Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
29 Nov 2021, 6:00 pmClosed
GE 969 EWS
GE 969 EWS
SPL REPAIR TO TILLING PANELING ON SIDE WALLS OF BLDG NO T- 53 T-59 , SPL REPAIR TO FOL DUMP, MAIN OFFICE, GD CDR ROOM AND PROVN OF KOTA STONE FLOORING FOR FRESH ISSUE SHED ,SPL REPAIR TO BLDG NO T- 56, 58, 59 (OR LIVING) FOR 163 BN (TA) (HH), SPL
2021_MES_485824_1
CANO 969/WS- /2021-22
Open Tender
Civil Works
Item Rate
270 days
Pattan
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 969 EWS
₹97,000
Yes
22 Jan 2022
2 Nov 2021
30 Nov 2021
2 Nov 2021
29 Nov 2021
16 Nov 2021
Amount
Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above grond level complete all as specified and directed by Engineer-in-charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-charge.
Dismantling of floor hearth wall tile incl cement mortar bedding, removing serviceable tiles to store and rubbish of f the permishes in cement mortar complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster a screed bedding layer of any description from wall/concrete surface including raking out joints hacking for key scrubbing douwn with water etc. complete all as specified and directed by Engineer-in-charge.
Dismantling of wall and celling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness inlcuding cover fillets.
Taking down chowkats or frames but with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm and not exceed 4.00 sqm complete all as specified and directed by Engineer-in-charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm complete all as specified and directed by Engineer-in-charge.
Demolition of stone masonary or boulder masonry built in cement mortar complete all as specified and directed by Engineer-in-charge.
Dismantling timber scantlings 40 sqcm and over in section in any position unframed work complete all as specified and directed by Engineer-in-charge.
M&L Cement concrete B1 1:4:8 (40 mm graded aggregate) in foundations, filling and mass concrete as a sub base complete all as specified and directed by Engineer-in-charge.
M&L Providing, cement concrete Type C1 1:3:6 (20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges, in plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-charge.
S&F 2nd class Softwood eaves boarding 20 mm thick, fixed with nails in any situation (except flooring and skirting) Clean sawn with butt joints complete all as specified and directed by Engineer-in-charge.
S&F Weather boarding, 25 mm thick, wrought both sides, V-jointed to give 20mm laps complete all as specified and directed by Engineer-in-charge.
M&L galvanised,corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with coach screw and washers in roofs, walls etc complete all as specified and directed by Engineer-in-charge.
All asd per item no 16 but except sheeting (any thickness) complete all as specified and directed by Engineer-in-charge.
S&F plain, galvanised, mild steel sheeting .80 mm thick, in ridges, hips, valley gutters, drip and straight flashings(length and girth as fixed) with grade of zinc coating 120gm complete all as specified and directed by Engineer-in-charge.
M&L Preparation of new steel surfaces of any description priming with red oxide two coat synthetic enamel paint, over 10cm in width or girth,not otherwise described complete all as specified and directed by Engineer-in-charge.
M&L Prepation of steel surfaces of any description one coat synthetic enamel paint , over 10cm in width or girth,not otherwise described complete all as specified and directed by Engineer-in-charge.
M&L Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including marble border linning 75 mm wide rubbing and polishing complete incl 20mm thick screed in CM 1:4 complete all as specified and directed by Engineer-in-charge.
S&F Plain, framed, second class soft wood panelled shutters 35 mm thickness (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats complete all as specified and directed by Engineer-in-charge.
S&F in repair sinks made of stainless steel 1 mm thick without draining board kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe,overall size 495mmx420mm bowl size 410mm x330mmx160mm complete all as specified and directed by Engineer-in-charge.
S&F in repairs pillar taps, 15 mm dia cast copper alloy fency type with capstan heads, chromium plated. screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts screwed for iron pipe complete all as specified and directed by Engineer-in-charge.
Taking up or down bore of pipes 15 mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-charge.
S&F 15 mm Tubes, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
M & L Granite 20 mm thick (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-charge.
M&L Glazed ceramic tiles in vertical surface 600 x300 x10 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including screed bed 10 mm thickness in CM (1:4) all complete all as specified and directed by Engineer-in-charge.
M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 all as specified and directed. complete all as specified and directed by Engineer-in-charge.
M & L Vitrified Ceramic tiles light shade 10 mm thick incl 75 mm wide border lining of maroom shade tile (square/ rectangular) area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Incl screed bed 10 mm thick in CM (1:4) complete complete all as specified and directed by Engineer-in-charge.
M & L Vitrified Chequered tiles light shade 10 mm thick wide border lining of maroom shade tile (square/ rectangular) area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Incl screed bed 10 mm thick in CM (1:4) complete all as specified and directed by Engineer-in-charge.
M & L 6 mm thick veneered decorative plywoode ,grade 1 (with BWR resin) with decorative face veneers on one faces,in wall fixed with screws to timber frame work complete all as specified and directed by Engineer-in-charge.
M & L 6 mm thick veneered decorative plywoode ,grade 1 (with BWR resin) with decorative face veneers on one faces,in ceiling, flat or sloping fixed with screws to timber frame workcomplete all as specified and directed by Engineer-in-charge.
M&L plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails not exc 3 sqcm in section complete all as specified and directed by Engineer-in-charge.
M&L in repairs plain fillets square rectangular or triangular in section using 2nd class soft wood clean swan secured with nails exc 3 but not exc 6 sqcm in section complete all as specified and directed by Engineer-in-charge.
S&F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer-in-charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engineer-in-charge.
S&F Sheet glass thickness 3.00 mm,ordinary quality and glazing with oil putty in square exceed 0.5 sqm in each pane complete all as specified and directed by Engineer-in-charge.
S&F 2nd class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engineer-in-charge.
S&F to chowkat 2nd class soft wood glazed and skeleton shutters 35 mm thick , open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc. sizes of me-mbers of shutters complete all as specified and directed by Engineer-in-charge.
S&F 2nd class softwood Glazed and skeleton shutters thickness 30 mm,(, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters supplied and fitted to chowkats if windows, ventilators, etc. are provided with stiles and rails complete all as specified and directed by Engineer-in-charge.
S&F Aluminium anodised, barrel tower bolts 100 mm of extruded section complete all as specified and directed by Engineer-in-charge.
Aluminium anodised, barrel tower bolts 200 mm of extruded section complete all as specified and directed by Engineer-in-charge.
S&F Aluminium alloy, anodised, sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed by Engineer-in-charge.
S&F Aluminium alloy, anodised, sliding door bolt 200 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed by Engineer-in-charge.
S&F M S Butt hinges 100 mm medium weight, cold rolled mild steel, complete all as specified and directed by Engineer-in-charge.
S&F M S Butt hinges 75 mm medium weight, cold rolled mild steel,complete all as specified and directed by Engineer-in-charge.
S&F Aluminium handles 100 mm , cast type,anodised complete all as specified and directed by Engineer-in-charge.
S&F Aluminium handles 150 mm , cast type,anodised complete all as specified and directed by Engineer-in-charge.
S &F in repair curtain rod, mild steel, chromium plated fixed with stainless steel brackets and funnels stops, rollers etc complete all as specified and directed by Engineer-in-charge.
M&L Preparation of new wooden surface of any description and applying over a coat of primer, two coat of synthetic enamel paint, not otherwise descri-bed,over 10cm width or girth complete all as specified and directed by Engineer-in-charge.
M&L Preparation of old wooden surface of any description and applying a coat synthetic enamel paint, not otherwise descri-bed,over 10cm width or girth complete all as specified and directed by Engineer-in-charge.
S&F 2nd class softwood in scantling clean swan and fixed in any position to replace old and decayed timber complete all as specified and directed by Engineer-in-charge.
M&LChequered cement concrete tiles coloured (vibrator made) 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over 15 mm thick screed bed in CM (1:4) finished with cloured cement to match the shade of the slab complete all as specified and directed by Engineer-in-charge.
S&F in repairs 20 mm Wire netting of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staples complete all as specified and directed by Engineer-in-charge.
M&L Walling of random rubble,uncoursed as built in CM (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for Walling of random rubble ,uncoursed as built in CM (1:6) but except stone complete all as specified and directed by Engineer-in-charge.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-charge.
Dismantling water tanks and S&F 500 ltrs capacity ,Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engineer-in-charge.
S&F in repairs 20 mm Ball brass valves, high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs Stop/angle valves 20 mm, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated complete all as specified and directed by Engineer-in-charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed by Engineer-in-charge.
M&L 50 mm thickness Cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in finished the surface even and fair to receive the top layer complete all as specified and directed by Engineer-in-charge.
M&L 75 mm thickness Cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection finished even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-charge.
M&L Providing Coping , cement concrete 40 mm thick type C1 1:3:6 20 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer-in-charge.
M&L Cement concrete 75 mm thik type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection finished even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-charge.
M & L 6 mm thickness Plywood, grade BWR, type BB, fixed with screws to timber frame work in ceiling complete all as specified and directed by Engineer-in-charge.
M & L 6 mm thickness Plywood, grade BWR, type BB, fixed with screws to timber frame work in wall complete all as specified and directed by Engineer-in-charge.
Plain, framed, second class soft wood panelled shutters 35 mm thickness (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board withcommercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engineer-in-charge.
M&L Creosote preparing surfaces of wood and wood based materials, and wood based materials, new or old, of any description and girth, not otherwise described and treated with complete all as specified and directed by Engineer-in-charge.
Dismantling timber scantling under 40 Sqcm in section ,raills, posts,rafters,purlins,etc unframed work complete all as specified and directed by Engineer-in-charge.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:6)complete all as specified and directed by Engineer-in-charge.
S&F 2nd class softwood in scantling clean swan timber framed and fixed to the position to replace old and decayed timber complete all as specified and directed by Engineer-in-charge.
S&F 19 mm Prelaminated prticle board exterior grade, prelaminated both side with decorative choice lamination and other side balancing white lamination fiexed with aluminum beading to timber Aluminium frame work complete all as specified and directed by Engineer-in-charge.
S&F Anodised aluminium frame for partiton wall with one or more rebates incl joining cleat aluminium beading, rubber packing incl fixing bolt, design and pattern as apporval by Engr-in-charge complete all as specified.
S&F 8 mm Toughned glass ,best quality fixed with aluminium beading, rubber packing to aluminum frame as directed complete all as specified and directed by Engineer-in-charge.
S&F Factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-charge.
RCC type B1 1:2:4 (20 mm graded aggregate ) Beams cantilivers,shelves bressumers lintels over 1.5m span complete incl all necessary foam work complete all as specified and directed by Engineer-in-charge.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-charge.
S&F Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. . & drawing
Taking down shutter and refixing in the same opening of any description exc 1 sqm and n exc 2 sqm incl necessary, cutting and repairas directed by Engr-in-charge.
M&L for preparation of old surfaces of walls and applying one coats of white wash complete all as specified as directed by engr-in-charge.
Excavation in post holes (or similar holes) each not exc. 0.50 cum, in any type of soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25cm, watering and removal of excavated materials to a distance n. exc. 50m and making good surfaces, complete all as specified & directed.
M&L PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in foundations, filling, mass concrete and sub base of floor, complete all as specified & directed. .
S&F Dupravated Chequered cement concrete tiles, machine pressed, factory made of size 30cmx30cm, 10mm thick, with grey cement and no pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified as directed by engr-in-charge.
S&F Pre-painted galvatume aluminum zinc coating GI based profile steel sheet 0.60mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified as directed by engr-in-charge.
S&F Pre-painted galvalume aluminum zinc coating GI based profile steel sheet 0.60mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws,complete all as specified as directed by engr-in-charge.
S&F Rolled mild steel work in roof trusses (framed) trussed, medium class including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to I.S. 1161etc.I. S.1161-1979 grade St.-240 complete all as specified as directed by engr-in-charge.
Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.(a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way
(b) One 3 pin 5 Amp switch socket outlet on independent board
(c) One 3 pin 5 Amp switch socket outlet on same board with accessories
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor complete all as specified as directed by engr-in-charge.
S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified as directed by engr-in-charge.
S&F switch piano Flush type, single pole, 15 amp 240 volts,complete all as specified as directed by engr-in-charge.
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified as directed by engr-in-charge.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified as directed by engr-in-charge.
S&F step type fan regulator ,120 W, 1/2 modulecomplete all as specified as directed by engr-in-charge.
Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body all as specified and directed
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed
S&FDistribution Board, TPN, 4 Way, Double door complete all as specified and directed
S&F in repairs Distribution Board, SPN 8 Way, Single door complete all as specified and as directed
S&F in repairs Distribution Board, SPN 4 Way, Single door complete all as specified and as directed
S & F in repairs MCB, TPN 40 Amps 415 Volts C curve, complete all as specified and as directed
S & F in repairs MCB,SPN 40 Amps 240 Volts B curve, complete all as specified and as directed
S & F MCB Single pole 6-32A Amps 240 Volts B Curve complete all as specified and directed
S&F exhaust fan, steel body AC single Phase. 230V of size 380mm sweep with, blades, and frame and louvers, with making hole of suitable size and making good to the disturbed area complete all as specified and as specified and as directed.
S&F exhaust fan/brisk air fan of size 300 mm sweep, non matallic complete all as specified and as specified and as directed.
Supply and fix LED Lamp 10 W complete all as specified as directed by engr-in-charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose all as specified and directed
S & F LED light fitting 1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed
Taking down and dismantling the ceiling fan from site and removing its allied smaller parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers complete including, flexible chord of 24 / 0.20mm with necessary connector (for blade / body) as required after rewinding complete all as specified and directed.
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
Supply ,Laying ,connecting/ Jointing,charging, testing and commissioning LT cable electric, XLPE insulated, armoured, PVC sheathed, heavy duty, electric cable 1100 Volt grade with stranded aluminum conductor conforming to IS :7098, laid in trenches/ducts/fixed to wall /roofs/ poles all as specified of size 4 Core 16 sq mm . including Taking out old unservicable cable from any space
All as item No 117 but for 2 Core 16 sqmm
All as item No 117 but for 2 Core 10 sqmm
Excavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 mtr deep in depth for laying of cable and foundation of poles, stays and getting out in any type of soil complete all as specified and directed.
Removing surplus excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point all as directed.
Returning, filling in, excavated soil including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick all as directed.
M&L for sand cushioning in trenches for cable protection including consolidation complete all as directed.
M&L for Sub class "B" bricks laid dry width wise across the line of cable in treanchs as cable protection complete all as specified and directed.
M&L for boring/cutting road suitable for inserting GI Pipe 40mm light grade with making good to be disturbed surface with PCC 1:4:6 all as specified and directed
S&F GI Tubing light grade 40mm dia with all fitting; laid in trenches all as specified and directed
M/S MANZOOR AHMAD YATOO
M/S ALTAF HUSSAIN KHUROO
Javeed And Co
M/S ABDUL MAJID LONE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .