Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹16.3 L Quoted ₹17.9 L | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER |
| 2 | L2₹18.8 L+₹82,946 (4.63%)Rejected-AOC AMBEDKAR PARK AND RAWAT PG HOUSE WARD NO 10 KHASRA NO 2435 DEHRADUN UTTARAKHAND 248 140 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248140 | ₹18.8 L+₹82,946 (4.63%) | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 3 | L3₹19.4 L+₹1.5 L (8.16%)Rejected-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹19.4 L+₹1.5 L (8.16%) | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
21 Sept 2024, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR/MAINT OF HT OCB, TRANSFORMER, LT PANELS, FEEDER PILLAR BOX AND HT/LT UG CABLES, OH LINES AND CERTAIN ALLIED WORKS AT ITM MUSSOORIE UNDER GE(I) RND DEHRADUN
2024_MES_668669_1
GE(I)RND/9402/E8/24-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dehradun
Class E Category b (ii) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹40,000
Yes
19 Oct 2024
31 Aug 2024
23 Sept 2024
31 Aug 2024
21 Sept 2024
7 Sept 2024
31 Aug 2024 - 7 Sept 2024
Amount
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing cable protection covers/ bricks & stacking serviceable bricks for reuse and disposal of unserviceable covers within 50 m complete all as specified and directed. Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
All as per Item No- 01 here in above but depth beyond first 1.5 m and not exceeding 3 m complete all as specified and directed.
M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed.
M&L for Removal of surplus excavated soils not exceeding 50 Mtr distance and depositing where directed by GE at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with flat, size 250 mm x 150mm x 40mm complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with flat, size 300 mm x 180mm x 40mm complete all as specified and directed.
Supplying, laying & jointing GI water tubing, 80 mm bore, light grade as in sleeving etc laid in trenches / ducts / Road cutting etc. complete all as specified and directed. (MAKE : TATA/JINDAL/TT SWASTIK)
Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / ducts / Road cutting etc. complete all as specified and directed. (MAKE : TATA/JINDAL/TT SWASTIK)
Dismantling & taking out unserviceable steel & iron items from poles and Supply & fixing cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts , washers , welding bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Disconnecting and taking out old existing unserviceable/ non- functional LT Cable and Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed. Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately )
35 Sqmm 3½ core
70 Sqmm 3½ core
95 Sqmm 3½ core
120 Sqmm 3½ core
185 Sqmm 3½ core
M & L for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc. size of cutting 100mm wide and 200mm deep and removing the excavated materials and disposal at 50 metre distance and making good the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as specified and directed.
Supply & fixing in replacement pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 100mm height and 65mm dia suitable for working pressure upto and including 1100 volts grade complete all as specified for LT lines fixed on poles.
Supply and fixing in replacement shackle type porcelain vitreous, white, brown or green insulator for working pressure 1100V of 115mm dia and 100mm high including galvanized mild steel strip 31 x 3mm, insulator bolts 14mm dia washer and nut complete all as specified for LT lines fixed on poles.
Supply and fixing in replacement aluminium conductor, steel reinforced (ACSR) of any size/description on LT poles/lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified and directed..
Supplying and fixing in replacement MCCB, 400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Ics = 100% of Icu 35/36 kA with adjustable thermal & magnetic setting, of Make : Legrand/Seimens/Schnieder/Havells
Supplying and fixing in replacement MCCB, 250 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 kA with adjustable thermal & magnetic setting, of Make : Legrand/Seimens/Schnieder / L&T / Havells
Supplying and fixing in replacement MCCB, 200 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 kA with adjustable thermal & magnetic setting, of Make : Legrand/Seimens/Schnieder / L&T / Havells
Supplying and fixing in replacement MCCB, 160 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 kA with fixed thermal & magnetic setting, of Make : Legrand/Seimens/Schnieder/Havells
Supplying and fixing in replacement MCCB, 100 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 kA with fixed thermal & magnetic setting, of Make : Legrand/Seimens/Schnieder/Havells
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of side operated OFF Load type changeover switch 4 pole, 415 volts, 400 Amps with and including sheet enclosure complete all as specified and directed. Cat part No: IHBFFE0400 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of side operated OFF Load type changeover switch 4 pole, 415 volts, 200 Amps with and including sheet enclosure complete all as specified and directed. Cat part No: IHBFFE0200 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of side operated OFF Load type changeover switch 4 pole, 415 volts, 100 Amps with and including sheet enclosure complete all as specified and directed. Cat part No: IHBFE0100 of make Havells or equivalent model of specified make as approved by GE.
Dismantling, taking down and removing the old existing un serviceable non-functional/broken GI sheet/hinges of any description and in any position of existing feeder pillar boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 50 mm long medium weight mild steel butt hinges in position and necessary GI sheet for door of panel/main switch etc with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed.
Ditto item No 29 above but supplying and fixing new cold rolled 100 mm long medium weight mild steel butt hinges in position –ditto-
Taking down unserviceable indication lamp and supplying, fixing, testing and commissioning indication lamp (LED type) with showing red, yellow and green in colour of 22.5 mm dia monitor on LT panel board suitable for 240 V AC supply all as specified and directed. Make : L&T /Binay.or equivalent approved.
Disconnecting, dismantling, taking out & removing unserviceable volt meter and Supplying, fixing, testing and commissioning of digital electronic volt meter 0-500 V range suitable for LT 415 Volts panel flush pattern square type 96mmX96mm with adopter complete with button all as specified and directed. Make : ENERCON/AE Note :- The rate quoted shall be deemed to including the following:- (i) Control wiring for auxiliary supply 230 Volts AC if required. (ii) Cutting the sheet of the panel to suit with existing panel if required. (iii) Calibration and testing the meter.
Supplying, Fixing, jointing and testing for provision of straight through joints, epoxy type with epoxy jointing materials, suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cables complete all as specified and directed. (MAKE : M.SEAL/DENSON/ MAHINDRA CHEMICALS/3M) :-
50 Sqmm 3½ core
70 Sqmm 3½ core
95 Sqmm 3½ core
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead 32X 6 mm GI strip, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate No . of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh incl necessary excavation and earth work in any type of soil, and PCC (1: 3 : 6) type C-1 (using 20 mm graded black trap/ granite/ Basalt stone aggregate) for earth pit with 40x40x6 mm mild steel angle iron frame for cover and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1(using 20 mm graded black trap/granite/ basalt stone aggregate) with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle, complete all as specified & directed .
Material and labour in replacement of UNSV GI strip of size 32mm x 6mm for laying along the wall/roof on batten or burried in ground or drawn in conduit pipe or fixed to poles or any other situation as directed or as required GI strip of size 32mm x 6mm earth continuity conductor complete with all accessories such as porcelain insulators, saddles and fixing screw etc for conductor all as specified and directed.
All as per item No.39 here in above but using 4 mm dia galvanised iron or steel wire complete all as specified and directed.
Disconnecting, dismantling, taking out & removing unserviceable MCCB box and Supplying and fixing of MCCB box of range 200 amp to 400 amp capacity complete all as specified and directed.
S&F in replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
S&F in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screwAir termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
S&F in replacement Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Supplying, Laying, testing and commissioning in replacement of UNSV XLPE insulated, PVC sheathed (heavy duty) armoured shielded cable 120 Sqmm 3core with aluminium conductor for working voltage upto 11KV (Earthed) ,conforming to IS 7098 Part-II amended upto date complete, having cross sectional area under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe including making necessary connection with VCB/OCB/ 4 pole/2 pole structure etc. complete all as specified and directed. Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and PCC protection shall be measured and paid separately )
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for indoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed.
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for indoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm to 120 Sq mm complete all as specified and ditected.
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for outdoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and ditected.
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for outdoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm to 120 Sq mm complete all as specified and ditected.
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for straight through, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and ditected.
Disconnecting and taking out old Unserviceable HT joint complete and Supply , jointing and testing cable jointing kit of 11 KV (Earthed) grade cable for straight through, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm to 120 Sq mm complete all as specified and ditected.
Supply and fixing in replacement of UNSV Steel tubular swaged poles complete with cast iron base plate, final, taper plug bolt, nuts & screws of type 410 SP-55 (11 M long) complete, all as directed all as specified. Note :- Earthwork, cement concrete in foundation, coping, cross arms ACSR conductors will be measured and paid separately under relevant items.
Supply , Install and testing in replacement of unserviceable insulators pin type porcelain, vitreous, white, brown or green insulators,for working pressure 11000 volts of size 150mm height and 150 mm dia including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, etc for HT lines fixed on poles complete all as specified and directed.
Supply , Install and testing in replacement of unserviceable disc type porcelain, vitreous, white, brown or green insulators,for working pressure 11000 volts of size 145mm height and 255 mm dia including two in series assembly for tension with tension clamps for conductors, etc for HT lines fixed on poles complete all as specified and directed.
Supply , Install and testing in replacement of unserviceable HT 11kV vertical swing triple pole gang operated air break switch (GOD) consisting of twelve insulator (3 insulators in each phase and one each for DO fuse). Mounted over the MS channel frame, operating mechanism, operating handle GI medium grade 25 mm bore, 5 mtr long with locking arrangement system connected with operating handle and 7 leaver lock of Godrej, moving and fixed jaws, copper jumpher strip etc suitable for 11000 volt 200 Amp current rating complete all as specified and directed.
Dismantling and taking down existing unserviceable lightning arrestor of any capacity and any description and Supply, fixing, commissioning & testing of distribution class lighting arrestor of rating 12 KV capacity and 10 KA NDC(Peak) confirming to to IEC-99.4 including brackets, clamps, bolts, nuts and washers complete all as specified and directed.
Supplying,Straightening and Stringing in replacement of UNSV aluminum conductor steel reinforced (ACSR) conductor off size including jointing the conductor with new conductor on existing HT pole and binding to insulator with the new aluminium wire binding wire 2 mm dia making and connecting jumper connections etc including connecting commissioning and testing complete all as specified and directed.
Supplying, Straightening and Stringing in replacement of UNSV Guard/ cradles hexagonal/ rectangular, fabricated in replacement of UNSV galvanized steel wire 3.15 or 4mm dia complete all as specified and directed.
M&L in replecement of UNSV jumper with weasel conductor suitable for HT, 11000 volts grade required at site with suitable size of lugs on both end including proper crimpinf etc.complete all as specified and directed.
Material and labour for cleaning and preparation of all existing steel surfaces of pole structure of straight steel tubular poles 11 mtrs long for painting including mild steel cross arms, clamps and anti clibing device,protection pipe etc and applying one coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles structure of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of poles including writing pole No and other sign works with white paint over black painted base in the pattern and style as approved by the complete all as specified and directed. Note : Size of black painted base for numbering shall be 100mmx25mm and the size of numbers shall be not exceeding 10cm height.
M & L for PCC 1:2:4 type B2 with 40mm grade stone aggregate as in foundation for outstanding around pole near feeder pillar/LT panel foundation of stays, including form work, fair finishing to exposed surface complete all as specified and directed.
M&L for PCC 1:4:8 type D2 with 40 mm graded stone aggregate as in foundation for hard standing around pole & near feeder pillar/LT panel foundation of stays, including form work, fair finishing to exposed surface complete all as specified and directed.
M&L for PCC 1:3:6 type C2 with 40 mm grade stone aggregate for coping of poles,stays incl. form work complete all as specified and directed.
Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in brick walls built in cement mortar 1:6 complete all as specified and directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement plastering 1:4 complete all as specified and directed by Engr-in-Charge.
M & L for spreading crushed/hand broken 20/ 40 mm graded sand stone aggregate around and under 4 pole/ 2 pole structure/11 KV Yard uniformally complete, all as specified and directed. Note :- (i) Excavation of earth work will be measured & paid separately under relevant items. (ii) Spread thickness of aggregates shall be measured and cubical content shall be worked out with deduction of 20% for voids for arriving at net qty.
M&L in replacement of UNSV danger notice board and Supply and fixing new danger notice board size 250mmx200 mm made out of 1.6 mm thick mild steel sheet, suitable for 11KV HT line and applying two coats of synthetic enameled paint (red colour) over a coat of red oxide primer including writing letters,figures and conventional skull and bones of suitable size on board in standard pattern as per IS fixed with and including MS clamps made out of mild steel flat iron,bolts ,nuts and washers etc complete all as specified and directed.
M&L for marking over the HT Cable/HT Cable, Panel etc by paint complete all as specified and directed.
M&L for prepration of old steel surfaces over 10 cm width & girth and applying one coat of synthetic ehamele paint complete all as specified and directed.
Disconnecting defective transformer indoor/outdoor of any capacity up to 500 KVA both from HT/LT sides, and then drainage of complete transformer oil. Opening of top cover with due care and removal of all HT/LT winding connections from bushing and then lifting of core by means of tripod and chain pulley with due care for inspection and ascertain it’s serviceability state after keeping it aside. Removal of all sludge and unwanted material from tank and core, lowering of core assembly after carrying out required repairs to the winding and core. In case the repairs which are not possible at site then the transformer has to be taken to the work shop for repairs complete all as specified and directed. Note :- (i)The cost of transportation shall be paid separately. (ii)The cost of rewinding shall be paid separately.
Taking down of transformers of capacity 125 to 500KVA from transformer plate form mounted floor/2/4 pole structure form with due care after disconnecting all HT/LT connections on pole/ plate form and then lowering it by means of mobile crane/tripod and chainpully and remounting on transformer plate form mounted floor/2/4 pole structure after repairs complete all as specified and directed.
Lifting of Indoor/Outdoor transformer from PCC plateform/2/4 pole structure of concerned substation with the help of mobile crane , loading on truck for transporting to civil workshop at Dehradun city & unloading at workshop, transporting back from workshop after repairs to its existing location complete all as specified and directed.
Material and labour for replacement of worn out HT copper coils made out of super enamelled insulated copper wire all as per existing size and shape including all insulating, binding, varnishing and baking if required complete all as specified and directed.
Material and labour for replacement of worn out LT copper coils made out of super enamelled insulated copper strip all as per existing size and shape including all insulating, binding, varnishing and baking if required complete all as specified and directed.
Material and labour for replacement of worn out bushing rod made out of copper with heavy duty double nuts and one washer at both ends suitable for HT side all as exiting size, shape and length complete all as specified and directed. suitable for following capacity transformers:-
125 KVA Transformers.
315 to 500 KVA Transformers.
Material and labour for replacement of worn out bushing rod made out of copper with heavy duty double nuts and one washer at both ends suitable for LT side all as exiting size, shape and length complete all as specified and directed. suitable for following capacity transformers ;-
125 KVA Transformers.
315 to 500 KVA Transformers.
Material and labour for replacement of worn out porcelain bushing for 11KV HT side indoor /outdoor transformers with rubberised cork sheet washers all as required at site complete all as specified and directed. suitable for following capacity transformers:-
125 KVA Transformers.
315 to 500 KVA Transformers.
Material and labour for replacement of worn out porcelain bushing for 0.433 KV LT side indoor /outdoor transformers with rubberised cork sheet washers all as required at site and as directed by Engineer-in-Charge suitable for following capacity transformers:-
125 KVA Transformers.
315 to 500 KVA Transformers.
Material and labour for replacement of worn out off load tap changer all as per existing sample complete all as specified and directed. suitable for following capacity of transformers of any make.:-
125 KVA Transformers.
315 to 500 KVA Transformers.
Material and labour for replacement of UNSV oil temperature gauge /thermometer suitable for transformers all as per existing shape and size for any make and model transformers complete all as specified and directed
Material and labour for replacement of worn out neoprene rubberised cork sheet 4 mm thick for transformer top cover all as required at site and complete all as specified and directed suitable for following capacity transformers:-
125 KVA Transformers.
315 to 500 KVA Transformers.
Material and labour for replacement of worn out neoprene rubberised cork washer 4 mm thick suitable for HT/LT side bushing of off sizes complete all as specified and directed
Material and labour for replacement of UNSV silica gel breather assembly of any description/capacity and supply & fixing new breather assembly transparent body suitable for 11/0.433 KV transformers of capacity upto 125 KVA complete all as specified and directed
All as per item No 95 above but transformer of capacity above 315 KVA but upto 500 KVA
Dehydration/centrifuging of transformer oil by means centrifuging machine electrically operated at site of installation of transformer in running condition of transformer including testing of transformer oil before and after centrifuging from top and bottom of transformer at 4mm gap the BDV should be 40KV complete all as specified and directed.
Supply and topping up of transformer oil of dielectric strength of 60 BDV complete all as specified and directed
Preparation of old steel surface of transformer for painting externally including fins/radiators removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel metallic paint by means of spray gun at site of installation of transformer complete all as specified and directed suitable for following capacity of transformers:-
125 KVA Transformers.
315 to 500 KVA Transformers.
S& F in replacement of UNSV alluminium lugs after cutting the worn out /faulty cable end from HT/LT side of Transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop retuning, filling & making cable lead by providing aluminium lugs lead including crimping with crimping tools in the existing LT cable including necessary connection complete etc, complete all as specified and directed
Up to 50 Sq mm
From 70 Sq mm to 120 Sq mm
From 150 to 185 Sq mm
Material, labour testing and commisssioning Chemical Earthing with copper pipe electrode 3.0 M long having outer pipe dia 50mm & inner pipe dia 44mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical compostion Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% buried in ground by digging a bore of 150mm dia surrounded by soil friendly backfill compound non soluble in water including connection with Copper earth strip 20x3mm upto 7 meter length, making PCC pit of size 0.3mx0.3mx0.3m (inner size) in mix 1:3:6 type CI with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting hook made out of 8mm dia bar and testing on completion to acheive value not more than 0.5 ohm complete all as specified and directed.
Material and labour earthing continuity conductor to wall on batten or buried in ground or drawn in conduit or fixed to pole or any other indicated situation for loop earthing etc, as required 20x3 mm dia copper strip complete all as specified and directed.
Material and labour for replacement of unserviceable Silica gel crystel for transformer of best quality complete all as specified and directed
M&L for Testing and calibration of 11 KV OCB-02 Nos indoor type alongwith control panel and control wiring, protection system and relays by primary & secondary injection system, battery bank/battery chargers/DC system complete all as specified and directed. Note:- calibration & testing will be carried out by machine which will be arranged by the contractor under his own arrangement.
Disconnecting and taking out existing HT 11KV OCB 400 amps deassemble decarburizing contacts servicing and cleaning, rubbing and overhauling as per manufacterer's instructions, cleaning and lubricating moving parts of trolly, the mechanical parts incl Greasing oiling replacement of UNSV spare parts excluding the following spare parts etc and re-assembling the same after replacement as required and made the OCB/VCB serviceable including making all electrical connection and testing alongwith control panel and control wiring, protection system and relays by primary & secondary injection system bank/battery chargers/DC system complete all as specified and directed. Note :- (i): Any parts required for replacement to make the breaker serviceable will be measured and paid separately under appropriate item of Sch ‘A’ as supply only but fixing charges of the parts replaced/repaired is deemed to be included in these item (ii) All other accessories excluding sch item No: to be supplied and fixed by the contractor at his own arrangement.
Supply only the following items / spare parts suitable for 11 KV OCB, 400 Amps capacity of any make, dismantled/fixed under Sch ‘A’ item No. 110 here in above complete all as specified and directed .
Set of 6 Nos fixed arcing contact suitable for 400 amp OCB
Contact in replacement to threaded type suitable for 400 amp OCB
Epoxy spout insulator in replacement of assembly fixed with HT compound seal suitable for 400 amp OCB
Set of 2 Nos actuating spring complete
Contact block complete
Contact collar complete
Lifting cross bar assembly complete
Set of 02 Nos oil tank liners complete
Oil tank gasket complete
Supply only the following items / spare parts suitable for 11 KV VCB, 400 Amps capacity of any make, dismantled/fixed under Sch ‘A’ item No. 111 here in above complete all as specified and directed.
Vacuum Interrupter
Bushing (Female)
flexible connectors
Closing coil assembly 30/24 volts DC.
Tripping coil assembly 30/24 volts DC.
Heating element with thermostat switch 150 Watt compact type
Motor cut off limit switch.
Spring charge motor, single phase suitable for spring charge motorised mechanism
Auxilary switch (6 NO + 6 NC ).
11 KV bus insulator of suitable for 11 KV VCB/OCB Panel complete all as specified and directed.
Supply, testing and calibration of IDMT relay CGI-14C over current low and high set & Earth fault low and high set relay type aux voltage 0 to 24 volts DC, CT ratio secendary 1A or 5A , with inbuilt master trip & TCS feature. The setting of relays to off trip match as per the CTs ratio and complete all as specified and directed
Disconnecting, dismantling,and taking out of unserviceable current Transformer from HT complete & Supplying installing commissioning and testing of new current transformer, indoor epoxy type, ratio 50-25/5-5 amp conforming to IS 2705 part I of 1981, 50 Hz for HT 11 KV having insulation level class1-P10, IL-28/75kv , burden of 15VA and breaking capacity 18.4 KA for 1.0 second and necessary thimbles nut bolts etc complete all as specified and directed
Supply, install, testing and commissioning in replacemen of UNSV Trip push button for 11 KV 400 Amps OCB complete all as specified and directed
Supply, install, testing and commissioning in replacement of UNSV Voltmeter square type Digital suitable size for existing 11 KV OCB capacity 0 to 15 KV PT Ratio 11KV/110Volt for panel complete all as specified and directed.
Supply, install, testing and commissioning in replacement of UNSV 11 KV panel indicating lamp fitting LED type suitable for 24 volt/30volt DC complete with base complete all as specified and directed.
Preparation of old steel surfaces of VCB/OCB Panel Board cubical in shape applying two coat of synthetic enamelled paint of approved colour including supplying and fixing PVC name plate indicating different cable/switch and other accessories, connections complete all as specified and directed.
S&F battery bank with 02 Nos maintenance free batteries of 12 Volt, 180 AH capacity with electrolyte fully charged battery including interconnection, with trolly, suitable for minimum 10 hours rate of discharge battery bank for 11 KV OCB/VCB complete all as specified and directed.
Disconnecting and taking out of defective battery charger and supply and fixing new automatic battery charger 24 volts suitable for charging of two batteries of cap 12 volt, 180 AH, sheet metal enclosure complete all as specified and directed.
Supply and fixing fuse wire 5A for 11000 volt complete all as specified and directed.
Supply and fixing discharge rod with all accessories suitable for 11000 volt complete all as specified and directed.
S.K ASSOCIATE (BID ID -3096087)
Ansh Enterprises (BID ID -3092481)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .