Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹6.4 L+₹48,891 (8.22%)Rejected-AOC | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹8.5 L+₹2.6 L (43.0%)Rejected-AOC | L3 | Rejected-AOC L3 bidder |
Tender Value
₹9.5 L
EMD Value
₹10,000
Closing Date
14 Feb 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC I, Lucknow
Pareshan Bhawan, Vibhuti Khand, Gomti Nagar, Lucknow
Work of increasing capacity and associated works at 132KV Nindura under ETD III, Lucknow
2022_UPTCL_674295_1
e-tender 98/2021-22
Open Tender
Electrical Works
Piece-work
30 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No 2408002190005438, IFS PUNB0691100, PNB, Lko
₹10,000
13 May 2022
11 Jan 2022
15 Feb 2022
11 Jan 2022
14 Feb 2022
11 Jan 2022
180 days
Amount
Following works are to be carried out at 132/33 KV S/S Nindura for adding 1 No. 132/33 KV 40 MVA T/F and construction of 132 & 33 KV Side Bays of 40 MVA T/F, 01 No. 33 KV TBC Bay, Extension of 132 KV & 33 KV Main Bus & Transfer Bus including erection of main & auxiliary structure, equipments, C&R Panel, laying & termination of Control Cable with other associated works with all cost of men, T&P, misc. conusmbales etc. for satisfactory completion of the work.
Erection of following structures / equipments including their shifting from storage place to erection site with all other assoicated works as per technical specification:
Lattice type Main & Auxiliary Structure
145 KV SF6 Circuit Breaker
36 KV SF6 / Vacuum Circuit Breaker
145 KV Current Transformers
145 KV C.T. Junction Box
145 KV P.T. Junction Box
36 KV Current Transformer
36 KV CT Junction Box
36 KV PT Junction Box
145 KV Bus Isolator with Post Insulators (Motorized)
145 KV Tandem Isolator with Post Insulator (Motorized)
145 KV Post Insulators for support
36 KV Bus isolators with Post Insulator
Simplex type Transformer Control & Relay Panel for 40 MVA T/F
ABT Meter cubical
Cutting, straightening, laying 1500 mm below inside ground & above ground of 40 mm MS Round Bar to be provided by department as per requirement for earthing of Aux. Structures, Equipments & Cable Trenches including welding with 1 to 1 earthmat and with the object to be earthed, excavation of Trenches, its back filling including all other assoicated works to complete the Earthing work satisfactorily, as per tehcnical specification:
40 mm MS Round
40 mm MS Electrode
Cutting, straightening, laying 700 mm below inside ground & above ground of 75 mm x 10 mm, 50 mm x 6 mm & 25 mm x 5 mm size M.S. Flats to be provided by department as per requirement for earthing of Aux. Structures, Equipments, C&R Panel & Cable Trenches including welding with main earthmat and with the object to be earthed, excavation of Trenches, its back filling. Painting of Earthmat above ground level in Bus Green colour including all other assoicated works to complete the Earthing work satisfactorily, as per tehcnical specification:
Earthing of equipment with 120 KV LA with 75x10 mm size M.S. Flat.
Earthing of Main & Aux. Structures and Equipments with 50 mm x 6 mm
Earthing of Main & Aux. Structures and Equipments with 25 mm x 6 mm
Earthing of Cable Tranches with 25 mm x 5 mm
Fabrication of 3 Meter Long Electrodes with 40 MM dia M.S Rod having 150 mm long conical shape and then piercing them vertically in the ground with top 500 mm below ground level connecting 3 nos. electrodes with 75 x 10 mm Size M.S. Flats for formation of Shielding Mesh for LAs and finally connecting the delta with Main Earth mat at 2 places , with due digging of earth Trench its back filling and painting etc. with other associated works for satisfactory completion of the job as per Technical Specification. M.S. Rods for Electrodes and M.S. Flats shall be provided by department (1 job for each Delta )
Shielding Mesh For 132 KV LA
Shielding Mesh For 33 KV LA
Stringing of 132 KV 3 Phase Main Bus with help of 1x ACSR Moose Conductor with the help of required Insulators and Tension Fitting with all other associated works for satisfactory completion of the job as per technical specifications. (Section 36 Mtr.)
Stringing of 132 KV 3 Phase Jack Bus with help of 1x ACSR Panther Conductor for 132/33 KV 40 MVA T/F Bay with the help of required Insulators and Tension Fitting with all other associated works for satisfactory completion of the job as per technical specifications.
Stringing of 132 KV 3 Phase Transfer Bus with help of 1x ACSR Panther Conductor with the help of required Insulators and Tension Fitting with all other associated works for satisfactory completion of the job as per technical specifications. (Section 36 Mtr.)
Stringing of 33 KV 3 Phase Main Bus with help of 1x ACSR Moose Conductor with the help of required Insulators and Tension Fitting across Transformer Track Path, with all other associated works for satisfactory completion of the job as per technical specifications. (Section 24 Mtr.)
Stringing of 33 KV 3 Phase Transfer Bus with help of 1x ACSR Panther Conductor with the help of required Insulators and Tension Fitting across Transformer Track Path, with all other associated works for satisfactory completion of the job as per technical specifications.
Interconnecting of Equipments Between 132 KV Transfer Bus Bars to Main 132 KV Bus Bar Including cutting & bending of ACSR Panther Conductor and Jumpering & Clamping etc., with all other associated works for satisfactory completion of the job as per technical specifications And as per details below.
132/33 KV 40 MVA T/F 132 KV Side Bay (1 x Panther)
132/33 KV 40 MVA T/F 33 KV Side Bay (1 x Moose)
33 KV TBC Bay (1 x Panther)
Laying of control cables of following size as laid in the cable schedule in cable Trenches from TBC control Panel to 132 KV SF6 C.B. in the switch yard along with saddling at every 750 mm Distance with M.S. Saddles of size 25 X 2 mm Carriage cable drums from stores to the laying side and shifting back to the store after completion of work, and all other associated works to complete the job. satisfactory.
2C X 2.5 MM SQ. Unarmoured
4C X 2.5 MM SQ. Unarmoured
6C X 2.5 MM SQ. Unarmoured
Termination of control cables From CB & BI to TBC C&R Panel laid as above as per cable schedule including making necessary holes in Gland plates providing cable glands of proper size and proper Ferruling on both ends of the each core of the cables, their termination and all other associated works to complete the job satisfactory as per technical specification .
132/33 KV 40 MVA T/F 132 KV Side Bay
132/33 KV 40 MVA T/F 33 KV Side Bay
33 KV TBC Bay
Periphery & Road Lighting:
Providing, erection & grouting of M.S. Round Pole of 'B' Class 9.0 Meter long M.S. Pipe (114.3 mm x 4.5 mm x 5.0 M+88.9 mm x 3.65 mm x 2.0 M + 76.1 mm x 3.25 mm x 2.0 M) with Base Plate by grouting of the same using C.C. mixture of ratio 1:4:8 with cement, coarse sand & 40 mm stone ballast in the size of 450 mm x 450 mm x 1900 mm Plinth and plastering of the same above ground including excavation, back filling, curing etc. including earthing of Pole with M.S. electrode.
Providing of Lighting Junction Box of size 200 mm x 200 mm x 150 mm made of 16 SWG M.S. B.P. Sheet & painted with Smoke Grey colour synthetic enamel Paint duly fitted with 1 No. 6 Amp. S.P. M.C.B. on Anodised M.S. Channel, 1 No. Bakelite Fuse Fitting with 6 Amp. capacity NS 6 type HRC Fuse, 1 No. Copper Neutral Link, Bakelite terminal strip of 4 Nos. Terminals, Cable Glands suitable for 2C / 4C x 2.5 Sq. mm size incoming / outgoing Control Cables etc. & fixing on the Round Poles at designated height with the help of suitable duly fabricated M.S. Bracket Clamps and due earthing of the Junction Box including Cable Terminations.
Providing & grouting of G.I. Pipe duly made of 35 mm dia. 'B' Class 2.5 M long pipe & bent at one end by quarter circle in 0.5 M through concreet plinth of M.S. Round Pole for safe entry of Cable in Junction Box duly installed on M.S. Round Pole.
Providing & fixing of G.I. Pole Bracket of 40 mm dia. 'B' Class 1.20 Meter long M.S. Pipe of (ID 35 mm & OD 40 mm) bent at angle of 300 for fixing of 125 / 110 Watt LED Lamp Fittings with the help of M.S. Bracket Clamps of suitable size for fixing on Round Poles.
Providing & fixing of 120 Watt LED Street Light Luminaries of PHILIPS / CROMPTON GREAVES / HAVELLS make in Single piece die cast Aluminium Alloy Housing with Pot Optics Reflector & Toughened Clear Glass Cover with Frame for Lamp Compartment including Cable Terminations.
Painting of M.S. Round Pole with one coat of Red Oxide Primer and two coat of Zinc Rich Aluminium Paint of 1st Quality of Asian / Nerolac / Burger.
Making 03 No. Strips of 50 mm width at the height of 450 mm from the Plinth with PO Red Colour in bottom & top and White Colour in middle on each M.S. Round Pole & making 150 mm dia. circle and writing the number of Pole in the circle.
M/s Abhinav Enterprises
HARE KRISHNA ENERGY PROJECTS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .