Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC MAHAMUNI PARA BOGAFA P S P O SANTIRBAZAR SOUTH TRIPURA | GOMATI | TRIPURA | 799125 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹49.9 L+₹3.7 L (8.01%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹77.2 L+₹31.0 L (67.2%)Rejected-Finance 15 401 PREM JOT COMPLEX ANIKET CO OP HSG SOC LTD NEAR INDIAN OIL NAGAR GHATKOPAR MANKHURD LINK ROAD GOVANDI CHEMBUR W MUMBAI 400043 | MUMBAI | MUMBAI | MAHARASHTRA | 400043 | L3 | Rejected-Finance Being L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not meeting eligibility criteria |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
12 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR/MAINT OF LT DISTRIBUTION SYSTEM AND REPLACEMENT OF LT UG CABLES AT DARJIPURA AREA AT AF STN BARODA
2021_MES_430815_1
8611/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹94,000
Yes
19 Jun 2021
15 Mar 2021
14 Apr 2021
15 Mar 2021
12 Apr 2021
30 Mar 2021
17 Mar 2021 - 20 Mar 2021
60 days
Amount
M&L for repair and rectification of complaints on external LT electric supply 1100 Volts grade, over head/underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
Replacement of worn out jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
Disconnecting LT UG cable from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately under respective items. (ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes.
Repair of faulty LT switch gear/Main Switch of any type and size fixed in panel board/pole mounted boxes on walls or any other indicated places including replacement of lugs/thimbles of suitable sizes. Note :- Lugs if any required to be replaced shall be measured under respective item of schedule.
Supply, install, testing and commissioning in repair weather and vermin proof LT feedar pillar bus bar junction box (Panel board) factory fabricated (CPRI approved) Outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 60cm X 50 cm X 60 cm suitable for operation on 3 phase 4 wire, 440 volts, 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of suffiecient Numbers of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required Number of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat including connecting with L.T armoured incoming and outgoing cables and including required sizes of cable lugs of aluminium complete all as specified and directed by Engineer- in -charge( as per sample )and consisiting of following :-
(a) Bus bars of Aluminium strips of 400 Amp current rating capacity, minimum 600 mm long or of length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulator complete with CTs of suitable size with nut bolt fixing arrangement complete - 01 set
M&L for ACSR conductor, steel reinforced for LT over head lines on poles including streching, tightining to pole insulator with binding wire of suitable size including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed.
M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
M&L for Shackle type, Porcelain, vitreous, white, brown or green insulator of size 100 mm height, 115 mm dia for 1100 Volt grade, including galvanised mild steel straps, insulator bolts, washers and nuts, section of straps 31x5 mm, including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
S&F Stay assembly comprising of 7/10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, upto 50m including disconnecting/taking out old existing unsv stay assembly complete all as specified and directed.
S&F of Galvanised steel wire (GI) 4mm dia including disconnecting/taking out old existing unsv GI wire complete all as specified and directed.
M&L for cross arms, bracing, support clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/taking out old existing unsv cross arms complete all as specified and directed.
S&F Loadline MCCB (Conforming to IEC:60947-II/IS:13947-II) of capacity 400 Amps, 4 Pole, 36 KA, 415 Volt in exisitng LT Panel box/Feeder Pillar boxes (KIOSK), Adjustable thermal and fixed magnetic setting including disconnecting/taking out existing old unsv/burned MCCB complete all as specified and directed.
Description all as per item No-9 here in before but of capacity 250 Amps, 4 pole, 25 KA
Description all as per item No-9 here in before but of capacity 200 Amps, 4 pole, 25 KA
Description all as per item No-9 here in before but of capacity 160 Amps, 4 pole, 16 KA
Description all as per item No-9 here in before but of capacity 125 Amps, 4 pole, 16 KA
Description all as per item No-9 here in before but of capacity 100 Amps, 4 pole, 16 KA
Description all as per item No-9 here in before but of capacity 63 Amps, 4 pole, 16 KA
S&F MCB/Isolator, 100 Amps, 4 pole, 415 Volts with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.
Description all as per item No-16 here in befor but of capacity 63 Amps, 4 pole, 415 Volts with breaking capacity 10KA
Description all as per item No-16 here in befor but of capacity 40 Amps, 4 pole, 415 Volts with breaking capacity 10KA
S&F MCB, SP 6-32 Amps, 415 Volts with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned MCB complete all as specified and directed.
Supply and fixing surface mounting digital timer switch 240 Volts, 50 Hz, 16-32 Amps rating (For Street light/High Mast light) fitted inside steel enclosure complete all as specified and directed Make : L&T/ HAVELLS/Standard.
S&F Timelite distribution boards, Timelite-32A, 3 Pole/230V - Astronomical time switch along with suitable size of box made of sheet 2mm thick size 30x25x15 cm powder coated suitable for fixing at pole including two set of clamps comprising with the following :- (i) MCB TPN 32 Amps 10 KA - 01 No. (ii) Digital Timer suitable for 24 hours operation of street light (iii) Contctor two pole 40 Amps 415 Volt coil operating voltage 230 volt (iv) Auto manual switch 10 Amps, complete including all internal connection done by using suitabale size of copper wire complete all as specified and directed.
S&F in repairs contactor 3 phase 415 volts 50 Hz of ML-2, 32 Amp rating, coil voltage 420 volts, fitted inside steel enclosure complete all as specified and directed. Make : L&T /HAVELLS/Legrand/Indoasian/C&S.
S&F in repairs contactor 3 phase 415 volts 50 Hz of MNX 32 coil voltage 420 volts, fitted inside steel enclosure complete all as specified and directed. Make : L&T /HAVELLS/Legrand/Indoasian/C&S.
S&F in repairs contactor 3 phase 415 volts 50 Hz of MNX 40 coil voltage 420 volts, fitted inside steel enclosure complete all as specified and directed. Make : L&T /HAVELLS/Legrand/Indoasian/C&S.
Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for straight through joint with jointing material and accessories suitable for aluminium conductor cable of size 16 to 50 Sqmm, 3.5 Core complete all as specified and directed.
Descritption all as per item No 25 above but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core
Descritption all as per item No 25 above but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 185 Sqmm, 3.5 Core
Descritption all as per item No 25 above but suitable for aluminium conductor cable of size from 240 sqmm, 3.5 Core to 400 Sqmm, 3.5 Core
Supply, lay, commissioning and testing of cable jointing Kit for 11000V grade cable for outdoor End termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 16 to 35 Sqmm, complete all as specified and directed.
Descritption all as per item No 29 above but suitable for aluminium conductor cable of size from 50 sqmm 3 Core to 95 Sqmm 3 Core
Descritption all as per item No 29 above but suitable for aluminium conductor cable of size from 120 sqmm, 3 Core to 150 Sqmm, 3 Core
Descritption all as per item No 29 above but suitable for aluminium conductor cable of size from 185 sqmm, 3 Core to 400 Sqmm, 3 Core
Supply and lay cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, laid in trenches/duct or fixed to wall/passing through pipe on pole with and including suitable size cable glands, crimping type cable lugs for stranded aluminium conductor of the following sizes including disconnnecting/taking out existing unsv/damaged old LT UG cable complete all as specified and directed :- Notes : Excavation, Returning filling, Sand cushioning and brick protection shall be measured and paid separately under respective items.
2 core X 10 Sqmm
2 Core X 16 Sqmm
4 Core X 16 Sqmm
3.5 Core X 25 Sqmm
3.5 Core X 35 Sqmm
3.5 Core X 50 Sqmm
3.5 Core X 70 Sqmm
3.5 Core X 95 Sqmm
3.5 Core X 120 Sqmm
3.5 Core X 150 Sqmm
3.5 Core X 185 Sqmm
3.5 Core X 240 Sqmm
Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Restreching/Restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and prunning of tree complete all as specified and directed. Notes: (i) The distance between pole to pole is considered as one span (contains 2/4/6 runs) i.e one span will only be considered for payment purpose. (ii) No Extra conductor will be measured for binding to insulators / jumpering etc.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in Hard / Dense soil complete all as specified and directed.
Description all as per item No 36 above but depth exc 1.5 mtr but not exc 3 mtr.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) to a distance not exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling sand in trenches for sand cushioning of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, complete all as specified and directed. Note :- Thickness of sand cushion after punning down (i.e 18 cm) shall be measured for payment.
Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as directed
M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as directed
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as directed
Cutting the existing road/PCC surface straight by manual, depth and width not more than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
M&L for making horizontal holes below road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by hydraulic pipe jacking technique complete including tunneling in any type of soils including hard rock, including MS casing pipe havy duty of size 100 mm dia with 6 mm thick in any length including jointing materials for passing of LT UG cables of any size and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed. Note: Quoted rate is deemed to include for provison of 100mm dia MS casing pipe.
M&L for replacement of broken of PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate, and 40mm thick earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
M&L for repair/maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed.
M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with one coats of aluminium paint including throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos blue and 2 Nos white) from ground/plinth level, complete all as specified and directed.
M&L for Painting the existing LT PCC poles with one coat of synthetic enamel base paint including painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 blue and 2 white) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level, with top edge of plate not less than 1.5m below ground level, connecting to the Galvanized iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanized iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- Item of earthing includes cost of 7.5m long galvanized iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. (ii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering, stringing the ACSR conductor, Fuse wire etc, if damaged during triming of branches.
Cutting unaxious green growth and grass by manual labour or by machine at all 11 KV Electric Installation premisses/around 2/4 Pole structure/along the boundary fencing and removing rubbish from the site of work complete all as specified and directed.
S&F new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10 KV Built-in-Surge Protection Device, road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. Make : Cat Part No PCGLS C4 90W of make polycab, Cat Part No HLSLD-09-90-CW of make Halonix, Cat Part No LSFS-090-C of make orient. Note for item No 54 to 59 : (i) Contractor has to produce LM-79/LM-80 certificate alongwith purchase vouchers. (ii) Surge protection of the drive should be 10 KV
Description all as per item No-54 above but of capacity 72 watts. Make : Cat Part No PCGLS C4 72W of make polycab, Cat Part No HLSLD-09-72-CW of make Halonix, Cat Part No LSFS-070-C of make orient.
Description all as per item No-54 above but of capacity 60 watts. Make : Cat Part No PCGLS C4 60W of make polycab, Cat Part No HLSLD-09-60-CW of make Halonix, Cat Part No LSFS-060-C of make orient.
Description all as per item No-54 above but of capacity 45 watts. Make : Cat Part No PCGLS C4 45W of make polycab, Cat Part No HLSLD-09-45-CW of make Halonix, Cat Part No LSFS-045-C of make orient.
S&F Energy saving, environmental friendly long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 150 watts with suitable drivers, 10KV built in surge protection device etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole including taking down old unserviceable light fitting of any type and capacity complete all as specified and directed. Make :Cat part No JETAIRISFLS150WLED757PSYMLTG of make havells, Cat Part No PCGLF T1 01 150 57 of make polycab, Cat Part No HLFLD-ML01-150-CWL of make Halonix, Cat Part No LFAP-150--C of make orient or equivalent model in Philips/Wipro.
S&F New generation, post-top, energy saving, environmental friendly long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source of capacity 36 watts and all standard accessories etc fixed to main gate in any location and position complete all as specified and as directed. Make : Cat Part No PCGLP 01 40 0 of make polycab, Cat Part No HLPT-01-40-CW of make Halonix, Cat Part No LLOP-30-C of make orient.
Taking down old unsv Street light fittings in any position of any capacity, Repair of street light fittings by replacement of unsv spares and re-fixing the same in existing location. Note:- (i) Spares for repair of street light fittings will be measured and paid under respective items. (ii) However fixing element of supply only items is deemed to be included in the quoted rate of this item.
Supply only following spares for street light fittings:-
Supply only HPSV electronic choke 400W for flood light
Supply only HPSVIgnitor 400W for flood light
Supply only LED Driver suitable for upto 72 watts LED light fittings complete all as specified and directed. Make : Bajaj cat part No BGD 36 180 5Y or techno commercial equivalent model in Philips/Wipro/Havells.
Suppy only HPSV Lamp 400W for flood light.
Supply and fixing bracket for steel light fitiing made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified.
S&F PVC insulated unsheathed/sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/1990 with latest amendments ISI including disconnecting/taking out existing unsv/damaged old service cable complete all as specified and directed.
Description all as per item No 63 above but of size 6 Sqmm complete all as specified and directed.
S&F street light LT junction box out door type, with locking arrangements fixed on poles PVC Moulded of size 230x180x110 mm alongwith Bus Bar, 20 to 32 A MCB SPN - 01 Nos for connecting suitable size of XLPE UG cable testing and commissioning all as specified and directed.
Supply and laying GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm complete all as specified and directed.
Supply and laying GI tubing light grade of size 50 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm complete all as specified and directed.
Supply and laying GI tubing light grade of size 80 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm complete all as specified and directed.
S&F LT line rigid PVC Spacers spiral type, two lines, Phase to phase distance 300 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm complete all as specified and directed.
S&F LT line rigid PVC Spacers spiral type, three lines, Phase to phase distance 600 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm complete all as specified and directed.
S&F LT line rigid PVC Spacers spiral type, four lines, Phase to phase distance 900 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm complete all as specified and directed.
S&F in repairs On-Load changeover switch (In sheet steel enclosure), AC 21 (Side Handle), 4 pole of capacity 200 Amps, 415 Volts, 50 Hz, confirming to HSN Code : 8536 complete all as specified and directed.
S&F in repairs On-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 160 Amps, 415 Volts, 50 Hz, confirming to HSN Code : 8536 complete all as specified and directed.
S&F in repairs On-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 63 Amps, 415 Volts, 50 Hz, confirming to HSN Code : 8536 complete all as specified and directed.
Supply only of aluminium cable lugs of following sizes :-
16 Sqmm Size
25 Sqmm size
35 Sqmm size
50 Sqmm size
70 Sqmm size
95 Sqmm size
120 Sqmm size
150 Sqmm size
185 Sqmm size
240 to 400 Sqmm Make for ser item No 75.01 to 75.10: Dowells/Jaison.
Supply only of insulation tape roll for cable protection of following sizes :-
25 mm Size of 100 RM length
15 mm Size of 100 RM length
M&L for welding existing broken panel doors and fixing good quality hinges(any size any number of hinges per panel) of suitable size for making open and close the panel doors and fixing/welding angle/notch and Nut Bolts washers of suitable size to keep the door locked and including welding and making good any other broken portion of panel(double door also) complete all as specified and directed by Engr-In-Charge.
Suppl only copper wire 30 Sqmm multistranded for Panel board all as specified and directed by Engr-in-Charge
M& Labour for hiring of fault Locator Machine complete from the authorised supplier alongwith their team, finding out the exact LT fault location from both end termination of underground cable incl necessary excavation and earth work comlete all as secified and directed by engr-in-charge
SHREE KARNI LIGHT HOUSE
DARSHAN CONSTRUCTION Co.
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .