MM WIRING (D) Harness for starter & metering, Thimbles, Ferrules, Sleeves, PVC channel, Gourmets, Braided wire for earthing etc HARDWARE (E) (Nuts, Bolts, Spring washers, Door hinges, Door Locks & Key, Lifting hocks, Base channel, C-type Channels, DMC Busbar Insulators etc) ACCESSORIES (F) Danger plate, Feeder detail Inscription plates, Acrylic/Bakelite/Perforated sheet cover for busbar, Door gasket etc. NS-8
23 : - Supply , Erection , testing & comissioning of 11 KV outdoor type HT Metering panel complete with CTs , PTs cubical and electronics Meter with accuracy class 0.2 as per requirement / approved by UHBVN. Panchkula Electrical Supply consisting of following : Cubical panel free standing floor mounting type made of sheet steel 14 G SWG CRCA sheet with channel iron base frame spray painted with strong synthetic grey channel paint as per size & design approved by UHBVN. PANCHKULA Electrical Supply.Out door Type with outer canopy. ii)3 nos. 11 KV CTs of rating as approved by UHBVN Panchkula. Chandigarh Electrical Supply for indoor installation of appr.make of UHBVN Panchkula Electrical Supply. iii)1 no. 11 KV PTs 11000/110 volts 10 VA burden 0.2 accuracy oil filled suitable for indoor installation of approved make of UHBVN Panchkula Electrical Supply . iv)Digital electronics meter 3 Phase 4 wire 11000 / 110 volts 10 VA burden 0.2 accuracy for recording reading of KWH of make and rating approved by UHBVN Panchkula Elect.Supply with push button display operating system for diff. kind of readings . v)Foundation of Suitable Size 300mm above ground level made of CC having suitable size to hold metering panel vi)Outer housing fab by 2mm thick CRCA sheet to cover the HT Metering Panel from rain water alongwith agnle iron frame. vii) The cubical panel will be complete in all respect including interconnections , internal wiring with PVC copper cable its testing / approval of all items by UHBVN Panchkula Electrical Supply with a gurantee of one year from the date of commissioning including cost of all labour & material required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work. NS-9 i)
24 : - Supply & erection of MS channel, angle iron and MS flat of different size on existing PCC pole for fixing & erection of transformer insulator cable also for making of the required size of tray for cable etc. including painting with two coat of approved paint and one coat of red oxide complete in all respect upto the entire satisfaction of Engineer-in-charge of work. NS-10
25 : - Const. of Cement concrete bricks basement for transformer & metering panel of size 5"X4"X3" Complete with Plaster L/S NS-11
26 : - Supply & erection of jalli upto 6 ft height fancing in HT area with concrete blocks complete in all respect upto the entire satisfaction of Engineer-in-charge of work. NS-12
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .