Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC 2ND FLOOR BLOCK B C 4 BALAJI HERITAGE SAKHIPADA SAMBALPUR ODISHA PIN 768001 | SAMBALPUR | SAMBALPUR | ODISHA | 768001 | L1 | Accepted-AOC TECHNO COMMERCIALLY ACCEPTED BID | |
| 2 | L2₹28.7 L+₹5.7 L (24.8%)Rejected-Finance AT BUDBIJAM PO ORIENT COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L2 | Rejected-Finance AS PER TC RECOMMENDATION | |
| 3 | L3₹25.4 L+₹2.4 L (10.5%)Rejected-Finance AT MAA SHAKTI NAGAR PRADHANPARA P O BUDHARAJA DISTT SAMBALPUR ODISHA | L3 | Rejected-Finance AS PER TC RECOMMENDATION |
Tender Value
₹39.7 L
EMD Value
₹49,700
Closing Date
15 Mar 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO E AND M
OFFICE OF SO E AND M BASUNDHARA AREA MCL
Erection, dismantling and modification of 6.6kV HT overhead line at Kulda OCP Basundhara Area
2024_MCL_302657_1
MCL/GM/ BA/EM/e-Proc/2023-24/27 Date- 25/02/2024
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
BASUNDHARA AREA
AS PER NIT AND TC
4 documents required · 4 mandatory
₹49,700
10 May 2024
26 Feb 2024
18 Mar 2024
26 Feb 2024
15 Mar 2024
27 Feb 2024
26 Feb 2024 - 1 Mar 2024
Amount
Erection of metallic pole of 8 to 10 Mtr. length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required
Erection of metallic pole of 10 to 12 Mtr. length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundationncluding excavation and refilling etc. as required.
Supplying of chhanel iron 75 mm X 40 mm X 6 mm (7.14 kg per meter ) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6 mm M.S. flat iron clamps, bolts, nuts and washers etc ( as per drawing ) and painting with primer and finish paint as required.
Supplying of chhanel iron 75 mm X 40 mm X 6 mm (7.14 kg per meter ) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mmX6 Angle iron Bracket welded to the channel iron & complete with 50 mm X 6 mm M.S. flat iron clamps, bolts & nuts including drilling holes for insulator pins,bolts, nuts and washers etc ( as per drawing ) and painting with primer and finish paint as required.
Supplying of chhanel iron 75 mm X 40 mm X 6 mm (7.14 kg per meter ) pole top bracket/ shape cross arm for single 11 KV over head line conductors complete with 50 mm X 6 mm M.S. flat iron clamps, bolts, nuts and washers etc ( as per drawing ) and painting with primer and finish paint as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron, cross arm on steel tubular/ rali/ PCC pole for 11KV/22KV/33KV as required.
Supplying of two length chhanel iron 75 mm X 40 mm X 6 mm (7.14 kg per meter ) double pole cross arm for three wire 11 KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the chhanel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fitting , bolts, nuts and washers etc ( as per drawing ) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of a set of cross bracing FRL same work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 6 mm angle iron to form a rectangle of minium size 1400 mm width X 2500 mm height, complete with 50 mm X 6 mm M.S flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc ( as per drawing ) and painting with primer and finish paint as required.
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including etc. as required.
Supply of G.I Wire 8 S.W.G.
Erection of G.I. Wire No. 8 S.W.G. including binding etc. as required.
Erection of cradle guard 55 mtr. Length
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required
Supply and fixing of Horizontal type Single break 11KV X 2 post insulator per., 200 amper G.O.A.B switch /isolator/disconnector/sectionalizer confirming to IS-9921/1985
Suply and fixing of horn Gap Fuse/Drop out fuse 11KV, 200 Amper 2 pin insulator per phase confirming to IS-93886/1988
Supply and fixing of Horingital type Double break 11KV X 3 post insulatorper phase 400 amper G.O.A.B switch /isolator/disconnector/ sectionalizer confirming to IS-9921/1985
Supply and fixing Horn Gap Fuse/Drop out Fuse 11KV , 400 Amper 2 post insulator per phase confirming to IS-93886/1988
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Dismantaling of pole/street light standard/strut embedded in cement concrete foundation etc. as required.
Dismantaling of over head lines comprising of copper/alluminium over head conductor,G.I. wire, cross arm, insulator etc. as required.
Transportation of Over head line matrial likepole,conductor etc. to the work site as per the direction of E.I.C.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
DO INFRA AND POWER PRIVATE LIMITED
M/s BIKASH ENTERPRISES
techsummary_313529.pdf
PDF • 1.88 MB
finsummary_313529.pdf
PDF • 1.88 MB
LOA27.pdf
PDF • 1.25 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .