Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.3 LAccepted-AOC H NO 255 SEC 11 PANCHKULA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L-1 | Accepted-AOC Lowest |
Tender Value
₹12.7 L
EMD Value
₹25,380
Closing Date
26 Apr 2021, 5:00 pmClosed
Lalit Mohan Jindal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Upgradation of PHC Nanakpur to CHC in Panchkula Distt. (Pdg. Internal EI) (Recall).
2021_HRY_163013_2
PWD/Elect-KNL/Elect-AMB/110148
Open Tender
Construction Works
Works
365 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹25,380
18 Jun 2021
12 Apr 2021
27 Apr 2021
12 Apr 2021
26 Apr 2021
12 Apr 2021
Amount
1:- ( c ) Moulded case Circuit breakers. Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 15 Amp..to 60 Amp.. 415 V ,10 KA 3-phase. 31.12 c (i)
2:- Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 40 mm x 40 mm x 6 mm. 31.13(ii)
3:- M.S.Sheet . Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide. 31.14 ( i )
4:- Blanking sheet . Supply and erection of blanking sheet in existing distribution board. 31.16 (i)
5:- (L) Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SP MCB of 9 KA breaking capacity 6 Amp.. to 32 Amp.. 31.17a) (ii)
:- SPN MCB of 9 KA breaking capacity 6 Amp.. To 32 Amp.. 31.17(a) (ii)
:- TPN MCB of 9 KA breaking capacity 40 Amp.. to 63 Amp.. 31.17(a) (iii)
6:- (M) Supply and erection of Fittings and Accessories. Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point. 31.18 (xxiv)
:- Bakelite angle / straight button holder large size. 31.18 (xi)
:- Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job. . 31.18 (xxvi)
7:- (O) Erection and carriage of fans.. Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work. 31.20 (i)
:- Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work. 31.20 (iii)
8:- (P) Pipe Laying. Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed. 31.21 (xxi)
:- Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed. 31.21 (xxii)
9:- (Q) Earthing Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. 31.22(iii)
:- Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. 31.22(v)
:- Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required . 31.22(xi)
:- Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material. 31.22(xv)
10:- Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 25 Sq. mm 4 Core Armoured Cable. 31.26 (xIi)
:- 35 Sq. mm 3.5 Core Armoured Cable. 31.26 (xxvi)
11:- Supply and erection of suitable compression type brass cable glands for underground Cable. 25 Sqmm to 50 Sqmm Cable 2 to 4 Core. 31.28 (iii)
12:- (X) Miscellaneous . Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm . 31.35 (ix) (c)
:- 25 sqmm . 31.35 (ix) (e)
:- 35 sqmm . 31.35 (ix) (f)
13:- (A) PVC Insulated wiring in recessed conduit. Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe. Fan Point - Medium . 31.36
:- Fan Point- Long. 31.36
:- Light point -Short. 31.36 (ii)
:- Light Point - Medium. 31.36
:- Light Point- Long. 31.36
:- Twin control light point with 2 way 5 Amp.. single pole switch-Short point. 31.36 (iii) a
:- Twin control light point with 2 way 5 Amp.. single pole switch-Long point. 31.36 (iii) c
:- Call bell point including M.S Box of size 180mmx100mmx60mm deep for call bell - Long point 31.36 (vi) c
:- 3 pin 5 Amp.. plug point including earthing the 3rd. pin etc. -Short point. 31.36 (vii) a
:- 3 pin 5 Amp. plug point including earthing the 3rd. pin etc. - Medium point. 31.36 (vii) b
:- 3 pin 5 Amp.. plug point including earthing the 3rd. pin etc.- Long point. 31.36 (vii) c
:- 3 pin 15 Amp. plug point including earthing the 3 rd. pin etc.with 4 sq mm PVC insulated copper conductor cable - Long point. 31.36 (viii) c
14:- Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Size 1.5 sqmm (3 / 0.81mm). 31.40 (i)
:- Size 2.50 sqmm (3 / 1.05mm). 31.40 (ii)
:- Size 4 sqmm (7 / 0.85mm). 31.40 (iii)
:- Size 10 sqmm 31.40 (v)
15:- Supply and erection of double door sheet steel enclosures distribution boards suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material requared complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work. 8-way, TP & N (Horizontal) (8+24) 31.41 (v)
:- 8-way, SP & N (Horizontal) 31.41 (ii)
16:- Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. 25 mm dia 31.44(b)
17:- Supply and erection of MS sadles and clAmp.s on wall / RCC parapit for fixing underground cable at distance of 0.60 metre centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect. 31.48
18:- S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 Mtr. Below ground level including digging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in charge of work. HDPE 63/50 mm outer dia / inner dia 31.67 ( i )
19:- S/E of Enclosure for 100/63Amp. MCCB with all Labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. NS-1
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .