Loading…
Loading…
Tender Value
₹2.8 Cr
EMD Value
₹5.7 L
Closing Date
11 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. Meaning of Similar nature of work : "Any Signalling Work OR Any Telecom Work".
38 conditions · 31 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. Meaning of Similar nature of work : "Any Signalling Work OR Any Telecom Work"
S&T works for Replacement of multiple span bridges by RCC box bridge in DNA- MTD-SWF, FL- DNA, MTD- BKN & MKN- PBC sections over Ju Division
SNT-JU-23-2026-27~NWR
SNT-JU-23-2026-27
Open
Works - General
12 Months
Jodhpur, Rajasthan
₹0
₹5.7 L
18 Aug 2026
18 Aug 2026
28 Aug 2026
34 items across 1 schedule · ₹2,68,73,401.96 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| Supply of ARA Terminal Block (M-6) made of PBT/Poly Carbonate as per RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest and RDSO Drg. No. SA-23741A (Alt. 4) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | Numbers | 5420.00 | 105.2 | 5,70,184 | |
| 2 | Supply of Cartridge Fuse Block made of PBT and as per RDSO Drg. No. SA-23748 (Alt. 4) or latest and RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | Numbers | 3020.00 | 184.11 | 5,56,012.2 |
| 3 | 0.6 A | Numbers | 2300.00 | 73.55 | 1,69,165 |
| 4 | 1.6 A | Numbers | 2300.00 | 77.52 | 1,78,296 |
| 5 | Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution | Per Conductor | 2800.00 | 10.18 | 28,504 |
| 6 | Supply of Track Lead Junction Box (TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe, cable etc. (b) Each TLJB shall have two Bakelite terminal block fitted horizontally: each Bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Along with each TLJB, nickel chrome plated brass links (two nos.0f adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe of size 32/35mm, 380 mm long alongwith two nuts for fixing on the TLJB hole. (d) The FRP stump for mounting the TLJB to be made of one-meter long 30mm X30mmX 4mm angle (2 nos.) and 300mm long 30mm X30mmX 4mm angle (1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied alongwith TLJB drawing no. 11509. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers | 200.00 | 2,140.3 | 4,28,060 |
| 7 | Supply of UL standard PPTC fuses complies to UL Thermistor standard 1434 with rating- 2/4 Amps. Capacity wise distribution will be decided by Consignee. Inspection: Consignee. Inspection Charges: None. Payment Terms: 100% after supply. | Numbers | 4600.00 | 50 | 2,30,000 |
| 8 | Supply of Apparatus Case Single (Large) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board. (ii) Consignee if value of whole item in work less than 10 lakhs or as per extant instructions by Railway Board. Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers | 76.00 | 17,986.94 | 13,67,007.44 |
| 9 | Installation of Apparatus Cases Single (Large) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of lamp holder, switch and lamp etc. in Apparatus Case. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | Numbers | 76.00 | 1,250.54 | 95,041.04 |
| 10 | Supply of Apparatus Case half (Medium) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11507. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board. (ii) Consignee if value of whole item in work less than 10 lakhs or as per extant instructions by Railway Board. Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers | 18.00 | 11,360.32 | 2,04,485.76 |
| 11 | Installation of Apparatus Cases Half (Medium) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of Location lamp holder, switch and lamp etc. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | Numbers | 18.00 | 761.56 | 13,708.08 |
| 12 | Single (Large) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | Numbers | 76.00 | 8,290.81 | 6,30,101.56 |
| 13 | Half (Medium) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | Numbers | 18.00 | 6,329.4 | 1,13,929.2 |
| 14 | Supply of Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 20 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board. (ii) Consignee Inspection Charges:(i) Borne by Railways(ii) None Payment Terms: 100% after Supply. | Numbers | 89.00 | 11,509.62 | 10,24,356.18 |
| 15 | Single Case (Large Case) | Numbers | 76.00 | 2,821.59 | 2,14,440.84 |
| 16 | Half Case (Medium Case) | Numbers | 18.00 | 823.19 | 14,817.42 |
| 17 | Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. (Supply of all above terminals have been covered separately in Chapter 4 of SOR) Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | Numbers | 4620.00 | 15.07 | 69,623.4 |
| 18 | Supply of Medium class GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 with coupling on culverts bridges as per Drg. No. CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | Metre | 2130.00 | 915.45 | 19,49,908.5 |
| 19 | Fixing of Medium class GI pipes 100 mm dia(4.5 mm thickness) as per IS 1239 (Part 1): 2004 with coupling on culverts bridges as per Drg. No. CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work (if required) to protect the cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | Metre | 2130.00 | 228.87 | 4,87,493.1 |
| 20 | Supply of Double Walled Corrugated (DWC) HDPE Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer Dia & 103.5 mm inner dia . (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber O-Ring 2) Spacers3) Tees4) Bend,5) End-cap(The total quantity of above items is equal to no. of pipes supplied.)DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs or as per extant policy (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs or as per extant policy Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% after Supply | Numbers | 1040.00 | 2,164.13 | 22,50,695.2 |
| 21 | Supply of Double Wall Corrugated (DWC)- HDPE pipe/duct of size 200 mm outer Dia, & 175 mm inner dia. It includes supply of Double Wall Corrugated -HDPE pipe/duct as per RDSO Spec. No. RDSO/SPN/ 204/2011 (version 1.1) or latest and conforming to ISI Spec. No.IS:14930, Part- II. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber O-Ring 2) Spacers3) Tees4) Bend,5) End-capDWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs or as per extant policy (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs or as per extant policy Inspection Charges: (i)Borne by Railways(ii) None Payment Terms: 100% after Supply | Metre | 2160.00 | 461.51 | 9,96,861.6 |
| 22 | Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 With latest Amd. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply | Numbers | 225.00 | 2,586 | 5,81,850 |
| 23 | Jointing of 4 / 6 quad /Signalling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | Numbers | 152.00 | 1,392.99 | 2,11,734.48 |
| 24 | Horizontal direction drilling/boring without damage of surface road /track using Auger Machine (HDD machine) or by Closed trench Method. The bore shall be upto 200 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This includes insertion of different Dia DWC- HDPE pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note: - Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | Metre | 3200.00 | 1,447.77 | 46,32,864 |
| 25 | Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Western Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. (cum is Cubic Meter) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | cum | 6600.00 | 330.1 | 21,78,660 |
| 26 | Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | Running Metre | 29900.00 | 10.95 | 3,27,405 |
| 27 | Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor. (cum is Cubic Meter) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | cum | 19.00 | 2,395.61 | 45,516.59 |
| 28 | Supply and Installation of earth electrode including MS flat for signalling equipments on lever frame, apparatus cases, signal, relay racks, cable termination rack, block instrument etc. (supply & installation of earth electrode as per drawing no. RE/S&T/DRG/Tender/SK/398/94 for apparatus cases, signal post & other equipments as per instruction on earthing of S&T equipment. Laying of earth lead mild steel flat of size 35mmx6mm and fixing of lead MS flat to earth electrode and lever frame, signal post & apparatus cases as per Drg. No. CORE/S&T/ALD/SK/591/2008, 592/2008 and 593/2008 respectively and instructions on earthing at S&T equipment and providing cement enclosure for earth electrode as per drawing no. RE/S&T/Sig./Tender/SK/13/85 Alt. A) Note: This item requires for earthing of all the A/Cases & Signal as per RE standard. Inspection: Consignee Inspection charges: None Payment terms: 70% after supply, 20% after installation & 10% after commissioning | Numbers | 94.00 | 8,199.86 | 7,70,786.84 |
| 29 | Full Case | Numbers | 76.00 | 143.82 | 10,930.32 |
| 30 | Half Case | Numbers | 18.00 | 98.61 | 1,774.98 |
| 31 | Skilled man power to be provided by contractor for Engg/JCBs works, to provide marking & supervisory work for the S&T cables during digging work and repairing /restoring/jointing of cables, if damaged. Cables & Joints Material will be provided by railway. While Chuna marking will be done by his/her. Chuna will be provided by contractor. Information for deputing skilled man power for above work will be provided by Railway Engineer incharge before 24 hours from commencement of digging by JCBs. They will check cables route by Cable route tracer and will do chuna marking and will show the cables (on rough sketch). Note: Minimum two man will be provided at a time including Cable jointer, they will stay whole time during JCB digging work. (The CV to be got approved by Railway). | Man-Days | 2400.00 | 707.28 | 16,97,472 |
| 32 | Supply, preparation, splicing and installation of straight joint for 48 fibers along with enclosures with heat shrinkable splice protection sleeve as per TEC Specn. TEC 87080:2025 or latest. Splice losses in no case should be more than 0.1 dB. Inspection: Consignee Charges: None. Payment Terms: 100% after execution. | Numbers | 224.00 | 14,871.17 | 33,31,142.08 |
| 33 | Blowing/drawing of OFC cables in the HDPE duct along with all the protective work as per instructions of engineer incharge at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | Kilometre | 5.50 | 13,003.54 | 71,519.47 |
| 34 | Construction of Brick Chamber/RCC of optical fibre cable straight through joint as per Drg. No. CSTE/NWR/ SOR/23. It also includes supply and provision of all the material required for this item like bricks, sand, cement etc. The cement and sand should be in ratio 1:6. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | Numbers | 224.00 | 6,335.07 | 14,19,055.68 |
| Schedule total | ₹2,68,73,401.96 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
AdvancecorrectionsliptoGCC2022.pdf
ATTACHMENT
2022_12_13RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril2022ACSNo_2.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_3ACS-311.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_4ACS-4.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_8ACS-8.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_9ACS-9.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_10ACS-10.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_11ACS.pdf
ATTACHMENT
SNT-JU-23-2026-27TenderDocument.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].