Loading…
Loading…
Tender Value
₹431.3 Cr
EMD Value
₹4.3 Cr
Closing Date
29 Apr 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Additional Chief Engineer (Streetlight)
Tender for Comprehensive Operation and Maintenance contract of Street Light Poles, SITC of Street Light work at Eastern side and SITC and Implementation of Centralized Smart city Management System (CMS for streetlight) for entire Ahmedabad city for Five Years
296138
2026-2027
Open
Miscellaneous Works
Ahmedabad
3 documents required · 3 mandatory
₹18,000
Municipal commissioner, Ahmedabad
₹4.3 Cr
10 Apr 2026
10 Apr 2026
10 Apr 2026
29 Apr 2026
10 Apr 2026
Total Amount of 5 Years (SECTION-A)
Amount for 1st Year ( 1 month x 12 nos )
Amount for 2nd Year ( 1.03 x Amount of 1st Year )
Amount for 3rd Year ( 1.06 x Amount of 1st Year )
Amount for 4th Year ( 1.09 x Amount of 1st Year )
Amount for 5th Year ( 1.12 x Amount of 1st Year )
Total Amount of 5 Years (SECTION-B1)
Total Amount of 5 Years (SECTION-B1)
SECTION- B2 SITC Work
Amount of 1st Year
Amount of 2nd Year ( 1.03 x Amount of 1st Year )
Amount of 3rd Year ( 1.06 x Amount of 1st Year )
Amount of 4th Year ( 1.09 x Amount of 1st Year )
Amount of 5th Year ( 1.12 x Amount of 1st Year )
Total Amount of SITC Work (SECTION-B2)
Total Amount of SITC Work (SECTION-B2)
Total Amount of O & M (SECTION B1+ SECTION B2)
Total Amount of O & M (SECTION B1+ SECTION B2)
SECTION- C CMS and SFP Work
Implementation of City Management System ( for Street Light)
Section Feeder Pillar Work (Consider 50% New)
Section Feeder Pillar Upgradation Work (Consider Remaining 50% Upgradation Amount)
Total Amount of Section Feeder Pillar (SECTION-C)
Total Amount of Section Feeder Pillar (SECTION-C)
SECTION- D AI Work (Optional)
Total amount of AI Work (Section D) (Optional)
Total amount of AI Work (Section D) (Optional)
Document : Zone Wise pole qty detail
Project : Street Light Work Ahmedabad
Client : Ahmedabad Municipal Corporation
Sr NOS OF STREETLIGHT
5 Saijpur Bogha
8 Thakkarbapa Nagar
North Zone Total
3 Central Jamalpur
Central Zone Total
6 Ramol Hathijan
East Zone Total
South Zone Total
Grand Total ( Package A East Zone)
Grand Total ( Package A East Zone)
Document : SECTION-A, O & M WORK
Project : Street Light Work Ahmedabad
Client : Ahmedabad Municipal Corporation
DESCRIPTION UNIT
NO. QTY RATE TOTAL
Street Light pole with < = 30 w LED light fitting (With Single
Street Light pole with < = 30 w LED light fitting (With Two
Street Light pole with < = 30 w LED light fitting (With Three
Street Light pole with LED light fitting between 31w to 70 w
(With Single Arm)
Street Light pole with LED light fitting between 31w to 70 w
Street Light pole with LED light fitting between 31w to 70 w
(With Three Arm)
Street Light pole with LED light fitting between 31w to 70 w
(With Four Arm)
Street Light pole with LED light fitting between 71w to 135 w
& Above (With Single Arm)
Street Light pole with LED light fitting between 71w to 135 w
& Above (With Two Arm)
Street Light pole with LED light fitting between 71w to 135 w
& Above (With Three Arm)
Street Light pole with LED light fitting between 71w to 135 w
& Above (With Four Arm)
Street Light pole with SMART LED light fitting between 80w
to 250 w (Excluding LED Fixture, Driver, SPD, Smart
Controller, Over Voltage Protection Devices). (With Single
Street Light pole with SMART LED light fitting between 80w
13 to 250 w (Excluding LED Fixture, Driver, SPD, Smart No 588.00 105.00
Controller, Over Voltage Protection Devices) (With Two Arm)
Street Light pole with SMART LED light fitting between 80w
to 250 w (Excluding LED Fixture, Driver, SPD, Smart
Controller, Over Voltage Protection Devices) (With Three
Street Light pole with SMART LED light fitting between 80w
to 250 w (Including LED Fixture, Driver, SPD, Over Voltage
Protection Devices) (With Single Arm) (After guarantee
Street Light pole with SMART LED light fitting between 80w
to 250 w (Including LED Fixture, Driver, SPD, Over Voltage
Protection Devices) (With Two Arm) (After guarantee period
17 Ring Pole with Four Smart fitting No - 128.00 -
18 Ring Pole with Four fitting No - 128.00 -
19 High Mast Pole with LED fittings (12.0 mt to 30.0 mt High) No 161.00 1,801.00
High Mast Pole with Conventional (Sodium / MH) fittings
(12.0 mt to 30.0 mt High)
Monthly charges for the Provision of cellular / IoT data
connectivity for smart streetlight controllers and feeder-level
equipment, enabling real-time communication with the central
Document : SECTION-B1, OPTIONAL WORK FOR O&M
Project : Street Light Work Ahmedabad
Client : Ahmedabad Municipal Corporation
1 Section Feeder Panels
2 Cable Trench & Pipe
3 Cable & Termination
4 Street Light Pole & Bracket
Total Amount for 1 Year
Total Amount for 1 Year
Total Amount for 1 Month
Total Amount for 1 Month
ESTIMATE Page : 5 of
DESCRIPTION UNIT
NO. QTY RATE TOTAL
Note :It is mandatory for the successful bidder to execute this work as many times and for as much quantity as required,
based on the actual site conditions, throughout the entire contract period, as and when needed.
1 Section Feeder Pillar
Installation of Section Feeder Panel
Installation Testing and Comissioning of New / existing
section feeder pillar as said location by engineer in charge
complete in all respect as it is original with necessary cable
termination, with extra required various sizes cables & with
cable joints if needed etc. as per requirement or as per
instruction of engineer in charge.
Section Pillar Type-A, Each Door of Size Approx Height
1250mm, Length 450mm, 16 Guage
Section Pillar Type-B, Each Door of Size Approx Height
750mm, Length 375mm, 16 Guage
SITC of Section Pillar Stand of Size 40mm x 40mm x 6mm
angle, Height 950mm, Length 90mm, width 600mm.
Painting of Existing Section Feeder Panel Complete with two
coats of Aluminium Paint
1.6 Dismentalling of SFP no 275.00 1,108.00
1.7 Muffing of SFP no 225.00 4,209.00
Total of Section Feeder Pillar
2 Cable Trenches, Manholes & Pipes -
Making trench in soft soil of suitable width of 90 cms deep
from the final ground level or road level for laying cable or
locating the fault all over the run and backfilling the same &
clearing the site by removing debris & Shifting of the debris &
making site good As per the Instruction of the Engineer
Making trench in Hard murum / Tar Road of suitable width of
90 cms deep from the final ground level / road level for laying
cableor locating the fault all over the run and backfilling the
same and making the surface proper. by removing debris &
Shifting of the debris & making site good As per the
Instruction of the Engineer Incharge.
(B) If additional machinery like hammer driller or JCB use
Covering of cable with second class bricks laid cover the
cable crosswise & also on both sides with covering of 7.
Cms. layer of sand above & below cable (cable shall be laid
in 0.9mtr.deep & 0.4 Mtr.wide trench). Where there are more
than one cable in the trench on either side of the cable,
Cms. over lapping of bricks shall be provided.
Driling the road without breaking the road surface (Asphalt)
for laying of cable for feeding power supply by making
Suitable size of holes at both ends complete. (A) Up to
Driling the road without breaking the road surface (Asphalt)
for laying of cable for feeding power supply by making
2.6 Suitable size of holes at both ends complete. mt 800.00 610.00
(B) Up to 150 mm bore dia
Providing & laying. Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II ) Anti Rodent type
with necessary connecting accessories of same material at
required depth for laying of cable. below ground / road
surface for enclosing cable with Excavation and backfilling the
same to make ground as per original. (A)50 mm dia
ESTIMATE Page : 6 of
Providing & laying. Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II ) Anti Rodent type
with necessary connecting accessories of same material at
required depth for laying of cable. below ground / road
surface for enclosing cable with Excavation and backfilling the
same to make ground as per original. (C)90 mm dia
Providing & laying. Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II ) Anti Rodent type
with necessary connecting accessories of same material at
required depth for laying of cable. below ground / road
surface for enclosing cable with Excavation and backfilling the
same to make ground as per original. (D)120 mm dia.
Providing & laying approved make ISI marked HDPE 6Kg /
cm2 (Class-3) as per IS:4984:1995 PE-80 to be erected at
2.10 road crossing on or floor as directed for laying of cable. The mt 22,000.00 487.00
pipes as following size of dia & weight per 6 mtr. (E) 90 mm
Providing & laying approved make ISI marked HDPE 6Kg /
cm2 (Class-3) as per IS:4984:1995 PE-80 to be erected at
2.11 road crossing on or floor as directed for laying of cable. The mt 22,000.00 725.00
pipes as following size of dia & weight per 6 mtr. (F) 110 mm
Total of Cable Trenches, Manholes & Pipes
SITC of Flexible PVC insulated multi strand multi core 1.1 kv
3.1 grade ISI marked copper wires of following size to be erected Mtr 1.00 46.00
as directed.(f) 1.50 Sq.mm 4 core round PVC sheathed
Supply and laying of XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables in Existing Cable Trench / Mtr 275.00 282.00
50 sq.mm x 3.5 c Al. cable
3.3 35 sq.mm x 3.5 c Al. cable Mtr 275.00 218.00
3.4 25 sq.mm x 4 c Al. cable Mtr 8,250.00 189.00
3.5 16 sq.mm x 4 c Al. cable Mtr 8,250.00 152.00
3.6 10 sq.mm x 4 c Al. cable Mtr 8,250.00 139.00
3.7 existing laid Cable recovery ( Per mtr Length ), Mtr 5,775.00 14.00
Disconnecting the cable connection and Providing straight
joint with PVC mould using heat shrink /cast resin type epoxy
compound Insulating material and making the joint complete
using necessary in line connectors, hardener, earth continuity
connection, spacers etc. and reconnecting the same & ensure
the joint resistance within the limits as per IS.
(A) up to 25 Sq mm Cable no. 11,065.00 1,073.00
(B) 35 to 95 Sq. mm cable. no. 1.00 1,535.00
3.9 Making of burnt Loop-IN, Loop-Out in poles no. 2,970.00 264.00
4 Street Light Pole -
Installation Testing & Commissioning up to 6 Mtr Tubuler
Pole/ Swaged Pole. with All kind of Accessories MCB,
Junction Box, Pole Numbering With 2 coat of Paint, Muffing,
stud type terminal and arrangement for cable termination as
per details given by manufacturer considering site
ESTIMATE Page : 7 of
Installation Testing & Commissioning up to 6 Mtr. Octagonal
pole/ Conical pole, any flanged mounted pole with All kind of
Accessories MCB, Junction Box, Pole Numbering With 2 coat
of Paint, stud type terminal and arrangement for cable
termination as per details given by manufacturer considering
site requirement.
Installation Testing & Commissioning up to 7 Mtr. to 10 Mtr.
Tubuler Pole/ Swaged Pole. with All kind of Accessories
MCB, Junction Box, Pole Numbering With 2 coat of Paint,
Muffing stud type terminal and arrangement for cable
termination as per details given by manufacturer considering
site requirement.
Installation Testing & Commissioning up to 7 Mtr.to 10 Mtr
Octagonal pole/ Conical pole, any flanged mounted pole with
All kind of Accessories MCB, Junction Box, Pole Numbering
With 2 coat of Paint, stud type terminal and arrangement for
cable termination as per details given by manufacturer
considering site requirement.
Installation Testing & Commissioning up to 11 Mtr. to
Mtr.Tubuler Pole/ Swaged Pole.with All kind of Accessories
MCB, Junction Box, Pole Numbering With 2 coat of Paint,
Muffing stud type terminal and arrangement for cable
termination as per details given by manufacturer considering
site requirement.
Installation Testing & Commissioning up to 11 Mtr.to 16 Mtr
Octagonal pole/ Conical Pole, any flanged mounted pole with
All kind of Accessories MCB, Junction Box, Pole Numbering
With 2 coat of Paint, stud type terminal and arrangement for
cable termination as per details given by manufacturer
considering site requirement.
Providing cement concrete.for foundation or for concrete
filling in 1:2:4 ratio with 20 to 25 mm stone metal duly
plastered with necessary curing for pole /Panel muffing or any
Providing TMT Bar FE 500/500D reinforcement for RCC work
4.8 including bending, binding and placing in position complete Kg. 13,750.00 75.46
upto floor two level.
SITC of 0.1 to 2 Mtr G.I.bracket with 2 coat P.U. Paint with
primer(Any Arm Bracket as per architect design).
Note : Sample must be Approved from Client / Architect /
Consultant before supply.
Painting of street light pole with bracket complete with two
4.1 coats of Aluminium paint for following size of pole. no 35.00 213.00
(A) up to 4 mtr
Painting of street light pole with bracket complete with two
4.11 coats of Aluminium paint for following size of pole. no 2,994.00 263.00
(B) up to 6 mtr.
Painting of street light pole with bracket complete with two
coats of Aluminium paint for following size of pole.
(C) up to 9 mtr
Painting of street light pole with bracket complete with two
4.13 coats of Aluminium paint for following size of pole. no 328.00 552.00
(D) up to 10 to 13 mtr / 16 mtr
4.14 PU base primer and PU Paint on pole up to 4.0 Mtr no 45.00 753.00
PU base primer and PU Paint on pole above 4.0 Mtr up to
PU base primer and PU Paint on pole above 8.0 Mtr up to
PU base primer and PU Paint on pole above 12.0 Mtr up to
SITC of Pole Numbering as per Engineer in charge, Charges
ESTIMATE Page : 8 of
Pole dismantling, carting and to submit at AMC store. ( 4 mtr
to 10 mtr height)
Pole dismantling, carting and to submit at AMC store. ( 10 mtr
to 16 mtr height) 12 NOS OF Foundation BOLT
Supply of Foundation bolt for 12 Mtr. To 30 Mtr. High Mast as
Any height and type pole alignment
Supply and Installation for Modification work of relocation of
Junction Box upto 1.2 Mtr. From bottom. Scope of work:- Hole
4.23 Drilling and Fixing of Junction box with loop in loop out cable no 544.00 941.00
in Existing GI / DWC Pipe with connection of Fixtures and
Supplying and erecting A class / B Class Galvanized iron pipe
having smooth finished bore of the pipe on both ends erected
nuts and bolts along the pole / wall shaping the pipe as per
site requirement. Pipe dia as following.
Supplying and erecting A class / B Class Galvanized iron pipe
having smooth finished bore of the pipe on both ends erected
4.25 nuts and bolts along the pole / wall shaping the pipe as per Mtr 1.00 323.00
site requirement. Pipe dia as following.
RCC/Asphalt road cutting to accommodate C-PVC 25 mm
heavy duty pipe minimum 2 x 2 inch (DXW) for cable laying
and reinstate with cementing in proper manner. (It also
include supply of C-PVC 25 mm heavy duty pipe & laying of
Note : It is mandatory in the scope of successful bidder to
execute this work as many times ( for as as many quantity) as
per actual site conditions during entire contract period as and
4.27 MS tubular sleeve 2 mtr long 219 mm dia extention piece no 68.00 6,690.00
Total of Street Light Pole
Chemical Type Earthing
Supplying & erecting in earthpit of minimum bore dia. 225mm
size , approved make Safe Earthing Electrode consisting
Pipe-in-Pipe Technology as per IS 3043-1987 made of
Copper Pipes having Outer pipe dia of 50mm having , Inner
pipe dia of 40 mm , connection terminal dia of 14 mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for following
type of applications.
(a) For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
(a) For Electrical Installation up to 440V in normal soil Length
Back filling compound - 1 Nos Bag of 25 Kg.
Pipe type earthing with 40 mm dia 2.5 mtr long 'B' grade G.I.
pipe with necessary coupling buch buried in specially
prepared earth pit & G.I. earth wire of 8 SWG erected &
connected as directed (For panel)
ESTIMATE Page : 9 of
Plate Type Earthing
Supplying & erecting funnel type earthing having earth plate
of following size burred in specifically prepared earth pit 3 mtr.
below ground with 40 kg. charcoal and salt with alternate
layers of charcoal & salt, 20mm.dia. G.I. pipe with Funnel with
a wire mesh for watering & bricks masonry block, C.I. Cover
5.4 complete as per para 7.3 of IS 3043 with necessary length of Ea. 3.00 2,543.00
double Galvanised Iron / copper earth wire No 6 SWG bolted
with lug to the plate and covered in 12 mm dia. G.I. pipe
mtr long complete connected to the nearest switch gear with
end socket as per direction & duly tested by earth tester
confirming to IS (As per drawing) with following specification
With 45 x 45 x 0.35 cms. G.I. earth plate
Total of Earthing
6 Miscellanious -
Replacement of lightning arrestor as per actual site condition
during entire contractor period as and when required
Replacing of Head frame for 12 mtr. To 30 mtr. High mast
Replacing of Wire rope for 12 Mtr. To 30 Mtr. High Mast
Ligting System.
Replacement of Traveling cable for 12Mt. to 30 Mt. High Mast
Lighting System.
Replacement of Double winch drum for 12 Mtr. To 30 Mtr.
High Mast Lighting System
Rewinding of electrical motor for 12 Mtr. To 30 Mtr. High Mast
Lighting System.
Replacement of electrical motor for 12 Mtr. To 30 Mtr. High
Mast Lighting System.
Dismantling of 12Mt. to 30 Mt. High Mast Lighting System &
Carting to AMC store.
Installation of 12 Mtr. To 30 Mtr. High Mast Lighting System.
With loading / Unloading
Replacement of Lent ran carriage for 12 Mtr. To 30 Mtr. High
Mast Lighting System
To carry out census of existing street light poles, Post top
pole and feeder pillar (The same to be incorporated in eastern
side) in entire city with help of mobile app of any king of latest
6.11 equipment (Geo-coordinate mapping) depicting longitude and lot 1.00 5,00,000.00
latitude and code of each street light poles as per the formate
indicated in the tender
(To be complete within 3 months)
Total of Miscellanious
Reinstate of paver block with back filling. Waterring,PCC and
fixing blocks in proper manner.
SITC of Cement 1:5:10 (1 Cement: 5 Coarse sand: 10 hard
broken stone aggregates 40 mm nominal size) and curing
complete excluding cost of form work in (A) Foundation and
ESTIMATE Page : 10 of
Providing and Laying of Rubber Moulded Paver Block
Grey/Coloured 60 mm thick, M-35 Grade of any size ; shape
(Usually Uni-Paver Blocks) using black trap good quality
aggragate of 20 mm nominal size for footpath, parking areas,
service lanes and other areas as mentioned in the drawing /
instruction of engineer in charge. Cost includes formworks
using rubber mould, Rate providing and laying paver blocks
as per required grading and specification. The paver block
shall be echanically
7.3 compacted. The work of paving blocks shall be executed in Sq.Mtr. 173.00 475.00
line and level by skill mason of flooring work only. It should be
laid in such a way that the no cutting of the paver block to be
necessary. if cutting of paver
block necessary then it should be cut by machine only and
carting. The finished surface of the paver block shall have
resonably good, plain finished. Paver blocks shall be
compacted and shall be relaid if necessary. Gravel or such
type of materials shall not be allowed for production. Laying
on 5 cms thick sand
Total of Civil Work
ESTIMATE Page : 11 of
Document : SECTION-B2, SITC FOR Streetlight work
Project : Street Light Work Ahmedabad
Client : Ahmedabad Municipal Corporation
Description Amount
1 Section Feeder Panels
5 Cable & Termination
6 Street Light Pole & Bracket
7 Light Fixture
ESTIMATE Page : 12 of
DESCRIPTION UNIT
NO. QTY RATE TOTAL
Section Feeder Panels Type-C
"Supplying, unloading at site, shifting to site, assembling, leveling,
grouting, erecting, Testing, & Commissioning double
compartmentalized Street light control panel with IP 55 protection &
Enclosure should be powder coated fabricated from 12 Gauge M.S.
sheet & folded channel totally enclosed cubical type. with pad lock
arrangement. The successful tenderer will have to prepare general
arrangement with dimensions & get it approve through Architect/
Consultant. All civil work including RCC platform for street light panel
should be in scope of Electrical contractor complete in all respect as
per detail drawing and directed by engineer in charge. with the
mm height MS angle covered stand.
The switchboard (panel) shall have provision for future expansion &
shall be modular in construction. The bus bars shall be connected
with C type clamps without any drilling on the bus bars.
SITC of the IP 65 Smart Section feeder panel with space for Smart
Energy monitoring system and 2 number of 3 phase Energy meter of
Supply Company for the Street Lighting Consisting of following
Incoming : 100 Amp FP MCCB with the spreader link with in built
earth fault relay
R-Y-B-On-Off indicating Lamp with control fuse.
Set of 100 A. FP tinned copper busbars of EC. grade & adequate
capacity, size & insulated with colour tape & should be tined at all
Auto/Manual bypass switch with indicating lamp
Meter : VAF meter equivalent to Enercon make ELF 3259 with 100/
Outgoing : MCB's Should be of 10 KA.
Timer Equivalent to Theben make Astronomical type with the battery
back up : 2 nos.
40 amp. FP Power Contactor : 2 nos.
6 - 32 amp. DP Power Contactor : 8 nos.
40 Amp. FP MCB : 4 nos.
6 -32 Amp. FP MCB : 2 nos.
6 - 32 amp. SP MCB : 18 nos.
5 KVAR Capacitor with the 40 amp TP capacitor duty contactor with
the 10 minute time delay relay.
Panel Should Have lockable Space to incorporate the 2 nos of the
phase energy meter with its main switches with separate cable entry
with separate compartment & Separate door. Also door higes are
made from solid pin and bolted type. No welding are alloved for
Section Feeder Panels Type-D -
ESTIMATE Page : 13 of
Supplying, unloading at site, shifting to site, assembling, leveling,
grouting, erecting, Testing, & Commissioning double
compartmentalized Street light control panel with IP 55 protection &
Enclosure should be powder coated fabricated from 12 Gauge M.S.
sheet & folded channel totally enclosed cubical type. with pad lock
arrangement. The successful tenderer will have to prepare general
arrangement with dimensions & get it approve through Architect/
Consultant. All civil work including RCC platform for street light panel
should be in scope of Electrical contractor complete in all respect as
per detail drawing and directed by engineer in charge. with the
mm height MS angle covered stand.
The switchboard (panel) shall have provision for future expansion &
shall be modular in construction. The bus bars shall be connected
with C type clamps without any drilling on the bus bars.
SITC of the IP 65 Smart Section feeder panel with space for Smart
Energy monitoring system and 2 number of 3 phase Energy meter of
Supply Company for the Street Lighting Consisting of following
Incoming : 63 Amp FP MCB with the spreader link with in built earth
R-Y-B-On-Off indicating Lamp with control fuse.
Set of 63 A. FP tinned copper busbars of EC. grade & adequate
capacity, size & insulated with colour tape & should be tined at all
Auto/Manual bypass switch with indicating lamp
Meter : VAF meter equivalent to Enercon make ELF 3259 with 63/ 5 A
Outgoing : MCB's Should be of 10 KA.
Timer Equivalent to Theben make Astronomical type with the battery
back up : 2 nos.
40 amp. FP Power Contactor : 2 nos.
6 - 32 amp. DP Power Contactor : 8 nos.
40 Amp. FP MCB : 2 nos.
6 -32 Amp. FP MCB : 2 nos.
6 - 32 amp. SP MCB : 12 nos.
5 KVAR Capacitor with the 40 amp TP capacitor duty contactor with
the 10 minute time delay relay.
Panel Should Have lockable Space to incorporate the 2 nos of the
phase energy meter with its main switches with separate cable entry
with separate compartment & Separate door. Also door higes are
made from solid pin and bolted type. No welding are alloved for
ESTIMATE Page : 14 of
FEEDER SECTION PILLAR TYPE-A (Regular)
750 W x 600 L x 1050 H (As per drawing)
Supply, installation, Testing and commissioning of the Feeder Section
Pillars as per specifications, IS and Drawings
The unit rate for each item shall include : Call for final inspection prior
to dispatch. Delivery of the fidder pillar / section pillar to site. Shifting
of the fidder / section piller from site to store to the suitable location.
& Fixing of Section Pillar. Assembly and wiring of component supplied
separately. Installation of section
piller to including removing old section pillar. Earthing all components,
frame etc. to a common internal earth bar. M.S. parts should painted
with powder coating.
Supply & fixing all accessories and supporting structure. Supply & Set 72.00 49,161.00
fixing of M.S. 40 x 40 x 6 channels for fixing the panels. Connection,
testing and commissioning Checking of internal connection and
wiring, operation of switches, starter, MCCB, relays,
contactors etc. Supply of necessary tools, hardware, testing
equipment etc. etc. Electrical contractor shall carry out the insulation
test at site and all the readings shall be submitted in duplicate to the
consultant or engineer-in- charge.
All civil work including RCC platform for street light panel should be in
scope of Electrical contractor complete in all respect as per detail
drawing and directed by engineer in charge with the MS angle
covered stand. Approval from State Electricity Board & Liason work.
Also door higes are made from solid pin and bolted type. No welding
are alloved for hinges.
FEEDER SECTION PILLAR TYPE-B-1
SIZE :- 750 W x 600 L x 750 H (As per drawing)
Supply, installation, Testing and commissioning of the Feeder Section
Pillars as per specifications, IS and Drawings.
The unit rate for each item shall include : Call for final inspection prior
to dispatch. Delivery of the fidder pillar / section pillar to site. Shifting
of the fidder / section piller from site to store to the suitable location.
Shifting & Fixing of Section Pillar. Assembly and wiring of component
supplied separately. Installation of section piller to including old
section pillar. Earthing all components, frame etc. to a common
internal earth bar.M.S. Parts should painted with powder coating.
Supply & fixing all accessories and supporting structure. Supply & Set 45.00 30,602.00
fixing of M.S. 40 x 40 x 6 channels for fixing the panels. Connection,
testing and commissioning. Checking of internal connection and
wiring, operation of switches, starter, MCCB, relays, contactors
etc.Supply of neccessary tools, hardware, testing equipment etc.
Electrical contractor shall carry
out the insulation test at site and all the readings shall be submitted in
duplicate to the consultant or engineerin-
charge. All civil work including RCC platform for street light panel
should be in scope of Electrical contractor complete in all respect as
per detail drawing and directed by engineer in charge with the MS
angle covered stand. Approval from state Electricity Board & Liason
work.Also door higes are made from solid pin and bolted type. No
welding are alloved for hinges.
FEEDER SECTION PILLAR TYPE - B-2 Set 38.00 30,602.00
5 1200 W x 400 L x 900 H (As per drawing)
ESTIMATE Page : 15 of
FEEDER SECTION PILLAR TYPE - B-3
Size :- 600 x 600 x 250 mm
Supplying & erecting approved make IP 55 grade Company
fabricated Timer Panel of following capacity for switch On-Off
street lights on time scheduling basis made from 12 G CRCA
sheet duly epoxy power painted inside and outside with hinged
doors and locking arrangement consisting of suitable size of
Pole MCB and 4 pole contactor (cat-III)with Astronomical digital
time switch, auto manual switch of same make and suitable
input and output Bakelite terminals and with door earthing no 81.00 14,668.00
approved by Engineer in charge. Supply & fixing of M.S. 40 x
for fixing the panels. panel is also suitable to fit on wall. Also
door higes are made from solid pin and bolted type. No welding
are alloved for hinges. All civil work including RCC platform for
street light panel should be in scope of Electrical contractor
complete in all respect as per detail drawing and directed by
engineer in charge with the MS angle covered stand.
Removing of Section Feeder Panel
Dismantling and removing of existing section feeder pillar as said
location by engineer in charge complete in all respect as it is original
with necessary civil work foundation, cable termination, with extra
required various sizes cables & with cable joints if needed etc. as per
requirement or as per instruction of engineer in charge.
Installation of Section Feeder Panel
Installation Testing and Comissioning of New / existing section feeder
pillar as said location by engineer in charge complete in all respect as
it is original with necessary cable termination, with extra required
various sizes cables & with cable joints if needed etc. as per
requirement or as per instruction of engineer in charge.
Upgradation of Section Feeder Panel
Upgradation of existing section feeder pillar Install MCB instead of
Fuse as said location by engineer in charge complete in all respect as Set 5.00 3,000.00
it is original with necessary cable termination etc. as per requirement
or as per instruction of engineer in charge.
Total amount for Section Feeder Panels
Total amount for Section Feeder Panels
SITC of the MCB's ( 10 KA ) Timers , & Contactors With the Dinrail
Channel providing and erecting Miniature circuit breaker single pole
0.5A to 2A system and having breaking capacity 10 KA to be erected
in existing box. confirming to IS 8828/1996 with ISI Mark
Miniature circuit breaker single pole suitable to operate on 240 V A.C.
system and having breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark
6 to 25 A SP MCB
Providing & erecting 240 V MCB double pole switch for motor &
inductive load (C Curve) having 10 KA breaking capacity & confirms
to IS : 8828 in existing box having following capacity
6 to 32 A DP MCB
Approved make ELCBs / RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and
suitable for operation on single phase 240 V. having characteristic of
quick action & tripping with all advance feature & do not incorporate no 2.00 1,950.00
any electronic component. for following Max. rating erected as
25 to 32A / 30mA/100 mA DP ELMCB
ESTIMATE Page : 16 of
Approved make ELCBs / RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and
suitable for operation on single phase 240 V. having characteristic of
quick action & tripping with all advance feature & do not incorporate no 2.00 2,213.00
any electronic component. for following Max. rating erected as
40 A / 100 mA DP ELMCB
Providing & erecting 415 V MCB three Pole for Motor & Inductive
Load (C Curve) having 10KA breaking capacity & confirms to IS :8828
in existing box having following capacity
(a) 6 to 32 Amp. Cat.III
Providing & erecting 415 V MCB three Pole for Motor & Inductive
Load (C Curve) having 10KA breaking capacity & confirms to IS :8828
in existing box having following capacity
(b) 40 Amp. Cat.III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load
(C Curve) having 10KA breaking capacity & confirms to IS :8828 in
existing box having following capacity
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load
(C Curve) having 10KA breaking capacity & confirms to IS :8828 in
existing box having following capacity
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load
(C Curve) having 10KA breaking capacity & confirms to IS :8828 in
existing box having following capacity
6 to 32A FP MCB
Supplying & erecting power contactor for time switch complete
erected as per direction Cat III no 2.00 1,865.00
20 [B] 2 pole 250V 32 Amp.
Supplying & erecting power contactor for time switch complete
erected as per direction Cat III no 2.00 2,755.00
21 [D] 4 pole 440V 40 Amp.
Supplying & erecting approved make Digital time switch having lithium
cell 6 years operative and operate battery backup 1 channel day clock
with 14 memory programme, suitable to operate on 240V + 5%, 16A
with, floating contacts Minimum switching setup time 1 minimum &
LCD display. Also comprised permanent ON/OFF switching.
Programming switches & housed in fire proof thermoplastic enclosure
& transparent cover erected as required with necessary connection
erected as directed.
To Supply & Install Takti (Size 12" X 8 " in 16 gauge M.S. Plate) on
street light pole with painting in the prescribed matter as directed by no 83.00 424.00
23 the engineer in charge and take two photograph of the same takti.
Total amount for MCB
Total amount for MCB
Making trench in soft soil of suitable width of 90 cms deep from the
final ground level or road level for laying cable or locating the fault all
over the run and backfilling the same & clearing the site by removing mt 1,16,093.00 55.00
debris & Shifting of the debris & making site good As per the
Instruction of the Engineer Incharge.
Making trench in Hard murum / Tar Road of suitable width of 90 cms
deep from the final ground level / road level for laying cableor locating
the fault all over the run and backfilling the same and making the mt 29,024.00 74.00
surface proper. by removing debris & Shifting of the debris & making
site good As per the Instruction of the Engineer Incharge.
26 (B) If additional machinery like hammer driller or JCB use [Add] mt 3,207.00 354.00
ESTIMATE Page : 17 of
Covering of cable with second class bricks laid cover the cable
crosswise & also on both sides with covering of 7. 5 Cms. layer of
sand above & below cable (cable shall be laid in 0.9mtr.deep &
Mtr.wide trench). Where there are more than one cable in the trench
on either side of the cable, 5 Cms. over lapping of bricks shall be
Driling the road without breaking the road surface (Asphalt) for laying
of cable for feeding power supply by making Suitable size of holes at
both ends complete.
(A) Up to 100 mm bore dia
Driling the road without breaking the road surface (Asphalt) for laying
of cable for feeding power supply by making Suitable size of holes at
both ends complete.
(B) Up to 150 mm bore dia
Construction of brick masonery pulling chamber 1250 mm x 1250 mm
inside clear size and depth upto 1.2 meter with 350 mm thick
masonery in cerment mortar proporation 1:5,cement finish cement
plaster in CM proportion of 15 mm thickness from inside with 150 mm
thick PCC at bottom with top slab minmum 200 mm thickness in M20
grade with reinforcement. The rate shall be inclusive of providing and
fixing frame and cover of FRC for the Heavy Duty. Rate also inclusive
of excavation and back filling & clearing the site by removing debris &
Shifting of the debris & making site good As per the Instruction of the
Engineer Incharge complete in all respect.
Total Amount for Cable Trench
Total Amount for Cable Trench
Providing & laying. Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II ) Anti Rodent type with
necessary connecting accessories of same material at required depth
for laying of cable. below ground / road surface for enclosing cable
with Excavation and backfilling the same to make ground as per
original. The corrugated pipe shall be able to withstand compression
test at 750 N when reaching a deflection of 5 %.
Providing & laying. Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II ) Anti Rodent type with
necessary connecting accessories of same material at required depth
for laying of cable. below ground / road surface for enclosing cable
with Excavation and backfilling the same to make ground as per
original. The corrugated pipe shall be able to withstand compression
test at 750 N when reaching a deflection of 5 %.
Providing & laying. Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II ) Anti Rodent type with
necessary connecting accessories of same material at required depth
for laying of cable. below ground / road surface for enclosing cable
with Excavation and backfilling the same to make ground as per
original. The corrugated pipe shall be able to withstand compression
test at 750 N when reaching a deflection of 5 %.
Providing & laying. Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II ) Anti Rodent type with
necessary connecting accessories of same material at required depth
for laying of cable. below ground / road surface for enclosing cable
with Excavation and backfilling the same to make ground as per
original. The corrugated pipe shall be able to withstand compression
test at 750 N when reaching a deflection of 5 %.
ESTIMATE Page : 18 of
Providing & laying approved make ISI marked HDPE 6Kg / cm2
(Class-3) as per IS:4984:1995 PE-80 to be erected at road crossing
on or floor as directed for laying of cable. The pipes as following size mt 9,625.00 487.00
of dia & weight per 6 mtr.
(E) 90 mm inner Dia
Providing & laying approved make ISI marked HDPE 6Kg / cm2
(Class-3) as per IS:4984:1995 PE-80 to be erected at road crossing
on or floor as directed for laying of cable. The pipes as following size mt 9,625.00 725.00
of dia & weight per 6 mtr.
(F) 110 mm inner Dia.
Total Amount for pipes
Total Amount for pipes
Supply and laying of XLPE(IS:7098) )(I)-88 ISI marked armored cable
of Cu. / Aluminum conductor of 1.1 KV.grade of following sizes in
ground or in pre-laid DWC pipe / Trenches with necessary cable
identification mark to be provided at distance of 15 mt. & with 2 nos.
of 16 SWG G.I. wire continuous in length per cable.
37 50 sq.mm x 3.5 c Al. cable mt 605.00 282.00
38 35 sq.mm x 3.5 c Al. cable mt 41,250.00 218.00
39 25 sq.mm x 4 c Al. cable mt 33,750.00 189.00
40 16 sq.mm x 4 c Al. cable mt 68,750.00 152.00
41 10 sq.mm x 4 c Al. cable mt 5,50,000.00 139.00
Supplying and laying Flexible PVC insulated multistrand multicore
42 kv grade ISI marked copper wires of following size.
SITC of 1.00 Sq.mm 3 core round PVC sheathed
43 Scope also include the removal of existing wire if required
SITC of 1.50 Sq.mm 3 core round PVC sheathed
44 Scope also include the removal of existing wire if required
SITC of cable with 5 core x 2.5 Sq. mm EPR insulated PVC scheated
Copper Cable with required length from bottom Junction Box to top
junction box of Highmast, with needed all electrical mechanical
accessories and tools to Commission the Highmastt poles as per
tender terms, conditions & Specifications.The scope also includes the
deposition of the existing removed cables and related accessories at
the location as directed by Engineer Incharge Scope also include
the removal of existing wire if required
Cable Termination
Supplying & fixing Double Compression type Brass glands & making
joint with necessary crimping socket of long nack type connecting the
same to various equipment etc. for the following sizes:
46 50 sq.mm x 3.5 c Al. cable no 56.00 150.00
47 35 sq.mm x 3.5 c Al. cable no 2,200.00 150.00
48 25 sq.mm x 4 c Al. cable no 2,200.00 126.00
49 16 sq.mm x 4 c Al. cable no 4,640.00 107.00
50 10 sq.mm x 4 c Al. cable no 1,100.00 90.00
Total Amount for Cable & Termination
Total Amount for Cable & Termination
Street light Poles & High Mast
ESTIMATE Page : 19 of
SITC of approved make FRP Pole having following specifications:
FRP Light Pole made by CNC filament winding machine using
thermoset resin polyester/epoxy resin system) having minimum 62%
glass content. The pole should be in one piece and tapered round in
shape, having smooth finish and should be totally free from corrosion
as well as non conductive & shock proof Pole should be provided with
FRP Anchor Base and it should be heavy duty, or MS Material duly
painted with Epoxy paint.
Pole should be flame retardant as per IS 6746. Resin used shall be
UV resistance and pigmented. A highly weather resistant
polyurethane coating shall be applied to the pole after applying
suitable primer system that ensures proper adhesion of the paint.
51 Minimum coating thickness shall be 80 to 100 micron. Deflection of no 321.00 8,934.00
the pole shall not exceed more than 10% of the length of pole for the
given load“ Pole should be generally made as per the dimensional
data, performance criteria and some interchangeability features of
poles as per standard ANSI C 136.20 latest version or ASTM D
4923/01 including cable termination box with necessary accessories .
The size of pole and type of installation with foundation as per
manufacturer details and site requirement are as below .
(1) Suitable for base plate mounting single arm Bracket.
[C] Overall length of 3.5 Mtr. Average Thickness: 7mm.
Top/ Bottom OD Dia A/F 89/135 mm ± 2mm approx. Approx. Weight
of Pole 15kg. approx. (Without Base) Anchor Base (Size 250X250 &
SITC of approved make FRP Pole having following specifications:
FRP Light Pole made by CNC filament winding machine using
thermoset resin polyester/epoxy resin system) having minimum 62%
glass content. The pole should be in one piece and tapered round in
shape, having smooth finish and should be totally free from corrosion
as well as non conductive & shock proof Pole should be provided with
FRP Anchor Base and it should be heavy duty, or MS Material duly
painted with Epoxy paint.
Pole should be flame retardant as per IS 6746. Resin used shall be
UV resistance and pigmented. A highly weather resistant
polyurethane coating shall be applied to the pole after applying
suitable primer system that ensures proper adhesion of the paint.
52 Minimum coating thickness shall be 80 to 100 micron. Deflection of no 161.00 9,696.00
the pole shall not exceed more than 10% of the length of pole for the
given load“ Pole should be generally made as per the dimensional
data, performance criteria and some interchangeability features of
poles as per standard ANSI C 136.20 latest version or ASTM D
4923/01 including cable termination box with necessary accessories .
The size of pole and type of installation with foundation as per
manufacturer details and site requirement are as below .
(1) Suitable for base plate mounting single arm Bracket.
[D] Overall length of 4 Mtr. Average Thickness: 7mm.
Top/ Bottom OD Dia A/F 89/145 mm ± 2mm approx. Approx. Weight
of Pole 19 kg approx. (Without Base)
Anchor Base (Size 250X250 & 12mm th.)
ESTIMATE Page : 20 of
Supply of approved make FRP Pole having following specifications:
FRP Light Pole made by CNC filament winding machine using
thermoset resin polyester/epoxy resin system) having minimum 62%
glass content. The pole should be in one piece and tapered round in
shape, having smooth finish and should be totally free from corrosion
as well as non conductive & shock proof Pole should be provided with
FRP Anchor Base and it should be heavy duty, or MS Material duly
painted with Epoxy paint.
Pole should be flame retardant as per IS 6746. Resin used shall be
UV resistance and pigmented. A highly weather resistant
polyurethane coating shall be applied to the pole after applying
suitable primer system that ensures proper adhesion of the paint.
Minimum coating thickness shall be 80 to 100 micron. Deflection of no 161.00 13,920.00
the pole shall not exceed more than 10% of the length of pole for the
given load“ Pole should be generally made as per the dimensional
data, performance criteria and some interchangeability features of
poles as per standard ANSI C 136.20 latest version or ASTM D
4923/01 including cable termination box with necessary accessories .
The size of pole and type of installation with foundation as per
manufacturer details and site requirement are as below .
(1) Suitable for base plate mounting single arm Bracket.
[H] Overall length of 6 Mtr. Average Thickness: 7.5mm
Top/ Bottom OD Dia A/F 89mm ± 2mm approx. approx. Weight of
Pole 32 kg approx. (Without Base) Anchor Base (Size 300X300 &
Supply & Installation of GI Pole made out of B CLASS ERW G.I. PIPE
for road having Height - 4 metre having thickness of 4.5 mm, 165 mm
outer uniform dia., with base plate of 450 x 450 x 12 mm with stiffener
plate with Seprate integral type junction box ( For Street
light ) , with j bolt, necessary hardware as per detail, with necessary
Reducer / Coupler / for fixing of light fixtures & Hinged access door
with welded chain between pole and hinged door with Allen key no 321.00 13,243.00
access the integral junction box, Fabrication work complete in all
respect as per given detail with one coat of zinc oxide complete in all
respect as per Drawing. Rate shall be including two coats of PU paint
of shade as per drawing or as directed by Architect ( effective length
should be 4000mm above GF) (Sample to be approved )
Supply & Installation of GI Pole made out of B CLASS ERW G.I. PIPE
for road having Height - 6 metre having thickness of 4.5 mm, 165 mm
outer uniform dia., with base plate of 450 x 450 x 12 mm with stiffener
plate with Seprate integral type junction box ( For Street
light ) , with j bolt, necessary hardware as per detail, with necessary
Reducer / Coupler / for fixing of light fixtures & Hinged access door
with welded chain between pole and hinged door with Allen key no 9.00 19,860.00
access the integral junction box, Fabrication work complete in all
respect as per given detail with one coat of zinc oxide complete in all
respect as per Drawing. Rate shall be including two coats of PU paint
of shade as per drawing or as directed by Architect ( effective length
should be 6000mm above GF) (Sample to be approved )
ESTIMATE Page : 21 of
Supply & Installation of GI Pole made out of B CLASS ERW G.I. PIPE
for road having Height - 7 metre having thickness of 4.5 mm, 165 mm
outer uniform dia., with base plate of 450 x 450 x 12 mm with stiffener
plate with Seprate integral type junction box ( For Street
light ) , with j bolt, necessary hardware as per detail, with necessary
Reducer / Coupler / for fixing of light fixtures & Hinged access door
with welded chain between pole and hinged door with Allen key no 9.00 23,170.00
access the integral junction box, Fabrication work complete in all
respect as per given detail with one coat of zinc oxide complete in all
respect as per Drawing. Rate shall be including two coats of PU paint
of shade as per drawing or as directed by Architect ( effective length
should be 7000mm above GF) (Sample to be approved )
Supply & Installation of GI Pole made out of B CLASS ERW G.I. PIPE
for road having Height - 8 metre having thickness of 4.5 mm, 165 mm
outer uniform dia., with base plate of 450 x 450 x 16 mm with stiffener
plate with Seprate integral type junction box ( For Street
light ) , with j bolt, necessary hardware as per detail, with necessary
Reducer / Coupler / for fixing of light fixtures & Hinged access door
with welded chain between pole and hinged door with Allen key no 321.00 26,480.00
access the integral junction box, Fabrication work complete in all
respect as per given detail with one coat of zinc oxide complete in all
respect as per Drawing. Rate shall be including two coats of PU paint
of shade as per drawing or as directed by Architect ( effective length
should be 8000mm above GF) (Sample to be approved )
Supply & Installation of GI Pole made out of B CLASS ERW G.I. PIPE
for road having Height - 9 metre having thickness of 4.5 mm, 165 mm
outer uniform dia., with base plate of 450 x 450 x 16 mm with stiffener
plate with Seprate integral type junction box ( For Street
light ) , with j bolt, necessary hardware as per detail, with necessary
Reducer / Coupler / for fixing of light fixtures & Hinged access door
with welded chain between pole and hinged door with Allen key no 161.00 29,790.00
access the integral junction box, Fabrication work complete in all
respect as per given detail with one coat of zinc oxide complete in all
respect as per Drawing. Rate shall be including two coats of PU paint
of shade as per drawing or as directed by Architect ( effective length
should be 9000mm above GF) (Sample to be approved )
Supply & Installation of GI Pole made out of B CLASS ERW G.I. PIPE
for road having Height - 10 metre having thickness of 4.5 mm,
mm outer uniform dia., with base plate of 450 x 450 x 16 mm with
stiffener plate with Seprate integral type junction box ( For Street
light ) , with j bolt, necessary hardware as per detail, with necessary
Reducer / Coupler / for fixing of light fixtures & Hinged access door
with welded chain between pole and hinged door with Allen key no 161.00 33,100.00
access the integral junction box, Fabrication work complete in all
respect as per given detail with one coat of zinc oxide complete in all
respect as per Drawing. Rate shall be including two coats of PU paint
of shade as per drawing or as directed by Architect (effective length
should be 10000mm above GF) (Sample to be approved)
ESTIMATE Page : 22 of
Supply & Installation of GI Pole made out of B CLASS ERW G.I. PIPE
for road having Height - 11 metre having thickness of 4.5 mm,
mm outer uniform dia., with base plate of 450 x 450 x 16 mm with
stiffener plate with Seprate integral type junction box ( For Street
light ) , with j bolt, necessary hardware as per detail, with necessary
Reducer / Coupler / for fixing of light fixtures & Hinged access door
with welded chain between pole and hinged door with Allen key no 9.00 36,410.00
access the integral junction box, Fabrication work complete in all
respect as per given detail with one coat of zinc oxide complete in all
respect as per Drawing. Rate shall be including two coats of PU paint
of shade as per drawing or as directed by Architect ( effective length
should be 11000mm above GF) (Sample to be approved )
Supplying and erecting approved make Octagonal pole made from
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable no 9.00 4,196.00
foundation (Included) as per details given by manufacturer
considering site requirement.
(A) 3 Mtr. Long 70 mm Top X 130 mm bottom dia (Tolerance are
allowed in all octagonal pole top and bottom dia +/-10%) .3 mm
thickness with 200mmX200mmX12mm base plate, 4-M16 Bolts and
450mm long with necessary G.I. J Bolts .Approx weight 29 kg
Supplying and erecting approved make Octagonal pole made from
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable no 65.00 5,501.00
foundation (Included) as per details given by manufacturer
considering site requirement.
(B) 4 Mtr. Long 70 mm Top X 130 mm bottom dia (Tolerance are
allowed in all octagonal pole top and bottom dia +/-10%), 3 mm
thickness with 200mmX200mmX12mm base plate, 4-M16 Bolts and
450mm long with necessary G.I. J Bolts .Approx weight 37 kg
Supplying and erecting approved make Octagonal pole made from
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable no 9.00 6,806.00
foundation (Included) as per details given by manufacturer
considering site requirement.
(C) 5 Mtr. Long 70 mm Top X 130 mm bottom dia (Tolerance are
allowed in all octagonal pole top and bottom dia +/-10%), 3 mm
thickness with 200mmX200mmX12mm base plate, 4-M16 Bolts and
600mm long with necessary G.I. J Bolts .Approx Pole weight 46 kg
ESTIMATE Page : 23 of
Supplying and erecting approved make Octagonal pole made from
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable no 9.00 8,111.00
foundation (Included) as per details given by manufacturer
considering site requirement.
(D) 6 Mtr. Long 70 mm Top X 135 mm bottom dia (Tolerance are
allowed in all octagonal pole top and bottom dia +/-10%), 3 mm
thickness with 200mmX200mmX12mm base plate, 4-M20 Bolts and
600mm long with necessary G.I. J Bolts .Approx Pole weight 59 kg
Supplying and erecting approved make Octagonal pole made from
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable no 9.00 11,299.00
foundation (Included) as per details given by manufacturer
considering site requirement.
(E) 7 Mtr. Long 70 mm Top X 135 mm bottom dia (Tolerance are
allowed in all octagonal pole top and bottom dia +/-10%), 3 mm
thickness with 225mmX225mmX16mm base plate, 4-M20 Bolts and
600mm long with necessary G.I. J Bolts .Approx Pole weight 67 kg
Supplying and erecting approved make Octagonal pole made from
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable no 65.00 13,872.00
foundation (Included) as per details given by manufacturer
considering site requirement.
(G) 8 Mtr. Long 70 mm Top X 155 mm bottom dia (Tolerance are
allowed in all octagonal pole top and bottom dia +/-10%), 3 mm
thickness with 260mmX260mmX16mm base plate, 4-M20 Bolts and
600mm long with necessary G.I. J Bolts Approx Pole weight 84 kg
Supplying and erecting approved make Octagonal pole made from
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable no 65.00 15,550.00
foundation (Included) as per details given by manufacturer
considering site requirement.
(H) 9 Mtr. Long 70 mm Top X 155 mm bottom dia (Tolerance are
allowed in all octagonal pole top and bottom dia +/-10%), 3 mm
thickness with 260mmX260mmX16mm base plate, 4-M24 Bolts and
750mm long with necessary G.I. J Bolts .Approx Pole weight 97 kg
ESTIMATE Page : 24 of
Supplying and erecting approved make Octagonal pole made from
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable no 65.00 19,577.00
foundation (Included) as per details given by manufacturer
considering site requirement.
(I) 10 Mtr. Long 70 mm Top X 175 mm bottom dia (Tolerance are
allowed in all octagonal pole top and bottom dia +/-10%), 4 mm
thickness with 275mmX275mmX16mm base plate, 4-M24 Bolts and
750mm long with necessary G.I. J Bolts .Approx Pole weight 145 kg
Supplying and erecting approved make Octagonal pole made from
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable no 65.00 25,283.00
foundation (Included) as per details given by manufacturer
considering site requirement.
(J) 11 Mtr. Long 90 mm Top X 210 mm bottom dia (Tolerance are
allowed in all octagonal pole top and bottom dia +/-10%), 4 mm
thickness with 300mmX300mmX20mm base plate, 4-M24 Bolts and
750mm long with necessary G.I. J Bolts .Approx Pole weight 192 kg
Supplying and erecting approved make Octagonal pole made from
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable
foundation (Included) as per details given by manufacturer
considering site requirement.
(K) 12 Mtr. Long 90 mm Top X 240 mm bottom dia, 4 mm thickness
with 320mmX320mmX20mm base plate, 4-M24 Bolts and 850mm
long with necessary G.I. J Bolts .Approx Pole weight 230 kg
Supplying and erecting approved make Conical Pole (Medium Duty )
Made from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS 2629/2633/4759,
with required base plate and integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and arrangement for cable
terminations as erected on suitable foundation (included) with
necessary GI nut-bolts/J-Bolts. as per details given by manufacturer
considering site requirement. The length of poles are as below.
(A) 3 Mtr. Long 70 mm Top X 115 mm bottom dia (Tolerance are
allowed in all conical pole top and bottom dia +/-10%),3 mm
ESTIMATE Page : 25 of
Supplying and erecting approved make Conical Pole (Medium Duty )
Made from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS 2629/2633/4759,
with required base plate and integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and arrangement for cable
terminations as erected on suitable foundation (included) with
necessary GI nut-bolts/J-Bolts. as per details given by manufacturer
considering site requirement. The length of poles are as below.
(B) 4 Mtr. Long 70 mm Top X 130 mm bottom dia (Tolerance are
allowed in all conical pole top and bottom dia +/-10%), 3 mm
Supplying and erecting approved make Conical Pole (Medium Duty )
Made from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS 2629/2633/4759,
with required base plate and integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and arrangement for cable
terminations as erected on suitable foundation (included) with
necessary GI nut-bolts/J-Bolts. as per details given by manufacturer
considering site requirement. The length of poles are as below.
(C) 5 Mtr. Long 70 mm Top X 145 mm bottom dia (Tolerance are
allowed in all conical pole top and bottom dia +/-10%), 3 mm
Supplying and erecting approved make Conical Pole (Medium Duty )
Made from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS 2629/2633/4759,
with required base plate and integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and arrangement for cable
terminations as erected on suitable foundation (included) with
necessary GI nut-bolts/J-Bolts. as per details given by manufacturer
considering site requirement. The length of poles are as below.
(D) 6 Mtr. Long 70 mm Top X 160 mm bottom dia (Tolerance are
allowed in all conical pole top and bottom dia +/-10%), 3 mm
Supplying and erecting approved make Conical Pole (Medium Duty )
Made from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS 2629/2633/4759,
with required base plate and integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and arrangement for cable
terminations as erected on suitable foundation (included) with
necessary GI nut-bolts/J-Bolts. as per details given by manufacturer
considering site requirement. The length of poles are as below.
(E) 7 Mtr. Long 70 mm Top X 175 mm bottom dia (Tolerance are
allowed in all conical pole top and bottom dia +/-10%), 3 mm
ESTIMATE Page : 26 of
Supplying and erecting approved make Conical Pole (Medium Duty )
Made from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS 2629/2633/4759,
with required base plate and integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and arrangement for cable
terminations as erected on suitable foundation (included) with
necessary GI nut-bolts/J-Bolts. as per details given by manufacturer
considering site requirement. The length of poles are as below.
(F) 8 Mtr. Long 70 mm Top X 190 mm bottom dia (Tolerance are
allowed in all conical pole top and bottom dia +/-10%), 3 mm
Supplying and erecting approved make Conical Pole (Medium Duty )
Made from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS 2629/2633/4759,
with required base plate and integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and arrangement for cable
terminations as erected on suitable foundation (included) with no 33.00 16,501.00
necessary GI nut-bolts/J-Bolts. as per details given by manufacturer
considering site requirement. The length of poles are as below.
(G) 9 Mtr. Long 70 mm Top X 205 mm bottom dia (Tolerance are
allowed in all conical pole top and bottom dia +/-10%), 3 mm
Supplying and erecting approved make Conical Pole (Medium Duty )
Made from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS 2629/2633/4759,
with required base plate and integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and arrangement for cable
terminations as erected on suitable foundation (included) with
necessary GI nut-bolts/J-Bolts. as per details given by manufacturer
considering site requirement. The length of poles are as below.
(H) 10 Mtr. Long 80 mm Top X 220 mm bottom dia (Tolerance are
allowed in all conical pole top and bottom dia +/-10%), 3 mm
Supplying and erecting approved make Conical Pole (Medium Duty )
Made from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS 2629/2633/4759,
with required base plate and integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and arrangement for cable
terminations as erected on suitable foundation (included) with
necessary GI nut-bolts/J-Bolts. as per details given by manufacturer
considering site requirement. The length of poles are as below.
(I) 11 Mtr. Long 80 mm Top X 245 mm bottom dia (Tolerance are
allowed in all conical pole top and bottom dia +/-10%), 3 mm
ESTIMATE Page : 27 of
Supplying and erecting approved make Conical Pole (Medium Duty )
Made from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS 2629/2633/4759,
with required base plate and integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and arrangement for cable
terminations as erected on suitable foundation (included) with
necessary GI nut-bolts/J-Bolts. as per details given by manufacturer
considering site requirement. The length of poles are as below.
(J) 12 Mtr. Long 80 mm Top X 260 mm bottom dia, 3 mm thickness
supplying & erecting 4.5 Meter G.I. (B Class ERW G.I.Pipes) Swaged
pole with Base Plate ,Single SMC Junction Box with all necessary
electrical mechanical accessories, Earthing jumper, Fastner, Lugs, 2 no 65.00 6,871.00
Nos.Cable Protection Pipes, Painting of pole with numbering etc as
per tender terms and conditions, Specifications and scope of work.
Supplying & erecting 5.5 Meter G.I.(B Class ERW G.I.Pipes) Swaged
pole with Base Plate ,Single SMC Junction Box with all necessary
electrical mechanical accessories, Earthing jumper, Fastner, Lugs, 2 no 1,604.00 7,403.00
Nos.Cable Protection Pipes, Painting of pole with numbering etc as
per tender terms and conditions, Specifications and scope of work.
Supplying & erecting 7.0 Meter G.I.(B Class ERW G.I.Pipes) Swaged
pole with Base Plate ,Single SMC Junction Box with all necessary
electrical mechanical accessories, Earthing jumper, Fastner, Lugs, 2 no 963.00 8,716.00
Nos.Cable Protection Pipes, Painting of pole with numbering etc as
per tender terms and conditions, Specifications and scope of work.
Supplying & erecting 9.5 Meter G.I.(B Class ERW G.I.Pipes) Swaged
pole with Base Plate ,Single SMC Junction Box with all necessary
electrical mechanical accessories, Earthing jumper, Fastner, Lugs, 2 no 1,283.00 12,870.00
Nos.Cable Protection Pipes, Painting of pole with numbering etc as
per tender terms and conditions, Specifications and scope of work.
SITC of extra junction box with all required accessories and one no.
85 cable protection GI pipe of 40 mm dia as per drawing.
SITC of extra junction box with all required accessories and two no.
86 cable protection GI pipe of 40 mm dia as per drawing.
ESTIMATE Page : 28 of
SITC of 9M Conical Bended Hot Dip Galvanized with PU Painted with
Top dia 75mm and Bottom Dia 170mm with pole thickness 3mm
along with Base plate 275mmx275mmx16mm with Single Arm
Bracket of 300mm with provision for 4 nos of foundation bolts. The
steel used for the manufacture of Pole shall comply with BSEN
with yield strength of 355 MP for Conical Pole shaft or equivalent and
the material for the base plate, bracket, flange plates, shall be
equivalent to or better than IS 2062. Hot Dip Galvanizing shall be in
accordance with IS 2629 or latest IS specification. The poles should
be Hot Dip Galvanized to give average thickness of galvanization as
per IS 4759/ BSEN 1461 standards – 65 microns.Test report to be
submitted by manufacturer. All components of the pole and brackets
shall be hot dip galvanized after completion of fabrication.No further
touching up finalizing or modification shall be done after galvanizing. no 65.00 43,700.00
The overall length of each section bracket is immersed in one dipping
operation to ensure smooth and aesthetic finish. No repetition
allowed. They shall be designed and fabricated from such material
and provided with such finish so as to withstand atmospheric
conditions.The poles are to be designed for maximum wind speed of
47 m/s (169 km /hr.) (IS 875 Part-III). The pole shall be evenly
tapered from base to top. The pole shall preferably be fabricated in
section. There shall be no circumferential welded joint in Poles. All
welds shall ensure no fissures inside or outside or outsides surfaces,
and no blowholes. Within the pole there must be Din rail Mounting
provision for MCB & Electrical Connector. Pole must be with 300m
single bracket arm as per shown in drawing. Make / As per approved
SITC of 4M Conical Bended Hot Dip Galvanized with PU Painted with
Top dia 70mm and Bottom Dia 118mm with pole thickness 3mm
along with Base plate 200mmx200mmx12mm with Single Arm
Bracket of 300mm with provision for 4 nos of foundation nut & bolt.
The steel used for the manufacture of Pole shall comply with BSEN
10025 with yield strength of 355 MP for Conical Pole shaft or
equivalent and the material for the base plate, bracket, flange plates,
shall be equivalent to or better than IS 2062. Hot Dip Galvanizing
shall be in accordance with IS 2629 or latest IS specification. The
poles should be Hot Dip Galvanized to give average thickness of
galvanization as per IS 4759/ BSEN 1461 standards –
microns.Test report to be submitted by manufacturer. All components
of the pole and brackets shall be hot dip galvanized after completion
of fabrication.No further touching up finalizing or modification shall be no 33.00 20,125.00
done after galvanizing. The overall length of each section bracket is
immersed in one dipping operation to ensure smooth and aesthetic
finish. No repetition allowed. They shall be designed and fabricated
from such material and provided with such finish so as to withstand
atmospheric conditions.The poles are to be designed for maximum
wind speed of 47 m/s (169 km /hr.) (IS 875 Part-III). The pole shall be
evenly tapered from base to top. The pole shall preferably be
fabricated in section. There shall be no circumferential welded joint in
Poles. All welds shall ensure no fissures inside or outside or outsides
surfaces, and no blowholes. Within the pole there must be Din rail
Mounting provision for MCB & Electrical Connector. Pole must be with
300m single bracket arm as per shown in drawing. Make / As per
approved make list.
ESTIMATE Page : 29 of
SITC of Decorative Pole of 4.2 M column structure with an aesthetic
curved designed single arm decorative bracket. The Pole Shaft
should be fabricated out of Steel tube of grade YST 240. Structurally
designed base plate of Steel Steel of grade E250 Conforming to IS
226/ IS 2062 should be welded with the pole shaft. The structure
should be completely hot-dip galvanized and surface finished with PU
paint. The pole should be of large section at the base with height of
2.7M made up of Tapered fabricated sheet as per IS 1079, welded
with pipe dia of 140mm through which one single ended branch
coming out with dia. 60mm. The base plate shall be of
370mmx370mmx16mm suitable for mounting on 4 nos foundation
bolts. The pole shall be made of Mild Steel with Hot Dip Galvanizing
coating including base plate as per ASTM A123. The pole shall be of
‘composite’ construction designed to withstand specified ‘dead load’
pertaining to the luminaire and its mounting accessories and ‘wind
load’ corresponding to a basic wind speed of 169 kmph without any
deformation or damage to the structure. The welding shall be of high
quality, carried out by qualified welders using approved welding
procedures and tested for its quality through NDT method, such as
DP Test. The pole shaft structure shall be hot dip galvanized through
single dip process as per ASTM A123 and minimum average coating
shall not be less than 65 microns. No mechanical operation, such as
welding, drilling, etc. should be carried out on the pole structure post
hot dip galvanizing. The poles shall have door of about 470 mm
length and shall be vandal resistance and shall be weather proof to
ensure safety of inside connection as approved by the Depts. The
door shall be flush with the exterior surface and shall have suitable
locking arrangement with provision for connectors, MCB, etc. (to be
supplied by others). Complete pole shall be treated with high quality
epoxy zinc primer and thereafter coated with environmentally stable
Polyurethane paint to minimum average DFT of 70 micronsMake / As
89 per approved make list.
SITC of Decorative Pole of 9M column structure with an aesthetic
curved designed Double arm decorative bracket. The Pole Shaft
should be fabricated out of Steel tube of grade YST 240. Structurally
designed base plate of Steel Steel of grade E250 Conforming to IS
226/ IS 2062 should be welded with the pole shaft. The structure
should be completely hot-dip galvanized and surface finished with PU
paint. The pole should be of large section at the base with height of
4M made up of Tapered fabricated sheet as per IS 1079, welded with
pipe dia of 165mm through which two single ended branch coming out
with dia. 76mm. The base plate shall be of 370mmx370mmx16mm
suitable for mounting on 4 nos foundation bolts. The pole shall be
made of Mild Steel with Hot Dip Galvanizing coating including base
plate as per ASTM A123. The pole shall be of ‘composite’
construction designed to withstand specified ‘dead load’ pertaining to
the luminaire and its mounting accessories and ‘wind load’
corresponding to a basic wind speed of 169 kmph without any
deformation or damage to the structure. The welding shall be of high
quality, carried out by qualified welders using approved welding
procedures and tested for its quality through NDT method, such as
DP Test. The pole shaft structure shall be hot dip galvanized through
single dip process as per ASTM A123 and minimum average coating
shall not be less than 65 microns. No mechanical operation, such as
welding, drilling, etc. should be carried out on the pole structure post
hot dip galvanizing. The poles shall have door of about 470 mm
length and shall be vandal resistance and shall be weather proof to
ensure safety of inside connection as approved by the Depts. The
door shall be flush with the exterior surfa ce and shall have suitable
locking arrangement with provision for connectors, MCB, etc. (to be
supplied by others). Complete pole shall be treated with high quality
epoxy zinc primer and thereafter coated with environmentally stable
Polyurethane paint to minimum average DFT of 70 microns.Make / As
90 per approved make list.
ESTIMATE Page : 30 of
SITC of 4 Mtr height Urban Street Light Pole Hot dip Galvanized and
PU painted having pipe size of 100x100 mm square pipe (as per
drawing) with thickness of 3 mm Pole shall be mounted on square
base plate 200*200 *12 mm thickness suitable for mounting on 4 nos
foundation bolts. The pole must have a provision of extended Single
Arm bracket of 500mm length with the provision of integrated IP66
luminaire protected with an IK08 rated polycarbonate lens and
separate control gear compartment. (Protected against 5 joules of
impact, equivalent to a 1.7kg object dropped from 300mm). Overall
System efficacy at 130Lm/W at 4000K CCT. Surge Protection
provided at 10kV for both Common and Differential mode. The Pole
Shaft should be fabricated out of Steel tube of grade YST
Structurally designed base plate of Steel of grade E250 Conforming to
IS 226/ IS 2062 should be welded with the pole shaft. The pole shall
be of ‘composite’ construction designed to withstand specified ‘dead
load’ pertaining to the luminaire and its mounting accessories and
‘wind load’ corresponding to a basic wind speed of 169 kmph without no 6.00 20,125.00
any deformation or damage to the structure. The welding shall be of
high quality, carried out by qualified welders using approved welding
procedures and tested for its quality through NDT method, such as
DP Test. The pole shaft structure shall be hot dip galvanized through
single dip process as per ASTM A123 and minimum average coating
shall not be less than 65 microns. No mechanical operation, such as
welding, drilling, etc. should be carried out on the pole structure post
hot dip galvanizing. The poles shall have door of about 250 mm
length and shall be vandal resistance and shall be weather proof to
ensure safety of inside connection as approved by the Depts. The
door shall be flush with the exterior surface and shall have suitable
locking arrangement with provision for connectors, MCB, etc. (to be
supplied by others). Complete pole shall be treated with high quality
epoxy zinc primer and thereafter coated with environmentally stable
Polyurethane paint to minimum average DFT of 70 microns in closed
91 paint booth chamber.Make / As per approved make list.
SITC of 9Mtr height Urban Street Light Pole Hot dip Galvanized and
PU painted having pipe size of 150x150 mm square pipe (as per
drawing) and Hot Dip Galvanization an LED fixture wattage rating of
90W to 120W. Pole shall be mounted on square base plate 300*300
*16 mm thickness suitable for mounting on 4 nos foundation bolts.
The pole must have a provision of extended Single Arm bracket of 1M
length with the provision of integrated IP66 luminaire protected with
an IK08 rated polycarbonate lens and separate control gear
compartment. Overall System efficacy at 110Lm/W at 4000K CCT.
Surge Protection provided at 10kV for both Common and Differential
mode. The Pole Shaft should be fabricated out of Steel tube of grade
YST 240. Structurally designed base plate of Steel Steel of grade
E250 Conforming to IS 226/ IS 2062 should be welded with the pole
shaft. The pole shall be of ‘composite’ construction designed to
withstand specified ‘dead load’ pertaining to the luminaire and its
mounting accessories and ‘wind load’ corresponding to a basic wind
speed of 169 kmph without any deformation or damage to the
structure. The welding shall be of high quality, carried out by qualified
welders using approved welding procedures and tested for its quality
through NDT method, such as DP Test. The pole shaft structure shall
be hot dip galvanized through single dip process as per ASTM A123
and minimum average coating shall not be less than 65 microns. No
mechanical operation, such as welding, drilling, etc. should be carried
out on the pole structure post hot dip galvanizing. The poles shall
have door of about 250 mm length and shall be vandal resistance and
shall be weather proof to ensure safety of inside connection as
approved by the Depts. The door shall be flush with the exterior
surface and shall have suitable locking arrangement with provision for
connectors, MCB, etc. (to be supplied by others). Complete pole shall
be treated with high quality epoxy zinc primer and thereafter coated
with environmentally stable Polyurethane paint to minimum average
DFT of 70 microns.Make / As per approved make list.
ESTIMATE Page : 31 of
SITC of 9Mtr height Urban Street Light Pole Hot dip Galvanized and
PU painted having pipe size of 150x150 mm square pipe (as per
drawing) with thickness of 3 mm and Hot Dip Galvanization an LED
fixture wattage rating of 90W to 120W. Pole shall be mounted on
square base plate 300*300 *16 mm thickness suitable for mounting
on 4 nos foundation bolts. The pole must have a provision of
extended Single Arm bracket of 1.25M length with the provision of
integrated IP66 luminaire protected with an IK08 rated polycarbonate
lens and separate control gear compartment. Overall System efficacy
at 130Lm/W at 4000K CCT. Surge Protection provided at 10kV for
both Common and Differential mode. The Pole Shaft should be
fabricated out of Steel tube of grade YST 240. Structurally designed
base plate of Steel of grade E250 Conforming to IS 226/ IS
should be welded with the pole shaft. The pole shall be of ‘composite’
construction designed to withstand specified ‘dead load’ pertaining to
the luminaire and its mounting accessories and ‘wind load’
corresponding to a basic wind speed of 169 kmph without any no 6.00 45,425.00
deformation or damage to the structure. The welding shall be of high
quality, carried out by qualified welders using approved welding
procedures and tested for its quality through NDT method, such as
DP Test. The pole shaft structure shall be hot dip galvanized through
single dip process as per ASTM A123 and minimum average coating
shall not be less than 65 microns. No mechanical operation, such as
welding, drilling, etc. should be carried out on the pole structure post
hot dip galvanizing. The poles shall have door of about 250 mm
length and shall be vandal resistance and shall be weather proof to
ensure safety of inside connection as approved by the Depts. The
door shall be flush with the exterior surface and shall have suitable
locking arrangement with provision for connectors, MCB, etc. (to be
supplied by others). Complete pole shall be treated with high quality
epoxy zinc primer and thereafter coated with environmentally stable
Polyurethane paint to minimum average DFT of 70 microns.Make / As
93 per approved make list.
SITC of Type-A, Any kind of 3 to 4.5 mtr ht. Post top lantern Pole (
94 With Basic Rate of Rs. 22500/-)
SITC of Type-B, Any kind of 5 to 5.9 mtr ht. Post top lantern Pole (
95 With Basic Rate of Rs. 30000/-)
SITC of Type-C, Any kind of 6 Mtr. Ht. to 7.9 Mtr. Ht. Decorative
96 Street Light Pole ( with Basic Rate of Rs.35000/-)
SITC of Type-D, Any kind of 8 Mtr. Ht. Decorative Street Light Pole (
97 with Basic Rate of Rs.40000/-)
SITC of Type-E, Any kind of 9 Mtr. Ht. to 12 Mtr. Ht. Decorative Street
98 Light Pole ( with Basic Rate of Rs.45000/-)
Any kind of 0.1 to 2Mtr. Decorative Single Arm Bracket ( with Basic
99 Rate of Rs.7500/-) however not limited to this only.
Any kind of 0.1 to 2Mtr. Decorative Double Arm Bracket ( with Basic
100 Rate of Rs.10000/-) however not limited to this only.
Any kind of 0.1 to 2Mtr. Decorative Three Arm Bracket ( with Basic
101 Rate of Rs.12000/-) however not limited to this only.
SITC of Smart pole as per the Drawings / Specification As per
102 approved make list.
SITC of cement concrete.for foundation or for concrete filling in 1:2:4
ratio with 20 to 25 mm stone metal duly plastered with necessary Cu.Mtr 1,870.00 5,077.00
103 curing for pole muffing or any other purpose.
SITC of TMT Bar FE 500/500D reinforcement for RCC work including
bending, binding and placing in position complete upto floor two level.
SITC of 0.1 to 2 Mtr G.I.bracket with 2 coat P.U. Paint with primer(Any
Arm Bracket as per architect design).
Note : Sample must be Approved from Client / Architect / Consultant
SITC of FRP/GRP arm bracket of having 15˚ arm with 50 mm OD
106 pipe *5 mm thk,1000mm long from pole centre (A) Single arm bracket
SITC of FRP/GRP arm bracket of having 15˚ arm with 50 mm OD
pipe *5 mm thk,1000mm long from pole centre no 65.00 2,390.00
107 (B) Double arm bracket
ESTIMATE Page : 32 of
Supplying & erecting approved make AMC press moulded composite
FRP. loop-in, loop-out approx. 2mm thick box complete with Bakelite
connector strip 5way(3P+N+E),DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements with mounting no 27.00 890.00
clamp with nuts, bolts & washers suitable for erection on pole with
cable clamps& earth bolt of following size of box.
(A) 300mm x 200mm x 100mm [deep]
SITC of electric insulating paint having quantity of paint suitable to
apply upto 6 feet on pole with 5 KV strength and following
specifications:
(Hig electric strength 55 kv/mm, stable upto 200 degree temprature, no 2,750.00 1,530.00
excellent puncture resistant, resistance to fire, excellent resestance to
UV radiation, tough & scratch resistant excellent resistant to
Total Amount of Street Light Pole & Bracket 59
Total Amount of Street Light Pole & Bracket 59
: Luminaries with all electrical accessories are prewired upto the
terminal block & mounted on a removable control gear module for
ease of maintenance. All electrical connections of the control gear
module with the rest of the luminaire should be easily maintainable.
Mounting options should be for pole top mounting
. Note : All Outdoor Fixture should be minimum IP66
Supply and installation of LED street light luminaire with system
power (20W)± 5% , Available in color temperature (4000K-5700K),
CRI>70, SDCM<3 , LEDs used have a life of 50,000 burning hrs. &
Lumen maintenance as per L70 with high power white LEDs wattage
of 3 Watt and above assembled on MCPCB. The Luminaire System
efficacy should be of ≥160LPW at 5700K / ≥150LPW at 4000K /
≥135LPW at 3000K. The fixture housing must be Made of ADC
PDC Aluminum housing for rapid thermal healing & Powder coated by
Corrosion resistant Nano coating technology. The luminaire PCB
Used for Making Light Engine should be Metal Core PCB made of
high grade Al 5052 with minimum 70 micron copper thickness &
W/mk thermal conductivity for better thermal maintenance for light
Engines. Luminaire must have a Ingress protection of IP66 and
Impact Resistance of IK08. The fixture should have an Injection
moulded special PC lens optics ensuring low glare & best in class
uniformity of >0.45. The luminaire must have Integral encapsulated
high efficiency electronic driver of efficiency > 85% having a
Aluminum extrusion construction with rated voltage of 140-270V,
power factor > 0.95, THD < 10%, with Inbuilt surge protection of 10KV
and upgraded with integrated IP67 protected SPD of 20KV/10KA
surge protection with all necessary safety protection like mis-wiring,
Over voltage, Short circuit, Reverse Polarity protection.
Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-
IES, LM 79, LM 80, & TTC certificates will be provided from NABL
accredited lab.
ESTIMATE Page : 33 of
Supply and installation of LED Street light luminaire with system
power (45W)± 5% , Available in color temperature (4000K-5700K)
CRI>70, SDCM<3 , LEDs used have a life of 50,000 burning hrs. &
Lumen maintenance as per L70 with high power white LEDs wattage
of 3 Watt and above assembled on MCPCB, efficiency more than
150 lm/w. The Luminaire System efficacy should be of >=135LPW. .
The Luminaire System efficacy should be of ≥160LPW at 5700K /
≥150LPW at 4000K / ≥135LPW at 3000K The fixture housing must be
Made of ADC 12 PDC Aluminium housing for rapid thermal healing &
Powder coated by Corrosion resistant Nano coating technology. The
luminaire PCB Used for Making Light Engine should be Metal Core
PCB made of high grade Al 5052 with minimum 70 micron copper
thickness & 2 W/mk thermal conductivity for better thermal
maintanance for light Engines. Luminaire must have a Ingress
protection of IP66 and Impact Resistance of IK08. The fixture should
have an Injection moulded special PC lens optics ensuring low glare
& best in class uniformity of >0.45. The luminaire must have Integral
encapsulated high efficiency electronic driver of efficiency > 85%
having a Aluminium extrusion construction with rated voltage of 140-
270V, power factor > 0.95, THD < 10%, with Inbuilt surge protection
of 10KV and upgraded with integrated IP67 protected SPD of
20KV/10KA surge protection with all necessary safety protection like
mis-wiring, Over voltage, Short circuit, Reverse Polarity protection.
Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-
IES, LM 79, LM 80, & TTC certificates will be provided from NABL
accredited lab.
112 Technical specifications as Above (#111) no. 33.00 3,312.00
Supply and installation of LED street light luminaire with system
power (60W)± 5% , Available in color temperature (3000K-5700K)
CRI>70, SDCM<3 , LEDs used have a life of 50,000 burning hrs. &
Lumen maintenance as per L70 with high power white LEDs wattage
of 3 Watt and above assembled on MCPCB. The Luminaire System
efficacy should be of ≥160LPW at 5700K / ≥150LPW at 4000K /
≥135LPW at 3000K. The fixture housing must be Made of ADC
PDC Aluminium housing for rapid thermal healing & Powder coated
by Corrosion resistant Nano coating technology. The luminaire PCB
Used for Making Light Engine should be Metal Core PCB made of
high grade Al 5052 with minimum 70 micron copper thickness &
W/mk thermal conductivity for better thermal maintanance for light
Engines.Luminaire must have a Ingress protection of IP66 and Impact
Resistance of IK08. The fixture should have an Injection moulded
special PC lens optics ensuring low glare & best in class uniformity of
>0.45. The luminaire must have Integral encapsulated high efficiency
electronic driver of efficiency > 85% having a Aluminium extrusion
construction with rated voltage of 140-270V, power factor > 0.95, THD
< 10%, with Inbuilt surge protection of 10KV and upgraded with
integrated IP67 protected SPD of 20KV/10KA surge protection with all
necessary safety protection like mis-wiring, Over voltage, Short
circuit, Reverse Polarity protection.
Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-
IES, LM 79, LM 80, & TTC certificates will be provided from NABL
accredited lab.
114 Technical specifications as Above (#113) no. 93.00 4,948.00
ESTIMATE Page : 34 of
Supply and installation of LED street light luminaire with Dimmable
Driver with system power (90W )± 5% , Available in color temperature
(3000K-5700K) , CRI>70, SDCM<3, LEDs used have a life of
burning hrs. & Lumen maintenance as per L90 with high power white
LEDs wattage of 3 Watt and above assembled on MCPCB. The
Luminaire System efficacy should be of ≥160LPW at 5700K /
≥150LPW at 4000K / ≥135LPW at 3000K. The fixture housing must
be Made of ADC 12 PDC Aluminum housing for rapid thermal healing
& Powder coated by Corrosion resistant Nano coating technology.
The luminaire PCB Used for Making Light Engine should be Metal
Core PCB made of high grade Al 5052 with minimum 70 micron
copper thickness & 2 W/mk thermal conductivity for better thermal
maintenance for light Engines. Luminaire must have a Ingress
protection of IP66 and Impact Resistance of IK08. The fixture should
have an Injection moulded special PC lens optics ensuring low glare
& best in class uniformity of >0.45. The luminaire must have Integral
encapsulated high efficiency electronic driver of efficiency > 85%
having a Aluminum extrusion construction with rated voltage of 140-
270V, power factor > 0.95, THD < 10%, with Inbuilt surge protection
of 10KV and upgraded with integrated IP67 protected SPD of
20KV/10KA surge protection with all necessary safety protection like
mis-wiring, Over voltage, Short circuit, Reverse Polarity protection.
Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-
IES, LM 79, LM 80, & TTC certificates will be provided from NABL
accredited lab.
116 Technical specifications as above (#115) no. 93.00 5,917.00
117 Supply and installation of LED street light luminaire with Dimmable
Driver with system power (120W)± 5% , Available in color
temperature (4000K-5700K) , CRI>70, SDCM<3 , LEDs used have a
life of 100,000 burning hrs. & Lumen maintenance as per L90 with
high power white LEDs wattage of 3 Watt and above assembled on
MCPCB. The Luminaire System efficacy should be of ≥160LPW at
5700K / ≥150LPW at 4000K / ≥135LPW at 3000K. The fixture housing
must be Made of ADC 12 PDC Aluminum housing for rapid thermal
healing & Powder coated by Corrosion resistant Nano coating
technology. The luminaire PCB Used for Making Light Engine should
be Metal Core PCB made of high grade Al 5052 with minimum
micron copper thickness & 2 W/mk thermal conductivity for better
thermal maintenance for light Engines. Luminaire must have a Ingress
protection of IP66 and Impact Resistance of IK08. The fixture should
have an Injection moulded special PC lens optics ensuring low glare
& best in class uniformity of >0.45. The luminaire must have Integral
encapsulated high efficiency electronic driver of efficiency > 85% no. 514.00 6,501.00
having a Aluminum extrusion construction with rated voltage of 140-
270V, power factor > 0.95, THD
< 10%, with Inbuilt surge protection of 10KV and upgraded with
integrated IP67 protected SPD of 20KV/10KA surge protection with all
necessary safety protection like mis-wiring, Over voltage, Short
circuit, Reverse Polarity protection.
Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-
IES, LM 79, LM 80, & TTC certificates will be provided from NABL
accredited lab.
118 Technical specifications as above (#117) no. 1,339.00 6,501.00
ESTIMATE Page : 35 of
Supply and installation of LED street light luminaire with Dimmable
Driver with system power (150W)± 5% , Available in color
temperature (3000K-5700K) ,CRI>70, SDCM<3 , LEDs used have a
life of 100,000 burning hrs. & Lumen maintenance as per L90 with
high power white LEDs wattage of 3 Watt and above assembled on
MCPCB. The Luminaire System efficacy should be of ≥160LPW at
5700K / ≥150LPW at 4000K / ≥135LPW at 3000K. The fixture housing
must be Made of ADC 12 PDC Aluminum housing for rapid thermal
healing & Powder coated by Corrosion resistant Nano coating
technology. The luminaire PCB Used for Making Light Engine should
be Metal Core PCB made of high grade Al 5052 with minimum
micron copper thickness & 2 W/mk thermal conductivity for better
thermal maintenance for light Engines. Luminaire must have a Ingress
protection of IP66 and Impact Resistance of IK08. The fixture should no. 129.00 7,798.00
have an Injection moulded special PC lens optics ensuring low glare
& best in class uniformity of >0.45. The luminaire must have Integral
encapsulated high efficiency electronic driver of efficiency > 85%
having a Aluminum extrusion construction with rated voltage of 140-
270V, power factor > 0.95, THD
< 10%, with Inbuilt surge protection of 10KV and upgraded with
integrated IP67 protected SPD of 20KV/10KA surge protection with all
necessary safety protection like mis-wiring, Over voltage, Short
circuit, Reverse Polarity protection.
Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-
IES, LM 79, LM 80, & TTC certificates will be provided from NABL
accredited lab..
120 Technical specifications as above (#119) no. 890.00 7,798.00
Supply and installation of LED street light luminaire with Dimmable
Driver with system power (170W)± 5% , Available in color
temperature (3000K-5700K) , CRI>70, SDCM<3 , LEDs used have a
life of 100,000 burning hrs. & Lumen maintenance as per L90 with
high power white LEDs wattage of 3 Watt and above assembled on
MCPCB. The Luminaire System efficacy should be of ≥160LPW at
5700K / ≥150LPW at 4000K / ≥135LPW at 3000K. The fixture housing
must be Made of ADC 12 PDC Aluminum housing for rapid thermal
healing & Powder coated by Corrosion resistant Nano coating
technology. The luminaire PCB Used for Making Light Engine should
be Metal Core PCB made of high grade Al 5052 with minimum
micron copper thickness & 2 W/mk thermal conductivity for better
thermal maintenance for light Engines. Luminaire must have a Ingress
protection of IP66 and Impact Resistance of IK08. The fixture should no. 129.00 9,018.00
have an Injection moulded special PC lens optics ensuring low glare
& best in class uniformity of >0.45. The luminaire must have Integral
encapsulated high efficiency electronic driver of efficiency > 85%
having a Aluminum extrusion construction with rated voltage of 140-
270V, power factor > 0.95, THD
< 10%, with Inbuilt surge protection of 10KV and upgraded with
integrated IP67 protected SPD of 20KV/10KA surge protection with all
necessary safety protection like mis-wiring, Over voltage, Short
circuit, Reverse Polarity protection.
Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-
IES, LM 79, LM 80, & TTC certificates will be provided from NABL
accredited lab.
122 Technical specifications as above (#121) no. 825.00 9,018.00
ESTIMATE Page : 36 of
Supply and installation of LED Flood light fittings with High power
White LEDs wattage of 3 Watt and above assembled on MCPCB,
corrosion free High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminum with diffuser
and Polycarbonate optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V, Power Factor more
than 0.95, THD < 10 %, CCT 4000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 145 lumens/watt . LED driver efficiency > 85 no. 93.00 7,195.00
%.( fittings required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.
The Engineer in charge may select any wattage capacity between the
(B) Flood Light (IP-66), Surge protection 10KV integral and, Light
must have 440VAC line supply with over-voltage protection.
(iii) above 90 watts Watts
Supply and installation of LED Flood light fittings with High power
White LEDs wattage of 3 Watt and above assembled on MCPCB,
corrosion free High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminum with diffuser
and Polycarbonate optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V, Power Factor more
than 0.95, THD < 10 %, CCT 4000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 145 lumens/watt . LED driver efficiency > 85 no. 93.00 8,370.00
%.( fittings required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.
The Engineer in charge may select any wattage capacity between the
(B) Flood Light (IP-66), Surge protection 10KV integral and, Light
must have 440VAC line supply with over-voltage protection.
(iv) above 120 watts
Supply and installation of LED Flood light fittings with High power
White LEDs wattage of 3 Watt and above assembled on MCPCB,
corrosion free High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power Factor more
than 0.95, THD < 10 %, CCT 4000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 145 lumens/watt . LED driver efficiency > 85 no. 93.00 9,552.00
%.( fittings required LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.
The Engineer incharge may select any wattage capacity between the
(B) Flood Light (IP-66), Surge protection 10KV integral and ,Light
must have 440VAC line supply with over-voltage protection.
(v) above 160 watts
ESTIMATE Page : 37 of
Supply and installation of LED Flood light fittings with High power
White LEDs wattage of 3 Watt and above assembled on MCPCB,
corrosion free High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminum with diffuser
and Polycarbonate optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V, Power Factor more
than 0.95, THD < 10 %, CCT 4000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 145 lumens/watt . LED driver efficiency > 85 no. 194.00 10,711.00
%.( fittings required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.
The Engineer in charge may select any wattage capacity between the
(B) Flood Light (IP-66), Surge protection 10KV integral and, Light
must have 440VAC line supply with over-voltage protection.
(vi) above 200 Watts
Supplying and erecting LED street light / Flood light fittings with High
power White LEDs wattage of 3 Watt and above assembled on
MCPCB, efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminum with diffuser and
Polycarbonate optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V, Power Factor more
than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.(
fittings required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.
The Engineer in charge may select any wattage capacity between the
(C) Post Top Lantern LED fitting comprises of finish cast aluminum
spigot and spun aluminum canopy fixed with opal polycarbonate, pipe
arrangement for vertical mounting driver and accessories wired upto
terminal block. IP
SITC of Type – A Any kind of Light fixture ( with Basic Rate of
SITC of Type – B Any kind of Light fixture ( with Basic Rate of
SITC of Type – C Any kind of Light fixture ( with Basic Rate of
SITC of Type – D Any kind of Light fixture ( with Basic Rate of
SITC of Type – E Any kind of Light fixture ( with Basic Rate of
SITC of Type – F Any kind of Light fixture ( with Basic Rate of
Total Amount of Light Fixtures 24
Total Amount of Light Fixtures 24
Plate Type Earthing
Supplying & erecting funnel type earthing having earth plate of
following size burred in specifically prepared earth pit 3 mtr. below
ground with 40 kg. charcoal and salt with alternate layers of charcoal
& salt, 20mm.dia. G.I. pipe with Funnel with a wire mesh for watering
& bricks masonry block, C.I. Cover complete as per para 7.3 of IS
3043 with necessary length of double Galvanised Iron / copper earth
wire No 6 SWG bolted with lug to the plate and covered in 12 mm dia.
G.I. pipe 2.5 mtr long complete connected to the nearest switch gear
with end socket as per direction & duly tested by earth tester
confirming to IS (As per drawing) with following specification
134 (C) with 60 x 60x 0.315 cms. Copper earth Plate no 4.00 7,797.00
135 (B) With 45 x 45 x 0.35 cms. G.I. earth plate no 6.00 2,543.00
Chemical Type Earthing -
ESTIMATE Page : 38 of
Supplying & erecting in earthpit of minimum bore dia. 225mm size
approved make Safe Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of Copper Pipes having Outer
pipe dia of 50mm having , Inner pipe dia of 40 mm , connection
terminal dia of 14 mm with constant ohmic value surrounded by
highly conductive compound with high charge dissipation suitable for
following type of applications.
(a) For Electrical Installation up to 440V in normal soil Length of pipe -
136 Back filling compound - 1 Nos Bag of 15 Kg.
(a) For Electrical Installation up to 440V in normal soil Length of pipe -
137 Back filling compound - 1 Nos Bag of 25 Kg.
Pipe type earthing with 40 mm dia 2.5 mtr long 'B' grade G.I. pipe with
necessary coupling buch buried in specially prepared earth pit & G.I. Ea. 2,887.00 815.00
earth wire of 8 SWG erected & connected as directed (For panel)
Earth wire/strips : -
Supply and laying required size Cu/GI. earthing strips for
interconnecting the earthing stations, panels, section piller etc. in built
up trenches, on walls/ceiling, buried in ground generally as specified
and shown on drawings complete with :
a) Fixing accessories.
b) Corrosion protection of buried conductors with bituminous coating
and covered with PVC tapes.
140 No.8 gauge bare cu. earth wire Kg. 219.00 787.00
Providing and erecting HOT deep Galvanised iron strip/ wire 8 to
Total Amount of Earthing
Total Amount of Earthing
Pole dismantling, carting and to submit at AMC store. ( 4 mtr to 10 mtr
The temporary illumination work
Providing of minimum of 10 nos. of LED Flood light minimum
Watt flood light and its temporary wiring in each job in existing road /
service road as per client requirement
Providing , erecting , fabricating the M.S. structure as per requirement
on site incorporating proper size of M.S. angles, flats, bars, channels,
pipes, sections, Sheets & for the pole swaging with the suitable dia
pipe complete with cutting, welding, grinding & finishing duly painted Kg 2,887.00 77.00
with two coat of redoxide with erection on site as per direction of
engineer in charge with necessary gouting, cementing, plastering &
finishing complete as per the instruction of the engineer incharge.
Total Amount of Miscellaneous
Total Amount of Miscellaneous
ESTIMATE Page : 39 of
Document : SECTION-C, CMS AND SECTION FEEDER PANEL WORK
Project : Street Light Work Ahmedabad
Client : Ahmedabad Municipal Corporation
Sr. No. Description Amount Rs.
2 New Section Feeder Panel
3 Upgradation Work of Existing Section Feeder Panel
ESTIMATE Page : 40 of
DESCRIPTION UNIT QTY
SITC of a Smart 4G Timer, Supply of lot based 4G Smart Streetlight
Control & Monitoring System having a Smart Panel comprising of 3 Phase
loT Streetlight Smart 4G Timer with 16x2 LCD to display RSSI, relay status,
RTC time & diagnostics.. Controller works on 3-phase & also on any
available 1-Phase., Controller with 8-hour battery backup during external
power failure. External power failure alert immediately to cloud., 110-630 V
AC @ 50-60 Hz 3 phase operating range., Standby power consumption
<3W., Smart 4G Timer with RS232 port for DLMS Energy meter., Smart 4G
Timer must be compatible with any make / brand of DLMS (RS232) Energy
Meter., DI: 4 Nos. (3 Contactor/Latch detection, 1 for Door Sensor.)., DO:
Relays for Independent control each phase (R. Y. B) with 1 extra spare
relay., Smart 4G Timer with dual SIM functionality for connectivity backup..
4G M2M SIM 3-Year communication included., Local configuration via WiFi
/BLE for maintenance or during force majeure., GPS chip inbuilt of Smart 4G
Timer for auto location tracking & astronomic schedule location.,
programmable schedules., Astronomic scheduling with monthly offsets..
Smart 4G Timer has inbuilt timer stores schedules locally & also stores
schedule execution logs locally, syncs to cloud whenever connected to
cloud., Auto-scheduler overrides manual operations.. Monitoring & alerts for
MCB trips.. Over/under voltage, current, overload, power factor & short
circuit protections with alerts via Dashboard, App, SMS, WhatsApp & Email.,
Contactor / Latch chattering protection & alerts., Smart 4G Timer with neutral
failure protection and alert., Bulit-in Watchdog for anti-jamming.. Smart 4G
Timer must send Regular "heartbeat" on software for CCMS status..
Accelerometer for tamper & panel movement detection & alerts.. Smart 4G
Timer must be tested from an NABL Lab for Surge Test @ 6 KV (IEC 61000-
Conducted Emission @ 150 KHz-30 MHz (CISPR11), Damp Heat Test (40
Deg C @ 95% RH) 2 cycles of 12+12 hours (IS: 9000 (Part 5/Sec.2):
latest) with all test passing criteria as "Temporary degradation or loss of
function or performance which is self-recoverable"., FOTA functionality
required for upgrades., Smart 4G Timer sends & stores online/offline data of
controller & load for lamp burn hours analysis..It stores & syncs connectivity
logs for configuration of network connections & analytics., CCMS SMART
SOFTWARE, OAuth 2.0 APIs for sending data to Government
clouds/software, etc., CCMS Web dashboard with secure password & OTP
login., Hosted on trusted cloud, data security, antivirus & attack protection.,
HTTPS., AES256-bit encryption., Vulnerability Assessment and Penetration
Testing (VAPT) certificate for CCMS Software., Streetlight management
software for load status, live analytics & reports., Energy meter data tables
(kW, kWh, PF, I, V, etc.) available., Utility monthly bill reconciliation & Class
1 accuracy reports for billing, energy monitoring & auditing for streetlight
load., Fault detection., Light fault 99% analysis on dashboard using energy
monitoring., WhatsApp integration., Hierarchy-wise reporting & alerts., GIS
mapping of live connected streetlight control panels, poles & streetlights.,
MQTT protocol., Smartphone app with local configuration & navigation.,
Monitoring & reporting of lighting parameters., Facility for media attachments
for site photos/videos/work permits/checklists, etc. per Feeder Panel for
remote verification., Asset management module for streetlight infrastructure
data., Complaint/service task management with history & escalation must be
available., Android & IOS App for dashboard analytics, graphs, energy data,
alerts., 3 Years CCMS Web Software & Cloud Server Hosting subscription
included.. Customizable, user-friendly dashboard..
SITC of PANEL & SWITCHGEAR, The panel made with 2 mm CRCA sheet
with ground mountable stand complete with gland plate, waterproof glands,
earthing bolt., IP55, weatherproof panel with RAL7035 powder-coated..
Smart 4G Timer must be fitted on removable terminal sockets for easy
maintenance.. Also, provide lock & key facility., Panel mount outdoor
antenna for GSM, GPS., Canopy design for draining down water
ESTIMATE Page : 41 of
DESCRIPTION UNIT QTY
SITC of Class 1 DLMS energy meter NABL approved with 1-2 months of
stored data of daily, hourly, monthly, load survey, instantaneous, events,
tamper data & with power events stored in meter memory for audit purpose.,
Must monitor V. I. KWH, KVA, PF. KVAH, etc.The solution must include
wiring, terminal connectors, DIN rail mounting arrangement, and proper
Supply, Installation, Testing and Commissioning (SITC) of a panel-mounted,
multi-circuit energy monitoring system for monitoring 6, 9, 12, or 18 or as per
site requirements outgoing circuits within feeder panels or distribution
boards. The system must enable real-time measurement and reporting of
power, energy, and circuit-level load status to enable efficient energy
management, fault detection, and operational optimization. should be in full
compliance with the requirements and configurations specified in the
detailed technical specifications section.
SITC of feeder panel accessory with switchgear includes 3 Nos. 3 pole
Contactor / Latch having minimum 50 A Load carrying capacity per phase,
5 all other switchgear & wires: 40 A load carrying capacity., 1 Nos. 4P MCB 10 Each 4,000 12,500
kA for Incomer & 6 Nos. 1P MCBs 10 kA for Outgoing.. Phase-Wise Bypass
MCBs required.. 4P RCCB 100 mA.,
ESTIMATE Page : 42 of
DESCRIPTION UNIT QTY
Software Licenses, Design, Development, Delivery and Hosting on Secure
Cloud, Street Light Smart Management Software as described; Secure
Database, Remote Controlling, Monitoring, Power metering features and
Reports Generation & Delivery; Local Language inclusion if needed, API
access and integration support to CMS/ SCADA system; 24 x 7 ticketing
system access; Advance User Rights Management to limit control per User,
Unlimited Users per Project/ Organization, Equipment Activation in LMS,
Local Training on Software platform, All types of Recurring Charges & All
Upgrades, O&M, Bug fixing, Security Updates for two years for
Cabinet Controllers and Outdoor Lamp Controllers. Hosting, Customization
and Delivery of Mobile and Web Applications for Smart Street Light
Management for field activity, maintenance crew, special access control,
event management as described; 24 x 7 ticketing system access; User
Rights Management, Unlimited Users per Project/ Organization, Equipment
Activation in LMS, Training on Mobile apps, All types of Recurring Charges &
All Upgrades, O&M, Bug fixing, Security Updates for Five years for
Cabinet Controllers and Outdoor Lamp Controllers. should be in full
compliance with the requirements and configurations specified in the
detailed technical specifications section.
The scope also includes Supply, Installation, Testing, and Commissioning
(SITC) of a web-based, centralized Helpdesk Software System for managing
service requests, complaints, maintenance calls, and issue tracking across
departments and field teams within the city’s command and control
operations. The system shall support multi-user and multi-role access with
6 configurable workflows, and provide a browser-accessible interface Each 1 3,00,00,000
compatible with desktop and mobile devices. The Helpdesk Software shall
include features such as ticket creation (manual and automated),
assignment, SLA-based escalation, resolution tracking, feedback capture,
and closure with audit trails. It must support multi-channel input including
web portal, email parsing, mobile app integration, and optionally WhatsApp
or SMS bot. The solution shall include a real-time dashboard for ticket
status, SLA compliance, and KPI monitoring, with exportable reports in
PDF/Excel formats. The system must allow user authentication via Role-
Based Access Control (RBAC) and optionally integrate with LDAP/Active
Directory. A searchable internal knowledge base, SOP/document upload
module, and complaint category-wise configuration shall be included. The
backend shall be developed on an open-source stack (Node.js/PHP/Python)
with a relational database (PostgreSQL/MySQL) hosted on a secure Linux-
based server (Ubuntu LTS or RHEL). The software must comply with
Government of India standards on data security, including SSL- encrypted
HTTPS access, OWASP-aligned input validation, and server hardening as
per CERT-In advisories. The system shall be capable of handling a minimum
of 10,000 tickets per month and 500 concurrent users, with automated
backup, restore, and recovery options. The SITC scope includes deployment
(on-premise or cloud), initial configuration, administrator and operator
training, user manual, mobile app (if applicable), SOP documentation, and 5-
year technical support with remote troubleshooting and software updates.
should be in full compliance with the requirements and configurations
specified in the detailed technical specifications section. The scope also
includes the integration of existing nodes through API
Hosting, Customization and Delivery of Mobile and Web Applications for
Smart Street Light Management for field activity, maintenance crew, special
access control, event management as described; 24 x 7 ticketing system
access; User Rights Management, Unlimited Users per Project/
7 Organization, Equipment Activation in LMS, Training on Mobile apps, All Each 1 1,00,00,000
types of Recurring Charges & All Upgrades, O&M, Bug fixing, Security
Updates for five years for 10,000 Cabinet Controllers and Outdoor Lamp
Controllers. should be in full compliance with the requirements and
configurations specified in the detailed technical specifications section.
SITC of Outdoor Lamp Controller / Individual Streetlight Controller (OLC)
with motion sensor based on wireless communication supplied with firmware
8 updates, bug fixes at no additional costs, and complete certifications. 5 year Each 15,000 6,500
standard warranty. should be in full compliance with the requirements and
configurations specified in the detailed technical specifications section.
ESTIMATE Page : 43 of
DESCRIPTION UNIT QTY
SITC of Pole-Mounted Nema-based Outdoor Lamp Controller / Individual
Streetlight Controller (OLC) for retrofitting old streetlight fixtures for wireless
communication supplied with complete with firmware updates, bug fixes at
no additional costs, and complete certifications. 5 year standard warranty.
should be in full compliance with the requirements and configurations
specified in the detailed technical specifications section.
SITC of high-quality, 5-core flexible cable with 2.5 sq.mm cross-sectional
area for power and control signal transmission between pole-mounted
luminaries and NEMA-based streetlight controllers. The cable shall ensure
safe, durable, and weather-resistant operation in outdoor environments,
conforming to relevant IS/IEC standards. Should have 5-core flexible cable,
2.5 sq.mm per core, Suitable for both power supply and signal
10 communication from NEMA controllers to luminaries, Insulated with high- Meter 1,50,000 78
grade PVC/XLPE compound for mechanical and thermal endurance, UV-
resistant, weatherproof and suitable for outdoor installations, Flame-
retardant and low-smoke emission type as per IS 694/IEC 60227, Operating
voltage: up to 1100V, Color-coded cores for easy identification, Compatible
with conduit or pole-mounted clamp installation, Minimum bending radius
and high flexibility for pole-top application
Supply, Installation, Testing, and Commissioning (SITC) of an enterprise-
grade, rack-mounted server system with disaster recovery setup in full
compliance with MeitY (Ministry of Electronics and Information Technology,
Government of India) guidelines for hosting centralized applications such as
Smart Infrastructure Management Software, SCADA, or Street Light
Management Platforms at the City Command Centre. The server shall be of
2U/4U industrial rack-mountable form factor, equipped with dual Intel Xeon
Silver/Gold or AMD EPYC processors with a minimum of 16 physical cores
in total, 128 GB ECC DDR4 RAM (expandable up to 512 GB), and storage
comprising 4 TB NVMe SSD configured in RAID 5 for OS and application
hosting, and 10 TB enterprise grade SATA HDD configured in RAID 6 for
local data archival. The system shall support 4 × 1 Gbps RJ45 and 2 ×
Gbps SFP+ Ethernet interfaces, redundant hot-swappable platinum-rated
power supplies, hardware RAID controller with battery backup unit (BBU),
and remote management capabilities via IPMI/BMC with web-based KVM.
The server shall come pre-installed with a MeitY-compliant operating system
(Ubuntu LTS / RHEL / Windows Server), hardened as per CERT-In security
advisories. A disaster recovery (DR) setup must be commissioned at a
geographically separated Tier III or higher data centre located within India,
ensuring real-time or near-real-time asynchronous data replication with an
RPO of ≤15 minutes and RTO of ≤1 hour. The DR setup shall include
minimum 5 TB usable replicated storage with secure transmission protocols
(SSL/TLS or AES-256 encrypted VPN tunnels), along with scheduled backup
policy (1 Full + 7 Incremental + Monthly Retention), DR drill capability (at
least twice a year), audit-ready SOPs, failover/failback procedures, and 24x7
monitoring dashboard for replication health.The scope shall also include an
online UPS system of minimum 2 kVA rating with ≥60 minutes backup time
using SMF/VRLA batteries, and a 16-port managed Layer 2/3 industrial
Ethernet switch with VLAN, QoS, SNMP support. All power/data/network
cables, connectors, rack-mount kits, documentation, testing tools, licenses (if
applicable), training for staff, and commissioning services shall be included
as part of the SITC deliverables. should be in full compliance with the
requirements and configurations specified in the detailed technical
specifications section.
ESTIMATE Page : 44 of
DESCRIPTION UNIT QTY
SITC of a desktop workstation for individual operators at the zone level. The
workstation must be suitable for operating the Street Light Management
Software and handling administrative and reporting tasks. It shall come pre-
installed with a licensed Windows Operating System, MS Office suite,
antivirus software, and necessary drivers. The system should have
appropriate processing power, RAM, and display resolution for multi-window
monitoring and data processing. should be in full compliance with the
requirements and configurations specified in the detailed technical
12 specifications section. Each 10 1,25,000
Intel® Core™ i7-12th generation, 4.0 GHz or higher, Minimum 32GB RAM,
Minimum 512 GB separate SSD hard drive for OS and 1TB HDD for Data,
DVD R/W, Graphics Adapter - Intel®IRIS XE Graphics or equivalent for local
client GPU rendering support, latest Windows professional OS (64-bit OS
versions recommended), Video Monitor Resolution- 1280x1024 pixels, 32 bit
with keyboard and mouse. with all required software like MS office, 5Year
antivirus etc..
SITC of of cellular / IoT data connectivity for smart streetlight controllers and
feeder-level equipment, enabling real-time communication with the central
LMS platform. The charges cover SIM card provisioning, activation, and
monthly data usage for device communication. The service must ensure
secure, uninterrupted data transmission with sufficient bandwidth and
fallback mechanisms as applicable. The recurring charges shall be paid in
the O&M section by the department on a monthly basis upon submission of
invoice and usage details.
SITC of of qualified and trained support staff from the OEM for on-site
operation, maintenance, and technical support at the Control Command
Centre. The deployment shall cover THREE shifts per day (24X7) to ensure
round-the-clock availability of personnel for managing the Street Light
Management Software, attending to alerts, coordinating with field teams, and Per
generating daily/weekly reports. The staff shall also assist in troubleshooting, Person
routine diagnostics, and training of municipal personnel as required.
Hour/Shift for 7 Days week, 3 Person for 60 months should be in full
compliance with the requirements and configurations specified in the
detailed technical specifications section.
CMS Work Total Amount
CMS Work Total Amount
Section Feeder Panels Type-A
ESTIMATE Page : 45 of
DESCRIPTION UNIT QTY
Supplying, unloading at site, shifting to site, assembling, leveling, grouting,
erecting, Testing, & Commissioning of Smart 4G Timer, Supply of lot based
4G Smart Streetlight Control & Monitoring System having a Smart Panel
comprising of 3 Phase loT Streetlight Smart 4G Timer with 16x2 LCD to
display RSSI, relay status, RTC time & diagnostics.. Controller works on 3-
phase & also on any available 1-Phase., Controller with 8-hour battery
backup during external power failure. External power failure alert
immediately to cloud., 110-630 V AC @ 50-60 Hz 3 phase operating range.,
Standby power consumption <3W., Smart 4G Timer with RS232 port for
DLMS Energy meter., Smart 4G Timer must be compatible with any make /
brand of DLMS (RS232) Energy Meter., DI: 4 Nos. (3 Contactor/Latch
detection, 1 for Door Sensor.)., DO: 3 Relays for Independent control each
phase (R. Y. B) with 1 extra spare relay., Smart 4G Timer with dual SIM
functionality for connectivity backup.. 4G M2M SIM 3-Year communication
included., Local configuration via WiFi /BLE for maintenance or during force
majeure., GPS chip inbuilt of Smart 4G Timer for auto location tracking &
astronomic schedule location., 50 programmable schedules., Astronomic
scheduling with monthly offsets.. Smart 4G Timer has inbuilt timer stores
schedules locally & also stores schedule execution logs locally, syncs to
cloud whenever connected to cloud., Auto-scheduler overrides manual
operations.. Monitoring & alerts for MCB trips.. Over/under voltage, current,
overload, power factor & short circuit protections with alerts via Dashboard,
App, SMS, WhatsApp & Email., Contactor / Latch chattering protection &
alerts., Smart 4G Timer with neutral failure protection and alert., Bulit-in
Watchdog for anti-jamming.. Smart 4G Timer must send Regular "heartbeat"
on software for CCMS status.. Accelerometer for tamper & panel movement
detection & alerts.. Smart 4G Timer must be tested from an NABL Lab for
Surge Test @ 6 KV (IEC 61000-4-5), ESD Test @ 4 KV (IEC 61000-4-2),
EFT @ 2 KV (IEC 61000-4-4), Conducted Emission @ 150 KHz-30 MHz
(CISPR11), Damp Heat Test (40 Deg C @ 95% RH) 2 cycles of 12+12 hours
(IS: 9000 (Part 5/Sec.2): 1981 latest) with all test passing criteria as
"Temporary degradation or loss of function or performance which is self-
recoverable"., FOTA functionality required for upgrades., Smart 4G Timer
sends & stores online/offline data of controller & load for lamp burn hours
15 analysis.. It stores & syncs connectivity logs for configuration of network no 1,085 1,00,000
connections & analytics., PANEL & SWITCHGEAR, The panel includes a
Class 1 DLMS energy meter NABL approved with 1-2 months of stored data
of daily, hourly, monthly, load survey, instantaneous, events, tamper data &
with power events stored in meter memory for audit purpose., Must monitor
V. I. KWH, KVA, PF. KVAH, etc.. Panel made with 2 mm CRCA sheet with
ground mountable stand complete with gland plate, waterproof glands,
earthing bolt., IP55, weatherproof panel with RAL7035 powder-coated..
Smart 4G Timer must be fitted on removable terminal sockets for easy
maintenance.. Switchgear includes 3 Nos. 3 pole Contactor / Latch having
minimum 50 A Load carrying capacity per phase, all other switchgear &
wires: 40 A load carrying capacity., 1 Nos. 4P MCB 10 kA for Incomer &
Nos. 1P MCBs 10 kA for Outgoing.. Phase-Wise Bypass MCBs required.. 4P
RCCB 100 mA., door sensor. Also, provide lock & key facility., Panel mount
outdoor antenna for GSM, GPS., Canopy design for draining down water.,
CCMS SMART SOFTWARE, OAuth 2.0 APIs for sending data to
Government clouds/software, etc., CCMS Web dashboard with secure
password & OTP login., Hosted on trusted cloud, data security, antivirus &
attack protection., HTTPS., AES256-bit encryption., Vulnerability
Assessment and Penetration Testing (VAPT) certificate for CCMS Software.,
Streetlight management software for load status, live analytics & reports.,
Energy meter data tables (kW, kWh, PF, I, V, etc.) available., Utility monthly
bill reconciliation & Class 1 accuracy reports for billing, energy monitoring &
auditing for streetlight load., Fault detection., Light fault 99% analysis on
dashboard using energy monitoring., WhatsApp integration., Hierarchy-wise
reporting & alerts., GIS mapping of live connected streetlight control panels,
poles & streetlights., MQTT protocol., Smartphone app with local
configuration & navigation., Monitoring & reporting of lighting parameters.,
Facility for media attachments for site photos/videos/work permits/checklists,
etc. per Feeder Panel for remote verification., Asset management module for
streetlight infrastructure data., Complaint/service task management with
history & escalation must be available., Android & IOS App for dashboard
analytics, graphs, energy data, alerts., 3 Years CCMS Web Software &
Cloud Server Hosting subscription included.. Customizable, user-friendly
Section Feeder Panels Type-B
ESTIMATE Page : 46 of
DESCRIPTION UNIT QTY
SITC of , unloading at site, shifting to site, assembling, leveling, grouting,
erecting, Testing, & Commissioning of Smart 4G Timer, Supply of lot based
4G Smart Streetlight Control & Monitoring System having a Smart Panel
comprising of 3 Phase loT Streetlight Smart 4G Timer with 16x2 LCD to
display RSSI, relay status, RTC time & diagnostics.. Controller works on 3-
phase & also on any available 1-Phase., Controller with 8-hour battery
backup during external power failure. External power failure alert
immediately to cloud., 110-630 V AC @ 50-60 Hz 3 phase operating range.,
Standby power consumption <3W., Smart 4G Timer with RS232 port for
DLMS Energy meter., Smart 4G Timer must be compatible with any make /
brand of DLMS (RS232) Energy Meter., DI: 4 Nos. (3 Contactor/Latch
detection, 1 for Door Sensor.)., DO: 3 Relays for Independent control each
phase (R. Y. B) with 1 extra spare relay., Smart 4G Timer with dual SIM
functionality for connectivity backup.. 4G M2M SIM 3-Year communication
included., Local configuration via WiFi /BLE for maintenance or during force
majeure., GPS chip inbuilt of Smart 4G Timer for auto location tracking &
astronomic schedule location., 50 programmable schedules., Astronomic
scheduling with monthly offsets.. Smart 4G Timer has inbuilt timer stores
schedules locally & also stores schedule execution logs locally, syncs to
cloud whenever connected to cloud., Auto-scheduler overrides manual
operations.. Monitoring & alerts for MCB trips.. Over/under voltage, current,
overload, power factor & short circuit protections with alerts via Dashboard,
App, SMS, WhatsApp & Email., Contactor / Latch chattering protection &
alerts., Smart 4G Timer with neutral failure protection and alert., Bulit-in
Watchdog for anti-jamming.. Smart 4G Timer must send Regular "heartbeat"
on software for CCMS status.. Accelerometer for tamper & panel movement
detection & alerts.. Smart 4G Timer must be tested from an NABL Lab for
Surge Test @ 6 KV (IEC 61000-4-5), ESD Test @ 4 KV (IEC 61000-4-2),
EFT @ 2 KV (IEC 61000-4-4), Conducted Emission @ 150 KHz-30 MHz
(CISPR11), Damp Heat Test (40 Deg C @ 95% RH) 2 cycles of 12+12 hours
(IS: 9000 (Part 5/Sec.2): 1981 latest) with all test passing criteria as
"Temporary degradation or loss of function or performance which is self-
recoverable"., FOTA functionality required for upgrades., Smart 4G Timer
sends & stores online/offline data of controller & load for lamp burn hours
16 analysis.. It stores & syncs connectivity logs for configuration of network no 725 85,000
connections & analytics., PANEL & SWITCHGEAR, The panel includes a
Class 1 DLMS energy meter NABL approved with 1-2 months of stored data
of daily, hourly, monthly, load survey, instantaneous, events, tamper data &
with power events stored in meter memory for audit purpose., Must monitor
V. I. KWH, KVA, PF. KVAH, etc.. Panel made with 2 mm CRCA sheet with
ground mountable stand complete with gland plate, waterproof glands,
earthing bolt., IP55, weatherproof panel with RAL7035 powder-coated..
Smart 4G Timer must be fitted on removable terminal sockets for easy
maintenance.. Switchgear includes 3 Nos. 3 pole Contactor / Latch having
minimum 50 A Load carrying capacity per phase, all other switchgear &
wires: 40 A load carrying capacity., 1 Nos. 4P MCB 10 kA for Incomer &
Nos. 1P MCBs 10 kA for Outgoing.. Phase-Wise Bypass MCBs required.. 4P
RCCB 100 mA., door sensor. Also, provide lock & key facility., Panel mount
outdoor antenna for GSM, GPS., Canopy design for draining down water.,
CCMS SMART SOFTWARE, OAuth 2.0 APIs for sending data to
Government clouds/software, etc., CCMS Web dashboard with secure
password & OTP login., Hosted on trusted cloud, data security, antivirus &
attack protection., HTTPS., AES256-bit encryption., Vulnerability
Assessment and Penetration Testing (VAPT) certificate for CCMS Software.,
Streetlight management software for load status, live analytics & reports.,
Energy meter data tables (kW, kWh, PF, I, V, etc.) available., Utility monthly
bill reconciliation & Class 1 accuracy reports for billing, energy monitoring &
auditing for streetlight load., Fault detection., Light fault 99% analysis on
dashboard using energy monitoring., WhatsApp integration., Hierarchy-wise
reporting & alerts., GIS mapping of live connected streetlight control panels,
poles & streetlights., MQTT protocol., Smartphone app with local
configuration & navigation., Monitoring & reporting of lighting parameters.,
Facility for media attachments for site photos/videos/work permits/checklists,
etc. per Feeder Panel for remote verification., Asset management module for
streetlight infrastructure data., Complaint/service task management with
history & escalation must be available., Android & IOS App for dashboard
analytics, graphs, energy data, alerts., 3 Years CCMS Web Software &
Cloud Server Hosting subscription included.. Customizable, user-friendly
New Section Feeder Panel Work
ESTIMATE Page : 47 of
DESCRIPTION UNIT QTY
Removing of Section Feeder Panel
Dismantling and removing of existing section feeder pillar as said location by
engineer in charge complete in all respect as it is original with necessary civil
work foundation, cable termination, with extra required various sizes cables
& with cable joints if needed etc. as per requirement or as per instruction of
engineer in charge.
Installation of Section Feeder Panel
Installation Testing and Commissioning of New / existing section feeder pillar
as said location by engineer in charge complete in all respect as it is original
with necessary cable termination, with extra required various sizes cables &
with cable joints if needed etc. as per requirement or as per instruction of
engineer in charge.
Upgradation of Section Feeder Panel
Upgradation of existing section feeder pillar Install MCB instead of Fuse as
said location by engineer in charge complete in all respect as it is original
with necessary cable termination, with extra required various sizes cables &
with cable joints if needed etc. as per requirement or as per instruction of
engineer in charge.
SITC of the MCB's ( 10 KA ) Timers , & Contactors With the Dinrail Channel
20 providing and erecting Miniature circuit breaker single pole 0.5A to 2A no 14,225 268
system and having breaking capacity 10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI Mark
Miniature circuit breaker single pole suitable to operate on 240 V A.C.
21 system and having breaking capacity 10 KA to be erected in existing box. no 6,000 111
confirming to IS 8828/1996 with ISI Mark 6 to 25 A SP MCB
Providing & erecting 240 V MCB double pole switch for motor & inductive
22 load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in no 1,000 297
existing box having following capacity 6 to 32 A DP MCB
Approved make ELCBs / RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable
for operation on single phase 240 V. having characteristic of quick action &
tripping with all advance feature & do not incorporate any electronic
component. for following Max. rating erected as directed 25 to 32A /
30mA/100 mA DP ELMCB
24 40 A / 100 mA DP ELMCB no 7 2,213
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C
25 Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box no 103 522
having following capacity (a) 6 to 32 Amp. Cat.III
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C
26 Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box no 6 641
having following capacity (b) 40 Amp. Cat.III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C
27 Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box no 500 730
having following capacity 63A FP MCB
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C
28 Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box no 500 662
having following capacity 40A FP MCB
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C
29 Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box no 150 590
having following capacity 6 to 32A FP MCB
Supplying & erecting power contactor for time switch complete erected as
per direction Cat III [B] 2 pole 250V 32 Amp.
Supplying & erecting power contactor for time switch complete erected as
per direction Cat III [D] 4 pole 440V 40 Amp.
ESTIMATE Page : 48 of
DESCRIPTION UNIT QTY
Supplying & erecting approved make Digital time switch having lithium cell
years operative and operate battery backup 1 channel day clock with
memory programme, suitable to operate on 240V + 5%, 16A with, floating
32 contacts Minimum switching setup time 1 minimum & LCD display. Also no 1,000 3,137
comprised permanent ON/OFF switching. Programming switches & housed
in fire proof thermoplastic enclosure & transparent cover erected as required
with necessary connection erected as directed.
Upgradation Amount for Section Feeder Panel
ESTIMATE Page : 49 of
Document : SECTION-D, AI WORK
Project : Street Light Work Ahmedabad
Client : Ahmedabad Municipal Corporation
Sr. No. Description Amount Rs.
ESTIMATE Page : 50 of
DESCRIPTION UNIT QTY
AI Engine Infrastructure Platform
Supply, Installation, Testing, and Commissioning of the complete on- premises
1 hardware and foundational software stack. This platform is designed as a high- Set - - -
availability cluster to provide the resilient and high- performance computational
power required for all specified AI functionalities, including future-readiness for
large-scale (70B+ parameter) AI models.
Inference Servers (High Availability Pair): For real-time processing of all AI
1.1 models. Each of the two servers to be equipped with 2x NVIDIA H200 80GB Set 1 1,68,72,400
GPUs (NVLink), 1.5 TB DDR5 RAM, 32-64 core CPU (AMD EPYC/Intel Xeon),
and 2 TB NVMe SSD.
AI Model Training Servers (High Availability Pair): A dedicated HA cluster for
1.2 the periodic offline retraining of all AI models. Each of the two servers to be Set 1 2,18,26,800
equipped with 2x NVIDIA H200 80GB GPUs (NVLink), 2 TB DDR5 RAM, 64-
core CPU, and 8 TB NVMe SSD.
Database Servers (High Availability Pair): A High Availability (1+1) cluster for
1.3 structured data storage. Each node to have a 32-core CPU, 512 GB RAM, and 1 98,68,200
High-Speed NAS Storage: For storing historical logs, datasets, and AI model
1.4 checkpoints. 50 TB high-performance SSD-based storage (RAID 10) with 10- Nos 1 86,74,600
25 GbE uplinks.
Monitoring, Logging & Load Balancing Servers (HA Pair): A High Availability
1.5 (1+1) cluster for system monitoring (Prometheus, Grafana), logging, and Set 1 78,62,860
request distribution.
1.6 High-Speed Network Switches (HA Pair): A High Availability (1+1) pair of 25- 40 Set 1 48,62,800
GbE Managed Switches with VLAN Support for low-latency connectivity.
Security Appliances (Firewall HA Cluster): A High Availability cluster of Next-
1.7 Generation Firewalls with DDoS & SSL inspection to protect all system Set 1 82,96,480
Core Platform & Virtualization Software Licenses: Includes all necessary OS,
1.8 virtualization, and container platform licenses to operate the entire hardware L.S 1 2,28,46,800
cluster as a unified, resilient private cloud.
LMS AI Software Platform
Supply of all proprietary application software required to operate the AI
Analytics and Optimization Engine. The software platform must grant the right
to use the specified modules across the entire network of assets and support
the high-availability hardware cluster.
Core AI Engine Components
2.1 Foundational software components responsible for data processing, real- time L.S - - -
analysis, and model deployment, forming the backend "brain" of the entire
Data Ingestion & ETL Platform: Core component for scalable intake of telemetry
2.1.1 from 207,000+ endpoints, performing data cleaning, transformation, and L.S 1 2,96,78,400
preparation for storage and analysis.
Real-time Stream Processing Engine: Core engine for analyzing data streams
2.1.2 in motion, enabling immediate alerts and actions for dynamic control and fault L.S 1 2,84,82,600
AI Model Serving & Inference Engine: Core runtime engine responsible for
2.1.3 deploying, managing, and serving predictions from all trained AI models with L.S 1 2,92,46,800
2.2 AI Application Model Packs L.S - - -
2.2.1 Predictive Failure AI Models Pack: The trained models (e.g., Gradient Boosting, L.S 1 1,94,64,600
LSTMs) for predicting failures in luminaires, drivers, and controllers
Power Grid Anomaly & Theft Detection AI Models Pack: The trained models
2.2.2 (e.g., Isolation Forests, Autoencoders) for identifying anomalies in power quality L.S 1 1,86,75,400
2.2.3 Energy Forecasting AI Models Pack: The trained time-series models (e.g., L.S 1 1,94,67,200
ARIMA, Prophet) for predicting energy consumption.
ESTIMATE Page : 51 of
DESCRIPTION UNIT QTY
2.2.4 Adaptive Lighting Data Fusion AI Models Pack: The trained models for fusing L.S 1 1,87,68,480
traffic, weather, and event data to create dynamic lighting profiles.
2.2.5 NLP & Sentiment Analysis AI Models Pack: The trained NLP models (e.g., L.S 1 1,98,76,860
BERT-based classifiers) for citizen feedback classification and analysis.
Application & Visualization Suites
2.3 The user-facing software components (dashboards, control panels, and L.S - - -
reporting tools) that allow operators to interact with and manage the insights
generated by the AI engines.
Predictive Maintenance & Asset Health Suite: The dashboard for maintenance
2.3.1 teams to visualize asset health scores, RUL estimates, and a map-based view L.S 1 1,18,67,500
of predicted faults.
Dynamic Lighting & Scene Management Suite: The control panel for lighting
2.3.2 operators to create, manage, and deploy dynamic lighting profiles L.S 1 98,76,400
recommended by the AI.
Energy Analytics & Optimization Suite: The dashboard for energy managers to
2.3.3 visualize consumption trends, forecasts, and potential savings identified by the L.S 1 92,97,520
analytics engine.
Citizen Service & Helpdesk Integration Suite: The interface for helpdesk teams
2.3.4 to view and manage auto-classified and prioritized tickets generated by the NLP L.S 1 85,84,200
Geospatial Intelligence & Reporting Suite: The reporting tool for exporting
2.3.5 aggregated data like traffic heatmaps and fault concentration maps for use in L.S 1 96,76,800
external GIS and urban planning software.
3 Professional & Operational Services L.S - - -
One-Time Implementation & Setup Services
3.1 Covers all one-time professional services required to successfully deploy, L.S - - -
configure, integrate the AI Engine, and train the initial models to ensure the
system is ready for operation.
Infrastructure Deployment & Integration: Covers the complete physical
3.1.1 deployment, logical configuration of the HA cluster, and integration with existing L.S 1 1,68,74,000
city data sources.
Initial AI Model Training & Calibration: Covers the professional data science
3.1.2 services for the first cycle of data ingestion, training, and calibration of all L.S 1 2,96,46,800
specified AI models to establish a baseline performance.
Yearly Operations & Management Services - After Successful Implementation
4 Covers all recurring services required to operate, maintain, and support the AI L.S - - -
Engine platform annually. The quantity reflects a 5-year operational period.
Annual Hardware Maintenance Contract (AMC): Comprehensive on-site
4.1 support, spares, and maintenance for all hardware components listed in Section L.S 5 60,00,000
Annual Software Platform & Application Support: Covers updates, security
4.2 patches, and technical support for all software listed in Section 14.8 and L.S 5 60,00,000
AI Model Monitoring, Retraining & Optimisation Services: Professional data
science services for continuous monitoring of model performance, periodic
retraining with new data, and optimisation of AI algorithms. Including Man
Managed Security & Infrastructure Operations: 24/7 monitoring of the platform
4.4 for security threats, performance bottlenecks, and operational management of L.S 60 4,00,000
the HA infrastructure. Including Man Power
ESTIMATE Page : 52 of
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
4.5m Street light pole 1.pdf
5.5m Street light pole 1.pdf
7.0m Street light pole 1.pdf
9.5m Street light pole 1.pdf
A TYPE 3 PHASE SECTION PILLER 1.pdf
B TYPE SECTION PILLAR 1.pdf
B2 TYPE SECTION PILLAR 1.pdf
SECTION CIRCUIT DIAGRAM 1.pdf
Volume - I Technical_Bid_Eastern Side_to be uploaded.pdf
Volume - II Technical_Specifications_Eastern Side_to be uploaded.pdf
Volume III Price Bid East Side FINAL_April 10 2026.pdf
Download all tender documents and submit your bid