Loading…
Loading…
Tender Value
₹98.6 L
EMD Value
₹99,000
Closing Date
30 Jun 2026, 6:00 pm3d left
Similar tender results from the same govt authority in the past 3 years.
Executive Engineer, District R and B Division, Vadodara
Package: Construction of New Animal Husbandary Epic Center at (1) Sarsavani (2) Latipura and (3) Mujpur, Ta. Padra, Dist. Vadodara (Deposit Work) (2nd Attempt)
316697
04 of 2026-2027
Open
Civil - All
Vadodara
8 documents required · 7 mandatory · 1 optional
₹2,400
Executive Engineer, District (R and B) Division, Vadodara
₹99,000
22 Jun 2026
22 Jun 2026
22 Jun 2026
30 Jun 2026
22 Jun 2026
Name of Work: Package: Construction of New Animal Husbandary Epic Center at (1) Sarsavani
(2) Latipura and (3) Mujpur, Ta. Padra, Dist. Vadodara (Deposit Work)
BILL OF QUANTITIES
It. No. Description of Item Quantity Unit Rate in Figure Total
1 Excavation for foundation upto 1.5 m depth including sorting out 854.89 Cu.mt 250.90
and stacking of useful materials and disposing off the excavated
stuff upto any lead. (B) Dense or Hard soil
2 Excavation for foundation for depth from 1.5 m to 3.0 m including 162.78 Cu.mt 289.92
sorting out and stacking of useful materials and disposing off the
excavated stuff upto any lead. (B) Dense or Hard soil
3 Providing and laying cement concrete work 1:2:4 (1- Cement : 2- 112.50 Cu.mt 4135.13
Coarse sand : 4- graded stone aggregates 20 mm nominal size)
and curing complete Including cost of formwork But Excluding The
Cost Of reinforcement for reinforced concrete work in (A)
Foundations, footings, Base or columns and Mass concrete . (For
4 Providing and laying controlled cement concrete M.250 and curing 54.37 Cu.mt 4642.97
complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in (A) Foundations,
footings, Base of columns and Mass concrete. (For Footing)
5 Providing and laying controlled c.c. M.250 & curing complete 12.21 Cu.mt 7742.66
including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Collumns, pillars,
posts & struts upto floor two level for G.F. (For Column Up to PL)
6 Providing and laying controlled cement concrete M.250 and curing 33.47 Cu.mt 5875.17
complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in (C) Slabs, landing,
shelves, Balconies, Lintels, Beams, Girders and Cantilever upto
floor two level.(For Ground Beam)
7 Filling available excavated earth (Excluding rock) in trenches plinth, 814.95 Cu.mt 133.65
sides of foundation etc in layers not exceeding 20 cm in depth
consolidating each deposited layer by ramming and watering.
8 Filling in foundation and plinth with murrum or selected soil in layers 42.99 Cu.mt 296.29
of 20cm. thickness including watering, ramming and consolidating
9 Filling in plinth with sand under floors including watering, ramming 11.37 Cu.mt 471.69
consolidating and dressing etc. complete.
10 Anti-Termite System:Providing and laying of permanent piping 227.49 Sq.mt 134.33
technology anti-termite treatment before flooring work by installing
LLDP (Low linear density polyethylene) tube of 8 mm O.D. &
mm 1.D. with inbuilt pressure compensation chip every 30 cm
interval in the tube, having working pressure of 2 Kg/cm2 and
release rate of 1.9 Itr/hour fixed by P-clips and nails. The LLDP pipe
shall be installed at the entire periphery of the building and at
internal network of building at a depth of 20 to 200 mm under floor
at every 2 to 3 mtr. c/c distance (adjusted as per building layout ) &
Ends of loop pass through a PVC elbow of minimum 32 mm ID at
junction box of wall and floor level, entering into a steel reinforced
grooved flexible pipe of minimum 22 mm ID leading into junction
box and the loops shall terminate in junction boxes & test every
junction during injecting chemicals for termite control treatment. The
anti termite chemical Imidacloprid 30.5% SC mix as per IS-6313
(part III) shall be injected by the pressure pump diluted with water @
10.5 ml/5 ltr of water at the rate of 2 Kg/sq.cm @ 5 Ltr/SMT. The
contractor shall submit approved line plan for piping system and
junction boxes dully approved by Engineer-in-Charge with bond of
year warranty.(i)Anti Termite chemical injected area (Chemical
injecting incl. labour cost)
11 Providing and laying damp proof course 25mm thick cement 35.04 Sq.mt 304.53
concrete 1:2:4 (1-Cement : 2 coarse sand : 4 stone aggregate
mm nominal size) and curing complete.
It. No. Description of Item Quantity Unit Rate in Figure Total
12 Brick work using common burnt clay building bricks having crushing 15.12 Cu.mt 4121.55
strength not less than 35 kg./Sq.Cm. in foundation and plinth in
Cement Mortar 1:6 (1- Cement : 6 -fine sand)(B) Conventiona( For
B/w Up to Plinth)
13 Brick work using Common burnt clay building bricks having 127.05 Cu.mt 4396.56
crushing strength not less than 35 kg/sq.cm in Super Structure
above floor Two Level in cement mortar 1:6 ( 1 cement : 6 fine sand
) (B) Conventional.( For B/W Uo to GF Slab)
14 Half brick masonry in common brunt clay building bricks having 36.99 Sq.mt 667.96
crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4
(1- Cement : 4 -coarse sand ) in Superstructure above plinth level
up to floor two Level(B) Conventional
15 Providing and laying cement concrete 1:3:6 (1- Cement : 3- Coarse 12.38 Cu.mt 3993.11
sand : 6- crushed stone aggregates 20 mm nominal size) and
curing complete including cost of formwork in (A) Wall Caps /
16 Providing and laying controlled cement concrete M.200 and curing 8.97 Cu.mt 7230.59
complete excluding the cost of formwork and reinforcement for
reinforced concrete work in (C) Slabs, landing, shelves, Balconies
Lintels, Beams, Girders and Cantilever upto floor two level. (For
17 Providing and laying controlled c.c. M.200 & curing complete 19.14 Cu.mt 7677.01
including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Collumns, pillars,
posts & struts upto floor two level for G.F.(For Column)
18 Providing and laying controlled cement concrete M.200 and curing 27.45 Cu.mt 6336.74
complete Including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in (C) Slabs, landing,
shelves, Balconies Lintels, Beams, Girders and Cantilever upto
floor two level. (For Beam)
19 Providing and laying controlled cement concrete M.200 and curing 34.14 Cu.mt 4693.47
complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in (C) Slabs, landing,
shelves, Balconies Lintels, Beams, Girders and Cantilever upto
floor two level.(For Grade slab)
20 Providing and laying controlled cement concrete M.200 and curing 36.84 Cu.mt 6432.69
complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in (C) Slabs, landing,
shelves, Balconies Lintels, Beams, Girders and Cantilever upto
floor two level.(For slab)For GF Slab
21 Providing TMT Bar FE 500D reinforcement for R.C.C. work 30273.50 Kg 77.29
including bending ,binding and placing in position complete up to
floor two level
22 Providing and fixing M.S. Fan clamps type 1 to 16mm diaM.S. bar 30.00 Nos 131.93
bent to shape with hooked ends to R.C.C. slabscuring, laying
including painting the exposed portion ofloops, all as per standard
design complete
23 Providing & fixing 40 mm thick Single shutter flush door solid core 20.16 Sq.mt 7424.51
finished with both side 1 mm thick lamination both side like
'NOVAPAN 'or equivalent, of natural wood grain shade as approved
by this office having telephone black granite 18 mm thick frame with
double stone as per the instruction of Engineer in charge.with
necessary SS hinges and fixtures etc . complete.
24 Providing & fixing 35 mm thick Single shutter flush door solid core 4.74 Sq.mt 7015.46
finished with both side 1 mm thick laminationboth side like
'NOVAPAN 'or equivalent, of natural wood grain shade as approved
by this office having telephone blackgranite 18 mm thick frame with
double stone including fixed ventilation above lintle level as per drg
and as per theinstruction of Engineer in charge.with necessary SS
hinges and fixtures etc . complete.
It. No. Description of Item Quantity Unit Rate in Figure Total
25 Providing and fixing window having extruded aluminum colour 21.60 Sq.mt 3199.68
anodized section frame main outer size 95mm x 24mm x 1.17mm
(of Jindal section no.2459 @ Wt. 0.738 Kg/mt), horizontal three
track member size 92mm x 31.75mm x 1.30mm (of Jindal section
no. 8688, @ Wt. 1.07 Kg/mt), vertical member of size 92mm
31.75mm x 1.50mm (of Jindal section no. 8933 @ Wt. 1.06 Kg/mt)
with sliding shutters of horizontal member size 40mm x 18mm x
1.29mm (of Jindal Section No. 8947 @ Wt. of 0.456 Kg/mt), vertical
member of size 40mm x 18mm x 1.29 mm (of Jindal section no:
8949 @ Wt. of 0.456 kg / mt) with 5 mm th transparent bronze
colour tinted float glass with powder coated aluminum fittings and
fixtures and transparent silicon sealant glass fixing Including 18 mm
Granite Frame as per details etc.
26 Providing and fixing FRP frame size 125x65 mm and 35mm thick 11.49 Sq.mt 2019.98
FRP shutter with wood grain raised panneled design finish shutter
having extra reinforcement on sides & edges in Gel coat finish. The
core of the shutter & frame is to be filed up with injected
polyurethene foam done in situ alongwith embedded wooden pieces
for stiffening & also taking hinges & fintures. The whole FRP frame
& shutter is to be water proof weather proof, termite proof &
resistance to mild acid/alkali. Rates are to be inclusive of S.S
hinges with fastener sleeve & alluminium fixtures & fastenings.
27 Providing and fixing Louverd type ventilators with powder coated 1.62 Sq.mt 13733.98
aluminum fittings and fixtures and Blur glass fixing to Adjustable
louverds and black granite frame as per details and executed as per
directed by Engineer Incharge.
28 Providing and fixing M.S. grills of required pattern to 430.50 KG 128.27
wooden/Marble/Granite/Stone frames of windows etc. with M.S.
flats at required spacings and frame alround, square or round bars
with round headed bolts and nuts or by screws (A) Ornamentle Grill.
29 Providing and fixing M.S. grills of required pattern to 731.58 KG 264.62
wooden/Marble/Granite/Stone frames of windows etc. with M.S.
flats at required spacings and frame alround, square or round bars
with round headed bolts and nuts or by screws (A) Ornamentle Grill.
30 Providing and fixing rolling shutters of approved makemade of 80 31.92 Sq.mt 4546.01
mm wide M.S. laths inter-locked togetherthrough their entire length
and jointed together at the endsby end locks mounted on specially
designed pipe shaft withbracket plates, guide channels and
arragements for insideand outside locking with push-pull operation
including thecost of hood cover and spring etc. complete. (B)
Shuttershaving width 3.5 M. and above
31 P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 148.50 Sq.mt 1451.16
mm(average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand)
on new surface or fixing on existing flooring byadhesive material
including dismentaling of existingflooring and jointed with color
cement slurry includingfinised with flush pointing & cleaning the
surface etc.complete for light shade
32 P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm 7.68 Sq.mt 1432.78
(average) base of cement mortar 1:6 (1 cement: 6 coarse sand) on
new surface or fixing on existing flooring by adhesive material
including dismentaling of existing flooring and jointed with color
cement slurry including finised with flush pointing & cleaning the
surface etc. complete for antiskit.
33 Providing and laying Marbo Grenite tiles 8 to 10 mm thick , 24'' x 77.46 Sq.mt 1169.98
24'' in skrting risers of steps and dedo on 10mm thick cement
plaster 1:3 (1-cement : 3-coarse sand) and jointed with white
34 Providing and laying polished Kota stone slab flooring over 20mm 49.26 Sq.mt 1069.62
(Average) thick base of cement mortar 1:6 (1-cement : 6-coarse
sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and
jointed with grey cement slurry mixed with pigment to match the
shade of slab including rubbing and polishing etc. complete. (B)
It. No. Description of Item Quantity Unit Rate in Figure Total
35 Providing and laying 18 mm thick machine cut, free edges, machine 6.81 Sq.mt 3325.93
polished Black Granite tread and risers in single piece with 1 cm
nosing and necessary grooves on treads etc. complete.
36 Providing and laying BBCC of 75mm th. Layer in CM (1:3) including 252.72 Sq.mt 621.15
sparaying two coat of water proofing chemical with selected brand
by enginner incharge .i.e.perma or other with leveling complete for
ready base of china mosaic tratment.
37 Providing and laying broken china mosaic flooring for terrace using 245.43 Sq.mt 765.97
12 mm to 20 mm broken pieces of glazed tiles to be laid over
cement mortar 1:3 to plain or slope and to be tempered to bring
mortar creme out upto surface using white cement including
rounding off junctions and extending them upto 15 cm along the
wall,clearing with water and oxalic acid etc. as directed.
38 Providing and cement vata (10cm x 10cm size) quarter round in 79.86 Rmt 24.28
cement mortar 1:1 including neat cement finishing watering etc.
39 Providing 15mm thick cement plaster in single coat on Rough 669.72 Sq.mt 171.21
(Similar)side of single or half brick walls for interior plastering upto
floor two level and finished even and smooth in (ii) Cement mortar
1:4 (1-cement :4-sand) (Interior Plaster)
40 Providing 15 mm thick cement plaster in single coat on 208.14 Sq.mt 196.64
brick/concrete walls for interior plastering upto floor two level and
finished even and smooth in (i)Cement mortar 1:4 (1-cement:4-
sand) (ceiling Plaster)
41 20mm thick sand faced cement plaster on walls upto height 10 965.33 Sq.mt 337.52
metres above ground level consisting of 12mm thick backing coat of
C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M.
1:1 (1-cement : 1-sand) etc. complete.
42 Providing throating or plaster drip and moulding to R.C.C. Chhajja. 12.60 Rmt 42.02
43 Applying two coats of Birla or Asian acrylic lappy (putty) and two 610.86 Sq.mt 40.59
coats of primer of approved brand and manufacture on new wall
surface to give an even shade including thoroughly brushing the
surface free from mortar dropping and other foreign matter and
sand papered smooth. ( Interior Wall Putty)
44 Applying two coats of Birla or Asian acrylic lappy (putty) and two 208.14 Sq.mt 42.72
coats of primer of approved brand and manufacture on new wall
surface to give an even shade including thoroughly brushing the
surface free from mortar dropping and other foreign matter and
sand papered smooth. (Ceiling Putty)
45 Wall painting two coats with plastic emulsion paint of approved 610.86 Sq.mt 80.87
brand and manufacture on wall surfaces to give an even shade
including throughly brushing the surface free from mortar droppings
and other foreign matter and sand papered smooth. (Interior Wall
46 Finishing wall with weather proof exterior emulsionpaint on wall 965.33 Sq.mt 117.40
surface (two coats) to give an requiredshape even shade after
thoroughly brushing the surfaceto remove all dirt, and remains of
loose powdered materials.etc complete (Exterior Wall Paint)
47 Wall painting two coats with plastic emulsion paint of approved 208.14 Sq.mt 83.00
brand and manufacture on wall surfaces to give an even shade
including throughly brushing the surface free from mortar droppings
and other foreign matter and sand papered smooth on ceiling.
(Ceiling Paint)
48 Providing laying and jointing in true line and level 40mm dia. 33.00 Rmt 148.12
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make
PRINCE /SUPREME/ ASTRAL / FINOLEX or equivalent as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be concelled
as directed including necessary fittings etc. including testing of pipe
and joints and fixing the same with adhesive solvent, including cost
of all materials.
It. No. Description of Item Quantity Unit Rate in Figure Total
49 Providing laying and jointing in true line and level 32mm dia. 72.00 Rmt 119.15
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be concealed
as directed including necessary fittings etc. including testing of pipe
and joints and fixing the same with adhesive solvent, including cost
of all materials.
50 Providing laying and jointing in true line and level 15mm dia. 39.00 Rmt 72.65
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be concealed
as directed including necessary fittings etc. including testing of pipe
and joints and fixing the same with adhesive solvent, including cost
of all materials.
51 Providing and fixing concealed center point to wall ceiling & floor 24.00 Rmt 660.58
CPVC (SDR 13.5) PIPE having National SanitationFoundation
(NSF) seal for potable water of following dia. nominal bore tube
fittings and clamps including making goodthe wall, ceiling and floor
etc.complete. [F] 50mm.
52 Providing and fixing concealed center point to wall ceiling & floor 36.00 Rmt 253.82
CPVC (SDR 13.5) PIPE having National Sanitation Foundation
(NSF) seal for potable water of following dia. nominal bore tube
fittings and clamps including making good the wall, ceiling and floor
etc. complete. [C] 25 mm.
53 Providing laying and jointing in true line and level 110 diameter 81.00 Rmt 856.03
U.P.V.C. SWR Type B pipe confirmng to IS 13592-1992 with one
end plain and other end socketed with rubbering, & fitting
conforming to ISI 14735-1999 of approved make for drainage
system pipe line, pipe shall be jointd with each other with rubber
lubricant, pipe shall be fixed on wall using of PVC clamp of the size
110 mm diameter x 149 mm length x 145 mm high at every
mm center to center or shall be concealed in walls as directed
including necessary fittings such as Cowel vent, bends, shoes etc.
including testing of pipes and joints and jointed with adhesive
solvent cement including cost of all materials.
54 Providing and fixing screw down bib taps of following size.(A) Brass 12.00 Nos 214.81
screw down bib tap polished bright. (ii) 20mm dia.
55 Providing and fixing pillar tap, capstan head, screw down high 6.00 Nos 354.69
pressure with screws, shanks and back nuts. (ii) 20mm dia.
56 Providing and fixing chromium plated brass half turn flush cock of 9.00 Nos 263.77
approved quality including fixing in pipe line etc. complete.(ii) 25mm
57 Providing and fixing Gun metal check or non return full way wheel 6.00 Nos 663.43
valve.40 mm dia.
58 Providing and fixing Gun metal check or non-return fullway wheel 9.00 Nos 420.63
valve. (C) 25mm dia.
59 Providing and fixing Granite of 18 to 20mm thick having minimum 3.00 Nos 9511.17
single plece length of 210mm to be fixed on Walls to act as Study
Table / Wash Basin, including fixing the same using cement mortar
in proportion 1:1 etc. comp, Necessary Grove in Walls By Machine,
Front Side Round the edge and cutting hole in ganite stone for
wash basin, Computer Wire, including rubbing and polishing
finishing jointed with grey cement slurry including rubbing and
polishing finishing etc complete. etc complete.. with all labour &
material & equipment.....etc. Completed as directed by Engineer-in-
charge (A) Granite slab 18mm thick
60 Providing and fixing C.P.Brass towel rail complete with C.P.Brass 6.00 Nos 616.42
brackets fixed to woodenplugs with c.p.brass screws.(B) 600 mm x
61 Providing and fixing C.P. brass shower rose with 15mm or 20mm 3.00 Nos 282.16
inlet.(A) 100mm dia. Each
62 Providing and fixing 600mm x 450mm bevelled edge mirrror of 3.00 Nos 854.58
superior glass mounted on 6mm thick A.C. sheet or plywood sheet
and fixing to wooden pluge with C.P. brass screws and washers.
It. No. Description of Item Quantity Unit Rate in Figure Total
63 Providing and laying wash down water closet (european type Wall 3.00 Nos 10261.60
Hung WC pan) Florentine series FLS-WHT 0111B including
providing and fixing metropole Flush cock seat cover, jet wash etc
complete unit of jaquar Branch (or equvalant) including installing
and fitting as per manufacturers standards by skilled trained
plumber including testing etc complete quality and brand as
approved by Engineer in charge.
64 Providing laying and jointing in true line and level 160 diameter 42.00 Rmt 834.38
U.P.V.C. SWR Type B pipe confirmng to IS 13592-1992 with one
end plain and other end socketed with rubbering, & fitting
conforming to ISI 14735-1999 of approved make for drainage
system pipe line, pipe shall be jointd with each other with rubber
lubricant, pipe shall be fixed on wall using of PVC clamp of the size
160 mm diameter x 210 mm length x 196 mm high at every
mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including
testing of pipes and joints and jointed with adhesive solvent cement
including cost of all materials.
65 Providing and fixing PVC SWR Nahni trap IS 14735 fordrain - 100 21.00 Nos 572.32
mm diameter with jali of the followingnominal diameter of self
cleansing design with C.I screaddown or hinged grating including
the cost of cutting andmaking good the walls.
66 Providing and laying (two level or slopes ) and jointing with stiff 21.00 Rmt 312.76
mixture of cement mortar in proportion 1:1 salt glazed stone ware
pipes following nominal internal diametre including testing of pipes
and joints etc complete. 150 mm dia.
67 Constructing brick masonary chamber for under ground 6.00 Nos 2932.93
C.I.inspection chamber and bends with bricks having crushing
strength not less than35 kg/sq.cm in C.M.1:5 C.I.cover with frame (
light duty) 455 mm x 610 mm internal dimension total weight of
cover with frame to be not less than 38 kgs.(weight of cover 23 kg
and wt.of frame 15 kg)R.C.C.top slab with 1:2:4 mix ( 1 cement:2
coarse sand:4 graded stone aggregates 20 mm size)
foundationconcrete 1:5:10 inside plaster 15 mm thick cement mortar
1:3 finished smooth with a floating coat of neat cement on wall and
bed concrete etc complete.(I) Inside dimensions 455 mm x 610 mm
and 450 mm deep for single pipe line.
68 Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2- 3.00 Nos. 11042.74
coarse sand : 4-graded stone aggregate 20mm nominal size)
foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick
bats 40 + 50mm size) inside plastering 15mm thick with Cement
Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat
of neat cement and making channels in cement concrete 1:2:4 mix
(1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size)
finished smooth complete including curing and festing (i) Inside
size900mm x 1200mm and 1.5M. deep including C.I. cover with
frame size 560mm diameter total weight of cover and frame to be
not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame
Kg.)(A) With 230mm thick walls of brick msonry using brick having
crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5
(1- Cement: 5-Coarse sand) (1) A type depth 0.90 Metre for 150mm
diameter sewer.
69 Providing erecting and fixing double coated Syntex or equivalent 4500.00 Litre 3.95
PVC. (ISI) mark water tank of reqd capacity each with all necessary
fittings & connection etc. comp on terrace.
70 Providing and fixing ball cock of approved quality as directed.(A) 3.00 Nos 132.89
Copper metal(i) 25 mm dia.
71 Providing and laying sandwich type kitchen platform of size 2.10 9.81 Sq.mt 23691.57
x0.76 x 0.76 m and respected length with dhar polish or moulding
having base 4" and spport & base with marble or Kota as per site
requirement also loft and base finish with glaze tile and top with
selected shed of marble or granite with gas pipe provision and sink
including all fittings ,material and labour as per directed by engineer
It. No. Description of Item Quantity Unit Rate in Figure Total
72 Providing & Fixing Co2 type portable ABC Dry Powder Type ABS 9.00 Nos 3535.00
Fire Extinguisher Capacity 4.5 Kg. Discharge Range 3mt. Timing
to 180 Sec. standard approved IS code No. 2878:2004
73 (B) Providing sock pit of 5.00 Cu.M. Volume includingexcavating 3.00 Nos 3427.65
and filling brickbats with dry masonry workat top for 45cm. height
including covering the top withstone including providing vatas in
C.M. 1:3 with finishing curing etc. complete as directed.
74 Providing and fixing pre-cast Rubber Dye / steel Dye inter locking 394.28 Sq.mt 704.07
concrete block 60mm thick with grade of concrete M300 pnumatic
compressed / vibrated mechanically and as per approved design
Confirming to IS 15658 : 2006 including 35 mm Sand layer for
levelling and filling the joint with sand in proper line and level as per
guidlines of IRC : SP 63-2018 etc. Complete.
75 Providing and fixing pre-cast concrete kerb stone of gray cement 41.18 Rmt 370.68
based concrete block 30cm length,30cm height and 15cm thick of
M250 grade concret as per approved design and including
excavation for fixing in proper line and level,filling the joint with C:M
1:3 (1cement:3fine sand) etc complete
76 Providing and fixing eco-friendly light weight calcium silicate false 61.98 Sq.mt 1674.15
ceiling tiles having Tegular edge & 15 mm Thick Densified edges on
the Tile Periphery for Extra Strength The Light weight calcium
silicate ceiling tiles shall have , light reflection 85% non-combustible
as per B.S. 476 part IV, 100% humidity resistance and also having
thermal conductivity0.043° w/m KC.for the best thermal Insulation .
The Light weight calcium Silicate tile shall be of approved texture
Fine fissured/ Spintone/Cosmos having NRC value of 0.5 & Globe
having NRC value of 0.75 NRC or equivalent of size 595 X 595 mm
to be laid on true horizontal level suspended inter locking metal grid
of hot dipped galvanized steel sections (galvanizing @120 grams
per sqm including both side) consisting of main ‘T’ runner suitably
spaced at joints to get required length and size of 24X38mm made
from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and
cross ‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet
spaced 1200mm along spaced between main ‘T’ at 600mm centre
to centre to form agrid of 1200X600mm and secondary cross ’T’ of
length 600mm and size 24x28mm made of 0.30 mm thick
(Minimum) sheet to be interlocked at middle of the 1200X600mm
panel to form grid of size 600X600mm resting on periphery
walls/partitions on a perimeter wall angle pre-coated steel of size
(24X24X3000mm made of 0.40mm thick (minimum) sheet with the
help of rawl plugs at 450mm centre to centre with 25mm long dry
wall screws @ 230mm interval and laying 15mm thick Densified
edges light weight calcium silicate ceiling tiles of approved texture
(Fine Fissured/Cosmos/Spintone) in the grid including, cutting
/making opening for services like diffusers, grills, light fittings,
fixtures, smoke detectors etc.,
wherever required, Main ‘T’ runners to be suspended from ceiling
using G.I. slotted cleats of size 25X35X1.6mm fixed to ceiling with
12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable
rods with galvanized steel level clips of size 85X30X0.8mm, spaced
at 1200mm centre to centre long main ‘T’ bottom exposed with
24mm of all T-sections shall be pre-painted with polyester baked
paint, for all heights, as per specifications, drawings and as directed
by engineer-in-charge.Note:- Only calcium silicate false ceiling area
will be measured from wall to wall. No deduction shall be made for
exposed frames/opening (cut outs) having area less than 0.30 sqm.
The calcium silicate ceiling tiles shall have NRC. Value of
(Minimum) for Fine fissured/Spintone/Cosmos and 0.75 NRC for
Globe, light reflection 85% non-combustible as per B.S. 476 part IV,
100% humidity resistance and also having thermal conductivity.
0.043° w/m KC.for the best thermal Insulation
It. No. Description of Item Quantity Unit Rate in Figure Total
77 Painting lines, deashes, arrows, letters etc on roads, Air fields,on 35.60 Sq.mt 126.21
walls and like in two coats with road marking paint, brushing
including cleaning the surface of all dirt, dust and other foreign
matter. (i) Upto 10cm in width
78 Clearing and grubbing road land including uprooting rank vegetation 0.21 Hact. 82249.89
grass bushes, shrubs, sapling and trees girth up to 300 mm
removal of stumps of trees cut earlier and disposal of unserviceable
materials (A) By manual means in area of light jungle
79 Provinding and laying controlled cement concrete M -250 and 1.67 Cu.mt 4845.98
finishing smooth with curing etc complete, including the cost of
formwork but excluding the cost of reinforcement for R.C.C. work in
(A) Foundations, footings, Base of Columns and Mass concrete.
80 Providing, fixing and erecting steel shed including M.S. G.I. pipe 90.82 Sq.mt 2434.02
(class-B), framing of structure with hollow section And painting with
two coats of oil paint including priming coat. Rates including with
necessary fabrication work including cutting, welding, making holes
by drilling machine & fixing in line and level of all structure including
cost of all laboures, fixtures, fastening and equipments etc.
81 Office Table:- 18mm thick three layer pre laminated particle board 3.00 No. 23230.00
Work with PVC Edge band 2mm thick wrapped around the top,
Decorative aluminium bidding in top and modesty including all
necessary elements with necessary features and fastning finish all
as per directed by Engineer in Charge. 6FT Office Table
(Dimension :- 180 cm x 90cm x 75 cm) with suitable Brand.
82 Revolving Chair:- Full-Back Executive Office Chair upholstered in 3.00 No. 14897.50
bonded leather and PVC, Padded seat and back for all-day comfort
and support, Pneumatic seat-height adjustment; 360-degree swivel;
smooth-rolling casters and having overall dimension 73.9D x 66.5W
x 115.6H Centimeters with Armrest (Brown) with selected brand.
83 File Rack:- lack Adjustable 5-Shelf Shelving Unit Storage Rack 9.00 No. 7777.00
Utility Rack Garage Shelves Display Rack Steel Boltless Rivet
Rack, 60 inches Height 1-Pack ({5 - SECTION } 5'[H] X 2'[L] X
1'[D]) with suitable Brand.
84 Steel Stool:- Office Stainless Steel Stool having minimum oveall 15.00 No. 1818.00
dimension 35.6D x 35.6W x 76.2H Centimeters, made with S.S. leg
and rubber pad/bushing with suitable Brand which will select by
enginner in charge.
85 Chair:- S.S. Chair for Office having seat and back with selected 12.00 No. 2626.00
cushion, Fabric, Pattern, PU with arm rest and minimum overall
dimension 78.7D x 41.9W x 78.7H Centimeters with suitable Brand
which will select by engineer in charge.
86 Stainless Steel Office Almirah :Suppliny and instaling Portable 3.00 No. 15150.00
Modern double Door steel almariah with nearer 30 kg wt having
diamension 36 x 18 x 78.5 inch made from ss,Eco friendly and UV
resistant in grey color having min 4 partioin for file rack and other
copartment as per selected and directed by Engineer incharge.
87 Providing and fixing Precast RCC Compound Wall made of I shape 200.30 Rmt 2171.50
verticle Pre cast Pre tension post of size 2100 mm height , section
150 mm x 150 x 50 mm center slot and edge chamfer made from
concrete grade M-25 (For Vertical Post), 2135 mm x 300mm x
mm plank made of pre cast and pretension from concrete grade M-
25 with 3 nos of 4mm tension wire and Edge 10 x 10 mm chamfer
(For Panel)7 panel in row position having center to center space not
more than 2.25 meter and segemnt height made of 2100 mmasper
design or as per directed by engineer incharge.
88 Providing and fixing ms grill entarnace gate of predetermine design 18.90 Sq.mt 4749.02
including all material like hinges,roller,stopper ,rail head , handle etc
having coat of red lead and painting with selected colour guide by
engineer incharge.
It. No. Description of Item Quantity Unit Rate in Figure Total
89 Providing and laying controlled cement concrete M.250 and curing 6.08 Cu.mt 8780.94
complete including the cost of formwork and Excluding the cost fo
reinforcement for reinforced concrete work in (D) Columns, Pillars
posts and struts, upto floor two level.
90 Providing and laying burnt brick masonary for super structure with 12.70 Cu.mt 4428.08
ordinary portland cement mortar 1:5 proportion including providing
scaffolding racking out joints curing etc. complete for all leads and
lifts. (Conventional Bricks) upto floor two level.
91 Providing and laying and fixing 50 mm thick expansion joint by 3.38 Sq.mt 1491.03
hydro cell semi rigid UV resistance with high performance laminated
closed cell polythene foam joint filler in sheet foam as directed, etc.
ELECTRIFICATION
92 Point wiring for Light/ Bell with 2-1.5 sq.mm & earthwire of 1.5 30.00 Pt. 449.45
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires, in following type of pipe to be
erected concealed in/ on surface on wall/ceiling complete with 6A
Modular type switch/ bell push & accessories and earth continuity
of following type, erected on PVC / Metallic box, single mounting
base frame covered with textured/metallic front plate modules
erected on/ in wall/ ceiling as per pipe erected, with necessary
Lamp holder/ ceiling rose/ H.D.Connector as directed. (a) with
medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling completeCat-III
93 Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm 15.00 Pt. 638.32
(Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated
multistrand copper wires, in following type of pipe to be erected
concealed in / flushed on wall/ceiling complete with 6A Modular type
switch and hum free EME four or more step type electronic fan
regulator with separately mounted and accessories with earth
continuity of following type erected on PVC / Metallic box, single
mounting base frame covered with textured/metallic front plate
modules erected on / in wall / ceiling as per pipe erected. with
necessary ceiling rose / H.D.Connector as directed. (a) with
medium class Rigid PVC pipe and accessories, Cat-III
94 Point wiring for Looped Plug with 6A Modular type switch & 5 pin 15.00 Pt. 257.55
socket erected on PVC / Metallic box, single mounting base frame
covered with textured / metallic front plate modules erected on / in
wall / ceiling with following type accessories, Cat-III
95 Point wiring for Individual Plug with & earthwire of 1.5 sq.mm 15.00 Pt. 711.04
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multistrand copper wires, in following type of to be erected
concealed in / on surface of wall / ceiling complete with Modular
type switch & 5 pin Plug erected on PVC / Metallic box covered
with appropriate front plate modules erected on / in wall / ceiling as
per pipe erected with following type of accessories. [II] For 16A Plug
with 2-2.5 sq.mm Cu. Wire, (a) with medium class Rigid PVC pipe
and accessories erected flushed on wall/ceiling complete, Cat-III
96 Providing & erecting Switch board for Computer or electric 12.00 Nos. 1133.22
apparatus consisting of following modular type accessories
mounted with PVC / Metallic concealed/open box with single
mounting base frame covered with textured/metallic /white front
plate,modules erected with necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug [B] For Modular Type Accessories, Cat-III
97 Providing and erecting Mains with 1.1 KV grade FRLS PVC 150.00 Mtr. 82.82
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size , (a) with medium
class Rigid PVC pipe and accessories, (b) 2 wire 2.5 mm²
It. No. Description of Item Quantity Unit Rate in Figure Total
98 Supplying and erecting Flexible PVC insulated multi strand multi 18.00 mtr 77.77
core 1.1 kv grade ISI marked copper wires of following size to be
erected as directed.(h) 2.50 Sq.mm 3 core round PVC sheathed
99 providing and erecting Mains with 1.1 KV grade FRLS PVC 30.00 mtr 260.58
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (A) with medium class
Rigid PVC pipe and accessories (h) 4 wire 6 sq. mm
100 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 24.00 Nos. 535.30
Watt to 0.5 Watt assembled on single MCPCB, with housing used
as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company mark/name 160V
to 270V, Power Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)),(A) Tube Light with integral/ non-
integral driver, (v) 36-40 Watts, Surge-2 KV, IP-20, conventional
101 Supplying and erecting led lamps with following wattage capacity of 3.00 Nos. 112.11
220 to 240 voltage, minimum 15000 burning hours life, 500 V in built-
surge protection,Polycarbonate diffuser, mounting suitable for E14 /
E27 / B22 lamp holders, pf >= 0.5 (A) LED Lamps integral type, with
PC diffuser suitable LAMP holder (ii) 5 to 8 watts CAT-III
102 Providing and erecting Approved make Ceiling fan with double ball 15.00 Nos. 1596.81
bearing ISI mark with condenser A.C. 23OV.50 c/s.1200 mm.
sweep complete, canopy erected on existing hook or clamp with
earthing. [Make shall be approved by Engineer in charge]]
103 Supplying and erecting 19/20 mm. nominal bore Medium Class M.S. 15.00 Mtr. 108.07
Pipe down rod erected duly painted for fan complete with necessary
24/ O.20, 3 core flexible wire with earthing.
104 Supplying & erecting approved make low noise decorative exhaust 3.00 Nos. 1703.87
fan having square frame ABS body with inbuilt lowers & square
frame.200mm with 1350RPM Cat.II
105 providing and erecting Miniature circuit breaker single pole 6A to 36.00 Nos. 112.11
25A suitable to operate on 240 V A.C. system and having breaking
capacity 10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark CAT-III
106 Providing and erecting Sheet Steel powder coated MCB distribution 3.00 Nos. 2339.16
board - flush / surface mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should
be used of same company of MCB to be used) suitable for (B) three
phase incoming and single phase horizontal type outgoing Per
phase isolation type (PPI) (b) sheet steel double door (i)4 way
107 Providing & erecting 415 V MCB Four Pole for Motor & Inductive 3.00 Nos. 668.62
Load (C Curve) having 10KA breaking capacity & confirms to IS
:8828 in existing box having following capacity (b)40 Amp., Cat-III
108 Providing & erecting 240 V MCB double pole switch for lighting 3.00 Nos. 299.97
Load (B Curve) having 10 KA breaking capacity & confirms to IS :
8828 in existing box having following capacity CAT-III (a)6 to 32 A
109 Plastic enclosure fitted with DIN rail suitable for incorporating One / 3.00 Nos. 52.52
It. No. Description of Item Quantity Unit Rate in Figure Total
110 Aproviding and erecting Approved make RCCBs conforming to IS: 9.00 Nos. 1969.50
12640 and having sensitivity of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation on single phase
V,50Hz. having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic component. for
following Max. rating erected as directed (i) 25 Amps., Cat-III
111 Supplying & erecting earth pit of minimum bore dia.150mm size 3.00 Nos. 4591.46
approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with constant ohmic
value surrounded by highly conductive compound with high charge
dissipation suitable for following type of applications with chamber
and heavy duty cover. (A)(approved make OEM has to submit test
certificate including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to ensure
the value of earthing resistane mentioned in test Certificate) &
having back filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:-
<2%(C) Back fill Compound :- Earthing compound should be
capable to retain moisture for long time Necessary test report must
be submitted by Agency. (a) For Electrical Installation up to 440V in
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
112 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable 66.00 mtr 153.52
multistrand Aluminium conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of following size of
cables(A) 4 core 16 Sq. mm
113 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 159.00 mtr 92.92
Aluminium conductor for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe of following size of cables. (B)
114 Providing and, fixing heavy duty flange type brass cable gland with 36.00 ea 38.38
rubber ring for PVC insulated armoured cable complete with out
going tails, insulating tape etc for following size of cables. (B) 2 to
115 Supplying and erecting LED street light / Flood light fittings with 18.00 Nos. 3345.12
High power White LEDs wattage of 3 Watt and above assembled
on single MCPCB, efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power Factor
more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity
ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver
efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.), (A) Street Light
(IP-65), Surge protection -4KV integral and ,Light must have
440VAC line supply with over-voltage protection. (i) above 36 to
116 Providing and erecting Miniature circuit breaker single pole 0.5A to 18.00 Nos. 270.68
2A system and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark
117 Supplying & erecting approved make SMC press moulded 18.00 Nos. 476.72
composite FRP. loop-in, loop-out approx. 2mm thick box complete
with Bakelite connector strip 5way(3P+N+E),DIN rail for mounting
mob & hinged doors as per requirement having locking
arrangements with mounting clamp with nuts, bolts & washers
suitable for erection on pole with cable clamps& earth bolt of
following size of box..( c)150mm x 125mm x 100mm [deep]
It. No. Description of Item Quantity Unit Rate in Figure Total
118 Providing and erecting Street Light pole bracket comprising main B 18.00 Nos. 614.08
Class GI pipe of 4.2 cm/require outside dia. complete with suitable
B Class G.I. sleeve tubing of approx. 45cms.length and suitable for
76.5 mm /80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of 1.5.mtr.
length with 110 deg.with vertical plane & suitable welded stays,
reducer and with check nuts complete painted with one coat of Red
oxide / PU base primer and two coats of Aluminium / PU paint. paint
with following nos of arms. [A] Single Arm bracket 1 Mtr
Replacing old & u/s Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of following size evenly crimped
with high pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.
121 Solder less crimping type Copper lugs conforming to IS suitable for 18.00 Nos. 8.08
cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut
bolts in an approved manner. . (A) 1.5/2.5 to 6 Sq.mm
122 Providing and erecting Approved make Four pole moulded case 3.00 Nos. 6790.43
circuit breaker having breaking capacity ICU of 25 KA. at
V,having normal current rating up to 25 A to 100A. with Fixed
thermal & magnetic release suitable to work on A.C. supply 50 c/s.
with all internal connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing.with enclosure
123 Supplying KITKAT pattern porcelain cut-out fuse with base of 9.00 Nos. 278.76
following current capacity erected on existing block board. (v)
A. 500 V. cat-iii
124 Supplying and erecting nuwood 12mm thick on existing angle iron 3.00 Sqmtr 385.82
frame or wooden patti
125 Providing & laying approved make Double walled corrugated pipes 60.00 mt 62.62
(DWC) of polyethylene(conforming to IS 14930 II )with necessary
connecting accessories of same material at required depth in
existing trench for laying of cable. below ground / road surface for
enclosing cable 50mm
126 Making trench in soft soil of suitable width of 90 cm deep for laying 54.00 mt 55.55
cable or locating the fault all over the run and back filling the same
and making the surface as normal ground.
Rs. Ninety Eight Lakhs, Fifty Six Thousand Three Hundred Twenty Four and Seven Paisa Only
I/We am/are willing to carry out the work @ ______________ % ______________ percent
(should be written in figures and words) below / above, the estimated rates mentioned above, amount of
my/our tender works out as under :
Above all items of "Bill of Quantities" with Item Description, Unit, Qty, Rate & Amount have verified by me and
It. No. Description of Item Quantity Unit Rate in Figure Total
1 The Contractor shall exhibit a board with detailed specification and details of work as directed by the
Engineer-In-Charge for which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills.
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-
10/2017 Cement Consumption/16/C, Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where
there is a change as per actual mix design the cost of difference of cement consumption have been deducted
from the rate of original item at the rate of input rate mentioned in all the tender.
5 The contractor will have to submit the mix design for different grades of cement concrete and asphalt
at his own cost before execution as directed and to be approved from the engineer in charge.
6 Dismentaling Credit Rs.15,000/- (Fifteen Thousand) only shall be recovered from contractors R.A.
Deputy Executive Engineer Executive Engineer
District (R&B) Sub Dn. No.1 District (R & B) Division
Vadodara Vadodara
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
4. BOQ.pdf
5. Index.pdf
6. Tech. Specifications.pdf
7. Electrical Booklet.pdf
8. Spl. Condition Electrical.pdf
9. Condition Electrical Contractor.pdf
10. MOU Electrical.pdf
11. Make List - Electrical.pdf
12. ELECTRICAL G.R.PDF
13. Index - GRs - Govt.pdf
14. GRs - 2.pdf
15. Test Sch.pdf
16. Proposed Plan for pashudavakhana at village Sarsvani.pdf
17. Upkendra makan Plan.pdf
2. NIT.pdf
3. SBD.pdf
Download all tender documents and submit your bid