Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC 1 A 7 STREET NO 214 ACTION AREA 1C NEW TOWN KOLKATA 700 156 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700156 | L1 | Accepted-AOC OK | |
| 2 | L2₹8.2 L+₹22,251 (2.78%)Rejected-AOC P O DHAP DHAPI MALLICKPUR P S BARUIPUR 24PGS S PIN 743387 | 24 PARAGANAS SOUTH | WEST BENGAL | 743387 | L2 | Rejected-AOC OK | |
| 3 | L3₹8.4 L+₹34,954 (4.37%)Rejected-AOC BARASAT HOUSING ESTATE PH II P O NOAPARA KOLKATA 700 125 | 24 PARAGANAS NORTH | WEST BENGAL | 700125 | L3 | Rejected-AOC OK |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
28 Feb 2023, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineeer (E)
NKDA Administrative Building
Electrical Installation works for construction of pay and use toilet near Sukho Bristi at street no 921, AA-III, New Town Kolkata under NKDA
2023_NKDA_478689_3
NIeQ No. 67/EE-E/NKDA/2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Street no 921, AA-III, New Town Kolkata
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹16,000
22 Mar 2023
22 Feb 2023
3 Mar 2023
22 Feb 2023
28 Feb 2023
22 Feb 2023
Amount
Supply, Erection, Testing and commissioning of double door feeder pillar (With Suitable foundation) outdoor type, stand mounting, dust and vermin proof feeder pillar with IP-55 protection.The panel shall be made out of 14 SWG Cold Rolled Close Annealed (CRCA) Sheet Steel. Panel shall have 2 coat of zinc chromate primer and 2 coat of epoxy paint both inside and outside.Cable entry shall be at the bottom and through a detachable gland plate of minimum thickness 8mm . Feeder pillar shall have pad-locking arrangement.The dimensions of the panel shall be at least 600mm (L) X 200mm (B) x 800mm(H).FP Must comprise with a suitable danger board and foundation.[Main Feeder for toilet at Street No 852] Incomer: 125A FP 25KA/35KA MCCB as per GS(Make- L&T/Legrand/ABB/Havells) Bus bar:(4X25X5mm) Al Bus bar of 0.5m length as per PWD specifications. Outgoings: a) S & F 415V 63A FP 10KA & C Curve MCB on din rail-04 Nos. (Make:L&T/Siemens/ABB/Legrand/Standard)[For Toilet,2 Nos bus stop-01 No each,01 No Spare] INTERCONNECTION: Inter connections to be made same with a. 16 Sqmm single core stranded FR copper wire from Main bus bar of 415A to 125A Incomer MCCB. b. 10 Sqmm Single core stranded FR copper wires from Bus Bar to 63A Outgoing MCB.
Supply, Erection, Testing and commissioning of double door feeder pillar (With Suitable foundation) outdoor type, stand mounting, dust and vermin proof feeder pillar with IP-55 protection.The panel shall be made out of 14 SWG Cold Rolled Close Annealed (CRCA) Sheet Steel. Panel shall have 2 coat of zinc chromate primer and 2 coat of epoxy paint both inside and outside.Cable entry shall be at the bottom and through a detachable gland plate of minimum thickness 8mm . Feeder pillar shall have pad-locking arrangement.The dimensions of the panel shall be at least 4400mm (L) X 200mm (B) x 570mm(H).FP must iclude a suitable danger board and foundation.[Sub Feeder for toilet at Street No 921] Incomer: 63A FP 10KA MCB as per GS(Make- L&T/Legrand/ABB/Havells/Standard) including stud type 4way suitable connector. Outgoings: a) S & F 230V, 06- 32A SP 10KA & C Curve MCB on din rail-04 Nos (Make:L&T/Siemens/ABB/Legrand/Standard)[To feed SPNDB inside tiolet-02 Nos,Spare-02 Nos] b) S & F 415V, 32A 4P 10KA & C Curve MCB on din rail-01 No. (Make:L&T/Siemens/ABB/Legrand/Standard)[ToPump] INTERCONNECTION: Inter connections to be made same with a.10Sqmm single core stranded FR copper wire from Connector bar to 63A Incomer MCB.b. 6 Sqmm Single core FR copper wire from Connector bar to 32A Outgoing MCB.
Supply, Erection, Testing and commissioning of double door feeder pillar (With Suitable foundation) outdoor type, stand mounting, dust and vermin proof feeder pillar with IP-55 protection.The panel shall be made out of 14 SWG Cold Rolled Close Annealed (CRCA) Sheet Steel. Panel shall have 2 coat of zinc chromate primer and 2 coat of epoxy paint both inside and outside.Cable entry shall be at the bottom and through a detachable gland plate of minimum thickness 8mm . Feeder pillar shall have pad-locking arrangement.The dimensions of the panel shall be at least 440mm (L) X 200mm (B) x 570mm(H).FP mus be comprising with a danger board and foundation [Sub Feeder for Bus Stops at Street No 921] Incomer: 63A FP 10KA MCB as per GS(Make- L&T/Legrand/ABB/Havells/Standard) including stud type 4way suitable connector. Outgoings: a) S & F 230V, 40A SP 10KA & C Curve MCB on din rail-03 Nos. (Make:L&T/Siemens/ABB/Legrand/Standard)[To feed SPNDB inside Bus stop-01 No,Spare-02 Nos] b) S & F 230V, 32A SP 10KA & C Curve MCB on din rail-03 Nos. (Make:L&T/Siemens/ABB/Legrand/Standard)[To Signage-01 No,Spare-02 Nos] INTERCONNECTION: Inter connections to be made same with a.10Sqmm Single core stranded FR copper wire from Connector bar to 63A Incomer MCB. b. 6Sqmm Single core FR copper wire from Connector bar to 32A Outgoing MCB.
Supply and installation of 1.8 Mtr GI Spike[ Feeder Pillar Earthing]
Supplying and fixing 6 Way double-door SPN MCB Distribution Board with 40A DP Isolator as incomer-01No,6-32A SPCB as outgoings-06 Nos. IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.[All make:Legrand/L&T/Havells/Standard][Toilet-02 Nos,Bus Stop-02 Nos]
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed][Avg run 9 mtr]
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLS-H' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Legrend-Myrius) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.(On Board Plug)
Supplying and fixing 25 mm PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required necessary connection.[Make:Legrand/L&T/ABB/Havells] a) 3 x 22/0.3 (1.5 sqmm)[On Board]
b) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC[20A PP]
c) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC[FP to SPNDB]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works[6 Module][Bus Stop]
Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works[2 Module][Kitchen at Bus stop]
Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
S&F of 9" heavy duty exhaust fan with louver Shutter[Make:Cromton/EPC/Orient]
S&F of 24 W LED batten on surface/metal pipe] [Make:Crompton/Philips/Havells/Magik]
S&F 09 Watt LED Tube with angular holder on wall[Make:Crompton/Philips/Havells/Magik]
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set.
S&F of 230V,400 mm Wall mounted fan [Bus stop kitchen]
S&F of 230V,10-12 W recessed light fitting[Havells/Crompton/Philips/Magik]
Supply and delivery of 1.1KV Grade PVC/XLPE Insulated 4C 16 Sqmm Al Ar cable[Make:Havells/Polycab/Gloster]
Microtunneling with Supply of 50mm Dia HDPE Pipe
Laying of 4C 16 Sqmm Al Ar cable through microtunneling
S&F of compression type brass gland and finishing ends as per GS.[For 4C 16 Sqmm Al Ar Cable]
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. a) 2.5Sqmm
b) 4 Sqmm
c) 6 Sqmm
PUSPA ELECTRIC
D.B ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .