Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.3 LAccepted-AOC | ₹72.3 L | L1 | Accepted-AOC l1 |
| 2 | L2₹74.8 LRejected-Finance | ₹74.8 L | L2 | Rejected-Finance 2nd lowest |
| 3 | L3₹84.3 LRejected-Finance | ₹84.3 L | L3 | Rejected-Finance 3rd lowest |
| Sl No | Description | Qty | Unit | V V Thomas L3 | Raju N K L1 | AMBUJAKSHAN K L2 |
|---|---|---|---|---|---|---|
| 1.00Laying Testing & Commissioning of Distribution system | ||||||
| 1.00 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. | 2,882.5 | cum | 505.91 ₹14.6 L | 450 ₹13.0 L | 520 ₹15.0 L |
| 1.00 | 100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals. | 1,000 | metre | 25.48 ₹25,480 | 5 ₹5,000 | 20 ₹20,000 |
| 1.00 | 100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes. | 4,000 | metre | 184.07 ₹7.4 L | 200 ₹8 L | 150 ₹6 L |
| 1.00 | 100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes. | 1,300 | metre | 116.78 ₹1.5 L | 120 ₹1.6 L | 100 ₹1.3 L |
| 1.00 | 100.12.9:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 100mm diameter nominal bore. | 30 | metre | 214.18 ₹6,425.40 | 200 ₹6,000 | 230 ₹6,900 |
| 1.01 | 100.12.11:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 150mm diameter nominal bore. | 60 | metre | 265.36 ₹15,921.60 | 280 ₹16,800 | 280 ₹16,800 |
| 1.01 | 100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I. | 2 | no | 807.34 ₹1,614.68 | 800 ₹1,600 | 1,200 ₹2,400 |
| 1.01 | 100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I. | 2 | no | 1,093.46 ₹2,186.92 | 1,200 ₹2,400 | 850 ₹1,700 |
| 1.01 | 100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve. | 2 | no | 305.42 ₹610.84 | 300 ₹600 | 1,200 ₹2,400 |
Tender Value
₹82.9 L
EMD Value
₹50,000
Closing Date
13 Aug 2024, 3:00 pmClosed
Executive Engineer
PH Division KWA S Bathery
Jal Jeevan Mission (JJM)-ARWSS to Krishnagiri, Purakadi and AmbalavayalPipeline extension from School junction to Moonankuzhi in Meenangadi GP
2024_KWA_684011_1
WRD/KWA-CE(NR)/TR/10201
Open Tender
Civil Works - Water Works
180 days
Meenagady
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,760
₹50,000
18 Feb 2026
5 Aug 2024
14 Aug 2024
5 Aug 2024
13 Aug 2024
5 Aug 2024
Amount
Laying Testing & Commissioning of Distribution system
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
100.12.9:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 100mm diameter nominal bore.
100.12.11:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 150mm diameter nominal bore.
100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.
100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.
100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Cost of pipe and Specials
100.98.239:Supply of PVC Pipe, 10kg/cm2, 160mm Dia.
100.98.237:Supply of PVC Pipe, 10kg/cm2, 110mm Dia.
OD23931/2024-2025:Supply of 150 mm GI Pipe
OD74207/2024-2025:Supplying of 100mm GI pipe Class B with special
100.98.460:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
100.98.458:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
100.98.451:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 100mm.
AMBUJAKSHAN K
V V Thomas
Bidder Name
Raju N K
V V Thomas
AMBUJAKSHAN K
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1064311.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid